Domestic AC Fans – 230V
Installation and Operating Guide
230V AC Base Models:
iCON15 – 72683501
iCON15C – 72591501
iCON30 – 72591601
iCON60 – 72591701

Installation, Maintenance and Use
iCON Domestic Fans are available in 3 model sizes and can be fitted to a wall or ceiling. Each
fan requires a suitable size hole through the wall or ceiling which connects into a duct
venting to the outside. The external opening should be covered by a suitable external grill,
available separately from Airflow Developments Ltd.
Airflow iCON Model Options:
72683501 - 15 -100mm Axial Fan with maximum capacity of 19 l/sec.
72591501 - 15C -100mm Axial Fan with maximum capacity of 19 l/sec.
72591601 - 30 -100mm Mixed Flow Fan with maximum capacity of 32 l/sec
72591701 - 60 -150mm Mixed Flow Fan with maximum capacity of 72 l/sec
The iCON range can be used as a simple extract fan operated by a remote switch, or can be
fitted with an internal control module, available separately to give a range of control options
including timer, humidity, motion sensor, pull cord, trickle speed or combinations of these
functions. Optional modules are available separately and can be fitted at the time of
installation or retrofitted.
The iCON Fan has an IP X4 rating housing and is suitable for mounting in Zone 2 in
bathrooms, toilets, kitchens, utility rooms and inside shower cubicles as defined in Section
701 BS7161:2008 (IEEE wiring standards, 17th Edition ). They also comply with the latest
Building Regulations.
Do not place the ventilator near direct heat sources, e.g. radiant heaters, or where
temperatures can exceed 40°C (104°F).
The Fan requires a 230V 50Hz single phase supply. Class II equipment. BS EN 60417. An
external 3A fuse is required for each fan unit. Note: Switches for fans should be selected and
sited in accordance with BS7161:2008
Page 2 of 8

All electrical installation to be carried out by an approved electrician in accordance with Part
“P” U.K. Building Regulations and to the latest IEEE standards, or the appropriate regulations
in the country of installation.
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety.”
“Children should be supervised to ensure that they do not play with the appliance”
“The fan is to be installed so that the blades are more than 2,1 m above the floor( for fans
intended to be mounted at the high level)”
ALWAYS ISOLATE THE POWER SUPPLY UNIT AND FAN UNIT FROM THE POWER SUPPLY
BEFORE REMOVING THE COVER.
Mechanical Installation
iCON Domestic Fan can be recessed in a wall or
ceiling. A mounting skirt is provided for surface
mounting the iCON 30 and iCON 60.
To avoid the backflow of condensation into the fan
in a ceiling installation it is good practice to fit a
CONDENSATION TRAP to the outlet duct of the fan.
Ensure free running of the fan impeller and that
flexible duct connections are not over tightened to
the fan outlet spigot.
Airflow recommends that rigid ducting is used
instead of flexible ducting, this will ensure
maximum performance
Front Cover Removal
SCREW AT THE BOTTOM
EDGE OF COVER USING A
Page 3 of 8
The front cover fan has a bayonet type
fitting. To remove, undo the retaining
screw at the bottom edge of the cover
using a screwdriver, then rotate the
cover a few degrees anticlockwise and
remove. To refit, reverse the above
procedure.