Airflow AV125T Fan With Kit, AV100T Fan With Kit, AV100T Fan With Kit & LED, 9041407, 9041406 Installation Instructions

...
AV100T Fan With Kit 9041407 AV125T Fan With Kit 9041406 AV100T Fan With Kit & LED 9041408
Aventa Fan Dimensions
Page 2 of 16 Page 3 of 16
Page 4 of 16
Aventa In-line Mixed Flow fans are available in 3 model sizes with or without timer function and have
2 speeds.
Aventa In-line Mixed Flow fans can be used as a simple extract or supply fan where high pressure and flow rates are required. They can be mounted vertically with a condensation trap fitted or horizontally. The range has been designed to accept standard ducting sizes. The main body of the fan (1) is detachable from the inlet and outlet spigots and mounting assembly via the 2 clamps
Page 5 of 16
Page 7 of 16
Mechanical installation
Determine the orientation of the fan airflow direction
by the use of the flow direction arrow on the fan body (1). (See diagram on page 3). Remove the fan body by releasing the 2 clamps (6). Using the mounting base as a guide mark and drill 4 holes. Use the wall plugs and screws provided and secure the mounting base to the mounting surface. Insert the fan body (1) and secure with the retaining clamps (6). (See diagram on page 3). Connect the appropriately sized ducting to the spigot ducts. Airflow Developments Ltd recommends that rigid ducting is used instead of flexible ducting, this will help to ensure maximum performance.
Type
Air flow,
m3/h
Current,
Amps
Power,
Watts
Noise
level,
db(A) @
3m
AV 100/T 145/187 0.11/0.21 21/33 27/36
AV 125/T 220/280 0.18/0.27 23/37 28/37
Fan Specicaon
Electrical installation
The Aventa In-line Mixed Flow range is IPX4 rated and is suitable for mounting in Zone 2 in bathrooms,
toilets, kitchens, utility rooms when installed with a
30mA RCD. The fan requires a 230V 50Hz single phase supply. Class II equipment. BS EN 60417. An external 3A fuse is required for each fan unit. Cable sizes (max): Fixed flat wiring 2 core 1mm2, 3 core 1/1.5mm2. All electrical installation to be carried out by an approved electrician in accordance with Part PU.K. Building Regulations and to the latest IEEE standards, or the appropriate regulations in the country of installation.
Important
The Aventa In-line Mixed Flow fan range is IPX4 rated and complies with the requirements of the EU
norms and directives. Do not place the fan unit near
direct heat sources, e.g. radiant heaters, or where temperatures can exceed 40°C (104°F). Precautions must be taken to avoid back flow of gases in rooms with open flue fuel burning appliances.
Page 8 of 16
Aventa In-line Fan With Kit
230V Fan With Kit Installation and Operating Guide
Terminal Blocks Guide
AV100T , AV 125T Fan With Kit
Min Speed
Max Speed
Page 6 of 16
Electrical installation
N Neutral L Permanent Live LT Switch Live High Speed L1 Switch Live Low Speed
AV100T Fan With Kit & LED
Electrical installation
N L
N L
N L
N L
Max Speed
Min Speed
Fan Timer Adjustment
The fan with timer function switches on when the
voltage is supplied to the LT or L1 terminal via an external switch. After the voltage to the LT or L1 terminal is disconnected the fan continues to run for the set Run on timer period, between 1 and 20 minutes. The Run on timer is factory set to 15 mins, it is adjusted by turning the potentiometer (T) clockwise to increase and anti-clockwise to decrease.
T
Increase
Decrease
2 Pole
isolator
3 Amp
Switched Fuse
3 Amp
Switched Fuse
2 Pole
isolator
2 Pole
isolator
2 Pole
isolator
3 Amp
Switched Fuse
3 Amp
Switched Fuse
L N
L N
L N
12V DC
L N
LED Driver
LED Driver
12V DC
Red Cable
Black Cable
Red Cable
Black Cable
Page 10 of 16 Page 11 of 16
Page 14 of 16
Page 15 of 16
Page 16 of 16
Page 9 of 16
Page 13 of 16
Warranty
Applicable to units installed and used in the United Kingdom. Airflow Developments Ltd guarantees the Aventa in-line for 3 YEARS from date of purchase against faulty material or workmanship. Warranty only covers the fan, not the reinstallation of this if required. In the event of any defective parts being found, Airflow Developments Ltd reserve the right to repair or at our discretion replace without charge provided that the unit:
1. Has been installed and used in accordance with the fitting and wiring instructions supplied with each unit.
2. Has not been connected to an unsuitable electrical supply.
3. Has not been subjected to misuse, neglect or damage.
4. Has not been modified or repaired by any person not authorised by Airflow Developments Ltd
5. Has been installed in accordance with latest
Building Regulations and IEEE wiring regulations by a
recognised competent installer. Airflow Developments Ltd shall not be liable for any loss, injury or other consequential damage, in the event of a failure of the equipment or arising from, or in connection with, the equipment excepting only that nothing in this condition shall be construed as to exclude or restrict liability for negligence.
This warranty does not in any way affect any statutory or other consumer rights.
Maintenance
SAFETY FIRST: ALWAYS ISOLATE THE FAN UNIT FROM THE POWER SUPPLY BEFORE REMOVING
THE COVER.
When installed according to these instructions the Aventa in-line range is completely safe. The materials used do not constitute a hazard.
Cleaning
The external housing of the fan can be wiped with a damp cloth. Do not use household cleaners containing abrasives. Note: Always isolate the fan when cleaning. Never clean any parts of the fan assembly by immersing in water or using a dishwasher.
Warning
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Page 12 of 16
Recommended Best Practice
The Building Regulations 2010, Statutory Instrument Part 9, paragraph 42, imposes a requirement that
testing and reporting of mechanical ventilation
performance is conducted in accordance with an approved procedure. Compliance with this requirement by an assessed and registered Competent Personshould follow a Best Practiceprocess and adopt air flow measurement, Method A – The Unconditional Method – using a suitable UKAS certified measuring instrument. Generically referred to as a Zero Pressure Air Flow Meteror Powered Flow Meter’. Further information on this method is detailed in NHBC Building Regulations Guidance Note G272a 10/13 and BSRIA A Guide to Measuring air flow rates document BG46/2015
Installation with flexible ducting
Where flexible ducting is used the diameter must be
maintained with the minimum radius of a bend equal to the diameter of the ducting. It is good ventilation practice that the ducting is extended to 90% of its possible length in order to maintain the best possible airflow. Ensure that flexible duct connections are not over tightened to the fan outlet spigot. To maximise airflow rigid ducting should be used where possible. The fan and ducting should be installed in accordance with the requirements of the Domestic Ventilation Compliance Guide, part of the Building Regulations.
UK Head-Office
AIRFLOW DEVELOPMENTS Limited Aidelle House, Lancaster Road Cressex Business Park High Wycombe Buckinghamshire HP12 3QP United Kingdom
Tel: +44 (0) 1494 525252 Fax : +44 (0) 1494 461073 Email: info@airflow.com Web: airflow.com
Czech Republic
AIRFLOW LUFTTECHNIK GmbH organizační složka Praha Hostýnská 520 108 00 Praha 10 Czech Republic
Tel: +42 (0) 2 7477 2230 Fax: +42 (0) 2 7477 2370 Email: info@airow.cz Web: airow.cz
Germany
AIRFLOW LUFTTECHNIK GmbH Wolbersacker 16 53359 Rheinbach Germany
Tel: +49 (0) 222 69205 0 Fax: +49 (0) 222 69205 11 Email: info@airow.de Web: airow.de
AIRFLOW DEVELOPMENTS LTD reserve the right in the interest of connuous development to alter any or all spec icaons without
80001054 Issue 1 03/21
Loading...