Airflow 9041348, Aura 100B, 9041349, 9041353, 9041352 Installation Instructions

...
Fan Dimensions
Range Overview
Electrical Installation
Aura
Fan Range Installation and Operating Guide
Aura 100B - 9041347 Aura 100T - 9041348 Aura 100HT - 9041349 Aura 100MST - 9041350
Aura 125B - 90000532 Aura 125T - 90000533 Aura 125HT - 90000534 Aura 125MST - 90000535
Aura 150B - 9041351 Aura 150T - 9041352 Aura 150HT - 9041353 Aura 150MST - 9041354
Electrical Installation
Aura 100/125/150 Basic and MST
Wiring for fans with no external switching
Aura 100/125/150 Timer and Humidity Timer
Wiring for fans with external switching
Note: An external switch can be connected to the Live for Aura 100B fans.
Page 5 of 16 Page 6 of 16 Page 7 of 16 Page 8 of 16
Model A B C D E
Aura 100 150 102
Aura 125 176 87 125
Aura 150 205 124 150
100
D
122 17
141
174
19
19
1
5
2
Page 2 of 16
3
4
1.Cover, 2.Casing,
3.Motor 4. Impeller,
5.Control.
Mechanical Installation
Aura fans can be wall mounted.
For mounting the fan, a ø100/125/150mm hole is required for the spigot, as well as at least two holes for the mounting screws. When mounting the fan, remove the front cover and place the fan into the pre drilled hole. Make sure that the spigot fits into any pre-installed ducting. Wire the fan appropriately according to page 5, ensuring that the cables from the fan are routed through the provided cable hole.
Use at least two mounting screws to secure the fan to the ceiling or wall ensuring not to over tighten and replace the front cover with the retention screw. Ensure free running of the fan impeller and that flexible duct connections are not over tightened to the fan outlet spigot.
Airflow recommends that rigid ducting is used instead of flexible ducting, this will ensure maximum performance.
Aura fans are designed for ventilation of domestic premises i.e. toilets, bathrooms, utility rooms and
kitchens. They are recommended for 'through the wall' installation.
The Aura 100/125/150B models may be used as a simple extract fan operated by a remote switch.
The Aura 100/125/150T models include adjustable timer function 2 to 30 minutes.
The Aura 100/125/150HT models includes an adjustable timer function 2 to 30 minutes and an adjustable humidity function 60 to 90% RH.
The Aura 100/125/150MST models includes adjustable timer function 2 to 30 minutes and motion sensing.
Fan Size
100mm
125mm
150mm
Max flow,
m3/h
70
115
235
Max Pressure
Pa
25 5.6 26
55
86 20
Page 3 of 16
Nominal
power, W
Noise level dB(A)
9.3
Fan Adjustment - Timer
The fan with timer function switches on when the voltage is supplied to the Ls terminal via an external switch.
After the voltage to the Ls terminal is disconnected the fan continues to run for the set run on timer period between 2 and 30 minutes. The run on timer period is adjusted by turning the potentiometer (T) clockwise to increase and anti-clockwise to decrease.
T
The Aura fan range is IPX4 rated and is suitable for mounting in Zone 2 in bathrooms, toilets, kitchens, utility rooms and inside shower cubicles when installed with a 30mA RCD. In addition AFDD
protection is also required.
The fan requires a 220 - 240V 50Hz single phase supply. Class II equipment. BS EN 60417. An external 3A fuse is required for each fan unit. Cable sizes (max): Fixed flat wiring 2 core 1mm2, 3 core 1/1.5mm
All electrical installation work to be carried out by a competent person in compliance with the relevant Building Regulations/Standards as well as the current edition of BS7671 (IET Wiring Regulations).
Important Notes
The Aura range also complies with the requirements of the EU norms and directives. Do not place the ventilator near direct heat sources, e.g. radiant heaters, or where temperatures can exceed 40°C (104°F). Precautions must be taken to avoid back flow of gases in rooms with open flue fuel burning
31
appliances.
35
Page 4 of 16
Fan Adjustment - Humidity & Timer
Humidity and timer functions are activated when the voltage is supplied to the Ls terminal via an external switch or when the humidity level rises above the set % RH level (adjustable between 60 and 90% RH). After the voltage to the Ls terminal is disconnected or the humidity level falls below the set %RH level, the fan continues to run for the set Run on timer period between 2 and 30 minutes.
T
H
The humidity level is adjusted by turning the potentiometer (H) clockwise to increase and anti­clockwise to decrease. To set the maximum humidity level the potentiometer (H) has to set at the max position (90%).
See page 7 “Fan adjustment -Timer” for timer adjustment instructions.
2
Fan Adjustment - Motion Sensor & Timer
The fan with motion sensor and timer function switches on when movement is detected between a distance of 1 and 4 meters from the fan. The sensor has a detection angle of 100° horizontally.
Once movement ceases, the fan continues to run for the set run on timer period which is adjustable between 2 and 30 minute.
Fan Assembly - Timer / Humidity & Timer
Front cover
Electronic
Control
T & HT
Fan body assembly
Front
Fan Assembly - Motion Sensor & Timer
Fan body
assembly
Through The Wall Installation
T
Page 9 of 16
Best Practice Recommendations
The Building Regulations 2010, Statutory Instrument Part 9, paragraph 42, imposes a requirement that testing and reporting of mechanical ventilation performance is conducted in accordance with an approved procedure.
Compliance with this requirement by an assessed and registered ‘Competent Person’ should follow a ‘Best Practice’ process and adopt air flow measurement, Method A – The Unconditional Method – using a suitable UKAS certified measuring instrument. Generically referred to as a ‘Zero Pressure Air Flow Meter’ or ‘Powered Flow Meter’.
Further information on this method is detailed in NHBC Building Regulations Guidance Note G272a 10/13 and BSRIA ‘A Guide to Measuring air flow
rates document BG46/2015.
Page 10 of 16
Maintenance
SAFETY FIRST: ALWAYS ISOLATE THE FAN UNIT FROM THE POWER SUPPLY BEFORE REMOVING THE COVER. When installed according to these instructions the Aura range is completely safe. The materials used do not constitute a hazard.
Cleaning
The external housing of the fan can be wiped with a damp cloth. Do not use household cleaners containing abrasives. Note: Always isolate the fan when cleaning. Never clean any parts of the fan assembly by immersing in water or using a dishwasher.
Warning
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision
Page 14 of 16 Page 15 of 16 Page 16 of 16
Electronic
control
Page 11 of 16
Warranty
Airflow guarantees the Aura for 2 years from date of purchase against faulty material or workmanship, Applicable to unites installed and used in the UNITED KINGDOM.
Warranty covers the fan, not the re-instalaltion of this if required. In the event of any defective parts being found, Airflow Developments Ltd reserves the right to repair, or at our discretion replace without charge provided the unit:
Has been installed in accordance with the fitting and wiring instructions supplied with each unit.
Has not been connected to an unsuitable electri­cal supply.
Has not been subjected to misuse, neglect or damage.
Has not been modified or repaired by any person not authorised by Airflow Developments Ltd.
Has been installed by a person who is recognised as a competent person who is part of a competent scheme provider (e.g. NICEIC Ventilation Scheme).
To maximise airflow rigid ducting should be used.
Where flexible ducting is used the diameter must be maintained and it is good ventilation practice that the ducting is extended to 90% of its possible length in order to maintain the best possible airflow. Ensure that flexible duct connections are not over tightened to the fan outlet spigot.
The fan and ducting should be installed in accordance with the requirements of the Domestic Ventilation Compliance Guide, part of the Building Regulations.
Page 12 of 16
Airflow Developments Ltd shall not be liable for any loss, injury or other consequential damage, in the event of a failure of the equipment or arising from, or in connection with, the equipment
excepting only that nothing in this condition shall be
construed as to exclude or restrict liability for negligence. Full details at airflow.com/terms
This warranty does not in any way affect any statutory or other consumer rights.