Alcatel-Lucent assumes no responsibility for the accuracy of the information presented, which is
subject to change without notice.
Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All
other trademarks are the property of their respective owners.
Copyright 2008 Alcatel-Lucent.
All rights reserved.
Disclaimers
Alcatel-Lucent products are intended for commercial uses. Without the appropriate network design
engineering, they must not be sold, licensed or otherwise distributed for use in any hazardous
environments requiring fail-safe performance, such as in the operation of nuclear facilities, aircraft
navigation or communication systems, air traffic control, direct life-support machines, or weapons
systems, in which the failure of products could lead directly to death, personal injury, or severe physical
or environmental damage. The customer hereby agrees that the use, sale, license or other distribution
of the products for any such application without the prior written consent of Alcatel-Lucent, shall be at
the customer's sole risk. The customer hereby agrees to defend and hold Alcatel-Lucent harmless from
any claims for loss, cost, damage, expense or liability that may arise out of or in connection with the
use, sale, license or other distribution of the products in such applications.
This document may contain information regarding the use and installation of non-Alcatel-Lucent
products. Please note that this information is provided as a courtesy to assist you. While Alcatel-Lucent
tries to ensure that this information accurately reflects information provided by the supplier, please refer
to the materials provided with any non-Alcatel-Lucent product and contact the supplier for
confirmation. Alcatel-Lucent assumes no responsibility or liability for incorrect or incomplete
information provided about non-Alcatel-Lucent products.
However, this does not constitute a representation or warranty. The warranties provided for
Alcatel-Lucent products, if any, are set forth in contractual documentation entered into by
Alcatel-Lucent and its customers.
This document was originally written in English. If there is any conflict or inconsistency between the
English version and any other version of a document, the English version shall prevail.
When printed by Alcatel-Lucent, this document is printed on recycled paper.
Preface
Scope
Audience
This preface provides general information about the documentation set for the
7342 ISAM Fiber to the User (7342 ISAM FTTU) optical network terminals
(ONTs).
This documentation set provides information about safety, features and
functionality, ordering, hardware installation and maintenance, and software
installation procedures for the current release.
This documentation set is intended for planners, administrators, operators, and
maintenance personnel involved in installing, upgrading, or maintaining the
7342 ISAM FTTU ONTs.
Required knowledge
The reader must be familiar with general telecommunications principles.
Acronyms and initialisms
The expansions and optional descriptions of most acronyms and initialisms appear
in the glossary.
Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06July 2008 iii
3FE 51892 AAAA TCZZAEdition 01 ONT Product Information Manual
Preface
Assistance and ordering phone numbers
Alcatel-Lucent provides global technical support through regional call centers.
Phone numbers for the regional call centers are available at the following URL:
www1.alcatel-lucent.com/comps/pages/carrier_support.jhtml
For technical assistance within North America, call 1-888-252-2832. If calling from
outside North America, call 1-613-784-6100.
For ordering information, contact your Alcatel-Lucent sales representative.
.
Alcatel-Lucent quality processes
Alcatel-Lucent’s 7342 ISAM Fiber to the User (7342 ISAM FTTU) optical network
terminals (ONTs) manufacturing, testing, and inspecting practices are in compliance
with GR-1252-CORE and TL 9000 requirements. These requirements are
documented in the Operations Quality Plan 8BD000234204QRZZA and the
Alcatel-Lucent North American Quality Manual 8BD000010000QRZZA.
The quality plans and practices adequately ensure that technical requirements and
customer end-point requirements are met. The customer or its representatives may
be allowed to perform on-site quality surveillance audits, as agreed upon during
contract negotiations.
Safety information
For ETSI and ANSI safety information, see the appropriate safety guidelines
chapters.
Special information
The following are examples of how special information is presented in this
document.
Danger — Danger indicates that the described activity or situation
may result in serious personal injury or death; for example, high
voltage or electric shock hazards.
Warning — Warning indicates that the described activity or situation
may, or will, cause equipment damage or serious performance
problems.
Caution — Caution indicates that the described activity or situation
may, or will, cause service interruption.
ivJuly 2008Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06
ONT Product Information Manual Edition 013FE 51892 AAAA TCZZA
Note — A note provides information that is, or may be, of special
interest.
Procedures with options or substeps
When there are options in a procedure, they are identified by letters. When there are
required substeps in a procedure, they are identified by roman numerals.
Procedure 1 Example of options in a procedure
At step 1, you can choose option a or b. At step 2, you must do what the step indicates.
1This step offers two options. You must choose one of the following:
aThis is one option.
bThis is another option.
2You must perform this step.
Preface
Procedure 2 Example of required substeps in a procedure
At step 1, you must perform a series of substeps within a step. At step 2, you must do
what the step indicates.
1This step has a series of substeps that you must perform to complete the step. You
must perform the following substeps:
iThis is the first substep.
iiThis is the second substep.
iiiThis is the third substep.
2 You must perform this step.
Multiple PDF document search
You can use Adobe Reader Release 6.0 and later to search multiple PDF files for a
common term. Adobe Reader displays the results in a single display panel. The
results are grouped by PDF file, and you can expand the entry for each file.
Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06July 2008 v
3FE 51892 AAAA TCZZAEdition 01 ONT Product Information Manual
Preface
Note — The PDF files in which you search must be in the same
folder.
Procedure 3 To search multiple PDF files for a common term
1Open Adobe Acrobat Reader.
2Choose Edit→Search from the Acrobat Reader main menu. The Search PDF panel
appears.
3Enter the search criteria.
4Click on the All PDF Documents In radio button.
5Select the folder in which to search using the drop-down menu.
6Click on the Search button.
Acrobat Reader displays the search results. You can expand the entries for each
document by clicking on the + symbol.
viJuly 2008Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06
ONT Product Information Manual Edition 013FE 51892 AAAA TCZZA
ANSI ONT safety guidelines
This chapter provides information about the mandatory regulations that govern the
installation and operation of the 7342 ISAM FTTU optical network terminals
(ONTs).
Safety instructions
This section describes the safety instructions that are provided in the
7342 ISAM FTTU ONT customer documentation and on the equipment.
Safety instruction boxes
The safety instruction boxes are provided in the 7342 ISAM FTTU ONT customer
documentation. Observe the instructions to meet safety requirements.
The following is an example of the Danger box.
Danger — Possibility of personal injury.
The Danger box indicates that the described activity or situation may pose a threat to
personal safety. It calls attention to a situation or procedure which, if not correctly
performed or adhered to, may result in death or serious physical harm.
Do not proceed beyond a Danger box until the indicated conditions are fully
understood and met.
The following is an example of the Warning box.
Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06July 2008 vii
3FE 51892 AAAA TCZZAEdition 01 ONT Product Information Manual
ANSI ONT safety guidelines
The Warning box indicates that the described activity or situation may, or will, cause
equipment damage, loss of data, or serious performance problems. It identifies a
possible equipment-damaging situation or provides essential information to avoid
the degradation of system operations or data.
Do not proceed beyond a warning until the indicated conditions are fully understood
and met.
The following is an example of the Caution box.
The Caution box indicates that the described activity or situation may, or will, cause
service interruption.
Do not proceed beyond a caution until the indicated conditions are fully understood
and met.
Warning 1 — Possibility of equipment damage.
Warning 2 — Possibility of data loss.
Caution 1 — Possibility of service interruption.
Caution 2 — Service interruption.
The following is an example of the Note box.
Note — Information of special interest.
The Note box provides information that assists the personnel working with
7342 ISAM FTTU ONTs. It does not provide safety-related instructions.
Safety-related labels
The ONT equipment is labeled with specific safety compliance information and
instructions that are related to a variant of the ONT. Observe the instructions on the
safety labels.
Table 1 provides examples of the text in the various ONT safety labels.
Table 1 Safety labels
DescriptionLabel text
UL complianceCommunication service equipment US listed. Type 3R enclosure -
TUV complianceType 3R enclosure - Rainproof.
ESD warningCaution: This assembly contains electrostatic sensitive device.
Rainproof.
(1 of 2)
viiiJuly 2008Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06
ONT Product Information Manual Edition 013FE 51892 AAAA TCZZA
ANSI ONT safety guidelines
3
DescriptionLabel text
Laser classificationClass 1 laser product
Laser product complianceThis laser product conforms to all applicable standards of 21 CFR
1040.10 at date of manufacture.
Laser product complianceComplies with 21 CFR 1040.10 and 1040.11 except for deviations
pursuant to laser notice no. 50, dated July 26, 2001.
FCC standards complianceTested to comply with FCC standards for home or office use.
Operation conditionsThis device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any
interference received, including interference that may cause
undesired operation.
Canadian standard
This Class A digital apparatus complies with Canadian ICES-003.
compliance (modular ONT)
Canadian standard
This Class B digital apparatus complies with Canadian ICES-003.
compliance (outdoor ONT)
CE markingThere are various CE symbols for CE compliance.
(2 of 2)
Figure 1 shows a sample safety label on the ONT equipment.
Figure 1 Safety label on the ONT equipment
Tested to Comply
with FCC Standards
FOR HOME OR OFFICE USE
COMMUNICATION SERVICE EQUIPMENT
US LISTED
®
c
27FY
Type 3R Enclosure - Rainproof
This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
This Class A digital apparatus complies with Canadian ICES-003. Cet appareil
numerique de la class A est conforme a la norme NMB-003 du Canada
This Assembly Contains Electrostatic Sensitive Devices
CAUTION
Safety standards compliance
This section describes the ONT compliance with North American safety standards.
1853
Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06July 2008 ix
3FE 51892 AAAA TCZZAEdition 01 ONT Product Information Manual
ANSI ONT safety guidelines
EMC, EMI, and ESD standards compliance
The ONT equipment complies with the following requirements:
•Federal Communications Commission (FCC) CFR 47, Part 15, Subpart B, Class
A requirements for OLT equipment
•GR-1089-CORE requirements, including:
Equipment safety standard compliance
The ONT equipment complies with the requirements of UL60950-1, Safety of
Information Technology Equipment.
Environmental standards compliance
The ONT equipment complies with the following standards:
•Section 3 Electromagnetic Interference, Emissions Radiated and Conducted
•Section 3 Immunity, Radiated and Conducted
•Section 2 ESD Discharge Immunity: System Level Electrostatic Discharge and EFT
Immunity: Electrically Fast Transients
•GR-63-CORE (NEBS): requirements related to operating, storage, humidity,
altitude, earthquake, office vibration, transportation and handling, fire resistance
and spread, airborne contaminants, illumination, and acoustic noise
•GR-487-CORE: requirements related to rain, chemical, sand, and dust
•GR-487 R3-82: requirements related to condensation
•GR-3108: Requirements for Network Equipment in the Outside Plant (OSP)
•TP76200: Common Systems Equipment Interconnec tio ns Standards
Laser product standards compliance
The ONT equipment complies with 21 CFR 1040.10/21 CFR 1040.11, 21 CFR
utilizing Laser Notice No. 50 or CDRH Laser Notice 42 of the regulations for lasers
and laser products by the U.S. Center for Devices and Radiological Health (CDRH)
of the Food and Drug Administration (FDA).
Resistibility requirements compliance
The ONT equipment complies with the requirements of ITU Recommendation K.21
for resistibility of telecommunication equipment installed in customer premises to
overvoltage and overcurrents.
Electrical safety guidelines
This section provides the electrical safety guidelines for the ONT equipment.
xJuly 2008Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06
ONT Product Information Manual Edition 013FE 51892 AAAA TCZZA
ANSI ONT safety guidelines
Note — The ONTs comply with the U.S. National Electrical Code.
However, local electrical authorities have jurisdiction when there are
differences between the local and U.S. standards.
Power supplies
The use of any non-Alcatel-Lucent approved power supplies or power adaptors is not
supported or endorsed by Alcatel-Lucent. Such use will void any warranty or support
contract with Alcatel-Lucent. Such use greatly increases the danger of damage to
equipment or property.
Cabling
The following are the guidelines regarding cables used for the ONT equipment:
•Use only cables approved by the relevant national electrical code.
•Use cables suitable for outdoor use for outdoor installation of ONTs.
•The ONTs have been evaluated for use with external POTS wiring without
primary protection that may not exceed 140 ft (43 m) in reach. However, the
power cable must not exceed 100 ft (31 m).
Protective earth
Earthing and bonding of the ONTs must comply with the requirements of NEC
article 250 or local electrical codes.
ESD safety guidelines
The ONT equipment is sensitive to ESD. Operations personnel must observe the
following ESD instructions when they handle the ONT equipment.
Caution — This equipment is ESD sensitive. Proper ESD protections
should be used when entering the TELCO Access portion of the ONT.
During installation and maintenance, service personnel must wear wrist straps to
prevent damage caused by ESD.
Alcatel-Lucent recommends that you prepare the site before you install the ONT
equipment. In addition, you must control relative humidity, use static dissipating
material for furniture or flooring, and restrict the use of air conditioning.
Laser safety guidelines
Only qualified service personnel who are extremely familiar with laser radiation
hazards should install or remove the fiber optic cables and units in this system.
Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06July 2008 xi
3FE 51892 AAAA TCZZAEdition 01 ONT Product Information Manual
ANSI ONT safety guidelines
5
2
Observe the following warnings when you perform installation, operations, and
maintenance tasks on the ONT equipment.
Observe the following danger for a laser hazard. Eyes can be damaged when they are
exposed to a laser beam. Take necessary precautions before you plug in the optical
modules.
Laser warning labels
The following figures show the labels related to laser product, classification and
warning.
Figure 2 shows a laser product label.
Danger — There may be invisible laser radiation at the fiber optic
cable when the cable is removed from the connector. Avoid direct
exposure to beam.
Danger — Possibility of equipment damage. Risk of eye damage by
laser radiation.
Figure 2 Laser product label
Figure 3 shows a laser classification label. Laser classification labels may be
provided in other languages.
Figure 3 Laser classification label
CLASS 1 LASER PRODUCTPRODUCTO LASER CLASE 1
'
1845
'
xiiJuly 2008Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06
ONT Product Information Manual Edition 013FE 51892 AAAA TCZZA
LASER CLASSE 1CLASE 1 DEL LASER
1899
ANSI ONT safety guidelines
3
Figure 4 shows a laser warning label and an explanatory label for laser products.
Explanatory labels may be provided in other languages. The explanatory label
provides the following information:
•a warning that calls attention to the invisible laser radiation
•an instruction against staring into the beam or viewing directly with optical
instruments
•wavelength
•normal output power
•maximum output power
Figure 4 Laser warning labels
INVISIBLE LASER RADIATION
DO NOT STARE INTO BEAM
OR VIEW DIRECTLY WITH
OPTICAL INSTRUMENTS
Wavelength(s): xxxx nm
Normal output power: xx m W
Max output power: yyy m W
Laser Warning Label
CLASS 1 LASER PRODUCT
RAYONNEMENT LASER CLASSE 1
RAYONNEMENT LASER INVISIBLE
'
NE PAS DEMONTER. FAIRE APPEL A UN PERSONNELL QUALIFIE
RADIACION DE LASER INVISIBLE. EVITAR CUALOUIER EXPOSICION AL
RAYO LASER. NO DESMONTAR. LLAMAR A PERSONAL AUTORIZADO
INVISIBLE LASER RADIATION PRESENT AT FIBER OPTIC CABLE
WHEN NOT CONNECTED. AVOID DIRECT EXPOSURE TO BEAM.
EVITER TOUTE EXPOSITION AU FAISCEAU
CLASE 1 DEL LASER
Laser Warning Label
Laser Warning Label
Laser classification
The ONT is classified as a Class 1 laser product based on its transmit optical output.
For Class 1 laser products, lasers are safe under reasonably foreseeable conditions of
operation, including the use of optical instruments for intrabeam viewing.
1899
Figure 5 shows a sample laser product safety label on the ONT equipment.
Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06July 2008 xiii
3FE 51892 AAAA TCZZAEdition 01 ONT Product Information Manual
ANSI ONT safety guidelines
2
Transmit optical output
The maximum transmit optical output of an ONT is +5 dBm.
Normal laser operation
In normal operation, fiber cable laser radiation is always off until it receives signal
from the line terminal card.
Figure 5 Laser product safety label on the ONT equipment
CLASS 1 LASER PRODUCT
THIS LASER PRODUCT CONFORMS TO ALL APPLICABLE
STANDARDS OF 21 CFR 1040.10 AT DATE OF MANUFACTURE.
MANUFACTURED:
MONTHYEAR
1853
Operating personnel must observe the instructions on the laser explanatory label
before plugging in the optical module.
Danger — Risk of eye damage by laser radiation.
Location class
Use cable supports and guides to protect the receptacles from strain.
Environmental requirements
See the ONT technical specification documentation for temperature ranges for
ONTs.
During operation in the supported temperature range, condensation inside the ONT
caused by humidity is not an issue. To avoid cond en satio n cau sed by rapid chan ges
in temperature and humidity, Alcatel-Lucent recommends:
•The door of the ONT not be opened until temperature inside and outside the
enclosure has stabilized.
•If the door of the ONT must be opened after a rapid change in temperature or
humidity, use a dry cloth to wipe down the metal interior to prevent the risk of
condensation.
•When high humidity is present, installation of a cover or tent over the ONT helps
prevent condensation when the door is opened.
xivJuly 2008Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06
ONT Product Information Manual Edition 013FE 51892 AAAA TCZZA
ETSI ONT safety guidelines
This chapter provides information about the mandatory regulations that govern the
installation and operation of the 7342 ISAM FTTU optical network terminals
(ONTs).
Safety instructions
This section describes the safety instructions that are provided in the
7342 ISAM FTTU ONT customer documentation and on the equipment.
Safety instruction boxes
The safety instruction boxes are provided in the 7342 ISAM FTTU ONT customer
documentation. Observe the instructions to meet safety requirements.
The following is an example of the Danger box.
Danger — Possibility of personal injury.
The Danger box indicates that the described activity or situation may pose a threat to
personal safety. It calls attention to a situation or procedure which, if not correctly
performed or adhered to, may result in death or serious physical harm.
Do not proceed beyond a Danger box until the indicated conditions are fully
understood and met.
The following is an example of the Warning box.
Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06July 2008 xv
3FE 51892 AAAA TCZZAEdition 01 ONT Product Information Manual
ETSI ONT safety guidelines
The Warning box indicates that the described activity or situation may, or will, cause
equipment damage, loss of data, or serious performance problems. It identifies a
possible equipment-damaging situation or provides essential information to avoid
the degradation of system operations or data.
Do not proceed beyond a warning until the indicated conditions are fully understood
and met.
The following is an example of the Caution box.
The Caution box indicates that the described activity or situation may, or will, cause
service interruption.
Do not proceed beyond a caution until the indicated conditions are fully understood
and met.
Warning 1 — Possibility of equipment damage.
Warning 2 — Possibility of data loss.
Caution 1 — Possibility of service interruption.
Caution 2 — Service interruption.
The following is an example of the Note box.
Note — Information of special interest.
The Note box provides information that assists the personnel working with
7342 ISAM FTTU ONTs. It does not provide safety-related instructions.
Safety-related labels
The ONT equipment is labeled with the specific safety instructions and compliance
information that is related to a variant of the ONT. Observe the instructions on the
safety labels.
Table 2 provides sample safety labels on the ONT equipment.
Table 2 Safety labels
DescriptionLabel text
ESD warningCaution: This assembly contains an electrostatic sensitive device.
Laser classificationClass 1 laser product
CE markingCE declaration of conformity
Figure 6 shows the CE declaration of conformity for the ONT equipment.
xviJuly 2008Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06
ONT Product Information Manual Edition 013FE 51892 AAAA TCZZA
ETSI ONT safety guidelines
3
Figure 6 CE declaration of conformity on the ONT equipment
No101
Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06July 2008 xvii
3FE 51892 AAAA TCZZAEdition 01 ONT Product Information Manual
ETSI ONT safety guidelines
Safety standards compliance
This section describes the ONT compliance with the European safety standards.
EMC, EMI, and ESD compliance
The ONT equipment complies with the following EMC, EMI, and ESD
requirements:
•EN 300-386 V1.3.2 (2003-05): Electromagnetic Compatibility and Radio
•EN 55022 (1998): Class B, Information Technology Equipment, Radio
Disturbance Characteristics, limits and methods of measurement
•EN 55024 (1998): Information Technology Equipment, Immunity
Characteristics, limits and methods of measurement
Equipment safety standard compliance
The ONT equipment complies with the requirements of EN 60950-1, Safety of
Information Technology Equipment for use in a restricted location (per R-269).
Environmental standard compliance
The ONT equipment complies with the EN 300 019 European environmental
standards.
Laser product standard compliance
The ONT equipment complies with EN 60825-1 and IEC 60825-2 for laser products.
Resistibility requirements compliance
The ONT equipment complies with the requirements of ITU Recommendation K.20
and K.21 for resistibility of telecommunication equipment installed in customer
premises to overvoltage and overcurrents.
Acoustic noise emission standard compliance
The ONT equipment complies with EN 300 753 acoustic noise emission limit and
test methods.
Electrical safety guidelines
This section provides the electrical safety guidelines for the ONT equipment.
xviiiJuly 2008Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06
ONT Product Information Manual Edition 013FE 51892 AAAA TCZZA
ETSI ONT safety guidelines
Note 1 — The ONTs comply with the U.S. National Electrical Code.
However, local electrical authorities have jurisdiction when there are
differences between the local and U.S. standards.
Note 2 — The ONTs comply with BS EN 61140.
Power supplies
The use of any non-Alcatel-Lucent approved power supplies or power adaptors is not
supported or endorsed by Alcatel-Lucent. Such use will void any warranty or support
contract with Alcatel-Lucent. Such use greatly increases the danger of damage to
equipment or property.
Cabling
The following are the guidelines regarding cables used for the ONT equipment:
•All cables must be approved by the relevant national electrical code.
•The cables for outdoor installation of ONTs must be suitable for outdoor use.
•The ONTs must be evaluated for use with external POTS wiring without primary
protection that may not exceed 140 ft (43 m) in reach. However, the power cable
must not exceed 100 ft (31 m).
Protective earth
Earthing and bonding of the ONTs must comply with the requirements of local
electrical codes.
ESD safety guidelines
The ONT equipment is sensitive to ESD. Operations personnel must observe the
following ESD instructions when they handle the ONT equipment.
Caution — This equipment is ESD sensitive. Proper ESD protections
should be used when you enter the TELCO Access portion of the
ONT.
During installation and maintenance, service personnel must wear wrist straps to
prevent damage caused by ESD.
Laser safety guidelines
Observe the following instructions when you perform installation, operations, and
maintenance tasks on the ONT equipment.
Only qualified service personnel who are extremely familiar with laser radiation
hazards should install or remove the fiber optic cables and units in this system.
Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06July 2008 xix
3FE 51892 AAAA TCZZAEdition 01 ONT Product Information Manual
ETSI ONT safety guidelines
5
Observe the following danger for laser hazard. Eyes can be damaged when they are
exposed to a laser beam. Take necessary precautions before you plug in the optical
modules.
Laser classification
The ONT is classified as a Class 1 laser product based on its transmit optical output.
Laser warning labels
The following figures show the labels related to laser product, classification and
warning.
Danger — There may be invisible laser radiation at the fiber optic
cable when the cable is removed from the connector. Avoid direct
exposure to the laser beam.
Danger — Possibility of equipment damage. Risk of eye damage by
laser radiation.
Figure 7 shows a laser product label.
Figure 7 Laser product label
Figure 8 shows a laser classification label. Laser classification labels may be
provided in other languages.
1845
xxJuly 2008Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06
ONT Product Information Manual Edition 013FE 51892 AAAA TCZZA
Figure 8 Laser classification label
2
ETSI ONT safety guidelines
CLASS 1 LASER PRODUCTPRODUCTO LASER CLASE 1
'
LASER CLASSE 1CLASE 1 DEL LASER
'
1899
Figure 9 shows a laser warning label and an explanatory label for laser products.
Labels and warning may be provided in other languages. The explanator y label
provides the following information:
•a warning that calls attention to the invisible laser radiation
•an instruction against staring into the beam or viewing directly with optical
instruments
•wavelength
•normal output power
•maximum output power
Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06July 2008 xxi
3FE 51892 AAAA TCZZAEdition 01 ONT Product Information Manual
ETSI ONT safety guidelines
3
Figure 9 Laser warning labels
INVISIBLE LASER RADIATION
DO NOT STARE INTO BEAM
OR VIEW DIRECTLY WITH
OPTICAL INSTRUMENTS
Wavelength(s): xxxx nm
Normal output power: xx m W
Max output power: yyy m W
Laser Warning Label
CLASS 1 LASER PRODUCT
RAYONNEMENT LASER CLASSE 1
RAYONNEMENT LASER INVISIBLE
'
NE PAS DEMONTER. FAIRE APPEL A UN PERSONNELL QUALIFIE
RADIACION DE LASER INVISIBLE. EVITAR CUALOUIER EXPOSICION AL
RAYO LASER. NO DESMONTAR. LLAMAR A PERSONAL AUTORIZADO
INVISIBLE LASER RADIATION PRESENT AT FIBER OPTIC CABLE
WHEN NOT CONNECTED. AVOID DIRECT EXPOSURE TO BEAM.
EVITER TOUTE EXPOSITION AU FAISCEAU
CLASE 1 DEL LASER
Laser Warning Label
Laser Warning Label
Transmit optical output
The maximum transmit optical output of an ONT is +5 dBm.
Normal laser operation
1899
In normal operation, fiber cable laser radiation is always off until it receives signal
from the line terminal card.
Eyes can be damaged when they exposed to a laser beam. Operating personnel must
observe the instructions on the laser explanatory label before plugging in the optical
module.
Danger — Risk of eye damage by laser radiation.
Location class
Use cable supports and guides to protect the receptacles from strain.
xxiiJuly 2008Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06
ONT Product Information Manual Edition 013FE 51892 AAAA TCZZA
ETSI ONT safety guidelines
Environmental requirements
See the ONT technical specification documentation for more information about
temperature ranges.
During operation in the supported temperature range, condensation inside the ONT
caused by humidity is not an issue. To avoid cond en satio n cau sed by rapid chan ges
in temperature and humidity, Alcatel-Lucent recommends:
•The door of the ONT not be opened until temperature inside and outside the
enclosure has stabilized.
•If the door of the ONT must be opened after a rapid change in temperature or
humidity, use a dry cloth to wipe down the metal interior to prevent the risk of
condensation.
•When high humidity is present, installation of a cover or tent over the ONT helps
prevent condensation when the door is opened.
Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06July 2008 xxiii
3FE 51892 AAAA TCZZAEdition 01 ONT Product Information Manual
ETSI ONT safety guidelines
xxivJuly 2008Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06
ONT Product Information Manual Edition 013FE 51892 AAAA TCZZA
ETSI environmental and CRoHS guidelines
This chapter provides information about the ETSI environmental China Restriction
of Hazardous Substances (CRoHS) regulations that govern the installation and
operation of the 7342 ISAM FTTU packet optical line termination (P-OLT) and
Optical Network Termination (ONT) systems. This chapter also includes
environmental operation parameters of general interest.
Environmental labels
This section describes the environmental instructions that are provided in the
7342 ISAM FTTU customer documentation, equipment, and location where the
equipment resides.
Overview
CRoHS is applicable to Electronic Information Products (EIP) manufactured or sold
and imported in the territory of the mainland of the People’s Republic of China. EIP
refers to products and their accessories manufactured by using electronic information
technology, including electronic communications products and such subcomponents
as batteries and cables.
Environmental related labels
Environmental labels are located on appropriate equipment. The following are
sample labels.
Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06July 2008 xxv
3FE 51892 AAAA TCZZAEdition 01 ONT Product Information Manual
ETSI environmental and CRoHS guidelines
6
Products below Maximum Concentration Value (MCV) label
Figure 10 shows the label that indicates a product is below the maximum
concentration value, as defined by standard SJ/T11363-2006 (Requirements for
Concentration Limits for Certain Hazardous Substances in Electronic Information
Products). Products with this label are recyclable. The label may be found in this
documentation or on the product.
Figure 10 Products below MCV value label
1898
Products containing hazardous substances above Maximum Concentration
Value (MCV) label
Figure 11 shows the label that indicates a product is above the maximum
concentration value, as defined by standard SJ/T11363-2006 (Requirements for
Concentration Limits for Certain Hazardous Substances in Electronic Information
Products). The number contained inside the label indicates the
Environment-Friendly User Period (EFUP) value. The label may be found in this
documentation or on the product.
xxviJuly 2008Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06
ONT Product Information Manual Edition 013FE 51892 AAAA TCZZA
ETSI environmental and CRoHS guidelines
5
Figure 11 Products above MCV value label
1898
Together with major international telecommunications equipment companies,
Alcatel-Lucent has determined it is appropriate to use an EFUP of 50 years for
network infrastructure equipment and EFUP of 20 years for handsets and
accessories. These values are based on manufacturers' extensive practical experience
of the design, manufacturing, maintenance, usage conditions, oper ating
environments and physical condition of infrastructure and handsets after years of
service. The values reflect minimum values and refer to products operated according
to the intended use conditions. See “Hazardous Substances Table (HST)” for more
information.
Hazardous Substances Table (HST)
This section describes the compliance of the P-OLT and ONT equipment to the
CRoHS standard when the product and subassemblies contain hazardous substances
beyond the MCV value. This information is found in this user documentation where
part numbers for the product and subassemblies are listed. It may be referenced from
ordering information in other P-OLT and ONT documentation.
The HST document for P-OLT and ONT equipment is available from the following
locations.
Observe the following requirements when handling the P-OLT or ONT equipment.
Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06July 2008 xxvii
3FE 51892 AAAA TCZZAEdition 01 ONT Product Information Manual
ETSI environmental and CRoHS guidelines
ONT environmental requirements
See the ONT technical specification documentation for more information about
temperature ranges.
Storage
According to ETS 300-019-1-1 - Class 1.1, storage of P-OLT equip ment must be in
Class 1.1, weather-protected, not temperature-controlled storage locations.
Transportation
According to EN 300-019-1-2 - Class 2.3, transportation of the P-OLT equipmen t
must be packed, public transportation with no rain on packing allowed.
Stationary use
According to EN 300-019-1-3 - Class 3.1/3.2/3.E, stationary use of P-OLT
equipment must be in a temperature-controlled location, with no rain on packaging
allowed, and with no condensation allowed.
Thermal limitations
When the P-OLT is installed in the CO or CEV, install air filters on the P-OLT. The
thermal limitations for P-OLT operation in a CO or CEV are:
•operating temperature: 5°C (41°F) to 40°C (104°F)°
•short-term temperature: –5°C (23°F) to 50°C (122°F)
•operating relative humidity: 5% to 85%
•short-term relative humidity: 5% to 95%, but not to exceed 0.024 kg of water/kg
Material content compliance
European Union (EU) Directive 2002/95/EC, “Restriction of the use of certain
Hazardous Substances” (RoHS), restricts the use of lead, mercury, cadmium,
hexavalent chromium, and certain flame retardants in electrical and electronic
equipment. This Directive applies to electrical and electronic products placed on the
EU market after 1 July 2006, with various exemptions, including an exemption for
lead solder in network infrastructure equipment. Alcatel-Lucent products shipped to
the EU after 1 July 2006 comply with the EU RoHS Directive.
End-of-life collection and treatment
Electronic products bearing or referencing the symbol shown in F igure 12 when put
on the market within the European Union (EU), shall be collected and treated at the
end of their useful life, in compliance with applicable EU and local legislation. They
shall not be disposed of as part of unsorted municipal waste. Due to materials that
may be contained in the product, such as heavy metals or batteries, the environment
and human health may be negatively impacted as a result of inappropriate displosal.
xxviiiJuly 2008Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06
ONT Product Information Manual Edition 013FE 51892 AAAA TCZZA
ETSI environmental and CRoHS guidelines
Note — In the European Union, a solid bar under the crossed-out
wheeled bin indicates that the product was put on the market after 13
August 2005.
Figure 12 Recycling/take back/disposal of product symbol
At the end of life, the P-OLT products are subject to the applicable local legislations
that implement the European Directive 2002/96EC on waste electrical and electronic
equipment (WEEE).
There can be different requirements for collection and treatment in different member
states of the European Union.
Moreover, in compliance with legal requirements and contractual agreements, where
applicable, Alcatel-Lucent will offer to provide for the collection and treatment of
Alcatel-Lucent products bearing the logo at the end of their useful life, or products
displaced by Alcatel-Lucent equipment offers. For information regarding take-back
of equipment by Alcatel-Lucent, or for more information regarding the requirements
for recycling/disposal of product, please contact your Alcatel-Lucent account
manager or Alcatel-Lucent takeback support at takeback@alcatel-lucent.com.
Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06July 2008 xxix
3FE 51892 AAAA TCZZAEdition 01 ONT Product Information Manual
ETSI environmental and CRoHS guidelines
xxxJuly 2008Alcatel-Lucent 7342 ISAM FTTU ONT R04.05.06
ONT Product Information Manual Edition 013FE 51892 AAAA TCZZA