80000438 Issue 2 07/18
Modules for 230V Fan Range
Installation and Operating Guide
PCM – 72573602
TM – 72612601
DTM – 72675702
HTM – 72687103
PRTM – 72687104
PRHTM – 72687102
2SHM – 72675703
Modules available for iCON 230V Fan Range
Airflow® iCON® fans can be controlled by optional control
modules. For the 230V range you can choose between sev-
en modules.
diagram
Part no.* Model Description
72573602 PCM
72612601 TM
72675702 DTM
72687103 HTM
72687104 PRTM
72687102 PRHTM
72675703 2SHM**
* For blister pack add “B” at the end of part number.
** Not for kitchen applications with iCON 15! App roved Document Part F re-
quired continuous extract rates: 6 l/s for WC, 8 l/s for bathroom / utility room and 13 l/s
for kitchen.
Pull cord (on/off)
pull cord (latching)
Timer (run on timer)
externally switched (live trigger), timer overru n (1-30 min)
Delayed timer (delayed start, run on timer)
externally switched (live trigger), timer overru n (2-45 min), delayed
start (2 min), pull cord (latching)
Humidity timer (pull cord/humidity start, run on timer)
externally switched (live trigger), timer overru n (2-45 min), humidity
control (40-90% RH), pull cord (momentar y)
PIR timer (motion start, run on timer)
externally switched (live trigger), timer overru n (2-45 min), motion
sensor (passive infa-red)
PIR humidity timer (motion/humidity start, run on timer)
externally switched (live trigger), timer overru n (2-45 min), humidity
control (40-90% RH), motion sensor (p assive infra-red)
Two speed humidity (trickle start, pull cord/humidity boost)
externally switched (live trigger), humidity c ontrol (40-90% RH), pull
cord (latching)
SAFETY FIRST: ALWAYS ISOLATE THE FAN
UNIT FROM THE POWER SUPPLY BEFORE
DOING ANY WORK ON THE FAN/MODULE.
Page 2 of 8
A
B
B
A, B
A, B
A, B
A, B
Wiring
Electrical installation
All electrical installation must be carried out by an approved
electrician in accordance with Approved Document Part P of
U.K. Building Regulations and to the latest IET standards, or
the appropriate regulations in the country of installation (for
fan installation see the iCON 230V Fan Range Installation
and Operating Guide).
Diagram A - module wiring with no external switching
(module functionality / pull cord activation only):
Diagram B - module wiring with external switching (live
trigger connection used):
Page 3 of 8
Mechanical installation
To install the module in an iCON fan follow the instructions
below. See page 5 for instructional drawings.
1. Remove the fan front cover (see page 7).
2. Lift the fan electrical terminal away from its mounting pillars
and position on the module connector pins. Tighten the two
screws with a suitable screwdriver. Ensure the leads are
under the module retaining cable clamp.
3. Fit the module at a slight angle into the fan housing, ensur-
ing that the locating slot is fully engaged in to locating
block on the fan.
4. Push the module against housing, ensuring the module clip
holds it in place (clicks at the cable clamp). With iCON 15
& 30 the terminal will reposition back over mounting pillars.
For modules with pull cords: Ensure that the pull c ord is
properly located within the cord slot at the bottom of the fan.
For modules with PIR control: Remo ve the oval logo cap
fitted at the bottom of the front cover of the fan. Replace it
with translucent lens supplied with the PIR module. Note:
The lens must be replaced in order for the PIR module to
function properly. Ensure the orientation of the lens is correct
(i.e. the lens should be flush with the surface).
Connecting mains cable into the module
Connect the cable to the 3-way supply connector block (see
wiring diagrams on page 3) ensuring that the supplied cable
clamp is fitted. Refit the front cover.
Note: When using DTM m odule on ini tial connection the
fan will start immediately and continue running for the duration set on the timer function of the module.
Page 4 of 8

Mechanical installation
iCON module overview. A module with Timer and/or Humidistat is supplied pre-set,
Cable entry
Module adjustment
but may be adjusted by the installer. All adjustments must be
done using the supplied Adjustment Tool.
Humidity settings
The humidistat is factory pre-set at approx. 70% RH (relative
Module
locating block
humidity). Adjusting the “% RH” towards 40% will result in fan
activation at lower humidity (more sensitive). Adjusting the
“% RH” towards “90%” will result in fan activation at higher
humidity (less sensitive).
Time settings
The overrun timer is factory pre-set at approx. 15 min. Adjusting the “Timer” towards “MIN” will result in a timer overrun
decrease towards 1/2 minutes (depends on module). Adjusting the “Timer” towards “MAX” will result in a timer overrun
increase towards 30/45 minutes (depends on module).
2SHM speed settings
The bathroom/kitchen (low/high) trickle speed depends on
fan model used: 7.2/9.5 l/s (iC15), 19.2/23.4 l/s (iC30) or
21.2/25.6 l/s (iC60). You can set it by a two position slide
switch. Boost (pull cord or humidity sensor activated) will
always be fans’ maximum speed.
Humidistat
MIN = 40% RH
MAX = 90% RH
Timer
control
MIN = 1/2 min
MAX = 30/45 min
Adjustment
tool
Timer control
Humidistat
Module
locating slot
PIR lens
location
Terminal block
fitting (pillars)
3-way supply
connector
Module clip
Module cable
clamp
Two module
connector pins
iCON module
Page 5 of 8 Page 6 of 8
Front cover removal
3
To remove front cover assembly, first make sure the fan is
off, isolated from the power supply and the iris shutter is
fully closed.
1. Undo the locking screw at the bottom edge of the cover
using a screwdriver.
2. Rotate the cover a few degrees anticlockwise until it clicks
out from the fittings.
3. Remove the cover by pulling it out.
To refit the cover, reverse the above procedure. The iris
shutter should be in closed position after refit. If not, wait
approximately 1 min after fan switch off allowing the actuator
to retract back in the closed position and then refit the cover
again.
Page 7 of 8
2
1
Warranty
Applicable to units installed and used in the United Kingdom.
Airflow Developments Ltd guarantees the iCON range for
3 years (incl. modules) from date of purchase against
faulty material or workmanship. You can register your
warranty on-line (for more information check at
www.airflow.com). Warranty only covers the product, not a
reinstallation if required.
For detailed standard warranty terms and conditions see
our website or contact Customer Service.
UK Head-Office
AIRFLOW DEVELOPMENTS Ltd
Aidelle House, Lancaster Road
Cressex Business Park
High Wycombe
Buckinghamshire
HP12 3QP
United Kingdom
Tel: +44 (0) 1494 525252
Email: info@airflow.com
Web: www.airflow.com
© Airflow Developments Ltd.
Airflow Developments Limited reserve the right, in the interests of continuous development, to alter specifications without prior notice. All orders are accepted subject to our
conditions of sale which are available on request.
Czech Republic
AIRFLOW LUFTTECHNIK GmbH
o.s. Praha
Hostýnská 520
108 00 Praha 10
Malešice
Czech Republic
Tel: +42 (0) 2 7477 2230
Email: info@airflow.cz
Web: www.airflow.cz
www.airflow.com
Germany
AIRFLOW LUFTTECHNIK GmbH
Postfach 1208
D-53349 Rheinbach
Germany
Tel: +49 (0) 222 69205 0
Email: info@airflow.de
Web: www.airflow.de