Akai AC-ZP112 User Manual

English
Table of Contents
1. Accessories ------------------------------------------------------------------------1
2. Introduction--------------------------------------------------------------------------2
3. Working Principle---------------------------------------------------------------- 3
4. Technical Specification----------------------------------------------------------4
6. Operation---------------------------------------------------------------------------6
7. Maintenance----------------------------------------------------------------------15
8. Trouble Shooting----------------------------------------------------------------18
9. Safety Cautions-----------------------------------------------------------------19
10. Special Guide Line--------------------------------------------------------------20
11. After Sale Service---------------------------------------------------------------21
12. Electric Circuit Drawing--------------------------------------------------------22
Notice: Any maintenance should be returned to the dealer or factory!
Attention: Please read this instruction carefully before use.
Accessories
1 inner air exhaust adaptor -------------------------------------------------------1 pc
2 air exhaust duct ---------------------------------------------- --------------------1 pc
3 adaptor ------------------------------------------------------------------------------1 pc
4 mounting duct ---------------------------------------------------------------------1 pc
5 window kit --------------------------------------------------------------------------1 pc
6 cap cover ---------------------------------------------------------------------------1 pc
7 remote controller -----------------------------------------------------------------1 pc
8 instruction manual ---------------------------------------------------------------1 pc
9 water plate ----------------------------------------------------------------------- 1 pc
-1-
Introduction
This mobile air conditioner is a new generation air conditioner which is ideal for using in bedroom, study room, lobby, office, meeting room, warehouse attics, sports hall and other entertainment room. Its flexibility characteristic enables easy adjustments to desirable room temperature and humidity. Besides, the built-in filter can remove floating dust, purify air to create a healthy working environment.
It is designed under ”novelty, practicality and convenience” principles to satisfy the needs for convenient, efficient and mobile small size air conditioner. The part makes the cooling special obvious. It features easy using, no need for installation and convenient maintenance.
The unit is highly competitive to other cooler capable products. With tidy structure, multiple functions and reasonable ventilation design, the unit minimizes noise and power consumption.
Thank you for choosing our mobile air conditioner.
This instruction manual is for reference only and does not constitute a contract.
We reserve the right to technical change without prior notice
-2-
Working Principle
Refrigerant with low temperature and low pressure is compressed by the compressor to high temperature and high pressure vapour, then cools in the condenser (This is a forced air cooling process: room air passes condenser surface, absorbs the refrigerant's heat in the condenser by heat exchange, then the room air warms up and the warm air is exhausted through the air exhaust duct,) to become high pressure liquid. The liquid flows through capillary tube to lower its pressure to become low temperature low pressure liquid. After absorbing the heat of air in the surface of evaporator (A forced air cooling process too: room air passes evaporator surface, its heat is absorbed by refrigerant in tube, it cools down and flows into room to lower the room temperature). The low temperature low pressure liquid is evaporated in the evaporator. The refrigerant becomes vapour and flows back to compressor. Then the refrigerant vapour is compressed in compressor again. Thus the room temperature is lowered by circulating this operation.
compressor
fan motor
cool air (heating)
upper fan
lower fan motor
condenser
evaporator
air flow1
capillary tube
hot air
lower fan
air flow2(air inflow from back)
-3-
Unit specifications
Cooling Capacity ( Btu / h ) 12000
Dehumidifying Capacity ( L / day ) 24
Power consumption( W ) 1200
Flow Volume (m3 / h )
Sound pressure level dB(A) ≤55
Net Weight ( Kg ) 33
Technical Specification
Model AC-ZP112
480
Dimension
Body ( mm ) 738*446*377
Package ( mm ) 860*460*450
Refrigerant R407C
Note:
1. The above cooling capacity measured at ambient temperature Db 27°C/19°C Wb 27°C/19°C. (indoor and outdoor , the same)
Db means Dry Bulb ( that is testing in dry environment) Wb means Wet Bulb ( that is testing in wet environment)
2. Noise level is measured at the point where 1.0 meter away from the front of the machine. In cooling mode.
3. Air exhaust duct tore down, pump work, fan power consumption is measured when fan runs at highest speed.
4. Specification listed above is for reference only. Please see actual data printed on the label.
-4-
Structure
1. Control panel 2. Air outlet 3. Handle 4. Caster 5. Air filter
6. Air inlet 7. Exhaust air outlet 8. Cord Hanger 9. Water stopper
5
6
7
8
9
10. Inner air exhaust adaptor-connect with air exhaust duct (11) and exhaust air
outlet (7) 11. Air exhaust duct 12. Adaptor 13. Mounting Duct 14. Window kit 15. Water plate 16. Remote controller
10
15
11
14
12
ON/OFF
16
13
-5-
Operation
1. Control panel
2 5 3
AC-ZP112
1
7
2On/Off switch button
Press On/Off button once the power is on, the unit will run at auto mode.
6
Press On/Off button while the unit is running, the unit stops, and timer setting is canceled, other information (mode, set temp, and fan speed) remain in the machine.
3. Mode button Press Mode button, unit run mode will change at sequence of AUTO, COOL,
DEHUMIDIFY and To should of the LED light is bright.
4. FAN SPEED button Press SPEED button, unit run mode will change in sequence of: HIGH, MID, LOW
and to should of the LED light is bright.
5. TEMP UP, DOWN button Press TEMP button to adjust desired room temperature and it will display
in LED window correspondingly, the temperature adjustment range is 15°C--31°C
60-90°F. When unit is setting at AUTO running mode, the default cooling
temperature is 23°C68°F. Press the TEMP UP、DOWN button at the same time,the temperature display will be shown between °C and °F.
6. TIMER button TIMER OFF:
When unit under running mode, press timer button to set desire OFF time,
time set from 0.5 hour to 12 hours, the timer setting will display in LED window correspondingly TIMER ON:
When unit is ready, press TIMER button to set desire ON time, time set
from 0.5 hour to 12 hours, the timer setting will display in LED window correspondingly
7. SWING button When unit under running mode, press swing button to auto adjust a right and left direction of wind.
-6-
4
Loading...