AE 6190 User Start and Country Options
1. Country settings via internal jumper setting
FRONT PCB Jumpers No. 1 and 2:
Defines default country setting after DC power connection
1 SHORT : CEPT EC FM 40CH 4W
2 SHORT : GERMANY dE FM 80CH 4W, AM 40CH 1W
1and 2 SHORT : EUROPE EU FM 40CH 4W, AM 40CH 1W
1 and 2 OPEN : SPAIN E FM 40CH 4W, AM 40CH 4W
FRONT PCB Jumper No. 4
Allows user setting by key entries or not
4 SHORT :User selection for country switching via KEY ENTRY not allowed
4 OPEN :User selection for country switching via KEY ENTRY allowed
3. User selection via keys (if enabled by jumper 4)
§ AM/FM KEY LONG PUSH during POWER ON = GERMANY dE (80/40)
§ SC KEY LONG PUSH during POWER ON = EU AREA EU (40/40)
§ SC+CH9 LONG PUSH during POWER ON = CEPT AREA EC (40FM)
§ CH9 LONG PUSH during POWER ON = RESET to start setting rS
Front PCB jumpers / Frontplatine- Lötbrücken
AE 6190 Start – und Ländereinstellungen
1. Ländereinstellungen über interne Lötbrücken
FRONT Platine Brücke Nr. 1 und 2:
Zur Einstellung der ersten Ländereinstellung beim Anschließen an die Stromversorgung
1 VORHANDEN : CEPT EC FM 40CH 4W
2 VORHANDEN : DEUTSCHLAND dE FM 80CH 4W, AM 40CH 1W
1and 2 VORHANDEN : EUROPA EU FM 40CH 4W, AM 40CH 1W
1 and 2 ENTFERNT : SPANIEN E FM 40CH 4W, AM 40CH 4W
FRONT Platine Brücke Nr. 4
Entscheidet, ob Benutzer Ländereinstellungen durch Tasten verändern darf oder nicht
4 VORHANDEN :Ländereinstellung über Tasten nicht möglich
4 ENTFERNT :Ländereinstellung über Tasten erlaubt
3. Länderumschaltung über Tastenkombinationen (sofern
über Brücke 4 freigegeben)
§ AM/FM lang drücken während des Einschaltens = GERMANY dE (80/40)
§ SC lang drücken während des Einschaltens = AM Länder EU (40/40)
§ SC+CH9 lang drücken während des Einschaltens = CEPT Länder EC (40FM)
• CH9 lang drücken während des Einschaltens = RESET rS auf die Startposition