SPECIFICATION
OPERATING VOLTAGE: 12 OR 24 VOLTS AC/DC, AUTO VOLTAGE SELECTION
CURRENT DRAW: 155 MA., (SOUNDER OFF), 200 MA., (SOUNDER MAXIMUM VOLUME)
RELAY CONTACT RATING: 1.3 A. @ 30 VOLTS DC OR 24 VOLTS AC
RELAY CONTACT ARRANGEMENT: DOUBLE POLE-DOUBLE THROW, (2 FORM C)
TEMPERATURE: FOR U.L. LISTED INSTALLATIONS +32 F TO +120 F, (0 C TO +49C)
HUMIDITY: 0% TO 93% NON-CONDENSING FOR ULC-S319 INSTALLATIONS, 0% TO 85%
NON-CONDENSING FOR UL-294 LISTED INSTALL
ATIONS.
REQUEST TO EXIT INPUT: NORMALLY-OPEN DRY CONTACTS
KEYPAD OR CARD READER INPUT: NORMALLY-CLOSED DRY CONTACTS
DOOR POSITION SWITCH INPUT: NORMALLY-OPEN DRY CONTACTS
SIZE: 6.875” L (174.63mm) x 1.875” H (47.63mm) x 2” W (51mm)
MATERIAL: BLACK ANODIZED ALUMINUM AND ABS PLASTIC
WIRING INTERFACE: 14 PIN CONNECTOR WITH 4 FEET OF CABLE
CERTIFICATIONS: UL/CUL 294/S319, FCC PART B
THE SREX-100 HAS A THREE YEAR WARRANTY
PAGE 6PAGE 1
The SREX-100 is an active infrared request to exit sensor for interior applications located
within the protected premise. It is U.L. listed as a request to exit device under the U.L.
UL294 and the CAN/ULC-S319 standard. The SREX-100 is rated a “class 1” as per the CAN/
ULC-S319 standard. The SREX-100 is designed to mount over the door header so that its detection pattern is placed directly over the door handle. When the user reaches for the door
handle the exit device releases allowing the person to exit. The active detection curtain is well
defined to keep the door secure while rejecting parallel traffic and objects placed under it.
TYPICAL INSTALLATION WIRING
B
R
O
W
N
/
W
H
I
T
E
B
R
O
W
N
O
R
A
N
G
E
/
W
H
I
T
E
O
R
A
N
G
E
B
L
U
E
/
W
H
I
T
E
B
L
U
E
W
H
I
T
E
C
O
M
B
G
R
E
E
N
N
/
O
B
Y
E
L
L
O
W
N
/
C
B
W
H
I
T
E
/
B
L
A
C
K
C
O
M
A
Y
E
L
L
O
W
/
B
L
A
C
K
N
/
C
A
G
R
E
E
N
/
B
L
A
C
K
N
/
O
A
B
L
A
C
K
P
W
R
R
E
D
P
W
R
12 OR 24 VDC
I.T.E.
MODEL
AMS4-240100FU
U.L. LISTED
POWER SUPPLY
FILE NUMBER
E141650
+
N/C DOOR
POSITION
SWITCH
MODEL
KP-100
DIP SW. 2
MUST BE
ON WHEN
DOOR
POSITION
SWITCH
IS USED.
USE
COMMON
AND
NORMALLY
OPEN
CONTACTS
USE
COMMON
AND
NORMALLY
CLOSED
MOMENTARY
CONTACTS
TECHNICAL ASSISTANCE
IF TECHNICAL ASSISTANCE IS REQUIRED CALL 1 800 645-5538
MODEL TS-2
U.L. FILE
NUMBER
SA32686
ALARM CONTROLS
U.L. LISTED
MAGNETIC LOCKS
FILE NUMBER
R16759
NOTE:
FOR U.L. LISTED INSTALLATIONS THE SREX-100 SHOULD ONLY BE POWERED BY A U.L. 294
LISTED POWER SUPPLY, AS WELL AS CONNECTED TO A U.L. LISTED ELECTRICAL LOCKING
(EL) DEVICE. FOR CAN/ULC-S319 LISTED INSTALLATIONS THE SREX-100 SHOULD ONLY BE
POWERED BY A ULC--S319 LISTED POWER SUPPLY AS WELL AS CONNECTED TO A ULCS319 LISTED ELECTRICAL LOCKING (EL) DEVICE, CARD READER/KEYPAD AND DOOR/REX
SWITCHES.
THE USE OF ANY ADD-ON, EXPANSION, MEMORY OR OTHER MODULE MANUFACTURED OR
SUPPLIED BY THE MANUFACTURER’S REPRESENTATIVE WILL INVALIDATE THE CAN/ULCS319 CERTIFICATION.
WHEN USED WITH ELECTRIC STRIKES ON SUPERVISED PORTALS, REQUEST-TO-EXIT DEVICES SHALL BY-PASS PORTAL ALERTS CAUSED BY EXITING. WHEN USED WITH ELECTROMAGNETIC LOCKS ON SUPERVISED PORTALS, REQUEST-TO-EXIT DEVICES SHALL SIGNAL
THE ACCESS CONTROL UNIT TO RELEASE THE ELECTROMAGNETIC LOCKS AS WELL AS
TO BYPASS PORTAL ALERTS CAUSED BY EXITING.
TERMINAL AND LEADS COMPLY WITH CSA, C22.1, CANADIAN ELECTRICAL CODE, PART I,
SAFETY STANDARD FOR ELECTRICAL INSTALLATIONS.
FOR U.L. 294 AND NFPA 101 SECTIONS 7.2.6.2.1 WIRE THE LOCKING DEVICE FOR FAIL-SAFE
OPERATION.
CAN/ULC-S319 LIMITS THE RATED OUTPUT OF THE AUDIBLE SIGNAL DEVICE, (STATED AS A
SOUND PRESSURE LEVEL), (SPL), FROM 70 dBA TO A MAXIMUM OF 100 dBA AT 1 METER.
UL-294 LIMITS THE RATED OUTPUT OF THE AUDIBLE SIGNAL TO A MINIMUM OF 85 dBA AT
10 FEET.
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO
THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED THAT MAY
CAUSE UNDESIRED OPERATION.
NOTE: THE THREE INPUTS TO THE SREX-100 MUST BE USED AS A DRY INPUT WITH NO
VOLTAGE APPLIED FROM THE CARD READER, DOOR POSITION SWITCH OR THE
REQUEST TO EXIT STATION.