A.J. Antunes & Co VZN-440H 9700746 User Manual

0 (0)

MANUFACTURING

NUMBERS:

9700726

9700746

System Tested and Certified by NSF International and WQA against NSF/ANSI Standard 42 and 53 for the reduction of:

Standard No. 42: Aesthetic Effects Nominal Particulate Reduction Class I Standard No. 53: Health Effects

Cyst Reduction & Turbidity Reduction as verified and substantiated by test data.

System Tested and Certified by WQA against NSF/ANSI Standard 372 for lead-free compliance

P/N 1011064 Rev. F 12/13

VZN WATER

FILTRATION

VZN-420H, VZN-440H

Owners Manual

VZN SERIES

TABLE OF CONTENTS

Owner Information................................................................

2

Mounting the System........................................................

10

General...............................................................................

2

Alternative Vertical Mounting............................................

10

Warranty Information..........................................................

2

Drain Valve Connection.....................................................

11

Service/Technical Assistance..............................................

3

System Inlet Connection...................................................

12

Important Safety Information...............................................

4

Filtered Water Permeate Outlet Connection.....................

12

Specifications........................................................................

6

Inlet Water Plumbing........................................................

12

Dimensions.........................................................................

6

Installing a Bypass............................................................

13

Electrical Ratings and Plug Configurations........................

6

Starting the Controller.......................................................

13

Replacement Cartridges.....................................................

6

Rinsing the Ultra Filter Cartridge......................................

13

Electrical Cord & Plug Configurations................................

6

Sanitizing the System and Lines......................................

14

Performance Data Sheet......................................................

7

Maintenance........................................................................

15

Filter Cartridge Capacities..................................................

7

Replacing the Ultra Filter Cartridge..................................

15

Performance Claims for Percent Reduction.......................

7

System Sanitization..........................................................

15

Operation...............................................................................

8

Changing the Interval Setting...........................................

16

Overview.............................................................................

8

Resetting the Timer Program............................................

16

Manual Flushing.................................................................

8

Check Permeate Tank Air Pre-Charge.............................

16

Installation.............................................................................

9

Troubleshooting..................................................................

17

Unpacking...........................................................................

9

Replacement Parts..............................................................

18

Equipment Setup................................................................

9

Limited Warranty.................................................................

20

OWNER INFORMATION

General

The VZN system is an innovative filtration system that uses proprietary multi-bore hollow fiber membranes as well as a carbon element to provide the latest innovation in filtration technology.

This manual provides the safety, installation, and

operating procedures for the VZN water filtration system. All information contained in this manual should be read prior to installing and operating the system. Your VZN system is manufactured from the finest materials available and is assembled to strict quality standards. This system has been tested at the factory to ensure dependable trouble-free operation.

Warranty Information

Please read the full text of the Limited Warranty in this manual.

If the system arrives damaged, contact the carrier immediately and file a damage claim with them. Save all packing materials when filing a claim. Freight damage claims are the responsibility of the purchaser and are not covered under warranty.

The warranty does NOT extend to:

Damages caused in shipment or damage as result of improper use.

Installation of electrical service.

Normal maintenance as outlined in this manual.

Malfunction resulting from improper maintenance.

Damage from moisture leaking into electrical components.

Damage from tampering with, removal of, or changing any preset control or safety device.

IMPORTANT! Keep these instructions for future reference. If the system changes ownership, be sure this manual accompanies the equipment.

2

P/N 1011064 Rev. F 12/13

VZN SERIES

OWNER INFORMATION (continued)

Service/Technical Assistance

If you experience any problems with the installation or operation of your system, contact A.J. Antunes & Co. at 1-630-784- 1000, or toll free in the United States at 1-800-253-2991.

Fill in the information in the next column and have it handy when calling for assistance. The serial number is on the specification plate located on the system.

Purchased From:

Date of Purchase:

Model No.:

Serial No.:

Mfg. No.:

Suggested replacement period for the Ultra Filter Cartridge is approximately 3 years.

For sales in the state of Iowa:

 

Seller:

 

Date:

Buyer:

 

Date:

IMPORTANT

A.J. Antunes and Company reserves the right to change specifications and product design without notice. Such revisions do NOT entitle the buyer to corresponding changes, improvements, additions, or replacements for previously purchased equipment.

P/N 1011064 Rev. F 12/13

3

VZN SERIES

IMPORTANT SAFETY INFORMATION

In addition to the warnings and cautions in this manual, use the following guidelines to safely operate the system:

Read all instructions before using equipment.

Install or locate the equipment only for its intended use as described in this manual.

Do NOT use corrosive chemicals in this equipment.

Do NOT operate this equipment if it has a damaged cord or plug; if it is not working properly, or if it has been damaged or dropped.

This equipment should be serviced by qualified personnel only. Contact A.J. Antunes & Co. for repair.

Do NOT immerse cord or plug in water.

Keep cord away from heated surfaces.

This equipment should be supplied with only cold water.

For installations in Massachusetts, the Commonwealth of Massachusetts Plumbing Code 248 CMR shall be adhered to. The use of saddle valves are not permitted. Please consult your local plumber.

The following warnings and cautions appear throughout this manual and should be carefully observed.

Unplug the power cord before performing any service or maintenance on the unit.

All electrical connections must be in accordance with local electrical codes and any other applicable codes.

WARNING ELECTRICAL SHOCK HAZARD. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN SERIOUS INJURY OR DEATH.

-Do NOT modify the power supply cord plug. If it does not fit the outlet, have a proper outlet installed by a qualified electrician.

-Do NOT use an extension cord with this unit.

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or a similarly qualified person.

This equipment is to be installed to comply with the local plumbing code and any other applicable code.

Water pressure must not exceed 100 psig (690 kPa). To reduce water pressure, install a water pressure regulator and set to suit the application.

The trans membrane pressure (inlet pressure minus the permeate water pressure) must not exceed 45 psi (310 kPa).

A ground fault circuit interrupter (GFCI) must be installed on the circuit to this system.

When installed on metallic plumbing, a properly sized electrical bonding jumper must be installed across the inlet and outlet pipes serving this unit.

NOTE: If the inlet water pressure is less than 50 psig (345 kPa), it is recommended that a suitably-sized booster system (outlet pressure 60 psig - 100 psig max (414 kPa - 690 kPa max) be installed.

4

P/N 1011064 Rev. F 12/13

VZN SERIES

IMPORTANT SAFETY INFORMATION (continued)

Protect from becoming dry

If the membrane dries out, irreversible damage to the Ultra Filter membrane may result. Protect the filter from becoming dry by keeping it wet and sealed at all times.

Protect from freezing

If the Ultra Filter membrane freezes during operation or storage, irreversible damage to the membrane and brittle cracking of the cartridge or housing may result.

Protect from direct sunlight or other UV sources

Avoid long-term exposure to direct sunlight or other UV sources. The Ultra Filter should be stored in a dark location.

Protect from high temperatures or abrupt variation in temperature

The maximum operating temperature is 100°F (38°C). Avoid abrupt variations in temperature. Any temperature variation should be made slowly.

Protect from rough handling or dropping

Mechanical damage, external breakage, and/or internal breakage of the filter can result if the system is dropped or bumped. Handle with care at all times during transportation and installation.

Protect from organic solvents and concentrated acids

Prevent any and all contact of the membrane with strong solvents, solvents containing chlorine, or concentrated acids. Do NOT use strong solvents or concentrated acids on any plastic parts of the filter system. Examples of some solvents to avoid: acetone, methyl acetate (nail polish remover); hexane (spot removers); turpentine, toluene (paint thinners); dry cleaning solutions, insecticides.

Protect from abrasive material

The membranes must be protected from abrasive materials like shavings left in a pipe. Abrasive materials in contact with the membrane can cause irreversible damage to the membrane. All pipes must be flushed clean before installing the filter. All plastic parts of the filter system must be protected from sharp objects like knives, sand paper, or other tools. Cutting or nicking a plastic part can weaken it and cause a leak. Do NOT use abrasive cleansers on any plastic parts.

Protect from water hammer

The system must be protected from shock, pressure surges, or pulsation that may occur inside water pipes. Water hammer occurs in pipes when a valve or faucet shuts quickly. Install a water hammer arrestor (pressure vessel containing compressed air separated from the water by a diaphragm) to reduce pressure shock.

CAUTION

This equipment is to be installed to comply with the basic plumbing code of the Building Officials and Code Administrators, Inc. (BOCA) and the Food Service Sanitation Manual of the Food and Drug Administration (FDA).

CAUTION

Water Flow Regulator Assemblies are NOT interchangeable. Operating the system with the wrong Water Flow Regulator or without a regulator can damage the system, cause personal injury, and voids the warranty!

CAUTION

All electrical connections must be in accordance with local electrical codes and any other applicable codes.

A ground fault circuit interrupter (GFCI) must be installed on the circuit to this system.

When installed on metallic plumbing, a properly sized electrical bonding jumper must be installed across the inlet and outlet pipes serving this unit.

P/N 1011064 Rev. F 12/13

5

A.J. Antunes & Co VZN-440H 9700746 User Manual

VZN SERIES

SPECIFICATIONS

Dimensions

 

 

 

 

VZN-420H

 

VZN-440H

 

A

 

 

A

 

C

B

C

 

 

 

 

B

 

 

 

 

Model &

Width

Depth

Height

Operating

Mfg. No.

(A)

(B)

(C)

Weight

VZN-420H

31"

9"

15"

40 lbs.

9700726

(79 cm)

(23 cm)

(38 cm)

(18 kg)

VZN-440H

50"

9"

15"

54 lbs.

9700746

(127 cm)

(23 cm)

(38 cm)

(25 kg)

CAUTION

All electrical connections must be in accordance with local electrical codes and any other applicable codes.

A ground fault circuit interrupter (GFCI) must be installed on the circuit to this system.

When installed on metallic plumbing, a properly sized electrical bonding jumper must be installed across the inlet and outlet pipes serving this unit.

Electrical Ratings and Plug Configurations

Model &

Volts

Watts

Amps

Hertz

Mfg. No.

 

 

 

 

VZN-420H

100–240

10

.08

50/60

9700726

 

 

 

 

 

 

 

 

 

VZN-440H

100–240

10

.08

50/60

9700746

 

 

 

 

 

 

 

 

 

NOTE: Includes plug adaptors for US, Europe, Australia, and UK.

Replacement Cartridges

Replacement

 

Part Number

 

 

 

VZN-420H

L-420 Ultra Filter

7000411

 

 

 

VZN-440H

L-440 Ultra Filter

7000412

 

 

 

Electrical Cord & Plug Configurations

Kit Model

Description

Configuration

Number

 

 

 

DC Power Supply

 

 

100 - 240 VAC

 

0012146

Includes the

 

 

4 plug adaptors

 

 

below

NOTE: PLUG STYLE

 

MAY VARY

 

US

 

 

NEMA 1-15 (2 pin)

 

 

or NEMA 5-15

 

 

(3 Pin)

 

 

Euro

 

 

CEE 7/16

 

 

AS/NZS

 

 

3112

 

 

AUS

 

 

(2 Pin)

 

 

UK

 

 

BS 1363

 

6

P/N 1011064 Rev. F 12/13

Loading...