HDD High wall
Indoor Units
AWSI-HDD009N11
AWSI-HDD012N11
AWSI-HDD018N11
AWSI-HDD024N11
Outdoor Units
AWAU-YDD009H11
AWAU-YDD012H11
AWAU-YDD018H11
AWAU-YDD024H11
Cooling
Capacity kW 2.65 (0.45-3.23) 3.53 (0.6-3.96) 5.3 (1.05-6.5) 6.45 (1.4-7.0)
Input power kW 0.8 1.1 1.6 2
EER/Energy Label 3.3/A 3.21/A 3.31/A 3.22/A
Operating limits °C 10°/48° Dry bulb 5°/46° Dry bulb
Heating
Capacity kW 3.52 (0.45-4.1) 4.1 (0.6-5.13) 5.8 (1.0-7.1) 6.7 (1.2-8.0)
Power input kW 0.95 1.14 1.6 1.85
COP/Energy Label 3.7/A 3.61/A 3.62/A 3.62/A
Operating limits °C -15°/24° Dry bulb -15°/30° Dry bulb
indoor
unit
Sound pressure level to 1 m (LS/MS/HS/SS)
dB(A) 24/30/36/41 25/31/37/42 29/37/40/45 34/39/44/48
Sound power level (LS/MS/HS/SS) dB(A) 34/40/46/51 35/41/47/52 39/47/50/55 44/49/54/58
Airow (LS/MS/HS/SS) m
3
/h 280/370/520/630 300/410/560/680 460/560/680/800 550/700/800/1000
Dehumidication l/h 0.8 1.5 3 4
Dimensions (WxDxH) mm 770x201x283 770x201x283 865x215x305 1008x221x319
Weight kg 8 9 12 15
Part number 7SP022852 7SP022853 7SP022854 7SP022855
outdoor
unit
Sound pressure level to 1 m dB(A) 47 48 54 56
Sound power level dB(A) 57 58 64 66
Airow m
3
/h 1600 1600 2700 2900
Compressor type Rotary DC Inverter Rotary DC Inverter Twin Rotary DCI Twin Rotary DCI
Dimensions (WxDxH) mm 658x275x550 658x275x550 955x396x700 955x396x700
Weight kg 28 30 52 55
Part number 7SP061774 7SP061775 7SP061776 7SP061777
Power
suPPly
1~230V - 50 Hz
Power supply side Indoor Indoor Indoor Indoor
Power cable section mm
2
3x1.5 3x1.5 3x2.5 3x2.5
Fuse rating am A 16A 16A 25A 25A
Electrical connections mm
2
4x1.5 4x1.5 4x2.5 4x2.5
PiPe line
Suction pipe diameter inches 3/8’’ 3/8’’ 1/2’’ 1/2’’
Liquid pipe diameter inches 1/4’’ 1/4’’ 1/4’’ 1/4”
Max length m 15 15 25 25
Max height m 5 5 10 10
features
A/A class. Minumum energy
consumption.
Automatic self clean and internal
system drying.
Self diagnostic by digital failure code
indication.
proDuct functions
High wall line available in capacities 2.65 up to 6.45 kW.
DC Inverter and sine wave compressor drive technology.
Photo catalytic antibacterial prefilter.
-15°C operating in heating mode.
Cooling & heating operation mode.
“I feel” function with precise room temperature control.
CLASS
A/A CLASS NANO
AUTO
AUTO CLEAN/DRY DIGITAL DISPLAY
TIMER AUTO MODE
-
-15°C MINIMUM
HEATING
DC INVERTER ELECTROSTATIC
I FEEL TURBO MODE
SELF DIAGNOSTIC-
DIGITAL
°C
SUPER PLASMA
SINE WAVE
COMPRESSOR DRIVE
WIDE ANGLE LOUVER
LOW BATTERY
INDICATION
GOLDEN FINS
CONDENSER
Low
LOW VOLTAGE
STARTUP
MOTORIZED 2D
AIRFLOW
RESTART
AUTO RESTART
Low
LOW TEMPERATURE
STARTUP
SLEEP MODE
REMOTE CONTROL
LOCK
R410A
R410A FLUID
HOT KEEP
ADVANCED DEFROST
PHOTOCATALYTIC
FILTER
AUTO
OPERATION
ON REQUEST
FILTER -
ANTIBACTERIA
TURBO
TEST
MODE
TECHNICIAN TEST
MODE
CM HDD GB 0312 - Specications subject to change without notice. Pictures non contractual. Printed in UE.
Airw ell Fran ce S AS
1 bis avenue du 8 mai 1945
78280 Guyancourt
France
Tel. +33 (0)1 39 44 78 00
Fax +33 (0)1 39 44 00 14
contact@airwell-group.com
www.airwell.com