R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
Alcatel-Lucent assumes no responsibility for the accuracy of the information presented, which is
subject to change without notice.
Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All
other trademarks are the property of their respective owners.
Copyright 2014 Alcatel-Lucent.
All rights reserved.
Disclaimers
Alcatel-Lucent products are intended for commercial uses. Without the appropriate network design
engineering, they must not be sold, licensed or otherwise distributed for use in any hazardous
environments requiring fail-safe performance, such as in the operation of nuclear facilities, aircraft
navigation or communication systems, air traffic control, direct life-support machines, or weapons
systems, in which the failure of products could lead directly to death, personal injury, or severe physical
or environmental damage. The customer hereby agrees that the use, sale, license or other
of
the products for any such application without the prior written consent of Alcatel-Lucent, shall be at
distribution
the customer's sole risk. The customer hereby agrees to defend and hold Alcatel-Lucent harmless from
any claims for loss, cost, damage, expense or liability that may arise out of or in connection with the
use, sale, license or other distribution of the products in such applications.
This document may contain information regarding the use and installation of non-Alcatel-Lucent
products. Please note that this information is provided as a courtesy to assist you. While Alcatel-Lucent
tries to ensure that this
information accurately
reflects
information provided
by the
supplier,
please refer
to the materials provided with any non-Alcatel-Lucent product and contact the supplier for
confirmation. Alcatel-Lucent assumes no responsibility or liability for incorrect or incomplete
information provided about non-Alcatel-Lucent products.
However, this does not constitute a representation or warranty. The warranties provided for
Alcatel-Lucent products, if any, are set forth in contractual documentation entered into by
Alcatel-Lucent and its customers.
This document was originally written in English. If there is any conflict or inconsistency between the
English version and any other version of a document, the English version shall prevail.
When printed by Alcatel-Lucent, this document is printed on recycled paper.
Page 3
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
Preface
This preface provides general information about the documentation set for optical
network terminals (ONTs).
Scope
This documentation set provides information about safety, features and
functionality, ordering, hardware installation and maintenance, and software
installation procedures for the current release.
Audience
This documentation set is intended for planners, administrators, operators, and
maintenance personnel involved in installing, upgrading, or maintaining the ONTs.
Required knowledge
The reader must be familiar with general telecommunications principles.
Acronyms and initialisms
The expansions and optional descriptions of most acronyms and initialisms appear
in the glossary.
Alcatel-Lucent 7368 ISAM ONT iii
Edition 01
G-240W-B Product Guide
Page 4
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
Preface
Assistance and ordering phone numbers
Alcatel-Lucent provides global technical support through regional call centers.
Phone numbers for the regional call centers are available at the following URL:
http://www.alcatel-lucent.com/myaccess.
For ordering information, contact your Alcatel-Lucent sales representative.
Alcatel-Lucent quality processes
Alcatel-Lucent’s ONT manufacturing, testing, and inspecting practices are in
compliance with GR-1252-CORE and TL 9000 requirements. These requirements
are documented in the Operations Quality Plan
Alcatel North American Quality Manual
Wireline Network Quality Manual 8AB-83179-0001-QRAAA.
The quality plans and practices adequately ensure that technical requirements and
customer end-point requirements are met. The customer or its representatives may
be allowed to perform on-site quality surveillance audits, as agreed upon during
contract negotiations.
8BD-00023-4204-QRZZA,
8BD-00001-0000-QRZZA,
the
and the
Safety information
For safety information, see the appropriate safety guidelines chapter.
Documents
Documents are available using ALED or OLCS.
Procedure 1 To download a ZIP file package of the customer
documentation
1 Navigate to
and password. If you are a new user and require access to this service, please
contact your Alcatel-Lucent sales representative.
2 From the Technical Content for drop-down menu, choose the product.
3 Click on Downloads: Electronic Delivery.
4 Choose Documentation from the drop-down menu and click Next.
5 Select the image from the drop-down menu and click Next.
6 Follow the on-screen directions to download the file.
iv Alcatel-Lucent 7368 ISAM ONT
http://www.alcatel-lucent.com/myaccess
and enter your user name
Edition 01
G-240W-B Product Guide
Page 5
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
Preface
Procedure 2 To access individual documents
Individual PDFs of customer documents are also accessible through the Alcatel-Lucent
Customer Support website.
1 Navigate to
and password. If you are a new user and require access to this service, please
contact your Alcatel-Lucent sales representative.
2 From the Technical Content for drop-down menu, choose the product.
3 Click on Manuals and Guides to display a list of customer documents by title and
part number. You can filter this list using the Release drop-down menu.
4 Click on the PDF to open or save the file.
http://www.alcatel-lucent.com/myaccess
and enter your user name
Special information
The following are examples of how special information is presented in this
document.
Danger —Danger indicates that the described activity or situation
may result in serious personal injury or death; for example, high
voltage or electric shock hazards.
Danger indique que l'activité ou la situation décrite
peuvent entraîner des blessures corporelles graves ou mortelles;
par exemple, haute tension ou de risques d'électrocution.
Warning —Warning indicates that the described activity or situation
may, or will, cause equipment damage or serious performance
problems.
Warning indique que l'activité ou la situation décrite ne
peut, ou la volonté, des dommages matériels de cause ou de graves
problèmes de performance
Caution — Caution indicates that the described activity or situation
may, or will, cause service interruption.
Caution indique que l'activité ou la situation décrite
Procedures with options or substeps
When there are options in a procedure, they are identified by letters. When there are
required substeps in a procedure, they are identified by roman numerals.
peut, ou la volonté, le service de la cause interruption.
Note —A note provides information that is, or may be, of special
interest.
Une note fournit des informations qui est, ou peut être,
d'un intérêt particulier.
Page 6
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
Preface
Procedure 3 Example of options in a procedure
At step 1, you can choose option a or b. At step 2, you must do what the step indicates.
1 This step offers two options. You must choose one of the following:
a This is one option.
b This is another option.
2 You must perform this step.
Procedure 4 Example of required substeps in a procedure
At step 1, you must perform a series of substeps within a step. At step 2, you must do
what the step indicates.
1 This step has a series of substeps that you must perform to complete the step. You
must perform the following substeps:
i This is the first substep.
ii This is the second substep.
iii This is the third substep.
2 You must perform this step.
Multiple PDF document search
You can use Adobe Reader Release 6.0 and later to search multiple PDF files for a
common term. Adobe Reader displays the results in a single display panel. The
vi Alcatel-Lucent 7368 ISAM ONT
results are grouped by PDF file, and you can expand the entry for each file.
Note —The PDF files in which you search must be in the same
folder.
être dans le même dossier
Procedure 5 To search multiple PDF files for a common term
1 Open Adobe Acrobat Reader.
2 Choose Edit→Search from the Acrobat Reader main menu. The Search PDF panel
appears.
3 Enter the search criteria.
Les fichiers PDF dans lequel vous recherchez doivent
Edition 01
Page 7
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
Preface
4 Click on the All PDF Documents In radio button.
5 Select the folder in which to search using the drop-down menu.
6 Click on the Search button.
Acrobat Reader displays the search results. You can expand the entries for each
document by clicking on the + symbol.
Alcatel-Lucent 7368 ISAM ONT vii
Edition 01
G-240W-B Product Guide
Page 8
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
ETSI ONT safety guidelines
This chapter provides information about the mandatory regulations that govern the
installation and operation of the optical network terminals (ONTs).
Safety instructions
This section describes the safety instructions that are provided in the ONT customer
documentation and on the equipment.
Safety instruction boxes
The safety instruction boxes are provided in the ONT customer documentation.
Observe the instructions to meet safety requirements.
The following is an example of the Danger box.
Danger —Possibility of personal injury.
Possibilité de blessures.
The Danger box indicates that the described activity or situation may pose a threat to
personal safety. It calls attention to a situation or procedure which, if not correctly
performed or adhered to, may result in death or serious physical harm.
Do not proceed beyond a Danger box until the indicated conditions are fully
understood and met.
The following is an example of the Warning box.
Warning 1 —Possibility of equipment damage. Possibilité de dommages matériels.
Warning 2 —Possibility of data loss. Possibilité de perte de données.
Page 9
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
Description
Label text
ESD warning
Caution: This assembly contains an electrostatic sensitive device.
Laser classification
Class 1 laser product
PSE marking
These power supplies are Japan PSE certified and compliant with
Japan VCCI emissions standards.
ETSI ONT safety guidelines
The Warning box indicates that the described activity or situation may, or will, cause
equipment damage, loss of data, or serious performance problems. It identifies a
possible equipment-damaging situation or provides essential information to avoid
the degradation of system operations or data.
Do not proceed beyond a warning until the indicated conditions are fully understood
and met.
The following is an example of the Caution box.
The Caution box indicates that the described activity or situation may, or will, cause
service interruption.
Do not proceed beyond a caution until the indicated conditions are fully understood
and met.
The following is an example of the Note box.
Caution 1 —Possibility of service interruption. Possibilité d'interruption de service.
Caution 2 —Service interruption.
Interruption de service
Note —Information of special interest.
The Note box provides information that assists the personnel working with ONTs. It
does not provide safety-related instructions.
Safety-related labels
The ONT equipment is labeled with the specific safety instructions and compliance
information that is related to a variant of the ONT. Observe the instructions on the
safety labels.
Table 1 provides sample safety labels on the ONT equipment.
Figure 1 shows the PSE certification.
x Alcatel-Lucent 7368 ISAM ONT
L'information d'intérêt spécial.
Table 1 Safety labels
Page 10
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
Warning
This is a
Class B product based
on the
standard
of
the Voluntary Control Council
for Interference
from Information Technology Equipment (VCCI).
If this is
used near a radio
or
television receiver
in
a
domestic environment,
it may
cause radio interference. Install
and use the
equipment
according
to the
instruction
manual.
Safety standards compliance
Alcatel-Lucent 7368 ISAM ONT xi
Edition 01
G-240W-B Product Guide
This section describes the ONT compliance with the European safety standards.
EMC, EMI, and ESD compliance
The ONT equipment complies with the following EMC, EMI, and ESD
requirements:
•EN 300-386 V1.3.2 (2003-05): Electromagnetic Compatibility and Radio
•EN 55022 (1998): Class B, Information Technology Equipment, Radio
Disturbance Characteristics, limits and methods of
•EN 55024 (1998): Information Technology Equipment, Immunity
Characteristics, limits and methods of measurement
• European Council Directive 2004/108/EC
• EN 300-386 V1.4.1: 2008
• EN 55022:2006 Class B (ONTs)
• EN EN 61000-3-2:2006
• EN EN 61000-3-3:2008
• IEC 61000-4-2:2001
• IEC 61000-4-3:2006
• IEC 61000-4-4:2004
• IEC 61000-4-5:2005
• IEC 61000-4-6:2003/A1:2004/A2:2006
• IEC 61000-4-11:2004
Equipment safety standard compliance
The ONT equipment complies with the requirements of EN 60950-1, Safety of
Information Technology Equipment for use in a restricted location (per R-269).
Figure 1 PSE certification
ETSI ONT safety guidelines
measurement
19841
Page 11
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
ETSI ONT safety guidelines
Environmental standard compliance
The ONT equipment complies with the EN 300 019 European environmental
standards.
Laser product standard compliance
For most ONTs, the ONT equipment complies with EN 60825-1 and IEC 60825-2
for laser products. If there is an exception to this
this information in the standards compliance section of the unit data sheet in this
Product Guide.
Resistibility requirements compliance
The ONT equipment complies with the requirements of ITU
for resistibility of telecommunication equipment installed in customer premises to
over voltage and overcurrents.
Acoustic noise emission standard compliance
The ONT equipment complies with EN 300 753 acoustic noise emission limit and
test methods.
Electrical safety guidelines
This section provides the electrical safety guidelines for the ONT equipment.
Note 1 —The ONTs comply with the U.S. National Electrical Code.
However, local electrical authorities have jurisdiction when there are
differences between the local and U.S. standards.
Les ONT sont conformes à la US National Electrical Code.
Cependant, les autorités locales électriques ont compétence quand il ya
Power supplies
The use of any
supported
contract with Alcatel-Lucent. Such use greatly increases the danger of damage to
equipment or property.
Cabling
The following are the guidelines regarding cables used for the ONT equipment:
• All cables must be approved by the relevant national electrical code.
• The cables for outdoor installation of ONTs must be suitable for outdoor use.
• POTS wiring run outside the subscriber premises must comply with the
requirements of local electrical codes. In some markets, the maximum allowed
length of the outside run is 140 feet (43 m). If the outside run is longer, NEC
requires primary protection at both the exit and entry points for the wire.
des différences entre les normes locales et américaines.
Note 2 —The ONTs comply with BS EN 61140.
BS EN 61140
non-Alcatel-Lucent approved
or
endorsed
compliance
regulation, you can find
Recommendation
Les ONT sont conformes à la norme
power supplies or power adapters is not
by
Alcatel-Lucent.
Such use will void any
warranty
K.21
or support
Page 12
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
ETSI ONT safety guidelines
Protective earth
Earthing and bonding of the ONTs must comply with the requirements of local
electrical codes.
ESD safety guidelines
The ONT equipment is sensitive to ESD. Operations personnel must observe the
following ESD instructions when they handle the ONT equipment.
Caution — This
equipment
is ESD sensitive. Proper ESD protections
should be used when you enter the TELCO Access portion of the
ONT.
Cet équipement est sensible ESD. Protections relatives
aux décharges électrostatiques doivent être utilisés lorsque vous
entrez dans la partie d'accès TELCO de l'ONT
During installation and maintenance, service personnel must wear wrist straps to
prevent damage caused by ESD.
Laser safety guidelines
Observe the following instructions when you perform installation, operations, and
maintenance tasks on the ONT equipment.
Only qualified service personnel who are extremely familiar with laser radiation
hazards should install or remove the fiber optic cables and units in this system.
Danger —There may be invisible laser radiation at the fiber optic
cable when the cable is removed from the connector. Avoid direct
exposure to the laser beam.
Il peut y avoir un rayonnement laser invisible sur le
câble à fibre optique lorsque le câble est retiré du connecteur.
Éviter l'exposition directe au rayon laser.
Observe the following danger for laser hazard. Eyes can be damaged when they are
exposed to a laser beam. Take necessary precautions before you plug in the optical
modules.
Danger —Possibility of equipment damage. Risk of eye damage by
laser radiation.
Possibilité de dommages matériels. Risque de lésions
oculaires par un rayonnement laser.
Laser classification
The ONT is classified as a Class 1 laser product based on its transmit optical output.
Laser warning labels
The following figures show the labels related to laser product, classification and
warning.
Figure 2 shows a laser product label.
Page 13
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
ETSI ONT safety guidelines
Figure 2 Laser product label
18455
Figure 3 shows a laser classification label. Laser classification labels may be
provided in other languages.
Figure 3 Laser classification label
CLASS 1 LASER
PRODUCT
PRODUCTO LASER CLASE
1
CLASE
1 DEL LASER
Figure 4 shows a laser warning label and an explanatory label for laser products.
Labels and warning may be provided in other languages. The explanatory label
xiv Alcatel-Lucent 7368 ISAM ONT
provides the following information:
• a warning that calls attention to the invisible laser radiation
• an instruction against staring into the beam or viewing directly with optical
instruments
• wavelength
• normal output power
• maximum output power
LASER CLASSE
G-240W-B Product Guide
1
18992
Edition 01
Page 14
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
Laser Warning
RADIACION
RAYO LASER.
Transmit optical output
The maximum transmit optical output of an ONT is +5 dBm.
Normal laser operation
In normal operation, fiber cable laser radiation is always off until it receives signal
from the line terminal card.
Eyes can be damaged when they exposed to a laser beam. Operating personnel must
observe the instructions on the laser explanatory label before plugging in the optical
module.
Danger —Risk of eye damage by laser radiation. Risque de lésions oculaires par un rayonnement laser.
Location class
Use cable supports and guides to protect the receptacles from strain.
Alcatel-Lucent 7368 ISAM ONT xv
Edition 01
G-240W-B Product Guide
ETSI ONT safety guidelines
Figure 4 Laser warning labels
INVISIBLE LASER RADIATION
DO
NOT STARE INTO
OR
VIEW DIRECTLY
OPTICAL
Wavelength(s): xxxx
Normal output power:
Max
output power:
Label
CLASS 1 LASER
RAYONNEMENT LASER CLASSE 1
RAYONNEMENT LASER INVISIBLE EVITER
NE
PAS DEMONTER. FAIRE APPEL
INVISIBLE LASER RADIATION PRESENT
WHEN NOT CONNECTED. AVOID DIRECT EXPOSURE
TOUTE EXPOSITION
CLASE
DE
LASER INVISIBLE. EVITAR CUALOUIER EXPOSICION AL
NO
DESMONTAR. LLAMAR A PERSONAL AUTORIZADO
1 DEL
Laser Warning Label
Laser Warning
PRODUCT
AU
FAISCEAU
A UN
LASER
INSTRUMENTS
yyy m W
PERSONNELL QUALIFIE
AT
FIBER OPTIC CABLE
BEAM
WITH
nm
xx m W
Label
TO BEAM.
18993
Page 15
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
ETSI ONT safety guidelines
Environmental requirements
See the ONT technical specification documentation for more information about
temperature ranges.
During operation in the supported temperature range, condensation inside the ONT
caused by humidity is not an issue. To avoid condensation caused by rapid changes
xvi Alcatel-Lucent 7368 ISAM ONT
in temperature and humidity, Alcatel-Lucent recommends:
•The door of the ONT not be opened until temperature inside and outside the
enclosure has stabilized.
•If the door of the ONT must be opened after a rapid change in temperature or
humidity, use a dry cloth to wipe down the metal interior to prevent the risk of
condensation.
•When high humidity is present, installation of a cover or tent over the ONT helps
prevent condensation when the door is opened.
Edition 01
G-240W-B Product Guide
Page 16
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
ETSI environmental and CRoHS guidelines
This chapter provides information about the ETSI environmental China Restriction
of Hazardous Substances (CRoHS) regulations that govern the installation and
operation of the optical line termination (OLT) and optical network termination
(ONT) systems. This chapter also includes environmental operation parameters of
Alcatel-Lucent 7368 ISAM ONT xvii
Edition 01
G-240W-B Product Guide
general interest.
Environmental labels
This section describes the environmental instructions that are provided with the
customer documentation, equipment, and location where the equipment resides.
Overview
CRoHS is applicable to Electronic Information Products (EIP) manufactured or sold
and imported in the territory of the mainland of the People’s Republic of China. EIP
refers to
technology,
as batteries and cables.
Environmental related labels
Environmental labels are located on appropriate equipment. The following are
sample labels.
products
and their
including electronic
accessories manufactured
communications
products and such subcomponents
by using
electronic
information
Page 17
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
ETSI environmental and CRoHS guidelines
Products below Maximum Concentration Value (MCV) label
Figure 1 shows the label that indicates a product is below the maximum
concentration value, as defined by standard SJ/T11363-2006 (Requirements for
Concentration Limits for Certain Hazardous Substances in Electronic Information
Products). Products with this label are recyclable. The label may be found in this
documentation or on the product.
Figure 1 Products below MCV value label
18986
Products containing hazardous substances above Maximum Concentration
Value (MCV) label
Figure 2 shows the label that indicates a product is above the maximum
concentration value, as defined by standard SJ/T11363-2006 (Requirements for
Concentration Limits for Certain Hazardous Substances in Electronic Information
Products). The number contained inside the label indicates the
Environment-Friendly User Period (EFUP) value. The label may be found in this
xviii Alcatel-Lucent 7368 ISAM ONT
documentation or on the product.
Edition 01
G-240W-B Product Guide
Page 18
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
Figure 2 Products above MCV value label
ETSI environmental and CRoHS guidelines
18985
Together with major international telecommunications equipment companies,
Alcatel-Lucent has determined it is appropriate to use an EFUP of 50 years for
network infrastructure equipment and an EFUP of 20 years for handsets and
accessories.
These values are based on
manufacturers' extensive
practical experience
of the design, manufacturing, maintenance, usage conditions, operating
environments, and physical condition of infrastructure and handsets after years of
service. The values reflect minimum values and refer to products operated according
to the intended use conditions. See “Hazardous Substances Table (HST)”for more
information.
Hazardous Substances Table (HST)
This
section describes
the
compliance
of the OLT and ONT
equipment
to the CRoHS
standard when the product and subassemblies contain hazardous substances beyond
the MCV value. This information is found in this user documentation where part
numbers for the product and subassemblies are listed. It may be referenced in other
OLT and ONT documentation.
In accordance with the People’s Republic of China Electronic Industry Standard
Marking for the Control of Pollution Caused by Electronic Information Products
(SJ/T11364-2006), customers may access the Alcatel-Lucent Hazardous Substance
Table, in Chinese, from the following location:
Observe the following environmental requirements when handling the P-OLT or
Alcatel-Lucent 7368 ISAM ONT xix
Edition 01
G-240W-B Product Guide
ONT equipment.
Page 19
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
ETSI environmental and CRoHS guidelines
ONT environmental requirements
See the ONT technical specification documentation for more information about
temperature ranges.
Storage
According to ETS 300-019-1-1 - Class 1.1, storage of OLT equipment must be in
Class 1.1, weather-protected, temperature-controlled locations.
Transportation
According
to EN
300-019-1-2
- Class 2.3,
transportation
of the OLT
equipment
must
be in packed, public transportation with no rain on packing allowed.
Stationary use
According to EN 300-019-1-3 - Class 3.1/3.2/3.E, stationary use of OLT equipment
must be in a temperature-controlled location, with no rain allowed, and with no
condensation allowed.
Thermal limitations
When the OLT is installed in the CO or CEV, install air filters on the P-OLT. The
thermal limitations for OLT operation in a CO or CEV are:
• operating temperature: 5°C to 40°C (41°F to 104°F)
• short-term temperature: –5°C to 50°C (23°F to 122°F)
• operating relative humidity: 5% to 85%
• short-term relative humidity: 5% to 95%, but not to exceed 0.024 kg of water/kg
Material content compliance
European Union (EU) Directive 2002/95/EC, “Restriction of the use of certain
Hazardous Substances” (RoHS), restricts the use of lead, mercury, cadmium,
hexavalent chromium, and certain flame retardants in electrical and electronic
equipment. This Directive applies to electrical and electronic products placed on the
EU market after 1 July 2006, with various exemptions, including an exemption for
lead solder in network infrastructure equipment. Alcatel-Lucent products shipped to
the EU after 1 July 2006 comply with the EU RoHS Directive.
Alcatel-Lucent has implemented a
The process is described in: Alcatel-Lucent process for ensuring RoHS Compliance
(1AA002660031ASZZA).
Directive 2011/65/EU
This ensures compliance with the European Union
on the
in Electrical and Electronic Equipment (RoHS2). With the process equipment is
assessed in accordance with the Harmonised Standard EN50581:2012 (CENELEC)
on Technical documentation for the assessment of electrical and electronic products
with respect to the restriction of hazardous substances.
xx Alcatel-Lucent 7368 ISAM ONT
material/substance
Restriction
of the Use of
content management process.
Certain Hazardous
G-240W-B Product Guide
Substances
Edition 01
Page 20
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
ETSI environmental and CRoHS guidelines
End-of-life collection and treatment
Electronic products bearing or referencing the symbol shown in Figure 3, when put
on the market within the European Union (EU), shall be collected and treated at the
end of their useful life, in compliance with applicable EU and local legislation. They
shall not be disposed of as part of unsorted municipal waste. Due to materials that
may be contained in the product, such as heavy metals or batteries, the environment
and human health may be negatively impacted as a result of inappropriate disposal.
Note —In the European Union, a solid bar under the symbol for a
crossed-out wheeled bin indicates that the product was put on the
market after 13 August 2005.
Dans l'Union européenne, un bar solide sous le symbole
d'une poubelle sur roues barrée d'une croix indique que le produit
a été mis sur le marché après le 13 Août 2005.
Figure 3 Recycling/take back/disposal of product symbol
At the end of their life, the OLT products are subject to the applicable local
legislations that implement the European Directive 2002/96EC on waste electrical
and electronic equipment (WEEE).
There can be different
states of the European Union.
In compliance with legal requirements and contractual agreements, where
applicable, Alcatel-Lucent will offer to provide for the collection and treatment of
Alcatel-Lucent
products bearing the logo shown in Figure 3 at the end of their useful
life, or products displaced by Alcatel-Lucent equipment offers. For information
regarding take-back of equipment by Alcatel-Lucent, or for more information
regarding the requirements for recycling/disposal of product, contact your
Alcatel-Lucent account manager or Alcatel-Lucent take back support at
takeback@alcatel-lucent.com.
Alcatel-Lucent 7368 ISAM ONT xxi
requirements
for collection and treatment in different member
Page 21
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
ANSI ONT safety guidelines
This chapter provides information about the mandatory regulations that govern the
installation and operation of the optical network terminals or units (ONTs or ONUs)
Alcatel-Lucent 7368 ISAM ONT xxiii
Edition 01
in the North American or ANSI market.
Safety instructions
This section describes the safety instructions that are provided in the ONT customer
documentation and on the equipment.
Safety instruction boxes in customer documentation
The safety instruction boxes are provided in the ONT customer documentation.
Observe the instructions to meet safety requirements.
The following is an example of the Danger box.
Danger —Possibility of personal injury. Possibilité de blessures
The Danger box indicates that the described activity or situation may pose a threat to
personal safety. It calls attention to a situation or procedure which, if not correctly
performed or adhered to, may result in death or serious physical harm.
Do not proceed beyond a Danger box until the indicated conditions are fully
understood and met.
Page 22
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
Description
Label text
UL compliance
Communication service equipment US listed. Type 3R enclosure Rainproof.
TUV compliance
Type 3R enclosure - Rainproof.
ESD warning
Caution: This assembly contains electrostatic sensitive device.
ANSI ONT safety guidelines
The following is an example of the Warning box.
The Warning box indicates that the described activity or situation may, or will, cause
equipment damage, loss of data, or serious performance problems. It identifies a
possible equipment-damaging situation or provides essential information to avoid
the degradation of system operations or data.
Do not proceed beyond a warning until the indicated conditions are fully understood
and met.
The following is an example of the Caution box.
The Caution box indicates that the described activity or situation may, or will, cause
service interruption.
Do not proceed beyond a caution until the indicated conditions are fully understood
and met.
The following is an example of the Note box.
Warning 1 —Possibility of equipment damage.
Possibilité de dommages matériels
Warning 2 —Possibility of data loss.
Possibilité de perte de données.
Caution 1 —Possibility of service interruption.
Possibilité d'interruption de service
Caution 2 —Service interruption.
Interruption de service.
Note —Information of special interest.
The Note box provides information that assists the personnel working with ONTs. It
does not provide safety-related instructions.
Safety-related labels
The ONT equipment is labeled with specific safety compliance information and
instructions that are related to a variant of the ONT. Observe the instructions on the
safety labels.
Table 1 provides examples of the text in the various ONT safety labels.
(1 of 2)
L'information d'intérêt spécial.
Table 1 Safety labels
Page 23
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
Description
Label text
Laser classification
Class 1 laser product
Laser product compliance
This laser product conforms to all applicable standards of 21 CFR
1040.10 at date of manufacture.
FCC standards compliance
Tested to comply with FCC standards for home or office use.
CDRH compliance
Complies with 21 CFR 1040.10 and 1040.11 except for deviations
pursuant to Laser Notice No. 50, dated June 24, 2007
Operation conditions
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any
interference received, including interference that may cause
undesired operation.
Canadian standard
compliance (modular ONT)
This Class A digital apparatus complies with Canadian ICES-003.
Canadian standard
compliance (outdoor ONT)
This Class B digital apparatus complies with Canadian ICES-003.
CE marking
There are various CE symbols for CE compliance.
Tested
to Comply
with FCC Standards
FOR HOME OR OFFICE
USE
COMMUNICATION SERVICE
EQUIPMENT
c
®
US LISTED
27FY
Type 3R Enclosure
- Rainproof
This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) this device may not cause
harmful
interference, and (2) this device must accept any
interference
received, including interference that may cause undesired
operation.
This Class A digital apparatus complies with Canadian ICES-003. Cet appareil
numerique de la class A est conforme a la norme NMB-003 du
Canada
CAUTION
This Assembly Contains Electrostatic Sensitive Devices
ANSI ONT safety guidelines
(2 of 2)
Figure 1 shows a sample safety label on the ONT equipment.
Figure 1 Sample safety label on the ONT equipment
Safety standards compliance
This section describes the ONT compliance with North American safety standards.
Warning — Changes or modifications to this unit not expressly
approved by the party responsible for compliance could void the
user's authority to operate the equipment.
non expressément approuvés par la partie responsable de la
conformité pourraient annuler l'autorité de l'utilisateur à utiliser
l'équipement.
Les changements ou modifications de cette unité
18533
Page 24
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
ANSI ONT safety guidelines
EMC, EMI, and ESD standards compliance
The ONT equipment complies with the following requirements:
•Federal Communications Commission (FCC) CFR 47, Part 15, Subpart B, Class
A requirements for OLT
equipment
• GR-1089-CORE requirements, including:
• Section 3 Electromagnetic Interference, Emissions Radiated and Conducted
• Section 3 Immunity, Radiated and Conducted
• Section 2 ESD
Immunity: Electrically Fast Transients
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
Discharge Immunity:
System Level
Electrostatic Discharge
and EFT
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is needed.
•Consult the dealer or an experienced radio/TV technician for help.
Equipment safety standard compliance
The ONT equipment complies with the requirements of UL60950-1, Outdoor ONTs
to “Communication Service Equipment” (CSE) and Indoor ONTs to Information
Technology Equipment (ITE).
Environmental standards compliance
The ONT equipment complies with the following standards:
•GR-63-CORE (NEBS): requirements related to operating, storage, humidity,
altitude, earthquake, office vibration, transportation and handling, fire resistance
and spread, airborne contaminants, illumination, and acoustic noise
• GR-487-CORE: requirements related to rain, chemical, sand, and dust
• GR-487 R3-82: requirements related to condensation
• GR-3108: Requirements for Network Equipment in the Outside Plant (OSP)
xxvi Alcatel-Lucent 7368 ISAM ONT
• TP76200: Common Systems Equipment Interconnections Standards
G-240W-B Product Guide
Edition 01
Page 25
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
ANSI ONT safety guidelines
Laser product standards compliance
The ONT equipment complies with 21 CFR 1040.10 and CFR 1040.11, except for
deviations pursuant to Laser Notice No. 50, dated June 24, 2007” or to 21 CFR
1040.10 U.S. Center for Devices and Radiological Health (CDRH) of the Food and
Drug Administration (FDA) Laser Notice 42 for ONTs containing Class 1 Laser
modules certified by original manufactures.
Per CDRH 21 CFR 10.40.10 (h) (1) (iv) distributors of Class 1 laser products, such
as ALU ONTs shall leave the following Laser Safety cautions with the end user.
a) “Class 1 Laser Product”
b)
“Caution
– Use of
controls
or
adjustments
or
performance
of
procedures
other than
those specified herein may result in hazardous radiation exposure.”
Figure 2 shows a laser product label.
No User Serviceable Parts Inside. Refer All Servicing To Qualified Personnel.
I.T.E
Complies with 21 CFR 1040.10 and
1040.11 except for deviations pursuant to
Laser Notice No. 50, dated June 24, 2007.
12VDC 2.5A
Resistibility requirements compliance
The ONT equipment complies with the requirements of ITU
for resistibility of telecommunication equipment installed in customer premises to
overvoltage and overcurrents.
Recommendation
K.21
Laser safety guidelines
Only qualified service personnel who are extremely familiar with laser radiation
hazards should install or remove the fiber optic cables and units in this system.
Observe the following warnings when you perform installation, operations, and
maintenance tasks on the ONT equipment.
Danger —There may be invisible laser radiation at the fiber optic
cable when the cable is removed from the connector. Avoid direct
exposure to beam.
Il peut y avoir un rayonnement laser invisible sur le
câble à fibre optique lorsque le câble est retiré du connecteur.
Alcatel-Lucent 7368 ISAM ONT xxvii
Éviter l'exposition directe au rayon
22813
Page 26
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
ANSI ONT safety guidelines
Observe the following danger for a laser hazard. Eyes can be damaged when they are
exposed to a laser beam. Take necessary precautions before you plug in the optical
modules.
Danger —Possibility of equipment damage. Risk of eye damage by
laser radiation.
Possibilité de dommages matériels. Risque de lésions
oculaires par un rayonnement laser.
Per CDRH 21 CFR 10.40.10 (h) (1) (iv) distributors of Class 1 laser products, such
as ALU ONTs shall leave the following Laser Safety cautions with the end user.
a) “Class 1 Laser Product”
b)
“Caution
– Use of
those specified herein may result in hazardous radiation exposure.”
Laser warning labels
The following figures show sample labels related to laser product, classification and
warning.
Figure 3 shows a laser product label.
Figure 4 shows a laser classification label. Laser classification labels may be
provided in other languages.
CLASS 1 LASER
xxviii Alcatel-Lucent 7368 ISAM ONT
CLASE
controls
1 DEL LASER
or
adjustments
Figure 3 Laser product label
Figure 4 Laser classification label
PRODUCT
or
performance
PRODUCTO LASER CLASE
of
procedures
LASER CLASSE
other than
18455
1
1
18992
Edition 01
Page 27
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
ANSI ONT safety guidelines
Figure 5 shows a laser warning label and an explanatory label for laser products.
Explanatory labels may be provided in other languages. The explanatory label
provides the following information:
• a warning that calls attention to the invisible laser radiation
• an instruction against staring into the beam or viewing directly with optical
instruments
• wavelength
• normal output power
• maximum output power
Figure 5 Laser warning labels
INVISIBLE LASER RADIATION
DO
NOT STARE INTO
OR
VIEW DIRECTLY
OPTICAL
Wavelength(s): xxxx
Normal output power:
Max
INSTRUMENTS
output power:
BEAM
WITH
nm
xx m W
yyy m W
Laser Warning
Label
Laser Warning
CLASS 1 LASER
PRODUCT
RAYONNEMENT LASER CLASSE 1
RAYONNEMENT LASER INVISIBLE EVITER
NE
PAS DEMONTER. FAIRE APPEL
RADIACION
RAYO LASER.
INVISIBLE LASER RADIATION PRESENT
WHEN NOT CONNECTED. AVOID DIRECT EXPOSURE
TOUTE EXPOSITION
DE
LASER INVISIBLE. EVITAR CUALOUIER EXPOSICION AL
NO
CLASE
DESMONTAR. LLAMAR A PERSONAL AUTORIZADO
1 DEL
AU
FAISCEAU
A UN
PERSONNELL QUALIFIE
LASER
AT
FIBER OPTIC CABLE
Laser Warning Label
Label
TO BEAM.
18993
Laser classification
The ONT is classified as a Class 1 laser product based on its transmit optical output.
For Class 1 laser products, lasers are safe under reasonably foreseeable conditions of
operation, including the use of optical instruments for intrabeam viewing.
Figure 6 shows a sample laser product safety label on the ONT equipment.
Alcatel-Lucent 7368 ISAM ONT xxix
Edition 01
G-240W-B Product Guide
Page 28
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
CLASS 1 LASER PRODUCT
THIS LASER PRODUCT CONFORMS TO ALL APPLICABLE
STANDARDS OF
21
CFR 1040.10
AT
DATE OF MANUFACTURE.
MANUFACTURED:
MONTH
YEAR
ANSI ONT safety guidelines
Figure 6 Sample laser product safety label on the ONT equipment
Transmit optical output
The maximum transmit optical output of an ONT is +5 dBm.
Normal laser operation
In normal operation, fiber cable laser radiation is always off until it receives signal
from the line terminal card.
Operating personnel must observe the instructions on the laser explanatory label
before plugging in the optical module.
Danger —Risk of eye damage by laser radiation. Risque de lésions oculaires par un rayonnement laser.
Location class
Use cable supports and guides to protect the receptacles from strain.
Electrical safety guidelines
This section provides the electrical safety guidelines for the ONT equipment.
Note —The ONTs comply with the U.S. National Electrical Code.
However, local electrical authorities have jurisdiction when there are
differences between the local and U.S. standards.
Cependant, les autorités locales électriques ont compétence quand il
ya des différences entre les normes locales et américaines.
Power supplies
The use of any
supported
contract with Alcatel-Lucent. Such use greatly increases the danger of damage to
equipment or property.
non-Alcatel-Lucent approved
or
endorsed
18532
Les ONT sont conformes à la US National Electrical Code.
power supplies or power adapters is not
by
Alcatel-Lucent.
Such use will void any
warranty
or support
Page 29
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
Cabling
The following are the guidelines regarding cables used for the ONT equipment:
• Use only cables approved by the relevant national electrical code.
• Use cables suitable for outdoor use for outdoor installation of ONTs.
• The ONTs have been evaluated for use with external POTS wiring without
primary protection that may not exceed 140 ft (43 m) in reach. However, the
power cable must not exceed 100 ft (31 m).
Protective earth
Earthing and bonding of the ONTs must comply with the requirements of NEC
article 250 or local electrical codes.
ESD safety guidelines
The ONT equipment is sensitive to ESD. Operations personnel must observe the
following ESD instructions when they handle the ONT equipment.
Caution — This
should be used when en tering the TELCO Access portion of the ONT.
appropriées doivent être utilisées lors de l'entrée de la partie TELCO
accès de l'ONT
During installation and maintenance, service personnel must wear wrist straps to
prevent damage caused by ESD.
Alcatel-Lucent recommends that you prepare the site before you install the ONT
equipment. In addition, you must control relative humidity, use static dissipating
material for furniture or flooring, and restrict the use of air conditioning.
Environmental requirements
See the ONT technical specification documentation for temperature ranges for
ONTs.
During operation in the supported temperature range, condensation inside the ONT
caused by humidity is not an issue. To avoid condensation caused by rapid changes
in temperature and humidity, Alcatel-Lucent recommends:
•The door of the ONT not be opened until temperature inside and outside the
enclosure has stabilized.
•If the door of the ONT must be opened after a rapid change in temperature or
humidity, use a dry cloth to wipe down the metal interior to prevent the risk of
condensation.
•When high humidity is present, installation of a cover or tent over the ONT helps
prevent condensation when the door is opened.
Alcatel-Lucent 7368 ISAM ONT xxxi
ANSI ONT safety guidelines
equipment
is ESD sensitive. Proper ESD protections
Cet équipement est sensible ESD. Protections ESD
Page 30
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
Contents
Preface iii
Scope
Audience
Required
Acronyms and initialisms
Assistance and ordering phone numbers
Alcatel-Lucent quality
Safety
Documents
Special
Multiple PDF document
ETSI ONT safety guidelines
Safety
Safety standards
Alcatel-Lucent 7368 ISAM ONT xxxiii
Edition 01
G-240W-B Product Guide
Table 1-14 G-240W-B ONT considerations and limitations
Table 4-1 Device Information parameters
Table 4-2 LAN status
Table 4-3 WAN status
Table 4-4 WAN status IPv6
Table 4-5 Home networking
Table 4-6 Optics module status
Table 4-7 LAN network
Table 4-8 LAN IPv6 network
Table 4-9 WAN network
Table 4-10 WiFi 2.4G network parameters
Table 4-11 WiFi 5G network
Table 4-12 Routing network
Table 4-13 DNS network
Table 4-14 TR-069 network
Table 4-15 Firewall parameters
Table 4-16 MAC filter
Table 4-17 IP filter
Table 4-18 DMZ and ALG
Alcatel-Lucent 7368 ISAM ONT 1-1
Edition 01
G-240W-B Product Guide
1.11 G-240W-B special considerations
1-14
Page 38
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
Mnemonic
Ordering kit
part number
Provisioning
number
Description
CLEI
CPR
ECI/
Bar
code
G-240W-B
3FE 56636 AA
3FE 56756 BAAA
Package
P 2 POTS ports, 4 10/100/1000
Base-T Ethernet interfaces, and
802.11b/g/n/ac Wi-Fi radio with
on/off switch.
This ONT also has 2 USB ports, 1 USB
3.0 and 1 USB 2.0.
Includes 3-pin wall-mounted US AC/DC
adapter.
———
3FE 56636 BA
3FE 56756 AABA
Package
P 2 POTS ports, 4 10/100/1000
Base-T Ethernet interfaces, and
802.11b/g/n/ac Wi-Fi radio with
on/off switch.
This ONT also has 2 USB ports, 1 USB
3.0 and 1 USB 2.0.
Includes 2-pin wall-mounted European
(EU) AC/DC adapter.
———
3FE 56636 CA
3FE 56756 AABA
Package
P 2 POTS ports, 4 10/100/1000
Base-T Ethernet interfaces, and
802.11b/g/n/ac Wi-Fi radio with
on/off switch.
This ONT also has 2 USB ports, 1 USB
3.0 and 1 USB 2.0.
Includes 3-pin wall-mounted British
(UK) AC/DC adapter.
———
3FE 56636 CB
Customer-spe
cific
3FE 56756 ABBA
Package
P 2 POTS ports, 4 10/100/1000
Base-T Ethernet interfaces, and
802.11b/g/n/ac Wi-Fi radio with
on/off switch.
This ONT also has 2 USB ports, 1 USB
3.0 and 1 USB 2.0.
Includes 3-pin wall-mounted British
(UK) AC/DC adapter.
———
1 — G-240W-B unit data sheet
1.1 G-240W-B part numbers and identification
Table 1-1 provides part numbers and identification information for the G-240W-B
indoor ONT.
Table 1-1 Identification of G-240W-B indoor ONTs
Table 1-2 provides power supply ordering information about the G-240W-B ONT.
For more
1-2 Alcatel-Lucent 7368 ISAM ONT
UPS Guide.
information
on power supplies, see the 7368 ISAM ONT Power Supply and
Edition 01
G-240W-B Product Guide
Page 39
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
Power model
Power information
Customer category
or country
compliance tested
for
Notes
Mass Power
36 Watt AC/DC power adapter
ANSI municipality
United States,
Canada
1.2 G-240W-B general
G-240W-B indoor ONTs provide the subscriber interface for the network by
terminating the PON interface and converting it to user interfaces that directly
connect to subscriber devices. The ONT is compatible with all existing subscriber
equipment, including analog phones with both tone and rotary dial capabilities,
cordless phones, modems, fax machines, and caller ID boxes (Type I, Type II, and
Alcatel-Lucent 7368 ISAM ONT 1-3
Edition 01
G-240W-B Product Guide
Type III).
G-240W-B indoor ONTs provide the following functions:
•Single fiber GPON interface with 1.244Gbit/s upstream and 2.488Gbit/s
downstream data rates
•Advanced data features such as VLAN tag manipulation, classification, and
filtering.
• Traffic classification and QoS capability
• Analog Telephone Adapter (ATA) function integrated based on SIP (RFC3261)
and H.248, with various CLASS services supported, including Caller ID, Call
Waiting, Call Forwarding, and Call Transfer
• 5 REN per line
• Multiple voice Codec
• MDI/MDIX auto-negotiation
• Line Rate L2 traffic
• Internal Switch
• UPnP IGD1.0 support
• Bridged mode or routed mode per LAN port
• Optics that support received signal strength indication (RSSI)
• Internal DHCP server, with configurable DHCP pool and gateway
• WPS on wireless authorization support
• Configurable Wi-Fi tx power from 100mw to 500mw, in 100mw increments.
• Enhanced ONT; SSH-Telnet-FTP and http server are disabled from the WAN
side
• Concurrent 802.11n 3x3 MIMO in 2.4GHz and 802.11ac 4x4 MIMO in 5GHz
• 64/128 WEP encryption
• WPA, WPA-PSK/TKIP
• WPA2, WPA2-PSK/AES
Table 1-2 G-240W-B power supply
description
1 — G-240W-B unit data sheet
Page 40
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
1 — G-240W-B unit data sheet
•support for multiple SSIDs (private and public instances); contact your ALU
representative for further
details.
• WLAN on/off push button
• WPS/PBC buttons (for 2.4G and 5G)
• Ethernet-based Point-to-Point (PPPoE)
• Network Address Translation (NAT)
• Network Address Port Translation (NAPT)
• ALG and UpnP port forwarding
• DMZ
• IP/MAC filter
• Multi-level firewall
• DNS server
• DHCP client/server
• support for HT40 mode for increased channel bandwidth
• support for up to 20 simultaneous wireless connections
• External USB HD (Hard Drive) support, accessible to all LAN devices
1.3 G-240W-B software and installation feature support
For information on installing or replacing the G-240W-B see:
• Install a G-240W-B indoor ONT
• Replace a G-240W-B indoor ONT
For information on the following topics, see the 7368 ISAM ONT Product Overview
Guide:
• ONT and MDU general descriptions of features and functions
• Ethernet interface specifications
• POTS interface specifications
• RSSI specifications
• Wi-Fi specifications
• ONT optical budget
• SLID entry via Ethernet port
• ONT management using an ONT interface
1.4 G-240W-B interfaces and interface capacity
Table 1-3 describes the supported interfaces and interface capacity for G-240W-B
indoor ONTs.
1-4 Alcatel-Lucent 7368 ISAM ONT
Edition 01
G-240W-B Product Guide
Page 41
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
ONT type
and model
Maximum capacity
POTS
10/
100
BASE-T
10/
100/
1000
BASE-T
RF video
(CATV)
MoCA
VDSL2
E1/T1
Local craft
GPON
SC/
APC
G-240W-B
(1)
2 — 4 — — — — — 1
Connection
(1)
Description
USB ports
This connection is provided through 2 USB ports, 1 USB 3.0 and 1 USB
2.0. The ONT supports external USB hard drives that can be made
accessible to all LAN devices.
Table 1-3 G-240W-B indoor ONT interface connection capacity
Note
(1)
The G-240W-B ONTs provide Wi-Fi service that is enabled and disabled using a Wi-Fi on/off switch.
G-240W-B connections and components
Figure 1-1 shows the physical connections for G-240W-B indoor ONTs,
Figure 1-1 G-240W-B indoor ONT physical connections
USB 3.0 USB 2.0 TEL1 T EL2 LAN1 LAN2 L AN3 LAN4 POWER ON/OFF UPS
USB
ports
POTS
ports (2)
(RJ-11)
Ethernet
ports (4)
(RJ-45)
Wi-Fi
security
buttons (2)
Reset
button
Table 1-4 describes the physical connections for G-240W-B indoor ONTs.
Table 1-4 G-240W-B indoor ONT physical connections
1 — G-240W-B unit data sheet
Wireless
On/Off
button
Power
input
On/Off
button
Fiber
optic
port
24614
(1 of 2)
Alcatel-Lucent 7368 ISAM ONT 1-5
Edition 01
G-240W-B Product Guide
Page 42
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
Connection
(1)
Description
POTS ports
This connection is provided through RJ-11 ports. Up to two POTS
connections are supported.The POTS ports support voice services.
Ethernet ports
This connection is provided through Ethernet RJ-45 connectors. Up to
four 10/100/1000 Base-T Ethernet interfaces are supported.The
Ethernet ports can support both data and in-band video services on all
four interfaces.
WPS buttons
The Wi-Fi Protected Setup buttons are labeled WPS2.4G and WPS5G.
These buttons enable and disable WLAN data encryption.
WLAN button
Wi-Fi service is compliant with IEEE 802.11 standards and is enabled
and disabled using the WLAN button.
Reset button
This button resets the ONT to the factory defaults.
Power input
This connection is provided through the power connector. A power
cable fitted with a barrel connector is used to make the connection.
On/Off button
This button turns the ONT on or off.
1 — G-240W-B unit data sheet
(2 of 2)
Note
(1)
The primary path for the earth ground for these ONTs is provided by the 12V Return signal in the
power connector.
1.5 G-240W-B LEDs
Figure 1-2 shows the G-240W-B indoor ONT LEDs.
Figure 1-2 G-240W-B indoor ONT LEDs
LAN1
LINK AUTH
BTR
POWER
LAN2
POWER BT R LINK AUTH LAN1 LAN2 LAN3 LAN4 T EL1 TEL2 VOIP WPS WPSWLAN WLAN USB INTERN ET
1-6 Alcatel-Lucent 7368 ISAM ONT
Table 1-5 provides LED descriptions for G-240W-B indoor ONTs.
LAN3
LAN4
TEL1
TEL2
VOIP
WPS
2.4G
2.4G5 G 2.4G 5G
WPS
5G
WLAN
2.4G
5G
USB
WLAN
INTERNET
Edition 01
G-240W-B Product Guide
24615
Page 43
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
Indicator
LED color and
behavior
LED behavior description
Power
Green solid
Red solid
Off
Power on
Light failed on startup (for example corrupt flash), or self test failed on startup,
or self test failed during regular operation or when executed over OMCI
Power off
BTR
Off
Green
Battery alarm set or battery not provisioned (not affected by AC power failure)
Battery charged; no battery alarms
Link
Green solid
Off
GPON link between ONT and OLT is operating normally
GPON link is down or no link connected
Auth
Green solid
Green flashing
Off
ONT is authorized
ONT is process of ranging or synchronizing on OMCI
ONT is not authorized
LAN 1 to 4
Green solid
Green flashing
Off
Ethernet is linked
LAN activity is present (in either direction)
ONT power is off or Ethernet is not connected
TEL 1 to 2
Green solid
Green flashing
Off
Off hook
Call in or talking
On hook
VOIP
Green solid
Off
VOIP service is OK
VOIP service is not OK
WPS
2.4G and 5G
Green solid
Green flashing
Off
Wireless LAN link is up
Wireless LAN link activity
Wireless LAN link is down or no link is connected
WLAN
2.4G and 5G
Green solid
Green flashing
Off
Wireless is enabled
There is traffic on wireless interface
Wireless is down or no link is connected
USB
Green solid
Green flashing
Off
At least one USB device is connected
There is traffic activity on at least on USB device
No USB device is connected
INTERNET
Green solid
Green flashing
Off
HSI WAN is connected: a) the device has an IP address assigned from IPCP, DHCP,
or static, and no traffic has been detected; b) the session is dropped due to idle
timeout but the PON link is still present.
PPPoE or DHCP connection in progress
HSI WAN is not connected: a) there is no physical interface connection; b) the
device is in bridged mode without an assigned IP address; c) the session has been
dropped for reasons other than idle timeout.
1 — G-240W-B unit data sheet
Table 1-5 G-240W-B indoor ONT LEDs
1.6 G-240W-B detailed specifications
Alcatel-Lucent 7368 ISAM ONT 1-7
Edition 01
G-240W-B Product Guide
Table 1-6 lists the physical specifications for G-240W-B indoor ONTs.
Page 44
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
2 POTS on-hook, other
interfaces/services not
provisioned
Mounting method
Temperature range and humidity
Altitude
On desk or wall
mounted
Operating: 23°F to 113°F (-5°C to 45°C)
ambient temperature
10% to 90% relative humidity, non-condensing
Contact your Alcatel-Lucent technical support
representative for more information
Storage: Contact your Alcatel-Lucent support
representative for more information
ONT or MDU
Maximum
Notes
Package P ONTs
GEM ports per indoor or
outdoor ONT
64
—
1 — G-240W-B unit data sheet
Table 1-7 lists the power consumption specifications for G-240W-B indoor ONT.
Table 1-7 G-240W-B indoor ONT power consumption specifications
Table 1-6 G-240W-B indoor ONT physical specifications
Table 1-8 lists the environmental specifications for G-240W-B indoor ONT.
Table 1-8 G-240W-B indoor ONT environmental specifications
1.7 G-240W-B GEM ports and T-CONTs
Table 1-9 lists the
maximum
number of
supported T-CONTs
appropriate release Customer Release Notes for the most accurate list of supported
devices.
Table 1-9 G-240W-B indoor ONT capacity for GEM ports and T-CONTs
and GEM ports. See the
(1 of 2)
1-8 Alcatel-Lucent 7368 ISAM ONT
Edition 01
G-240W-B Product Guide
Page 45
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
ONT or MDU
Maximum
Notes
T-CONTs
per
indoor
or outdoor
ONT
32
—
ONT
ONTENET statistics
FCSE
EC LC
RBO
SCF
MCF
DT
IMTE
CSE
AE
IMRE
FTL
TBO
SQE
G-240W-B
(1)
✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
1 — G-240W-B unit data sheet
(2 of 2)
1.8 G-240W-B performance monitoring statistics
The following section identifies the supported performance monitoring statistics for
G-240W-B
ONTs. A check mark indicates the statistic is supported on that ONT. An
empty cell indicates the statistic is not supported. The following tables are
categorized by supported alarm types:
• Table 1-10 provides statistics for ONTENET type counters
• Table 1-11 provides statistics for ONTL2UNI type counters
• Table 1-12 provides statistics for PONONTTC, PONONTMCTC,
PONONTTCHSI, PONONTTCCES, PONONTTCFLOW, and
PONONTTCVOIP type counters
•Table 1-13 provides statistics for PONONTTC aggregate type counters
Note —If you
monitoring statistics using TL1, please contact your Alcatel-Lucent
support representative for more information about how to access and
retrieve performance monitoring type counters.
de la performance G-240W-B ONT utilisant TL1, se il vous plaît
contacter votre représentant de support d'Alcatel-Lucent pour plus
d'informations sur la façon d'accéder et de récupérer des compteurs
de performance de type de surveillance.
have trouble accessing G-240W-B ONTs
Si vous avez des difficultés à accéder statistiques de suivi
Table 1-10 Package P ONTs ONTENET performance monitoring statistics
performance
Note
(1)
A 5 second polling window limitation exists on the ONT, therefore the margin of error for each
15-min window is 5 seconds
Page 46
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
A 5 second polling window limitation exists on the ONT, therefore the margin of error for
15-min window is 5 seconds
Table 1-13 Package P ONTs PONONTTC aggregate performance monitoring statistics
Note
(1)
A 5 second polling window limitation exists on the ONT, therefore the margin of error for
1-10 Alcatel-Lucent 7368 ISAM ONT
15-min window is 5 seconds
each
each
Edition 01
G-240W-B Product Guide
Page 47
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
1 — G-240W-B unit data sheet
1.9 G-240W-B functional blocks
G-240W-B indoor ONTs are single-residence ONTs that support Wireless (Wi-Fi)
service. Wi-Fi service on these ONTs is compliant with the IEEE 802.11 standard
and enabled or
ONTs transmit Ethernet packets to four RJ-45 Ethernet ports and voice traffic to two
RJ-11 POTS ports. These ONTs also feature fiber optic, USB, and power connectors.
Figure 1-3 shows the functional blocks for G-240W-B indoor ONT.
Figure 1-3 Single-residence Wi-Fi ONT with Gigabit Ethernet and POTS and without RF
2xRJ11 FXS
ONT SoC technology serves as the main hardware block for these ONTs; see
Figure 1-4.
Alcatel-Lucent 7368 ISAM ONT 1-11
Edition 01
G-240W-B Product Guide
GPON
NAND
DDR3
disabled
SLIC
using a WLAN button. In
video
PCIe
GPON SoC
GE
GE GEGE
XFMR
4xGE
mux
GE PHY
PCIe
RGMII
addition
to the Wi-Fi service, these
11n PA/LNA
converter
GE
11ac
RAM
ANT
USB3.0
USB2.0
3x3
2.4G
ANT
PA/LNA
4x4, 5G
24674
Page 48
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
1 — G-240W-B unit data sheet
Figure 1-4 G-240W-B ONT hardware block
POTS ports
Control
processor
SoC
DSP
Bridge
SoC
Ethernet
MACs
GPON
MAC
Ethernet
ports GPON
19421
1-12 Alcatel-Lucent 7368 ISAM ONT
ONT SoC technology consists of five key elements:
•GPON MAC
The Gigabit Passive Optical Network Media Access Control (GPON MAC)
element
on the SoC
terminates
the GPON
interface
using an optical
diplexer.
interface supports GPON as described in G.984.3 (GPON TC Layer) ITU
specification.
•Ethernet MAC
The SoC provides up to four GE MACs.
•DSP interface
The Digital Signal Processor (DSP) provides voice processing for 2 POTS lines
with 3-way calling. The DSP has a dedicated 64 kbyte instruction cache and
shares a 32 kbyte data cache with the Control Processor. It provides up to 4
network processor cores, each at 800MHz.
•Control Processor
The Control Processor features an integral memory management unit that
supports a dedicated 64 kbyte instruction cache and shares a single 32 kbyte data
cache with the DSP. The
Control Processor
and DSP also include a single channel
Data Management Application (DMA) controller with a 4 kbyte read ahead
low-latency Dynamic Random Access Memory (DRAM) access port. The
processors typically run at 500 MHz.
•Switch matrix
The Switch matrix provides an integrated data channel between the four GE
MACs, the GPON MAC, the DSP, the control processor, and the other integrated
elements such as flash memory, DRAM, and the local bus controller.
These ONTs can also interact with additional hardware components to support
functionality not provided by the SoC technology.
Edition 01
G-240W-B Product Guide
This
Page 49
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
1 — G-240W-B unit data sheet
1.10 G-240W-B standards compliance
Alcatel-Lucent 7368 ISAM ONT 1-13
Edition 01
G-240W-B Product Guide
G-240W-B indoor ONTs are compliant with the following standards:
• 802.1p marking and VLAN based pbit is supported
• G.711 support for FAX and modem connection
• G.984 support GPON interface (framing)
• G.984.2 support for Amd1, class B+
• G.984.3 support for activation and password functions
• G.984.3 support for AES with operator enable/disable on per port-ID level
• G.984.3 support for FEC in both upstream and downstream directions
• G.984.3 support for multicast using a single GEM Port-ID for all video traffic
• G984.4 and G.983.2 support for OMCI v1 and v2 interface for ONT management
and provisioning
FCC statement
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
•Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement
This device complies with FCC radiation exposure limits set forth for an
uncontrolled environment and it also complies with Part 15 of the FCC RF Rules.
This equipment must be installed and operated in accordance with provided
instructions and the antenna(s) used for this transmitter must be installed to provide
a separation distance of at least 20 cm from all persons and must not be co-located
or operating in conjunction with any other antenna or transmitter. End-users and
installers must be provided with antenna installation instructions and consider
removing the no-collocation statement.
Page 50
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
1 — G-240W-B unit data sheet
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions:
1 this device may not cause harmful interference, and
2 this device must accept any interference received, including interference that
may cause undesired operation.
Caution —Any changes or modifications not expressly approved by
the party
operate the equipment.
approuvés par la partie responsable de la conformité pourraient
annuler l'autorité de l'utilisateur à utiliser l'équipement.
1.11 G-240W-B special
G-240W-B is a package P ONT.
Wi-Fi service
G-240W-B indoor ONTs feature Wi-Fi service as well as voice and data services.
Wi-Fi is a wireless networking technology that uses radio waves to provide wireless
HSI and network connections. This ONT complies with the IEEE 802.11 standards,
which the Wi-Fi Alliance defines as the basis for Wi-Fi technology.
Wi-Fi physical features
G-240W-B
indoor ONTs have the
Wi-Fi service:
• WLAN button for enabling and disabling Wi-Fi service
• two internal antennae
• two Wi-Fi Protected Setup (WPS) push buttons (one each for 2.4G and 5G) for
adding WPS-enabled wireless devices
Wi-Fi standards and certifications
The Wi-Fi service on G-240W-B indoor ONTs supports the following IEEE
standards and Wi-Fi Alliance certifications:
• compliant with IEEE 802.11 standards
• certified for IEEE 802.11b/g/n standards
• WPA support including WPA-PSK
• certified for WPA2-Personal and WPA2-Enterprise
Wi-Fi GUI features
G-240W-B indoor ONTs have HTML-based Wi-Fi configuration GUIs.
G-240W-B ONT considerations and limitations
responsible
for
compliance
could void the user's authority to
Les changements ou modifications non expressément
considerations
following physical features
that assist in providing
Table 1-14 lists the considerations and limitations for Package P G-240W-B ONTs.
1-14 Alcatel-Lucent 7368 ISAM ONT
Page 51
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
Considerations and limitations
Call History Data collection (ONTCALLHST) is supported, except for the following
parameters: RTP
packets (discarded), far-end RTCP and RTCP-XR participation, RTCP average and peak round trip
delay, MOS, average jitter, number of jitter-buffer over-runs and under runs.
Some voice features are configurable on a per ONT basis, including Call Waiting, Call Hold, 3-Way
Calling, and Call Transfer.
The following voice features / GSIP parameters are configurable on a per-Client/ per-ONT basis (not
per-Subscriber):
• Enable Caller ID and Enable Caller Name ID
• Digitmap and the associated Interdigit and Critical timers and Enter key parameters
• Warmline timer is enabled per subscriber, but the warmline timer value is configured per ONT
and must have a lower value than the Permanent time
• Miscellaneous timers: Permanent, Timed-release, Reanswer, Error-tone, and CW-alert timers
• Service Codes for the following features: CCW, Call Hold and Warmline
The Molex interface is not operational.
Table 1-14 G-240W-B ONT considerations and limitations
Alcatel-Lucent 7368 ISAM ONT 1-15
Edition 01
G-240W-B Product Guide
1 — G-240W-B unit data sheet
Page 52
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
2 —Install a G-240W-B indoor ONT
2.1 Purpose 2-2
2.2 General 2-2
2.3 Prerequisites 2-2
2.4 Recommended tools 2-2
2.5 Safety information 2-3
2.6 Procedure 2-4
Alcatel-Lucent 7368 ISAM ONT 2-1
Edition 01
G-240W-B Product Guide
Page 53
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
2 — Install a G-240W-B indoor ONT
2.1 Purpose
This chapter provides the steps to install a G-240W-B indoor ONT.
2.2 General
The steps listed in this chapter describe mounting and cabling for G-240W-B indoor
ONTs.
2.3 Prerequisites
You need the following items before beginning the installation:
•all required cables
2.4 Recommended tools
2-2 Alcatel-Lucent 7368 ISAM ONT
You need the following tools for the installation:
• #2 Phillips screwdriver
• 1/4 in. (6 mm) flat blade screwdriver
• wire strippers
• fiber optic splicing tools
• RJ-45 cable plug crimp tool
• voltmeter or multimeter
• optical power meter
• drill and drill bits
• paper clip
Edition 01
G-240W-B Product Guide
Page 54
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
2.5 Safety information
Read the following safety information before installing the unit.
Danger 1 —Hazardous electrical voltages and currents can cause
serious physical harm or death. Always use insulated tools and follow
proper safety precautions when connecting or disconnecting power
circuits.
Tensions et courants électriques dangereuses peuvent
causer des dommages ou la mort physique grave. Toujours utiliser
des outils isolés et suivre les précautions de sécurité adéquates pour
connecter ou déconnecter les circuits de puissance.
Danger 2 —Make sure all sources of power are turned off and have
no live voltages present on feed lines or terminals. Use a voltmeter to
measure for voltage before proceeding.
Assurez-vous que toutes les sources d'alimentation sont
éteints et ne ont pas de tensions vivants présents sur les lignes
d'alimentation ou de terminaux. Utilisez un voltmètre pour mesurer
la tension avant de procéder.
Danger 3 —Always contact the local utility company before
connecting the enclosure to the utilities.
Toujours contacter la compagnie d'électricité
locale avant de brancher l'enceinte pour les services publics.
Warning — This equipment is ESD sensitive. Proper ESD
protections should be used when removing the fiber access cover of
the indoor ONT.
Cet équipement est sensible ESD. Protections ESD
appropriées doivent être utilisées pour retirer le couvercle de l'ONT
à l'intérieur d'accès en fibre.
Caution — Keep indoor ONTs out of direct sunlight. Prolonged
exposure to direct sunlight can damage the unit.
Gardez ONT intérieur hors du soleil direct. Une
exposition prolongée aux rayons du soleil peut endommager
l'appareil.
Note 1 —Observe the local and national laws and regulations
that may be applicable to this installation.
Respecter les lois et réglementations locales et
nationales qui peuvent être applicables à cette installation.
Note 2 —Observe the following:
•The indoor ONT should be installed in accordance with the
applicable
practices take precedent when there is conflict between the local
standard and the NEC or CEC.
• The indoor ONT must be installed by qualified service personnel.
• Indoor ONTs must be installed with cables that are suitably rated
and listed for indoor use.
•See the
the temperature ranges for these ONTs.
2 — Install a G-240W-B indoor ONT
requirements
detailed specifications
of the NEC or CEC. Local
in the
G-240W-B
Respectez les consignes suivantes:
authorities
and
unit data sheet for
Page 55
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
• L'ONT intérieure doit être installée en conformité avec les
exigences applicables de la NEC ou CEC. Les autorités et les
pratiques locales prennent précédent quand il ya conflit entre la
norme locale et le NEC ou CEC.
• L'ONT intérieure doit être installé par un personnel qualifié.
• ONT intérieure doit être installée avec des câbles qui sont
convenablement évalués et classés pour une utilisation intérieure.
• Voir les spécifications détaillées dans la fiche de données de
l'unité G-240W-B pour les plages de température pour ces ONT.
Alcatel-Lucent 7368 ISAM ONT 2-3
Edition 01
G-240W-B Product Guide
Page 56
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
2 — Install a G-240W-B indoor ONT
2.6 Procedure
Use this procedure to install a G-240W-B indoor ONT.
1 Place the indoor ONT unit:
a On the flat surface, such as a desk; go to step 3.
Note —The G-240W-B cannot be stacked with another ONT or with
other equipment. The ONT mounting requirements are:
• allow a minimum 100 mm clearance above the top cover
• allow a minimum 50 mm clearance from the side vents
• do not place any heat source directly above the top cover or below
the bottom cover
avec d'autres équipements. Les exigences de montage ONT sont:
• Laisser un espace minimum de 100 mm au-dessus du capot
supérieur
• Laisser un espace minimum de 50 mm à partir des prises d'air
• Ne placez pas une source de chaleur directement au-dessus du
capot supérieur ou inférieur à la couverture inférieure
b On a wall, go to step 2.
2 Mount the G-240W-B indoor ONT on a wall.
i The G-240W-B indoor ONT can be mounted in either a horizontal or vertical
position, as shown in Figure 2-1. If possible, mount the ONT on a wall stud.
Figure 2-1 Wall mounting keyholes on G-240W-B indoor ONTs
Keyholes for
vertical
mounting
ii Mark the wall with the location of the mounting holes. These holes should be
the same distance apart as the distance between the centers of the keyholes
on the ONT.
iii Drill the two holes in the wall where the ONT will be mounted and then drive
the mounting screws into the holes.
The recommended length of mounting screw is 1.15 in. (3.8 cm).
Le G-240W-B ne peut être empilé avec un autre ONT ou
latérales
Keyholes for horizontal mounting
RESET
24111
Page 57
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
2 — Install a G-240W-B indoor ONT
Do not drive the screw into the wall
completely.
Leave
approximately
1/8 in.
(6 mm) between the screw head and the wall surface.
iv Slide the wall mount keyholes on the ONT enclosure or fiber storage tray
down over the mounting screws until the ONT is securely seated.
3 Review the connection locations as shown in Figures 2-2.
Figure 2-2 G-240W-B indoor ONT connections (back view)
Wireless
On/Off
USB 3.0 USB 2.0 TEL1 T EL2 LAN1 L AN2 LAN3 L AN4 POWER ON/OFF UPS
USB
ports
POTS
ports (2)
(RJ-11)
Ethernet
ports (4)
(RJ-45)
Wi-Fi
security
buttons (2)
Reset
button
Power
input
On/Off
button
4 Connect the Ethernet cables to the RJ-45 ports; see Figure 2-2 for the location of
the RJ-45 ports.
5 Route the POTS cables directly to the RJ-11 ports as per local practices.
The POTS port to the left is labeled 1 for Line 1 while the port on the right is
labeled 2 for Line 2, as shown in Figure 2-2.
6
Connect
Figure 2-2 for the location of the SC/APC connector.
the fiber optic cable with SC/APC
adapter
into the
SC/APC connector;
Danger —Fiber cables transmit invisible laser light. To avoid eye
damage or blindness, never look directly into fibers, connectors, or
adapters.
Câbles de fibres transmettent la lumière laser invisible.
Pour éviter des lésions oculaires ou la cécité, ne jamais regarder
directement dans les fibres, les connecteurs ou adaptateurs.
Warning — Be careful to maintain a bend radius of no less than 1.5 in.
(3.8 cm) when connecting the fiber optic cable. Too small of a bend
radius in the cable can result in damage to the optic fiber.
Veillez à maintenir un rayon de courbure d'au moins 1,5
po. (3,8 cm) lors de la connexion du câble de fibre optique. Trop petit
d'un rayon de courbure dans le câble peut entraîner des dommages à
la fibre optique.
button
Fiber
optic
port
24614
see
Page 58
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
2 — Install a G-240W-B indoor ONT
Note —Fiber cable preparation varies depending on the type and size
of the inside or outside plant fiber cable being spliced to the SC/APC
fiber optic pigtail cable.
Préparation du câble de fibres varie en fonction du type et de
la taille de l'intérieur ou de câble de fibres de plante extérieur étant
assemblés bord à bord pour la SC/APC câble en queue de cochon à
fibres optiques.
7 Install the power supply according to manufacturer specifications.
Note —Observe the
• Units must be powered by a Listed or CE approved and marked
limited power source power supply with a minimum output rate of
12 V dc, 1.25
• Les unités doivent être alimentés par une alimentation de source
d'alimentation limitée répertoriés ou homologués CE et sont
marqués d'un taux de sortie minimum de 12 V cc, 1,25 A
8 Connect the power cable to the power connector.
9 Power up the ONT unit by using the power switch.
10 If used, enable the Wi-Fi service.
i Locate the WLAN button on the ONT; see Figure 2-2 for location of the WLAN
button.
ii Press the WLAN button to change the status of the Wi-Fi service.
11 Verify the ONT LEDs, voltage status, and optical signal levels; see the 7368
Hardware and Cabling Installation Guide.
12 Activate and test the services; see the 7368 Hardware and Cabling Installation
Guide.
13 If used, configure the SLID; see the 7368 ISAM ONT Configuration, Management,
and Troubleshooting Guide.
14 If necessary, reset the ONT.
i Locate the Reset button on a G-240W-B indoor ONT as shown in Figure 2-2.
ii Insert the end of a straightened paper clip or other narrow object into the
hole in the Reset button to reset the ONT.
15 STOP. This procedure is complete.
following:
A.
Respectez les onsignes
suivantes:
Page 59
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
3 —Replace a G-240W-B indoor ONT
3.1 Purpose 3-2
3.2 General 3-2
3.3 Prerequisites 3-2
3.4 Recommended tools 3-2
3.5 Safety information 3-3
3.6 Procedure 3-4
Alcatel-Lucent 7368 ISAM ONT 3-1
Edition 01
G-240W-B Product Guide
Page 60
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
3 — Replace a G-240W-B indoor ONT
3.1 Purpose
This chapter provides the steps to replace G-240W-B indoor ONTs.
3.2 General
The steps listed in this chapter describe mounting and cabling for G-240W-B indoor
ONTs.
3.3 Prerequisites
You need the following items before beginning the installation:
•all required cables
3.4 Recommended tools
3-2 Alcatel-Lucent 7368 ISAM ONT
You need the following tools for replacing the ONT:
• #2 Phillips screwdriver
• 1/4 in. (6 mm) flat blade screwdriver
• wire strippers
• fiber optic splicing tools
• RJ-45 cable plug crimp tool
• voltmeter or multimeter
• optical power meter
• drill and drill bits
Edition 01
G-240W-B Product Guide
Page 61
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
3.5 Safety information
Read the following safety information before replacing the unit.
Danger 1 —Hazardous electrical voltages and currents can cause
serious physical harm or death. Always use insulated tools and follow
proper safety precautions when connecting or disconnecting power
circuits.
Tensions et courants électriques dangereuses peuvent
causer des dommages ou la mort physique grave. Toujours utiliser
des outils isolés et suivre les précautions de sécurité adéquates pour
connecter ou déconnecter les circuits de puissance.
Danger 2 —Make sure all sources of power are turned off and have
no live voltages present on feed lines or terminals. Use a voltmeter to
measure for voltage before proceeding.
sont éteints et ne ont pas de tensions vivants présents sur les lignes
d'alimentation ou de terminaux. Utilisez un voltmètre pour mesurer
la tension avant de procéder.
Danger 3 —Always contact the local utility company before
connecting the enclosure to the utilities.
locale avant de brancher l'enceinte pour les services publics.
Warning — This equipment is ESD sensitive. Proper ESD
protections should be used when removing the fiber access cover of
the indoor ONT.
appropriées doivent être utilisées pour retirer le couvercle de l'ONT
à l'intérieur d'accès en fibre
Caution — Keep indoor ONTs out of direct sunlight. Prolonged
exposure to direct sunlight can damage the unit.
exposition prolongée aux rayons du soleil peut endommager
l'appareil.
Note 1 —Observe the local and national laws and regulations
that may be applicable to this installation.
Respecter les lois et réglementations locales et
nationales qui peuvent être applicables à cette installation
Note 2 —Observe the following:
•The indoor ONT should be installed in accordance with the
applicable
practices take precedent when there is conflict between the local
standard and the NEC or CEC.
• The indoor ONT must be installed by qualified service personnel.
• Indoor ONTs must be installed with cables that are suitably rated
and listed for indoor use.
•See the
the ONT temperature ranges for these ONTs.
3 — Replace a G-240W-B indoor ONT
Assurez-vous que toutes les sources d'alimentation
Toujours contacter la compagnie d'électricité
Cet équipement est sensible ESD. Protections ESD
Gardez ONT intérieur hors du soleil direct. Une
requirements
detailed specifications
of the NEC or CEC. Local
in the
G-240W-B
unit data sheet for
authorities
Respectez les consignes suivantes:
and
Page 62
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
• L'ONT intérieure doit être installée en conformité avec les
exigences applicables de la NEC ou CEC. Les autorités et les
pratiques locales prennent précédent quand il ya conflit entre la
norme locale et le NEC ou CEC.
• L'ONT intérieure doit être installé par un personnel qualifié.
• ONT intérieure doit être installée avec des câbles qui sont
convenablement évalués et classés pour une utilisation intérieure.
• Voir les spécifications détaillées dans la fiche de données de
l'unité G-240W-B pour les plages de température pour ces ONT
ONT.
Alcatel-Lucent 7368 ISAM ONT 3-3
Edition 01
G-240W-B Product Guide
Page 63
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
3 — Replace a G-240W-B indoor ONT
3.6 Procedure
Use this procedure to replace a G-240W-B indoor ONT.
1 Deactivate the ONT services at the P-OLT.
If you are using the SLID feature, this step is not required. The ONT and the
services can remain in service (IS).
i Use the RTRV-ONT command to verify the ONT status and th associated
services. Record the serial number or the SLID of the ONT displayed in the
command output.
Example:
2 If used, disable the Wi-Fi service by pressing the WLAN button; see Figure 3-1 for
3 Power down the unit by using the on/off power switch.
4
3-4 Alcatel-Lucent 7368 ISAM ONT
RTRV-ONT::ONT-1-1-1-1-1;
ii If the ONT is in service, place the ONT in OOS state.
Example:
ED-ONT::ONT-1-1-1-1-1;
the location of the WLAN button.
Figure 3-1 G-240W-B indoor ONT connections
USB 3.0 USB 2.0 TEL1 T EL2 LAN1 LAN2 L AN3 LAN4 POWER ON/O FF UPS
Disconnect
USB
ports
POTS
ports (2)
(RJ-11)
the POTS,
Ethernet
ports (4)
(RJ-45)
Ethernet,
Reset
button
Wi-Fi
security
buttons (2)
Power
input
and power cables from the ONT; see Figure 3-1 for
the connector locations on the G-240W-B indoor ONT.
Wireless
On/Off
button
On/Off
button
Fiber
optic
port
24614
Edition 01
G-240W-B Product Guide
Page 64
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
3 — Replace a G-240W-B indoor ONT
5 Disconnect the fiber optic cables.
Danger —Fiber cables transmit invisible laser light. To avoid eye
damage or blindness, never look directly into fibers, connectors, or
adapters.
Câbles de fibres transmettent la lumière laser invisible.
Pour éviter des lésions oculaires ou la cécité, ne jamais regarder
directement dans les fibres, connecteurs ou adaptateurs
i Unplug the fiber optic cable with SC/APC connector from the ONT; see
Figure 3-1 for the location of the fiber optic port.
ii Attach a fiber dust cover to the end of the SC/APC connector.
6 Replace the ONT with a new unit:
a On a flat surface, such as a desk, substitute the new ONT for the old ONT on
a flat surface, horizontally resting on its four feet.
b On a wall.
i Slide the old ONT off of the mounting screws until the ONT is free of the
wall.
ii Slide the wall mount holes on the ONT enclosure over the mounting
screws until it is securely seated.
7 Connect the Ethernet cables directly to the RJ-45 ports; see Figure 3-1 for the
location of the RJ-45 ports.
8 Connect the POTS cables directly to the RJ-11 ports as per local practices; see
Figure 3-1 for the location of the RJ-11 ports.
The RJ-11 port to the left is labeled 1 for Line 1 while the port on the right is
labeled 2 for Line 2.
9 If required, have approved service personnel who are trained to work with optic
fiber clean the fiber optic connection. See the 7368 ISAM ONT Configuration, Management, and Troubleshooting Guide for more information about fiber optic
handling, inspection, and cleaning.
damage or blindness, never look directly into fibers, connectors, or
adapters.
Câbles de fibre optique transmettent la lumière laser
invisible. Pour éviter des lésions oculaires ou la cécité, ne jamais
regarder directement dans les fibres, les connecteurs ou adaptateurs.
10 Connect the fiber optic cable with SC/APC adapter into the SC/APC connector.
Figure 3-1shows the location of the SC/APC connector.
Danger —Fiber cables transmit invisible laser light. To avoid eye
damage or blindness, never look directly into fibers, connectors, or
adapters.
Câbles de fibre optique transmettent la lumière laser
invisible. Pour éviter des lésions oculaires ou la cécité, ne jamais
regarder directement dans les fibres, les connecteurs ou adaptateurs.
Warning — Be careful to maintain a bend radius of no less than 1.5 in.
Page 65
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
(3.8 cm) when connecting the fiber optic cable. Too small of a bend
radius in the cable can result in damage to the optic fiber.
Veillez à maintenir un rayon de courbure d'au moins 1,5
po. (3,8 cm) lors de la connexion du câble de fibre optique. Trop petit
d'un rayon de courbure dans le câble peut entraîner des dommages à
la fibre optique.
Alcatel-Lucent 7368 ISAM ONT 3-5
Edition 01
G-240W-B Product Guide
Page 66
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
3 — Replace a G-240W-B indoor ONT
11 Install the power supply according to manufacturer specifications.
12 Connect the power cable to the power connector.
13 Power up the unit by using the power switch.
14 If used, enable the Wi-Fi service by pressing the WLAN button; see Figure 3-1 for
the location of the WLAN button.
15 If used, configure the SLID; see the 7368 ISAM ONT Configuration, Management,
and Troubleshooting Guide for more information.
16 Verify the ONT LEDs, voltage status, and optical signal levels; see the 7368
Hardware and Cabling Installation Guide.
17 Activate and test the services; see the 7368 Hardware and Cabling Installation
Guide.
18 If necessary, reset the ONT.
i Locate the Reset button on a G-240W-B indoor ONT as shown in Figure 3-1.
ii Insert the end of a straightened paper clip or other narrow object into the
hole in the Reset button to reset the ONT.
19 STOP. This procedure is complete.
Note —Fiber cable preparation varies depending on the type and size
of the inside or outside plant fiber cable being spliced to the SC/APC
fiber optic pigtail cable.
Préparation du câble de fibres varie en fonction du type et
de la taille de l'intérieur ou de câble de fibres de plante extérieur
étant assemblés bord à bord pour la SC/APC câble en queue de cochon
à fibres optiques.
Note —Observe the
following:
• Units must be powered by a Listed or CE approved and marked
limited power source power supply with a minimum output rate of
12 V dc, 1.25 A.
Respectez les consignes suivantes:
• Les unités doivent être alimentés par une alimentation de
source d'alimentation limitée répertoriés ou homologués
CE et sont marqués d'un taux de sortie minimum de 12 V
cc, 1,25 A.
Note —A new SLID or the old SLID may be used with the replacement
ONT. If a new SLID is used, the new SLID must also be programmed at
the P-OLT using TL1 or a network manager. If the old SLID is used, no
changes need to be made at the P-OLT; see the operations and
maintenance documentation for the OLT for more details.
Une nouvelle EDTR ou le vieux EDTR peut être utilisé avec
l'ONT de remplacement. Si une nouvelle EDTR est utilisé, le nouveau
EDTR doit également être programmé à la classe P-OLT utilisant TL1
un gestionnaire de réseau. Si l'ancien EDTR est utilisé, aucune
modification ne est à apporter à la classe P-OLT; voir les opérations et
la documentation de maintenance pour le BTA pour plus de détails.
Page 67
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
4 —Configure a G-240W-B indoor
ONT
4.1 General 4-2
4.2 HGU mode GUI configuration 4-2
4.3 SFU mode GUI configuration 4-39
4.4 Operator ID 4-44
Alcatel-Lucent 7368 ISAM ONT 4-1
Edition 01
G-240W-B Product Guide
Page 68
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
4 — Configure a G-240W-B indoor ONT
4.1 General
Please refer to the configuration information provided with your OLT for the
software configuration procedure for a G-240W-B ONT.
For HTTP configuration procedures, please refer to the 7368 ISAM ONT Configuration, Management, and Troubleshooting Guide.
4.2 HGU mode GUI configuration
Use the procedures below to use the web-based GUI for the G-240W-B in HGU
mode. This mode is preset at delivery.
A home gateway unit (HGU) is a home networking device, used as a gateway to
connect devices in the home through fiber to the Internet. An HGU
of features for the home network including routing and firewall capability. By using
the HGU, users can connect all smart equipment in their home, including personal
computers,
set-top boxes, mobile phones, and other consumer electronics devices, to
the Internet.
Login
provides
a variety
Use the procedure below to login to the web-based GUI for the G-240W-B.
Procedure 4-1 Login to web-based GUI
1 Open a web browser and enter the IP address of the ONT in the address bar.
The login window appears.
The default gateway IP address is http://192.168.1.1. You can connect to this IP
address using your web browser after connecting your PC to one of Ethernet ports
of the ONT. The static IP address of your PC must be in the same subnet as the
ONT.
2 Enter your username and password in the Log in window, as shown in Figure 4-1.
The default username and password are printed on the ONT. The default user
name is userAdmin. The default superuser name is adminGPON. Contact
4-2 Alcatel-Lucent 7368 ISAM ONT
Alcatel-Lucent for the superuser password.
Edition 01
G-240W-B Product Guide
Page 69
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
Caution —If you reset the router to recover the default username and
password,
their factory default values.
d'utilisateur et mot de passe par défaut, tous les autres paramètres de
configuration du routeur seront aussi restaurés à leurs valeurs par
défaut d'usine.
Note —If you forget the current username and password, press the
reset button for 5 s and the default values for the username and
password will be recovered at startup.
appuyez sur le bouton de réinitialisation pendant 5 s et les valeurs
par défaut pour le nom d'utilisateur et mot de passe seront
3 Click Login.
4 STOP. This procedure is complete.
Device and connection status
G-240W-B ONTs support the retrieval of a variety of device and connection
information, including:
• device information
• LAN status
• WAN status
• WAN status IPv6
• Home networking information
• Optics module status
récupérés au démarrage.
4 — Configure a G-240W-B indoor ONT
Figure 4-1 Web login window
all other router
Si vous réinitialisez le routeur pour récupérer le nom
Si vous oubliez le nom d'utilisateur et mot de passe actuel,
configuration
settings will also be restored to
Page 70
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
Field
Description
Device Name
Name on the ONT
Vendor
Name of the vendor
Serial Number
Serial number of the ONT
Hardware version
Hardware version of the ONT
Boot version
Boot version of the ONT
Software version
Software version of the ONT
Chipset
Chipset of the ONT
Device Running
Time
Amount of time the device has run since last reset in hours, minutes, and
seconds
4 — Configure a G-240W-B indoor ONT
Procedure 4-2 Device information retrieval
1 Select Status > Device Information from the top-level menu in the GPON Home
Gateway window, as shown in Figure 4-2.
Figure 4-2 Device Information window
Table 4-1 describes the fields in the Device Information window.
2 Click Refresh to update the displayed information.
4-4 Alcatel-Lucent 7368 ISAM ONT
3 STOP. This procedure is complete.
Table 4-1 Device Information parameters
Edition 01
G-240W-B Product Guide
Page 71
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
Field
Description
Wireless Information
Wireless Status
Indicates whether the wireless is on or off
Wireless Channel
Wireless channel number
SSID Name
Name of each SSID
Wireless
Encryption Status
Encryption type used on the wireless connection
Wireless Rx
Packets
Number of packets received on the wireless connection
Wireless Tx
Packets
Number of packets transmitted on the wireless connection
Wireless Rx Bytes
Number of bytes received on the wireless connection
Wireless Tx Bytes
Number of bytes transmitted on the wireless connection
Power
Transmission (mW)
Power of the wireless transmission, in mW
Ethernet Information
Ethernet Status
Indicates whether the Ethernet connection is on or off
Ethernet IP
Address
IP address of the Ethernet connection
4 — Configure a G-240W-B indoor ONT
Procedure 4-3 LAN status retrieval
1 Select Status > LAN Status from the top-level menu in the GPON Home Gateway
window, as shown in Figure 4-3.
Figure 4-3 LAN status window
Table 4-2 describes the fields in the LAN status window.
Table 4-2 LAN status parameters
(1 of 2)
Alcatel-Lucent 7368 ISAM ONT 4-5
Edition 01
G-240W-B Product Guide
Page 72
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
Field
Description
Ethernet Subnet
Mask
Subnet Mask of the Ethernet connection
Ethernet MAC
Address
MAC address of the Ethernet connection
Ethernet Rx
Packets
Number of packets received on the Ethernet connection
Ethernet Tx
Packets
Number of packets transmitted on the Ethernet connection
Ethernet Rx Bytes
Number of bytes received on the Ethernet connection
Ethernet Tx Bytes
Number of bytes transmitted on the Ethernet connection
4 — Configure a G-240W-B indoor ONT
(2 of 2)
2 Click Refresh to update the displayed information.
3 STOP. This procedure is complete.
Procedure 4-4 WAN status retrieval
1 Select Status > WAN Status from the top-level menu in the GPON Home Gateway
window, as shown in Figure 4-4.
Figure 4-4 WAN status window
Table 4-3 describes the fields in the WAN status window.
4-6 Alcatel-Lucent 7368 ISAM ONT
Edition 01
G-240W-B Product Guide
Page 73
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
Field
Description
WAN connection
list
Drop-down menu listing all WAN connections. The connection shown is the
connection for which WAN status will be shown.
Connection Mode
Connection mode of the WAN connection
Enable/Disable
Select this checkbox to enable the WAN connection
VLAN
VLAN ID
WAN Link Status
Whether the WAN link is up or down
Pon Link Status
Whether the PON link is up or down
Tx Packets
Number of packets transmitted on the WAN connection
Rx Packets
Number of packets received on the WAN connection
Tx Dropped
Number of packets dropped on the transmit WAN connection
Rx Dropped
Number of packets dropped on the receive WAN connection
Err Packets
Number of errored packets on the WAN connection
2 Click Refresh to update the displayed information.
Alcatel-Lucent 7368 ISAM ONT 4-7
Edition 01
G-240W-B Product Guide
3 STOP. This procedure is complete.
4 — Configure a G-240W-B indoor ONT
Table 4-3 WAN status parameters
Page 74
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
Field
Description
WAN connection
list
Drop-down menu listing all WAN connections. The connection shown is the
connection for which WAN status will be shown.
Connection Mode
Connection mode of the WAN connection
Enable/Disable
Select this checkbox to enable the WAN connection
VLAN
VLAN ID
WAN Link Status
Whether the WAN link is up or down
IPv6 Address
IPv6 address that identifies the device and its location
Netmask
Network mask
Gateway
Gateway address
Primary DNS
Primary Domain Name Server
Second DNS
Secondary Domain Name Server
Pon Link Status
Whether the PON link is up or down
4 — Configure a G-240W-B indoor ONT
Procedure 4-5 WAN status IPv6 retrieval
1 Select Status > WAN Status IPv6 from the top-level menu in the GPON Home
Gateway window, as shown in Figure 4-5.
Figure 4-5 WAN status IPv6 window
Table 4-4 describes the fields in the WAN status IPv6 window.
4-8 Alcatel-Lucent 7368 ISAM ONT
(1 of 2)
Table 4-4 WAN status IPv6 parameters
Edition 01
G-240W-B Product Guide
Page 75
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
Field
Description
Tx Packets
Number of packets transmitted on the WAN connection
Rx Packets
Number of packets received on the WAN connection
Tx Dropped
Number of packets dropped on the transmit WAN connection
Rx Dropped
Number of packets dropped on the receive WAN connection
Err Packets
Number of errored packets on the WAN connection
Field
Description
Local Interface
Ethernet
Table displays the number of Ethernet connections and their settings
Wireless
Table displays the number of wireless connections and their settings
Wireless Settings
4 — Configure a G-240W-B indoor ONT
(2 of 2)
2 Click Refresh to update the displayed information.
3 STOP. This procedure is complete.
Procedure 4-6 Home networking information retrieval
1 Select Status > Home Networking from the top-level menu in the GPON Home
Gateway window, as shown in Figure 4-6.
Figure 4-6 Home networking information window
Table 4-5 describes the fields in the Home networking window.
(1 of 2)
Alcatel-Lucent 7368 ISAM ONT 4-9
Edition 01
G-240W-B Product Guide
Table 4-5 Home networking parameters
Page 76
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
Field
Description
Network Name
Name of the wireless network
Access Point
Hexadecimal address of the wireless access point
Local Devices
Table entry
Each entry indicates the connection type, device name, IP address, hardware
address, and IP address allocation of each connected local device.
Field
Description
Laser Bias Current (ONT ANI-ONT-Side Optical
Measurements)
Laser bias current, measured in uA
Optics Module Voltage (ONT ANI-ONT-Side Optical
Measurements)
Optics module voltage, measured in V
4 — Configure a G-240W-B indoor ONT
(2 of 2)
2 Click Delete to delete a particular local device connection.
3 Click Refresh to update the displayed information.
4 STOP. This procedure is complete.
Procedure 4-7 Optics module status retrieval
1 Select Status > Optics Module Status from the top-level menu in the GPON
Gateway window, as shown in Figure 4-7.
Figure 4-7 Optics module status window
Home
Table 4-6 describes the fields in the Optics module status window.
Table 4-6 Optics module status parameters
(1 of 2)
4-10 Alcatel-Lucent 7368 ISAM ONT
Edition 01
G-240W-B Product Guide
Page 77
R05.01.01 | December 2014 | 3FE-56678-AAAA-TCZZA | Edition 01
Field
Description
Optics Module Temperature (ONT ANI-ONT-Side
Optical Measurements)
Optics module temperature, measured in
C
Rx Optics Signal Level at 1490 nm (ONT ANI-ONT-Side
Optical Measurements)
Received optics signal level at 1490 nm,
measured in dBm
Tx Optics Signal Level at 1310 nm (ONT ANI-ONT-Side
Optical Measurements)