Air King 4DA36B-9106B, 4DA35B-9102B User Manual

OPERATING INSTRUCTIONS & PARTS MANUAL
OSCILLATING FANS
12" (30,5 cm) MODEL 4DA35B/9102B 16" (40,6 cm) MODEL 4DA36B/9106B
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DE-
SCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY
WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
DESCRIPTION
The Air King ® 12" (30,5 cm) and 16" (40,6 cm) Oscillating Fans feature whisper quiet operation with a 3 paddle blade. Fan is powered by a pre-lubricated permanent split capacitor motor with a 6 ft. (1.8 m) 18/3 cord set. Fan grills meet OSHA requirements. ETL listed.
SPECIFICATIONS
Motor ........................................120V, 60Hz (12")(30,5 cm)
120V, 60Hz (16")(40,6 cm)
Blade Size ................................12" (30,5 cm) Model(4DA35B/9102B)
16" (40,6 cm) Model(4DA36B/9106B)
Speeds .....................................3 Speeds
Control .....................................Rotary Knob
Air Flow Distribution ................90°
MODEL 4DA35B/9102B 4DA36B/9106B SPEED HIGH MED LOW HIGH MED LOW
CFM 930 780 620 1710 1500 1330 M3/s 0.43 0.37 0.29 0.80 0.71 0.63 RPM 1450 1300 1090 1545 1394 1244 Amps 0.40 0.30 0.27 0.71 0.54 0.48 Watts 39 35 32 77 65 57 dB (A) 45 41 36 53 49 44
GENERAL SAFETY INFORMATION
When using electrical appliances, basic pre­cautions should always be followed to reduce the risk of fire, electric shock and injury to person, including the following:
1. Read all instructions before using Fan.
2. Make certain that the power source conforms to the electrical requirements of the Fan.
3. Use this Fan only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electrical shock, or injury to persons.
4. Unplug power cord before installing, servicing, or moving the Fan.
WARNING: DO NOT DEPEND UPON THE ON-OFF
SWITCH AS THE SOLE MEANS OF DISCONNECTING POWER WHEN INSTALLING OR SERVICING THE FAN. ALWAYS UNPLUG THE POWER CORD.
5. This Fan must NOT be used in potentially dangerous locations such as flammable, explosive, chemical-laden or wet atmospheres.
6. DO NOT use Fan in or near a window. Rain may create an electrical hazard.
7. The power cord is equipped with a three-prong grounded plug
that must be inserted into a matching receptacle. Under no circumstances should the grounding prong be cut off the plug. Where a two-prong wall receptacle is encountered, it must be replaced with a properly grounded three-prong receptacle installed in accordance with the National Electrical Code (NEC) and all applicable local codes and ordinances. This work must be done only by a qualified electrician, using
copper wire only.
Rev. F 10/09
WARNING: USE OF A THREE-PRONG TO TWO-PRONG
ADAPTER IS NOT RECOMMENDED. IMPROPER CONNEC­TION MAY CREATE THE RISK OF ELECTROCUTION. USE OF SUCH ADAPTERS IS NOT PERMITTED IN CANADA.
WARNING: THIS PLUG IS A SAFETY FEATURE. TO
REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND PERSONAL INJURY, DO NOT REMOVE, REPLACE, REPAIR OR TAMPER WITH THE ORIGINALLY SUPPLIED PLUG. IF THE FAN DOES NOT FUNCTION PROPERLY, IT MAY BE DUE TO THE SAFETY DEVICE INCORPORATED IN THIS PLUG.
8. Where possible, avoid the use of extension cords. If they must be used, minimize the risk of overheating by ensuring that they are UL listed. Never use a single extension cord to operate more than one Fan.
9. DO NOT operate any Fan with a damaged cord or plug or after the Fan malfunctions, has been dropped or damaged in any manner.
10.DO NOT insert or allow fingers or foreign objects to enter any ventilation or exhaust opening as it may cause an electric shock or fire, or damage the Fan. DO NOT block or tamper with the Fan in any manner while it is in operation.
11.Always place the Fan on a stable, flat, level surface when operating, to avoid the chance of the Fan overturning. Locate the Power Cord so the Fan or other objects are not resting on it. DO NOT run Power Cord under carpeting. DO NOT cover Power Cord with throw rugs, runners, or the like. Arrange Power Cord away from room traffic and where it will not be tripped over.
12.This Fan is NOT intended for use in wet or damp locations. Never locate a Fan where it may fall into a bathtub or other water container.
13.DO NOT use Fan outdoors.
14.This Fan is NOT suitable for use in agricultural facilities including areas where livestock, poultry or other animals are confined. Please refer to National Electric Code (NEC) Article 547-7 (2008), or applicable state or local codes or standards relating to electrical requirements for Agricultural Buildings. THIS FAN
DOES NOT MEET THE REQUIREMENTS OF NEC ARTICLE 547-7 (2008).
15.This Fan is NOT suitable for use in hazardous locations. Please refer to National Electric Code (NEC) Article 500 or applicable state or local codes or standards relating to electrical requirements for Hazardous locations. THIS FAN DOES NOT MEET THE
REQUIREMENTS OF NEC ARTICLE 500 (2008).
WARNING: REDUCE THE RISK OF FIRE OR ELECTRIC
SHOCK – DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICES.
SAVE THESE
INSTRUCTIONS
1
2084067
4DA35B/9102B and 4DA36B/9106B
ASSEMBLY
1. Tilt Fan Head back. Put Plastic Rear Grill on Motor. (Figure 1)
2. Align Triangular "" cut in Plastic Rear Grill with triangular post on top of front Motor cover. Fully seat Plastic Rear Grill and secure with Plastic Nut turning Clockwise. (Figure 2)
3. Slide Blade onto Motor Shaft. (Align groove on blade hub with pin on motor shaft.) (Figure 3)
4. To secure Blade, screw Spinner onto Shaft Counter Clockwise until tight on blade hub.
5. With fan head in upright position, align Ornament of Front Grill so it is horizontal. Insert bottom of Front Grill into Plastic Rear Grill. Tab at the bottom of Plastic Rear Grill should fit between spokes of Front Grill. Snap Front Grill into Plastic Rear Grill beginning at the top and working down both sides.
Plastic
Rear Grill
Figure 1
Blade
Plastic Nut
Spinner
Front
Grill
Plastic Rear
Grill
Figure 2
Groove
Motor
Figure 3
Pin
Pin
OPERATION
VARIABLE OSCILLATION: Pull oscillation knob on the rear of the motor up. Turn fan head to left, right, or straight ahead. Push oscil­lation knob down and fan will oscillate about the set angle. VERTICAL ANGLE: To adjust vertical angle, tilt fan head up or down, as desired. SPEED: Speed is controlled by a rotary knob. (0) Off, (3) High, (2) Medium, (1) Low. POWER SUPPLY CORD: Plug power supply cord into a wall outlet (AC 120Volts, 60 Hz).
MAINTENANCE
WARNING: ALWAYS UNPLUG THE CORD BEFORE MOVING
OR SERVICING THE FAN.
WARNING: DO NOT IMMERSE FAN IN WATER!
CLEANING: Use a soft cloth moistened with a mild soap solu-
tion, such as liquid dish washing detergent. Dry ALL PARTS COM­PLETELY before reassembling. After any maintenance or servicing, completely reassemble unit as described in this instruction manual before reconnecting to the power supply.
CAUTION: Do not use gasoline, benzine, thinner, harsh clean-
ers, etc. as they will damage the Fan. NEVER use ALCOHOL OR SOLVENTS. LUBRICATION: Precision bearings are sealed at the factory for life
and will not require any further lubrication. STORAGE: Store the Fan, with these instructions, in a cool, dry
place. SERVICING: All other servicing, with the exception of general user-maintenance, should be performed by an authorized service representative.
1
11
Figure 3
16
15
14
13
5
4
7
17
9
6
3
2
8
REPLACEMENT PART LIST
PART NO. FOR MODEL
REF
NO. DESCRIPTION 4DA35B/9102B 4DA36B/9106B Qty
12
QTY.
1 Motor 02035053 02035052 1 2 Rotary Switch 02055087 02055087 1 3 Crimp Connect 7091854 7091854 1 4 Elevation Spring - 02090586 1 5 Ratchet Plate 02010162B 02010162B 1 6 Neck Bolt 02090521 02090521 1 7 5/16-24 Hex Nut 02090033 02090033 1 8 Stand 2010540P 2010541 1 9 Switch Knob 2010131 2010131 1 10 Bottom Plate 2010313 2010315 1 11 Power Supply Cord w/Plug 02050009FPB 02050009FPB 1 12 Front Grill 02096217 020962141 1 13 Spinner 2010093 2010093 1 14 Fan Blade 2010008 2011013 1 15 Plastic Nut 2010359P 2010359P 1 16 Plastic Rear Grill 2011212 2011200M 1 17 Grill Ornament 02010381A 02010381A 1 18 Rubber Foot 2010415 2010415 2 19 Screw #8 X 9/16 PPH 2090039 2090039 1
10
19
18
2 Rev. F 10/09
2084067
Loading...