Air King 4C631Q/9016Q Operating Manual

MODELO 4C630P/9012P y 4C631Q/9016Q
OPERATING INSTRUCTIONS & PARTS MANUAL
1
2
3
4
Rev. G 9/09
13
21
WALL MOUNTED OSCILLATING FANS
9
2
3
10
5
6
8
7
7
11
12
15
14
18
17
16
18
24
19
20
LISTA DE REPUESTOS
Ref. Parte No. for Modelo
No. 4C630P/9012P 4C631Q/9016Q Descripción Cant.
1 2060316 2060316 Placa de Montaje 1 2 2090003 2090003 T 3 02090045A 02090045A Tornillo Phillips Tipo 25 #8 x 3/4" 6 4 02090272 02090272 Pata de Caucho 2 5 2060202 2060202 Placa T 6 2010554 2010554 T 7 2090008 2090008 T 8 02055047 02055047 Interruptor con Cordón Accionador 1 9 7091854 7091854 Plastico Pr 10 2010512P 2010512P Cuerpo 1 11 2090539 2090539 Casquillo del Cor 12 02090744 02090744 Tire Cuerda 1 13 02035035 02035036 Conjunto de Motor 1 14 02010162B 02010162B Placa de Trinquete 1 15 02090518 02090518 Resorte de Elevación 1 16 02090521A 02090521A Eje de Elevación 1 17 02090033 02090033 Tuerca Hexagonal 1 18 02010548A 02010548A Boton Tipo H.C. 2 19 2010131 2010131 Botón del Interruptor (Rotatorio) 20 02050009FPB 02050009FPB Cordón Eléctrico 1 21 2011212 2011200M 22 2010359 2010359 T 23 2010008 2011013 Aspa 1 24 2010058 2010090 T 25 02096217 02096214 26 02010381A 02010381A Ornamento 1
8
22
23
24
25
26
ornillo Phillips #8 x 1-1/4" 2
racera para Colgar 1 apa del Interruptor 1 ornillo Phillips #8 x 1/2" 2
otector 2
dón Accionador 1
Rejilla Plástica Trasera 1
uerca de Seguridad 1
apa 1
I Rejilla Frontal 1
1
2084077
12" (30,4 cm) MODEL 4C630P/9012P 16" (40,6 cm) MODEL 4C631Q/9016Q
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DE-
SCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY
WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
DESCRIPTION
Air King® 12" (30,4 cm) and 16" (40,6 cm) Wall Mounted Oscillating Fans offer rotary knob/pull cord speed control, variable oscillation, a permanent split capacitor motor and OSHA-complying front steel mesh grill with a 6 ft (1,8m) 18/3 cord set.
SPECIFICATIONS
120V Blade diameter
16" (40,6 cm) Model 4C631Q/9016Q Speeds Control Air flow distribution Approvals meets OSHA r
M RPM 1470 1320 1100 1411 1280 1110 Amps 0.46 0.37 0.32 0.80 0.57 0.47 Watts 51 44 39 87 70 57 dBA 45 41 36 51 47 42
GENERAL SAFETY INFORMATION When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock and injury to person, including the following:
1. Read all instructions before using Fan.
2. Make certain that the power source conforms to the electrical
3. Use this Fan only as described in this manual. Any other use
4. Unplug power cord before installing, servicing, or moving the
WARNING: DO NOT DEPEND UPON THE ON-OFF SWITCH AS THE SOLE MEANS OF DISCONNECTING POWER WHEN INSTALLING OR SERVICING THE FAN. ALWAYS UNPLUG THE POWER CORD.
5. This Fan must NOT be used in potentially dangerous
6. DO NOT use Fan in or near a window. Rain may create an
7. The power cord is equipped with a three-prong grounded
Rev. G 9/09
...............................3
...............................Rotary Knob/Pull Cord
MODEL
SPEED
CFM 940 800 700 1510 1380 1190
3
/s 0.44 0.38 0.33 0.71 0.65 0.56
requirements of the Fan.
not recommended by the manufacturer may cause fire, electrical shock, or injury to persons.
Fan.
locations such as flammable, explosive, chemical-laden or wet atmospheres.
electrical hazard.
plug that must be inserted into a matching receptacle. Under no circumstances should the grounding prong be cut off the plug. Where a two-prong wall receptacle is encountered, it must be replaced with a properly grounded three-prong re­ceptacle installed in accordance with the National Electrical Code (NEC) and all applicable local codes and ordinances.
...................12" ( 30,4 cm) Model 4C630P/9012P
...........90°
...........................ETL Listed. Close mesh Fan Guard
4C630P/9012P 4C631Q/9016Q
HIGH MED LOW HIGH MED LOW
, 60 Hz (16" 40,6 cm)
equirements.
This work must be done only by a qualified electrician, using copper wire only.
WARNING: USE OF A THREE-PRONG TO TWO-PRONG ADAPTER IS NOT RECOMMENDED. IMPROPER CONNECTION MAY CRE­ATE THE RISK OF ELECTRIC SHOCK. USE OF SUCH ADAPTERS IS NOT PERMITTED IN CANADA. WARNING: THE RISK OF FIRE, ELECTRIC SHOCK AND PERSONAL INJURY, DO NOT REMOVE, REPLACE, REPAIR OR TAMPER WITH THE ORIGINALLY SUPPLIED PLUG. IF THE FAN DOES NOT FUNCTION PROPERLY, IT MAY BE DUE TO THE SAFETY DEVICE INCORPORATED IN THIS PLUG.
8. Where possible, avoid the use of extension cords. If they must be used, minimize the risk of overheating by ensuring that they are UL listed. Never use a single extension cord to operate more than one Fan.
9. NEVER operate any Fan with a damaged cord or plug or after the Fan malfunctions, has been dropped or damaged in any manner.
10.Do not insert or allow fingers or foreign objects to enter any ventilation or exhaust opening as it may cause an electric shock or fire, or damage the Fan. Do not block or tamper with the Fan in any manner while it is in operation.
11.Always place the Fan on a stable, flat, level surface when operating, to avoid the chance of the Fan overturning. Locate the Power Cord so the Fan or other objects are not resting on it. Do not run Power Cord under carpeting. Do not cover Power Cord with throw rugs, runners, or the like. Arrange Power Cord away from room traffic and where it will not be tripped over.
12.This Fan is not intended for use in wet or damp locations. Never locate a Fan where it may fall into a bathtub or other water container.
13.Do not use Fan outdoors.
14.This Fan is not suitable for use in agricultural facilities including areas where livestock, poultry or other animals are confined. Please refer to National Electric Code (NEC) Article 547-7 (2008), or applicable state or local codes or standards relating to electrical requirements for Agricultural Buildings. THIS FAN
DOES NOT MEET THE REQUIREMENTS OF NEC ARTICLE 547-7 (2008).
15.This Fan is not suitable for use in hazardous locations. Please refer to National Electric Code (NEC) Article 500 or applicable state or local codes or standards relating to electrical requirements for Hazardous locations. THIS FAN DOES NOT
MEET THE REQUIREMENTS OF NEC ARTICLE 500 (2008).
WARNING: REDUCE THE RISK OF FIRE OR ELECTRIC
THIS PLUG IS A SAFETY FEATURE. TO REDUCE
SHOCK – DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICES.
SAVE THESE INSTRUCTIONS
1
2084077
MODEL 4C630P/9012P and 4C631Q/9016Q
MODELO 4C630P/9012P y 4C631Q/9016Q
Detail 1
Motor
Rear
Grill
Plastic
Nut
Blade
Groove
Detail 2
Spinner
Pin
Front
Grill
Ornament
GARANTÍA LIMITADA
QUÉ CUBRE ESTA GARANTÍAS: Este producto está garantizado contra defectos de mano de obra y/o materiales. CUÁNTO DURA ESTA GARANTÍA: Esta garantía se extiende únicamente al comprador original del producto y dura un (1) año a partir de
la fecha original de compra o hasta que el comprador original del producto venda o transfiera el producto, cualesquiera de ambas que ocurriera en primer lugar.
QUÉ HARÁ AIR KING: Durante el período de garantía, Air King, a opción propia, reparará o reemplazará cualquier parte o partes que
demuestren ser defectuosas o reemplazará el producto completo por el mismo modelo u otro comparable.
QUÉ NO CUBRE ESTA GARANTÍA: Esta garantía no tiene validez si el producto fue dañado o falló debido a un accidente, manipulación u
operación inadecuadas, daño en el envío, abuso, mal uso, reparaciones no autorizadas hechas o el intento de hacerlas. Esta garantía no cubre los costos de envío para la devolución de productos a Air King para su reparación o reemplazo. Air King abonará los cargos de envío de devolución a Air King con posterioridad a las reparaciones o el reemplazo bajo garantía.
CUALESQUIERA Y TODAS LAS GARANTÍAS, EXPLÍCITAS O IMPLÍCITAS (INCLUYENDO, SIN LIMITACIÓN, CUALESQUIERA GARANTÍA IMPLÍCITA DE COMERCIABILIDAD), DURAN UN AÑO A PARTIR DE LA FECHA ORIGINAL DE COMPRA O HASTA QUE EL COMPRADOR ORIGINAL DEL PRODUCTO VENDA O TRANSFIERA EL PRODUCTO, CUALESQUIERA DE AMBAS QUE OCURRIERA EN PRIMER LUGAR Y EN NINGÚN CASO LA RESPONSABILIDAD DE AIR KING BAJO CUALQUIER GARANTÍA EXPLÍCITA O IMPLÍCITA INCLUIRÁ (I) DAÑOS INCIDENTALES O POR CONSECUENCIA POR CUALQUIER CAUSA QUE FUERE, O (II) REEMPLAZO O REPARACIÓN DE CUALESQUIERA FUSIBLES HOGAREÑOS, CORTA-CIRCUITOS O TOMACORRIENTES. INDEPENDIENTEMENTE DE CUALQUIER DECLARACIÓN CONTRARIA, EN NINGÚN CASO LA RESPONSABILIDAD DE AIR KING BAJO CUALQUIER GARANTÍA EXPLÍCITA O IMPLÍCITA PODRÁ EXCEDER EL PRECIO DE COMPRA DEL PRODUCTO Y DICHA RESPONSABILIDAD TERMINARÁ AL VENCIMIENTO DEL PERÍODO DE GARANTÍA.
Algunos estados y provincias no permiten limitaciones sobre la duración de una garantía implícita, o sobre la exclusión o limitación de los daños incidentales o por consecuencia, por lo tanto dichas exclusiones o limitaciones podrían no aplicarse en su caso. Esta garantía le otorga a usted derechos legales específicos. Usted también podría tener otros derechos que varían de estado en estado y de provincia en provincia. Se requiere prueba de compra antes que se acepte un reclamo bajo garantía.
ASSEMBLY (Figure 1)
1. Put Rear Grill on Motor by aligning the tab on the Rear Grill with the groove on the Motor. (Detail 1)
2. Fully seat Rear Grill on Motor and secure with Plastic Nut turning Clockwise.
3. Slide
4. To secure
5. Snap Front Grill into place.
Blade onto Motor Shaft. (Align groove on blade hub with
pin on motor shaft.) (Detail 2)
Clockwise until tight on
Blade, screw Spinner onto Shaft Counter
Blade hub.
INSTALLATION
1. Locate a stud behind wall. If stud cannot be found, special types of mounting anchors are available at your hardware store.
2. Secure Mounting Plate to wall with Screws supplied (#8 X 1 1/4" Wood Screws). Make sure flange is pointing up as shown in exploded view above.
3. Fan is now ready to hang on Mounting Plate.
OPERATION
VARIABLE OSCILLATION: Pull oscillation knob on the rear of the motor up. Turn fan head to left, right, or straight ahead. Push oscil­lation knob down and fan will oscillate about the set angle. VERTICLE ANGLE: To adjust vertical angle, tilt fan head up or down, as desired.
Rev. G 9/09
SPEED: Speed is controlled by a pull-cord switch. The speed setting is shown by switch knob on front cover. (Off-Low-Med-High-Off) POWER SUPPLY CORD: Plug power supply cord into a wall outlet (AC 120Volts, 60 Hz).
MAINTENANCE
WARNING: ALWAYS UNPLUG THE CORD BEFORE MOV-
ING OR SERVICING THE FAN.
WARNING: DO NOT IMMERSE FAN IN WATER!
CLEANING: Use a soft cloth moistened with a mild soap solu-
tion, such as liquid dish washing detergent. Dry ALL PARTS COM­PLETELY before reassembling. After any maintenance or servicing, COMPLETELY REASSEMBLE unit as described in this instruction
manual before reconnecting to the power supply.
CAUTION: Do not use gasoline, benzine, thinner, harsh
cleaners, etc. as they will damage the Fan. NEVER use ALCOHOL OR SOLVENTS.
LUBRICATION: Precision bearings are sealed at the factory for
life and will not require any further lubrication.
STORAGE: Store the Fan, with these instructions, in a cool, dry
place.
2
2084077
Rev. G 9/09
7
2084077
Loading...
+ 2 hidden pages