PRECAUTIONS
General Prohibitions Prohibition to Dismantle the Unit Prohibition on Subjecting the Unit to Water General Precautions
WARNING
(Negligence could result in death or serious injury.)
EnglishFrançais
1. High voltage is present internally. Do not open the case. Electric shock could result.
2. Do not dismantle or alter the unit. Fire or electric shock could result.
3. Do not connect any non-specified power source to the +, - terminals. Also, do not
install two power supplies in parallel to a single input. Fire or damage to the unit
could result.
4. Keep the unit away from water or any other liquid. Fire or electric shock could result.
5. Do not put any metal or flammable material into the unit through the openings. Fire
or electric shock could result.
6. Do not use power supply with a voltage other than specified. Fire or electric shock
could result.
7. Do not connect any terminal on the unit to an AC power line. Fire or electric shock
could result.
CAUTION
(Negligence could result in injury to people or damage to property.)
1. Do not install or make any wire terminations while power supply is plugged in. It
can cause electrical shock or damage to the unit.
2. Before turning on power, make sure wires are not crossed or shorted. If not, fire or
electric shock could result.
3. When mounting the unit on a wall, install the unit in a convenient location, but not
Nederlands
where it could be jarred or bumped. Injury could result.
4. For power supply, use Aiphone power supply model or model specified for use
with system. If non-specified product is used, fire or malfunction could result.
5. Do not install the unit in any of the following locations. Fire, electric shock, or unit
trouble could result.
* Places under direct sunlight or places near heating equipment that varies in
temperature.
* Places subject to dust, oil, chemicals, etc.
* Places subject to moisture and humidity extremes, such as bathrooms, cellars,
greenhouses, etc.
* Places where the temperature is quite low, such as
front of an air conditioner.
* Places subject to steam or smoke (near heating or cooking surfaces).
* Where noise generating devices such as dimmer switches or inverter electrical
appliances are close by.
* Do not install the unit in locations subject to frequent vibration or impact.
6. Do not put anything on the unit or cover the unit with cloth, etc. Fire or unit trouble
could result.
7. Do not press on the LCD or subject it to a high impact. The LCD glass could be
punctured and result in an injury.
8. If the LCD is punctured, do not allow skin contact with the liquid crystal inside.
Inflammation could result.
* If liquid crystal is ingested, immediately gargle with water and seek medical
attention.
* If contact with the eyes or skin occurs, clean with pure water for at least 15 minutes
and seek medical attention.
inside a refrigerated area or in
1. Keep the unit more than 1 m away from radio or TV set.
General Precautions
2. This
unit is for indoor use only. Do not use outdoors.
3. In areas where broadcasting station antennas are close by, the intercom system may be
affected by radio frequency interference.
4. As to other manufacturer's devices (such as sensor, detectors, door releases) used
with this system, comply with the Specifications and Warranty conditions that the
manufacturers or venders present.
5. Keep the intercom
and malfunction could result.
6. If the unit is down or does not operate properly, unplug the power supply or turn off
the JK-1MED and JK-1HD (JK-1SD) POWER switches.
7. The unit is for wall-mount use only. For desktop applications, use desk stand.
8. When wall-mounted, the top of the unit may darken. This does not indicate a
malfunction
9. The unit case may become warm with use, but this is not a unit malfunction.
10. If a cellular phone is used close by, the unit may malfunction.
11. The LCD panel is manufactured with very high precision techniques. Small portions
of the panel may fail to light up or some portions may be constantly lit, but this does
not indicate a unit malfunction. Please be aware of this in advance.
12. Refrain
13. At night, due to reduced lighting on the object, the monitor sees more noise and the
face becomes more difficult to see, but this is not malfunction.
14. Talk within 50 cm (20") or less from the unit. If you stand too far away, it may be
difficult for the other person to hear the communication.
15. If there are loud noises around the unit (such
sound may break up and be difficult to hear.
16. During communication, if you speak before the other person has finished talking, your
voice may not come through clearly. Communication will proceed smoothly if you
wait until the other person has finished before speaking.
17. At a gate or porch illuminated by a fluorescent lamp, the picture may vary, but this is
not a malfunction.
18. When outside temperature lowers sharply after rainfall, etc., the inside of the camera
may fog up slightly, causing a blurry picture, but this is not a malfunction. Normal
operation will be restored when moisture evaporates.
19. Due to the environmental sound around the unit, it may hinder smooth communication,
but this is not a malfunction.
20. The outline of video images disp
the actual person(s) or background, but this is not a malfunction.
21. If the screen of a video door station freezes during wintertime, the picture may become
difficult to see or the CALL button may not move, but this is not a malfunction.
22. Aiphone assumes no responsibility for corruption of saved information (such as
changes to or deletion of sa
23. This unit is not compatible with JA, JF, KB, and KC series units.
24. Warm-color lighting shining on the door station may change the tint of the picture on
the monitor.
wires at least 30 cm (12") away from AC 100-240 V lines. Noise
.
from using the color monitor station in sunlit areas.
as music playing or children crying), the
layed by video door station may differ from that of
ved information). Please be aware of this in advance.
1
PACKAGE CONTENTS
JK-1MED Mounting screws x 2 Wood mounting screws x 2
Option connector Installation & Operation manual
- 2 -
2
+ 5 cm
(2")
+ 5 cm
(2")
JK-1MED
2
3
+ 15 cm
(6")
JK-1HD
JK-1SD
JK-1MED
JK-DA
JK-DV
JK-DVF
2 4
PS18
PS-1820
PS-1810DIN
PS-1820DIN
A
B C
IER-2
JK-1MED JK-1HD/JK-1SD
120 120
+
-
A1
A2
B1
B2
L
L
S
S
+
-
SW
SW
B1
B2
INSTALLATION
2-1 Mounting locations
Install the master monitor station in a place
1
where the screen is not exposed to direct
sunlight.
The master monitor station has switches on
2
both sides. Allow at least 5 cm (2") of open
space on either side.
2-2 Wiring method, wiring distance
Wire the units from station-to-station (daisy-chained).
Allow at least 15 cm (6") of vertical open
3
space from the center of the mounting
bracket in order to mount the master
monitor station.
English Français Nederlands
2-3 Cable
Use PVC jacket with PE (polyethylene) insulated cable
1
Never use individual conductors, twisted pair cable or coaxial cable.
2
Ø
0,65 mm 22 AWGØ 1,0 mm 18 AWG
A 50 m 165' 100 m 330'
B 5 m 16' 10 m 33'
C 75 m 245' 150 m 490'
When using a cable with unused conductors, terminate both ends of
3
the unused pair(s) with a 120 Ω resistor.
- 3 -
3
JK-1MED
OP
EL-12S
OP
IER-2
1
E
A1 A2
JK-DVFJK-DV
JK-DA
DOOR
PS-1820
PS-1810DIN/
PS-1820DIN
230V AC
N
L
18V DC 1A (PS-1810DIN)
18V DC 2A (PS-1820DIN)
IN 230V~ 50/60Hz
NL
1A
-
+
+
100V - 240V -
50/60 Hz
18V DC
2 A
2
NP
DC 18 V
-
+
2
P
2
NP
2
NP
OPTION
CONNECTOR
2
NP
2
P
WIRING
Insert wires securely into each terminal as shown.
EnglishFrançais
Nederlands
Optional call extension speaker
IER-2
Presence of sound from IER-2
Chime tone from door station (8-1) ○
Alarm sound during external sensor
input (8-15)
Audio during instant voice call (8-1) −
Chime tone during room-to-room
communication (8-4)
Door release
Video door station
Item Sound
○
−
Master monitor station
Power supply
NP:
Non-polarized
P:
Pol
arized
An EL-12S (AC 12 V 0.125 A, DC 12 V 0.2 A) or equivalent part and a separate AC transformer are required.
Run separate cables for audio/video and door release.
Door release contact: AC/DC 24 V, 0.5 A (Minimum Contact : 100 mV DC, 0.1 mA)
(N/O dry closure contact L, L).
AC transformer
- 4 -
JK-1HD
-
+
KE
KS
SW
SW
V -
V +
[1]
[2]
[3]
(BR)
(RD)
(OR)
(YE)
(GR)
(BL)
JK-1SD
OPTION
CONNECTOR
2
NP
2
P
2
P
PS18 PS18
JK-1MED JK-1HD
-
+
BR: Brown
RD: Red
OR: Orange
YE: Yellow
GR: Green
BL: Blue
A1
A2
+
-
B1
B2
+
-
B1
B2
A1
A2
+
-
B1
B2
A1
A2
AB
C
JK-1MEDJKW-BA
JK-DA
JK-DV
JK-DVF
PS18
2
NP
2
NP
2
P
2
NP
2
P
2
P
JK-1HD
JK-1SD
D
Sub master
monitor station
(To optional units)
When the JK-1HD is connected, split
power between the master station and
the sub master station if radio signals are
picked up during communication.
(To optional units)
Audio only sub master station
English Français Nederlands
Option connector: Control external devices connected with the option connector.
[3] External sensor input settings are required.
External sensor input specifications
To prevent shorts, be sure to cut unused lead wires at the bottom and
insulate the ends.
[1] Video signal output: Video can be output to DVR, etc.
(NTSC, 1 Vp-p/75 Ω ) Wiring distance: 3 m
NOTES: When a video signal is output, the monitor station may produce
a buzzing sound depending on the installation environment.
A video signal is only output during calling from a door station to the JK1MED/during communication between a door station and the JK-1MED/during
monitoring from the JK-1MED (screen playing recorded pictures is not output).
Input method
Detection
confirmation time
Contact resistance
Terminal short
current
Voltage between
terminals
N/O dry closure contact
External sensor input
(start signal only detection method)
100 mS or more
During N/O dry closure: Less than 700 Ω
During N/C dry closure: At least 3 k Ω
Less than 10 mA
Less than DC 20 V
(when open between terminals)
[2] Options output
(AC/DC 24 V, 1.6 A N/O dry closure contact)
(Minimum Contact : 100 mV DC, 0.1 mA)
Optional long distance adaptor JKW-BA
Use the long distance adaptor JKW-BA within the distance ranges shown in the table when the wiring distance between the door station and the furthest inside unit is
longer than the distance in 2-2 on p. 3.
NP:
Ø 0.65 mm 22 AWG Ø 1.0 mm 18 AWG
A 100 m 330' 200 m 650'
B 50 m 165' 100 m 330'
C 50 m 165' 100 m 330'
D 5 m 16' 10 m 33'
Non-polarized
P:
Polarized
- 5 -
4
PS-1810DIN/
PS-1820DIN
PS-1820
MOUNTING
Back wiring
Mounting screws x 2
EnglishFrançais
Mounting bracket
1. Press RELEASE button
(to insert or remove the wire).
2. Insert the cable into the terminal.
Surface wiring
Nederlands
* When a 1-gang box is not mounted, the cable can be routed as surface wiring to the top or
bottom of the unit. Cut a cable inlet on the upper part of the unit to allow passage of the
wiring into the unit.
* To pass the cable through the back of the
unit, cut out the cable inlet.
1-gang box
83,5 mm
(3-5/16")
Mounting bracket
Din rail
1-gang box
Wood
mounting
screws x 2
5
Record LED (red)
RECORD button
POWER switch
NAMES
Play LED (red)
PLAY button
Speaker
Mounting bracket
83,5 mm
(3-5/16")
Color LCD video monitor
Microphone
Door release LED (red)
DOOR RELEASE button
Menu LED (red)
MENU button
PAN/TILT button
ZOOM/WIDE button
ADJUST button
CALL button
Option button (*)
Transmit LED (red)
TALK button
OFF button
MONITOR button
- 6 -
83,5 mm
(3-5/16")
Screen brightness control
(0 〜 10)
Receive volume control
(0 〜 10)
Chime tone volume
(0 〜 10)
(*) The option butto
units such as turning lighting on and off and
activation of added door releases.
n controls connected option