Recessing fan in the wall
The iCON 15S requires a 110mm diameter hole through the
wall lined with a 100mm internal diameter duct.
The iCON 30S requires a 110mm diameter hole through the
wall, counter board 160mm to a depth of 80mm. The hole
should be lined with a 100mm internal diameter duct.
Surface mounting fan on the wall
When surface mounting the iCON 30S the supplied mounting
skirt should be used.
The iCON 30S requires a 110mm diameter hole through the
wall lined with a 100 mm internal diameter duct.
Ensure all vapour barriers are properly restored.
Ceiling Surface Mounting
When surface mounting the iCON 30S, the mounting skirt
provided should be used. The mounting skirt should be fixed,
with the screws provided, into the support. The fan is then
fitted into the skirt.
The iCON 30S requires a 110mm diameter hole through the
ceiling.
When recessing or surface mounting in the ceiling, a plywood
support (min. 18mm thick) must be mounted between the
ceiling joists. Any fixing screws should be fitted through the
plaster board into the support.
Measurements and Commissioning
The Building Regulations 2010, imposes a requirement that
testing and reporting of mechanical ventilation performance
(see Approved Document F1) is conducted in accordance with
an approved procedure.
Compliance with this requirement by an assessed and registered ‘Competent Person’ should follow a ‘Best Practise’ process and adopt air flow measurement, Method A - The Unconditional Method - using a suitable UKAS certified measuring
instrument. Generically referred to as ‘Zero Pressure Air Flow
Meter’ or ‘Powered Flow Meter’.
Further information on this method is detailed in NHBC Building Regulations Guidance Note G272a 10/13 and BSRIA
Guide document BG 64/2016.
Installation with flexible ducting
Where flexible ducting is used the diameter must be maintained and it is good ventilation practice that the ducting is
extended to a minimum of 90% its possible length in order to
maintain the best possible air flow.
Ensure that flexible duct connections are not over tightened to
the spigots.
To maximise the air flow rigid ducting should be used where
possible. The fan and ducting should be installed in accordance with the requirements of the Domestic Ventilation Com-
pliance Guide, part of the Building Regulations.
SAFETY FIRST: ALWAYS ISOLATE THE FAN UNIT FROM
THE POWER SUPPLY BEFORE DOING ANY WORK ON
THE FAN/MODULE.
When installed according to these instructions the iCON range
is completely safe. The materials used do not constitute a
hazard.
Cleaning
Fan and ducting should be inspected and cleaned on a
regular basis to keep fan performance. The external hous-
ing of the fan can be wiped with a damp cloth. Do not use
household cleaners containing abrasives. Cleaning of the
internal parts such as the impeller should be carried out by
using a soft brush. Never clean any parts of the fan assembly
by immersing in water or using a dishwasher.
Warning
This appliance can be used by children aged from 8 years and
above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have
been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved.
Children should not play with the appliance. Cleaning and user
maintenance shall not be carried out by children without adult
supervision.
Airflow Developments Ltd guarantees the iCON for 3
years from date of purchase against faulty material or
workmanship. Applicable to units installed and used in the
United Kingdom.
You can register your warranty online (for more information
check at www.airflow.com).
Warranty only covers the fan, not the reinstallation if required.
In the event of any defective parts being found, Airflow Developments Ltd reserve the right to repair or at our discretion
replace without charge provided that the unit:
1. Has been installed and used in accordance with the fitting
and wiring instructions supplied with each unit.
2. Has not been connected to an unsuitable electrical supply.
3. Has not been subjected to misuse, neglect or damage.
4. Has not been modified or repaired by any person not au-
thorised by Airflow Developments Ltd
5. Has been installed in accordance with latest Building Regu-
lations and IET wiring regulations by a person who is recognised as a competent installer who is part of a competent
scheme provider (e.g. NICEIC Ventilation Scheme).
UK Head-Office
AIRFLOW DEVELOPMENTS Ltd
Aidelle House, Lancaster Road
Cressex Business Park
High Wycombe
Buckinghamshire
HP12 3QP
United Kingdom
Tel: +44 (0) 1494 525252
Email: info@airflow.com
Web: www.airflow.com
Czech Republic
AIRFLOW LUFTTECHNIK GmbH
o.s. Praha
Hostýnská 520
108 00 Praha 10
Malešice
Czech Republic
Tel: +42 (0) 2 7477 2230
Email: info@airflow.cz
Web: www.airflow.cz
Germany
AIRFLOW LUFTTECHNIK GmbH
Wolbersacker 16
53359 Rheinbach
Germany
Tel: +49 (0) 222 69205 0
Email: info@airflow.de
Web: www.airflow.de
© Airflow Developments Ltd.
Airflow Developments Limited reserve the right, in the interests of continuous development, to alter specifications without prior notice. All orders are accepted subject to our
conditions of sale which are available on request.
Page 9 of 16
Wall Installation
iCON 15S iCON 30S (R)
Ceiling Installation
Page 10 of 16
Ceiling Recess
The fan should be fitted in the hole, fixed with the screws
provided into the support.
The iCON 15S requires a 110mm diameter hole through the
ceiling.
The iCON 30S requires a 160mm diameter hole through the
ceiling.
Where flexible duct is used the diameter must be maintained.
Possible cable
routing
Duct
Joist
Ceiling
Plywood
Ceiling Installation
Page 11 of 16
Possible cable
routing
Duct
Joist
Ceiling
Plywood
Mounting skirt
Best Practise Recommendations
Page 12 of 16
Best Practice Recommendations
Page 13 of 16
Page 14 of 16
Maintenance
Page 15 of 16
Warranty
www.airflow.com
80000439 Issue 2 08/21
Airflow Developments Ltd shall not be liable for any loss,
injury or other consequential damage, in the event of a
failure of the equipment or arising from, or in connection
with the equipment excepting only that nothing in this condi-
tion shall be construed as to exclude or restrict liability for
negligence.
This warranty does not in any way affect any statutory or
other consumer rights.
For detailed standard warranty terms and conditions
see our website or contact Customer Service.
To avoid the backflow of condensation into the fan in ceiling
installations it is good practice to fit a condensation trap to
the vertical outlet duct of the fan.
With through the wall installation fit the duct in an approx.
5° angle down to outside.
Plastic
Condensation
trap
Outlet
Fan