Rev. E 7/05
MODELO 4TM65A/9530A
NOTAS
8
2084532
OPERATING INSTRUCTIONS & PARTS MANUAL
9" HIGH PERFORMANCE PIVOT FAN
9" (22.8 cm) MODEL 4TM65A/9530A
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT
DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO
COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
DESCRIPTION
The Airking 9" (22.9 cm) high performance pivot fan features
3-speed rotary knob operation with 112° adjustable tilt stand. The
9" ( 22.9 cm) 3-paddle blade is driven by a permanent prelubricated
motor with a 6' (1.83 m) 18/3 cordset
SPECIFICATIONS
Motor..............................120V, 60 Hz
Blade Diameter ..............9" ( 22.9 cm)
Speeds...........................3
Control ...........................Rotary Knob
Air Flow Distribution.......112° Variable
Approvals.......................UL listed. Close mesh fan guard meets
OSHA requirements.
MODEL
SPEED
CFM 700 610 520
M3/s 0.33 0.29 0.25
RPM 2100 1800 1500
Amps 0.50 0.43 0.37
Watts 58 51 45
dB A 54 50 46
4TM65A/9530A
HIGH MED LOW
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions should always be followed to reduce the
risk of fire, electric shock and injury to person,
including the following:
1. Read all instructions before using Fan.
2. Make certain that the power source conforms to the electrical
requirements of the Fan.
3. Use this Fan only as described in this manual. Any other use not
recommended by the manufacturer may cause fire, electrical
shock, or injury to persons.
5. Unplug power cord before installing, servicing, or moving the Fan.
WARNING: DO NOT DEPEND UPON THE ON-OFF
SWITCH AS THE SOLE MEANS OF DISCONNECTING
POWER WHEN INSTALLING OR SERVICING THE FAN.
ALWAYS UNPLUG THE POWER CORD.
6. This Fan must NOT be used in potentially dangerous
locations such as flammable, explosive, chemical-laden
or wet atmospheres.
7. DO NOT use Fan in or near a window. Rain may create an
electrical hazard.
2. The power cord is equipped with a three-prong grounded plug
that must be inserted into a matching receptacle. Under no
circumstances must the grounding prong be cut off the plug.
Where a two-prong wall receptacle is encountered, it must be
Rev. E 7/05
replaced with a properly grounded three-prong receptacle installed in accordance with the National Electrical Code (NEC)
and all applicable local codes and ordinances. This work must
be done only by a qualified electrician, using copper wire only.
WARNING: USE OF A THREE-PRONG TO TWO-PRONG
ADAPTER IS NOT RECOMMENDED. IMPROPER CONNECTION MAY CREATE THE RISK OF ELECTROCUTION.
USE OF SUCH ADAPTERS IS NOT PERMITTED IN CANADA.
WARNING: THIS PLUG IS A SAFETY FEATURE. TO
REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND
PERSONAL INJURY, DO NOT REMOVE, REPLACE,
REPAIR OR TAMPER WITH THE ORIGINALLY SUPPLIED
PLUG. IF THE FAN DOES NOT FUNCTION PROPERLY, IT
MAY BE DUE TO THE SAFETY DEVICE INCORPORATED
IN THIS PLUG. RETURN TO AN AUTHORIZED SERVICE
CENTER OR CALL 800-233-0268, MONDAY - FRIDAY,
BETWEEN 8:00 AM AND 5:00 PM EST. IF THE PLUG
WARNING LABEL IS MISSING OR DAMAGED, CALL THE
TOLL FREE NUMBER FOR A REPLACEMENT LABEL.
8. Where possible, avoid the use of e xtension cords. If the y must be
used, minimize the risk of overheating by ensuring that they are
UL listed. Ne ver use a single extension cord to operate more than
one Fan.
9. Do not operate any Fan with a damaged cord or plug or after the
Fan malfunctions, has been dropped or damaged in an y manner .
Return Fan to authorized service facility for e xamination, electrical
or mechanical adjustment or repair.
10.Do not insert or allow fingers or foreign objects to enter any
ventilation or exhaust opening as it may cause an electric shoc k
or fire, or damage the Fan. Do not block or tamper with the F an
in any manner while it is in operation.
11.Always place the Fan on a stable, flat, level surface when
operating, to avoid the chance of the Fan overturning. Locate the
Power Cord so the Fan or other objects are not resting on it. Do
not run Power Cord under carpeting. Do not cover Power Cord
with throw rugs, runners, or the like. Arrange Power Cord away
from room traffic and where it will not be tripped over.
12.This Fan is not intended for use in wet or damp locations.
Never locate a Fan where it may fall into a bathtub or other
water container.
13. Do not use Fan outdoors.
WARNING: REDUCE THE RISK OF FIRE OR ELECTRIC
SHOCK – DO NOT USE THIS F AN WITH ANY SOLID ST ATE
SPEED CONTROL DEVICES.
SAVE THESE
INSTRUCTIONS
1
2084532
MODEL 4TM65A/9530A
MODELO 4TM65A/9530A
OPERATION
1. Plug the Fan into any standard 120V AC household outlet.
2. Using the Rotary Switch, set the desired fan speed.
3. To rotate Fan, loosen Knobs on side of Grill and tilt to direct air flow.
MAINTENANCE
WARNING: ALWAYS UNPLUG THE CORD BEFORE SERVICING.
CLEANING: Use a soft cloth and a mild soap solution such as liquid dish washing detergent.
CAUTION: Do not use gasoline, benzine, thinner, harsh cleaners, etc. as they will damage the Fan. NEVER use ALCOHOL OR
SOLVENTS.
Dry all parts with a soft cloth completely before reconnecting to power supply.
STORAGE: When not in use, keep unit in a clean dry place.
MOTOR IS PERMANENTLY LUBRICATED.
OPTIONAL: WALL-MOUNTING CONFIGURATION
Two #8 x 1-1/4" Wood or equivalent Screws must be purchased
separately for Wall-Mount configuration.
1. Remove Wall-Mount Template from this Instruction Sheet.
2. Place the Wall-Mount Template against the wall at desired height
and mark the center of the two vertical holes. Make sure the chosen
location is centered on a stud (unless wall anchors are being used).
3. Install a Screw (#8 x 1-1/4" Wood Screw or equivalent (2x)), NOT
SUPPLIED - must be purchased separately), in each marked
location.
4. Tighten Screws down leaving a 1/8" to 3/16" gap between the wall and the bottom of the Screw Head.
IMPORTANT!!! MAKE SURE SCREWS ARE ENGAGING THE STUD.
5. Mount the Fan by aligning the two Holes on the Wall-Mount Bracket to the two Screws on the wall. Once the Fan is on, gently pull
down making sure the Fan is securely fastened.
* For proper brick wall installation use masonry anchors, not included, and follow instructions.
This mounting procedure allows for the fan to be hung horizontally or vertically, a total of four positions, without relocating the screws.
(Figure 1)
Mark Center
Figure 1
2
1/8" - 3/16"
Stud
Figure 2
(Figure 2)
1
GARANTÍA LIMITADA
GARANTÍA LIMITADA DE TRES AÑOS DE AIRKING. AirKing garantiza el producto al usuarlo original, contra defectos de
mano de obra o materiales en condiciones de uso normales. El motor está garantizado por tres años y todas las demás partes
por un año, a partir de Ia fecha de compra. Toda pieza qua AirKing determine que está defectuosa en material o mano de obra
y sea enviada a un centro de serviclo autorizado, designado por AirKing, con los costos de envío prepagados, será, como
remedio exclusivo, reparada o reemplazada a opción de AirKing. Para procedimientos de reclamación de garantía, véase el
párrafo de RÁPIDA DISPOSICIÓN a continuación. Esta garantía limitada otorga a los compradores derechos legales
específicos que varían de estado a estado.
LIMITACIÓN DE RESPONSABILI DAD. En Ia medida que lo permitan las leyes aplicables, AirKing renuncia expresamente
a toda responsabilidad por daños y perjuicios indirectos. La responsabilidad de AirKing en todo caso estará limitada al precio
de compra y no habrá de exceder de éste.
DENEGACIÓN DE GARANTÍA. AirKing ha realizado un esmerado esfuerzo por ilustrar y describir de manera precisa los prod
uctos que aparecen en el presente material impreso; sin embargo, dichas ilustraciones y descripciones son para el solo propósito
de identificación y no expresan o implican una garantía de que los productos son comerciables, o que son aptos para cierto
propósito en particular, o que los productos necesariamente se conformarán a las ilustraciones o descripciones.
Con excepción de lo dispuesto a continuación, AirKing no hace ni autoriza ninguna garantía o declaración de un hecho, ni
expresa ni implícitamente, aparte de lo declarado en el párrafo “GARANTÍA LIMITADA” anterior.
IDONEIDAD DEL PRODUCTO. Muchos estados y localidades tienen códigos y reglamentos que rigen la venta, construcción,
instalación y/o el uso de productos para ciertos propósitos, los cuales pueden variar de los de áreas vecinas. Si bien AirKing trata de
asegurarse de que sus productos cumplan con dichos códigos, AirKing no puede garantizar el cumplimiento de los mismos ni puede
ser responsable de la manera en que se instale o se use el producto. Antes de comprar y utilizar un producto, sírvase examinar la
aplicación del mismo y los códigos y reglamentos nacionales y locales, y cerciorarse de que el producto, la instalación y el uso cumplan
con ellos.
Ciertos aspectos de las denegaciones de responsabilidad no son aplicables a productos de consumo; por ejemplo, (a) algunos
estados no permiten la exclusión o limitación de daños y perjuicios indirectos, por lo que la limitación o exclusión anterior podría
no ser aplicable a usted; (b) además, ciertos estados no permiten limitaciones a la duración de una garantía implícita y por
consiguiente la limitación anterior podría no ser aplicable a usted; y (c) por ley, durante el periodo de la Garantía Limitada, y
garantías implícitas de comerciabilidad o idoneidad para cierto propósito en particular aplicable a los productos de consumo
adquiridos por el público consumidor, no podráan ser excluidas o denegadas de ninguna otra forma.
RÁPIDA DISPOSICIÓN. AirKing realizará un esfuerzo de buena fe por rápidamente corregir o hacer algún otro ajuste a cualquier
producto que se demuestre que está defectuoso dentro de la garantía limitada. Pars todo producto que se crea que está
defectuoso dentro de la garantía limitada, escriba o llame primero al comarciante al que haya comprado el producto. Él Ie dará
instrucciones adicionales.
Rev. E 7/05
4
5
3
REPLACEMENT PARTS LIST
8
10
11
13
6
7
9
8
11
12
2
2
Key Part No. Description Qty.
1 2011056 Switch Knob 1
2 2090008 Screw #8 x 1/2 Type 25 PPH 6
3 02030007AK Motor Assembly w/Cover and Cordset 1
4 2011051 Rear Grill 1
5 2011053 Blade 1
6 2091008 Lockwasher #12 External Tooth 1
7 2091160 Hex Nut 12-24 1
8 2011055 Ratchet Plate 2
9 2090017 Screws #8 x 1/2 Hex Sems 2
10 2011052 Base 1
11 2010415 Foot 4
12 2011054 Mounting Bracket 1
13 2011050P Front Grill 1
2084532
PLANTILLA
INFERIOR
NO SUMINISTRADOS - Dos (2) tornillos para madera no. 8 x 1-1/4” (Comprarlos por separado)
Rev. E 7/05
✁
4-1/8" (10.48 cm)
7
SUPERIOR
2084532