irow Developments LTD, High Wycombe, HP12 3QP. UK.
Input: 100-240v AC 50~60Hz
O
utput: 12v DC regulated
M
ax Ambient Temperature: 40°C
I
P55
P
art Number: 9041336
E
mail: info@airow.co.uk Web: airow.com
1
2v Output
to fan
2
30V Mains
i
nput
P
ower Supply Unit
Brown
G
rey
B
lack
Brown
G
rey
B
lack
B
rown
G
rey
B
lack
B
rown
G
rey
Black
L
ive
Neutral
Switched
L
ive
+
12V
-0V
S
witched
+12V
A
L
N
N
LS
L
L
T
N 0v
LS +12v
RCD
GB
omestic DC Fans – iCON SELV/iCON eco S
D
nstallation and Operating Guide
I
12V SELV Base Models:
CON eco15S – 72683701
i
iCON eco30S – 72683801
iCON 15 Selv – 72591801
CON 30 Selv– 72591901
i
9041549
eco
Issue 3
6/10
0
iCON eco15S iCON 15 SELV iCON 30 SELV
Airflow 12v iCON SELV and iCON eco S Domestic Fan
Installation, Maintenance and Use
iCON SELV (Safety Extra Low Voltage) and iCON eco S fans are available in 2 model
izes and can be fitted to a wall or ceiling. Each fan requires a suitable size hole through
s
the wall or ceiling which connects into a duct venting to the outside. The external opening
should be covered by a suitable external grill, available separately from Airflow
Developments Ltd..
Airflow iCON SELV and iCON eco S Model Options
Model iCON eco15S -100mm Axial Fan with maximum capacity of 21.9 l/sec.
odel iCON eco30S -100mm Mixed Flow Fan with maximum capacity of 34.25 l/sec
M
Model iCON 15 SELV -100mm Axial Fan with maximum capacity of 19.5 l/sec.
odel iCON 30S SELV -100mm Mixed Flow Fan with maximum capacity of 31 l/sec
M
he iCON SELV and iCON eco S range can be used as a simple extract fan powered via
T
he SELV transformer unit, and connected to either a remote switch, or can be fitted with
t
an internal control module, supplied to give a range of control options including timer,
humidity, motion sensor, pull cord, trickle speed or combinations of these functions.
ptional modules are available separately and can be fitted at the time of installation or
O
retrofitted.
The iCON SELV and iCON eco S fans have IP X4 rated housings, they are doubleinsulated and are suitable for fitting in Zone 1 or 2 of bathrooms, toilets, kitchens, utility
rooms and inside shower cubicles as defined in Section 701 BS7161:2008 (IEEE Wiring
Regulations, Seventeenth Edition ). The iCON SELV and iCON eco S also complies with
the Building Regulations, Approved Document F. The transformer unit, supplied with the
fan, must be fitted outside of Zones 0, 1 and 2. It is usually installed outside the room.
Do not place the fan near direct heat sources, e.g. radiant heaters, or where temperatures
can exceed 40°C (104°F).
Page 2 of 8
The iCON SELV transformer unit has a thermal protection device internally fitted, and an
external 3A fuse is required for each transformer unit; therefore no internal fuse is fitted to
the fan unit.
The iCON eco S power supply has resettable over current and short circuit protection. An
external 3Amp fuse is still required with each power supply. The eco S (power supply) has
a Led indicator to show that the unit is switched on and functioning correctly.
he transformer requires a 230V 50Hz single phase supply and has a 12V dc output for
T
the iCON eco SELV fan. Class II equipment. BS EN 60417.
ote: Switches for fans shall be selected and sited in accordance with BS7161:2008
N
All electrical installation to be carried out by an approved electrician in accordance with
art “P” U.K. Building Regulations and to the latest IEEE standards, or the appropriate
P
regulations in the country of installation.
LWAYS ISOLATE THE TRANSFORMER AND FAN UNITS FROM THE POWER
A
UPPLY BEFORE REMOVING THE COVER.
S
Mechanical Installation
ransformer
T
The iCON SELV transformer unit should not be fitted in Zone 0, 1 or 2 and must be sited
ut of reach of anyone using the bath, shower or sink. The units are usually installed
o
utside the room or in an accessible roof space with adequate circulation of air around the
o
transformer unit to avoid overheating.
he maximum distance between the transformer and fan units, when using 1.5mm2 cable
T
is 5m.
• Unscrew 2 retaining screws and
remove the cover.
• Using the transformer base, spot
through the fixing holes (A, B or C).
Note: Choice of fixing positions (A, B
or C) depends on the location.
Ceiling or wall mounting: Drill to
•
accept plastic wall plugs and screw
the transformer unit to the support
using the 2 mounting screws (Pan
head, self tapping: 4mm x 32 long)
supplied in fixing kit.
• Roof space: Screw the transformer
unit to the support using the 2
mounting screws (Pan head, self
tapping: 4mm x 32 long) supplied in
the fixing kit.
• The 230V mains cable can be routed into the transformer unit via the knock out positions
D (bottom), G (side) or F (side); whichever is most convenient.
Page 3 of 8 Page4 of 8
The output cable to the fan, typically is 1.5mm2 for a 5m cable run, can be routed into the
•
transformer unit via the positions E (bottom), H (side) or I (side); whichever is most
onvenient.
c
Note: Never cover the transformer unit with thermal insulation or other materials.
CON eco S Power Supply Unit
i
he iCON eco S power supply unit does not require dismantling and should be installed by
T
qualified electrician to BS7161:2008 (IEEE wiring standards 17th Edition). The maximum
a
length of wire between the power supply and the fan should not exceed 5m using 1.5mm2
wire.
Fan Unit
he iCON SELV and iCON eco S range can be
T
ecessed in a wall or ceiling. A mounting skirt is
r
provided for surface mounting the iCON 30
ELV and iCON eco30S.
S
To avoid the backflow of condensation into the
fan in ceiling installation it is good practice to fit
a CONDENSATION TRAP to the outlet duct of
the fan.
Ensure free running of the fan impeller and that
flexible duct connections are not over tightened
to the fan outlet spigot.
To avoid reduced flow, an elbow plenum should
be used for all installations which contain
ending of ducting.
b
ONDENSATION
C
TRAP
Front Cover Removal
he front cover of the iCON SELV and
T
iCON eco S fan has a bayonet type fitting.
To remove, undo the retaining screw at
the bottom edge of the cover using a
screwdriver, then rotate the cover a few
UNDO THE RETAINING
SCREW AT THE BOTTOM
EDGE OF COVER USING A
SCREWDRIVER.
degrees anticlockwise and remove. To
refit, reverse the above procedure.
Recessing iCON SELV/iCON eco S Fans in Wall
The iCON 15 SELV and iCON eco15S requires a 110mm diameter hole through the wall
lined with a 100mm id (internal diameter) duct.
The iCON 30 SELV and iCON eco30S requires a 110mm diameter hole through the wall,
counter bored 160mm diameter to a depth of 75mm. The 110mm hole should be lined with
a 100mm id duct.
Surface Mounting iCON SELV/iCON eco S Fans on Wall
When surface mounting the iCON 30 SELV and iCON eco30S the supplied mounting skirt
should be used.
The iCON 30 SELV and iCON eco30S requires a 110mm diameter hole through the wall
lined with a 100mm id duct.
Recessing iCON SELV/iCON eco S Fans in Ceiling
POSSIBLE CABLE
ROUTING
CEILING
When recessing fans in the ceiling, a plywood support (min 18mm thick) should be
mounted between the ceiling joists. Fans should not be fitted to unsupported plaster board.
The iCON 15 SELV and iCON eco15S requires a 110mm diameter hole through the
ceiling. The fan to be fixed, with the screws provided, through the plaster board into the
support.
The iCON 30 SELV and iCON eco30S requires a 160mm diameter hole through the
ceiling. The fan to be fixed, with the screws provided, through the plaster board into the
support.
DUCT
JOIST
PLYWOOD
Surface Mounting iCON SELV/iCON eco S Fans on Ceiling
POSSIBLE CABLE
ROUTING
CEILING
When surface mounting the iCON 30 SELV/iCON eco30S the mounting skirt should be
used.
The iCON 30 SELV/iCON eco30S requires a 110mm diameter hole through the ceiling.
The surface mounted skirt to be fixed, with the screws provided, through the plaster board
into the support. The fan is then fitted into the skirt.
MOUNTING
SKIRT
DUCT
JOIST
PLYWOOD
Electrical Installation
All electrical installation to be carried out by an approved electrician in accordance with
Part “P” U.K. Building Regulations and to the latest IEEE standards, or the appropriate
regulations in the country of installation.
The iCON SELV/iCON eco S transformer unit requires a 230V 50Hz supply, it is double
insulated so does not require an earth.
The iCON SELV/iCON eco S fan requires a 12V dc supply via the transformer.
iCON SELV/iCON eco S wiring with no control module fitted.
3 AMP
SWITCHED FUSE
TRANSFORMER / POWER
SUPPLY
Page 6 of 8 Page 7 of 8 Page 8 of 8Page 5 of 8
Optional Modules for iCON SELV/iCON eco S
iCON SELV/iCON eco S control module with external switching.
3 AMP
SWITCHED FUSE
TRANSFORMER / POWER
SUPPLY
iCON SELV/iCON eco S control module with no external switching.
3 AMP
SWITCHED FUSE
TRANSFORMER / POWER
SUPPLY
Refer to instructions supplied with (optional) modules for further information.
Maintenance
SAFETY FIRST: ALWAYS ISOLATE THE FAN UNIT FROM THE POWER SUPPLY
BEFORE REMOVING THE COVER.
Warranty only covers the fan, not the reinstallation of this if required.
When installed according to these instructions the iCON SELV/iCON eco S fans are
completely safe.
The materials used do not constitute a hazard. The module covers are made of a flame
retardant material.
Cleaning
• The external housing of the fan can be wiped with a damp cloth. Do not use household
cleaners containing abrasives.
• Cleaning of the internal parts such as the impeller should be carried out using a soft
brush.
Note: Always ensure that the fan unit is isolated from the power supply before inserting the
brush into the impeller duct.
• Never clean any parts of the fan assembly by immersing in water or using a dishwasher.
Warranty
Applicable to units installed and used in the United Kingdom. Airflow guarantees the iCON
SELV/iCON eco S fan units and SELV/eco S modules for 3 YEARS from date of purchase
against faulty material or workmanship. Warranty only covers the fan, not the reinstallation
of this if required.
In the event of any defective parts being found, Airflow Developments Ltd reserve the right
to repair or at our discretion replace without charge provided that the unit:
1. Has been installed and used in accordance with the fitting and wiring instructions
supplied with each unit.
2. Has not been connected to an unsuitable electrical supply.
3. Has not been subjected to misuse, neglect or damage.
4. Has not been modified or repaired by any person not authorised by Airflow
Developments Ltd
5. Has been installed in accordance with latest Building Regulations and IEEE wiring
regulations.
Airflow Developments shall not be liable for any loss, injury or other consequential
damage, in the event of a failure of the equipment or arising from, or in connection with,
the equipment excepting only that nothing in this condition shall be construed as to
exclude or restrict liability for negligence.
This warranty does not in any way affect any statutory or other consumer rights.
Manufacturer
AIRFLOW DEVELOPMENTS Ltd
Aidelle House, Lancaster Road
Cressex Business Park
High Wycombe
Buckinghamshire
HP12 3QP
United Kingdom
Tel: +44 (0) 1494 525252
Fax: +44 (0) 1494 461073
Email: info@airflow.com
Web: airflow.com
AIRFLOW DEVELOPMENTS Limited reserve the right in the interest of continuous development to alter any or all specifications without prior notice.
Czexh Republic
AIRFLOW LUFTTECHNIK GmbH
o.s. Praha
Hostýnská 520
108 00 Praha 10
Malešice
Czech Republic
Tel: +42 (0) 2 7477 2230
Fax: +42 (0) 2 7477 2370
Email: info@airflow.cz
Web: airflow.cz
Germany
AIRFLOW LUFTTECHNIK GmbH
Postfach 1208
D-53349 Rheinbach
Germany
Tel: +49 (0) 222 69205 0
Fax: +49 (0) 222 69205 11
Email: info@airflow.de
Web: airflow.de