Airflow 72683501, 72591701, 72591601 Installation Instructions

Domestic AC Fans – 230V
Installation and Operating Guide
230V AC Base Models:
iCON15C – 72591501
iCON30 – 72591601 iCON60 – 72591701
iCON Domestic Fan – 230V
Installation, Maintenance and Use
iCON Domestic Fans are available in 3 model sizes and can be fitted to a wall or ceiling. Each fan requires a suitable size hole through the wall or ceiling which connects into a duct venting to the outside. The external opening should be covered by a suitable external grill, available separately from Airflow Developments Ltd. Airflow iCON Model Options: 72683501 - 15 -100mm Axial Fan with maximum capacity of 19 l/sec. 72591501 - 15C -100mm Axial Fan with maximum capacity of 19 l/sec. 72591601 - 30 -100mm Mixed Flow Fan with maximum capacity of 32 l/sec 72591701 - 60 -150mm Mixed Flow Fan with maximum capacity of 72 l/sec
The iCON range can be used as a simple extract fan operated by a remote switch, or can be fitted with an internal control module, available separately to give a range of control options including timer, humidity, motion sensor, pull cord, trickle speed or combinations of these functions. Optional modules are available separately and can be fitted at the time of installation or retrofitted.
The iCON Fan has an IP X4 rating housing and is suitable for mounting in Zone 2 in bathrooms, toilets, kitchens, utility rooms and inside shower cubicles as defined in Section 701 BS7161:2008 (IEEE wiring standards, 17th Edition ). They also comply with the latest Building Regulations.
Do not place the ventilator near direct heat sources, e.g. radiant heaters, or where temperatures can exceed 40°C (104°F).
The Fan requires a 230V 50Hz single phase supply. Class II equipment. BS EN 60417. An external 3A fuse is required for each fan unit. Note: Switches for fans should be selected and sited in accordance with BS7161:2008
Page 2 of 8
UNDO THE RETAINING
SCREWDRIVER.
CONDENSATION TRAP
All electrical installation to be carried out by an approved electrician in accordance with Part “P” U.K. Building Regulations and to the latest IEEE standards, or the appropriate regulations in the country of installation.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for
their safety.” “Children should be supervised to ensure that they do not play with the appliance” “The fan is to be installed so that the blades are more than 2,1 m above the floor( for fans intended to be mounted at the high level)”
ALWAYS ISOLATE THE POWER SUPPLY UNIT AND FAN UNIT FROM THE POWER SUPPLY BEFORE REMOVING THE COVER.
Mechanical Installation
iCON Domestic Fan can be recessed in a wall or ceiling. A mounting skirt is provided for surface mounting the iCON 30 and iCON 60.
To avoid the backflow of condensation into the fan in a ceiling installation it is good practice to fit a CONDENSATION TRAP to the outlet duct of the fan.
Ensure free running of the fan impeller and that flexible duct connections are not over tightened to the fan outlet spigot.
Airflow recommends that rigid ducting is used instead of flexible ducting, this will ensure maximum performance
Front Cover Removal
SCREW AT THE BOTTOM EDGE OF COVER USING A
Page 3 of 8
The front cover fan has a bayonet type fitting. To remove, undo the retaining screw at the bottom edge of the cover using a screwdriver, then rotate the cover a few degrees anticlockwise and remove. To refit, reverse the above procedure.