Aiphone KB-DAR-M INSTALLATION INSTRUCTIONS

Special Order Products
KB-DAR-M
KB-DAR Modified for Motion Detector Interface
- INSTRUCTIONS -
The KB-DAR-M allows any standard motion detector or activation device with a normally open contact to be interfaced with the KB-3MRD Video System. When the motion detector is tripped, the camera will turn on and a chime will be heard at the inside monitor station(s), indicating that there is some activity near the door station location.
WIRING DIAGRAM:
Motion Detector*
Motion Detectors with N/O Contacts:
Detection Systems DS720I Pulnix 6612 Intellisense 8140S Ademco 1998PI Sentrol AP750
Installation Guidelines:
1. The motion detector must provide a normally open momentary contact. A Photelectric beam, pressure pad, or remote call button can also be used to activate the video door station.
2. The KB-DAR-M works with the KB system only. Standard KB-DAR's can be used in the same system if they are not interfaced with a remote activation device.
* Or any signaling device that provides a normally open momentary dry closure.
KB-DAR-M
A1
White White
A2
Door Strike
Aiphone 871802 wire
KB-DAR
A1 A2
Aiphone 871802 wire
PT-1210N
(AC Transformer)
+
-
PS-24E
KB-3MRD
1A1 1A2
2A1 2A2
B1 B2
Yel
Org
+
-
871802
KB-3HRD
1A1 1A2
+
-
Note:
Only information concerning the use of the KB-DAR-M is shown here. For complete system installation, please refer to the instruction manuals included with the video system.
Aiphone Communication Systems 1700 130th Ave. N.E. Bellevue, WA 98005 (425) 455-0510 FAX (425) 455-0071
TOLL FREE TECHNICAL SUPPORT:
TOLL FREE FAX LINE: