NAMES & FUNCTIONS
SAFETY CAUTIONS
■ Precaution notation
This installation manual uses various symbols for the sake of safe usage.
The results that can occur from ignoring these indications and handling this equipment incorrectly are categorized as follows.
Icon display example
^ symbol indicates a prohibition. The specific content
prohibited is drawn in or near the figure. (For the figure
on the left, disassembly is prohibited.)
This indicates that ignoring the contents of
\AfADMIMP
VVAnIXI 1
Do not disassemble
or alter.
Electric shock caution
the warning and handling the equipment
l\lvj
incorrectly can result in death or severe
injury.
Do not disassemble or alter this
equipment. Doing so would be
dangerous. Fire or electric shock
could result.
Do not touch the main unit with
damp or wet hands. Electric shock
and equipment damage could
result. When existing chime wiring
is used, it is possible that it contains
AC power. This can cause
equipment damage and electric
shock. Have the installation done
by an electrical contractor, low
voltage contractor, or qualified
personnel.
A
О
/
j \
■ '
and/or damage to equipment.
Use in areas with water
or high humidity is
prohibited.
Install securely.
Q symbol indicates behavior that is mandatory and gives
directions.
This indicates that ignoring the contents of
r* Л
1
IT
1
M
ими MUIN incorreetly can result in personed injury
warning and handling the equipment
This product is weather resistant,
but do not install it in a bathing
room or other place with extremely
high humidity, any place where
water might get into it, or in water. 11
Do not spray water directly on this
equipment, for example with a hose.
Fire, electric shock, and equipment
damage could result.
Install securely to a solid location
so that the equipment can not drop M
from its own weight. Equipment ww
falling could result in injury.
TROUBLESHOOTING
•No power is being supphed from the
master station.
• The wiring is incorrect or a line is open or
©The unit does
not operate.
©The system does
not detect
people.
^
©Sound cannot be
heard from the
unit.
shorted.
• The unit was wired to the master station
with power supplied.
• The master station select switch setting is
reversed.
• The detection area is not eorrectly set. • Check the detection area and camera angle of view area emd install so that
• People are passing nearly directly under
the sensor camera.
• People are coming directly at the camera.
• The detection area is cut off by glass.
•With the external sensor input function in
"AND mode", people are only detected
by the main sensor or by the external
sensor but not by both.
• The internal sensor switch is "OFF". • Switch "ON" the internal sensor switch.
• The speaker select switch is "OFF". • Switch "ON" the speaker select switch.
•The master station select switch is "B".
• Wire the master station eorreetly to supply power.
• Wire correctly. (See "MOUNTING AND CONNECTION".)
• Keep the power OFF until the wiring is completed.
• Set "A" and "B" correctly. (See "SETTINGS".)
people are detected. (See "ADJUSTMENTS".)
• Adjust the up/down angle to point down so that they are detected.
• This is not a breakdownf. Because of the characteristics of a heat ray type
sensor, it may have difficulty detecting people coming directly at the camera.
As much as possible, install in such a way that people cut across the detection
area. (See "ADJUSTMENTS".)
• Connect an external sensor in "OR mode" so that people cut across the
detection area. (See "SETTINGS".)
• This is not a breakdown. A heat ray type sensor cannot detect objects through
glass. Install in a place where the detection area is not cut off by the glass.
(See "MOUNTING AND CONNECTION".)
• This is not a breakdown. Set the detection area for each sensor so that people
are detected by both sensors. (See "SETTINGS".)
• Switch the master station select switch to "A". (Sound cannot be heard from
the unit when the master station is JA-2MECD or JA-2MCD.)
I
Notice
This product detects a person, provides notice, and shoots images. It is not an anti-theft device.
Aiphone does not bear responsibility for any damage incurred in the event of theft or other such incident.
CAUTION
— Installation precautions/iy-
■ For correct installation
Do not install in the following places.
SPECIFICATIONS
Model No.
Power Supplied from the master station
Operating temperature range -10-+50 °C
Storage temperature range -20 - +60 °C
Operating humidity range 85% (max.)
Picture eiement
Camera angie of view (horizontai x verticai)71.5° X 53.4° (f=3.8)
Minimum iilumination 1.0 lux
Sensor operation display iight Lights up green when the sensor detects something (Can be switched OFF with the select switch)
Sensor detection method
Sensor detection area Max. 5 meters, approx. 70°
Sensor detection speed
Sensor sensitivity switching Switchable among three levels H (high), M (medium), and L (low)
Sensor startup time Approx. 30 sec. after power comes on
External sensor input
Internal sensor switching The internal body detection sensor can be controlled to be "ON" or "OFF".
Internal speaker
Internal mic. The mic. sensitivity can be adjusted with the mic. sensitivity volume.
Master station switch Switchable according to the master station version.
Camera
Arrgle adjustment range
Sensor
Installation places
Protective structure Weather-resistant
Weight Approx. 400 g
Dimensions (mm)
1/3-inch color CCD
Heat ray type
0.3 - 1.5 m/sec.
An external sensor can be connected and operated in either an "AND" or "OR" configuration with this unit.
The internal speaker can be controlled to be "ON" or "OFF" with the speaker select switch.
+50° left/right, -20° to -55° up/down (The horizontal direction is 0°.)
(The left/right and up/down angles can both be changed in increments of 5°.)
±50° left/right, -20° to -55° up/down (The horizontal direction is 0°.)
(The left/right angle can be changed in increments of 10° and the up/down angle in increments of 5°.)
Indoors/Outdoors
102 (W)x 182 (H)x94 (D)
JDW-C
I
Any place hlown on by a fan, the
outdoor unit of an air-conditioner,
or any other place subject to
sudden temperature changes.
On any surface that moves or is
affected by wind.
KJse two conductor wire from the JDW-C to the master station. Do not use coaxial cable.
►When using two cameras, always use one two conductor wire for each camera. If you connect two cameras with one multi
conductor wire, the cameras may not operate correctly.
>If the wiring is routed together with high voltage AC wiring, other power wiring, wiring for electrical lights, and telephone
lines, this can disrupt the picture and sound quality and cause malfunction. Either use separate conduits or run wires in
separate paths from each other.
> When existing wiring is used, for some type of wiring, this system may not operate correctly. Changing the wiring restores
normal operation.
Any place where sunlight gets in
the angle of view of the sensor
camera directly or indirectly.
i
§
Any place too close to a source
of electrical noise, for example a
broadcasting station or wireless
station of гту kind.
Connection precautions/^-
\V\ ^
Ì1
Any place too close to
fluorescent lamps or directly
facing powerful illumination.
Any place where the detection
area or camera angle of view will
be blocked off.
In or near any place subject to
steam or oil from an exhaust
duct.
©Sound cannot be
heard from the
master station.
©There is
howUng.
©The sensor is
detecting but
the detected
objects are not
displayed on the
screen.
©The picture is
dark, blurred, or
not displayed at
aU.
©There are white
lines on the
screen.
©The screen is
flickering.
• The wiring is incorrect or a line is open or
shorted.
• The mic. sensitivity volume is at the
"Low" side.
• The sensor camera is installed too close
to the master station.
• There is a dog or cat or other small
animal in the detection area.
• There is something that moves in the
detection area, for example a flag or tree
blowing in the wind, or there are sudden
temperature changes.
• The external sensor area does not match
the camera angle of view.
• The wiring is incorrect or a line is open or
shorted.
• The camera window is dirty. • Clean the lens with lens cleaner or with a clean, soft, damp cloth.
• The outside temperature dropped
suddenly and the camera window has
fogged up.
• There is a bright fight source in the
camera angle of view.
• There is a fluorescent lamp nearby.
• Wire correctly. (See "MOUNTING AND CONNECTION".)
• Turn the mic. sensitivity volume to the "High" side. (See "SETTINGS".)
• This is not a breakdown. Install the sensor camera farther from the master
station or turn the mic. sensitivity volume to the "Low" side until there is no
howling.
• Set the sensor sensitivity switch to "L (Low)". (See "SETTINGS".)
• Recommend to connect an external sensor and use it in "AND mode". (See
"SETTINGS".)
• Set the sensor sensitivity switch to "L (Low)". (See "SETTINGS".)
• Either move the moving object or the object causing the sudden temperature
changes outside the detection area or change the area setting. (See
"SETTINGS".)
• Align the external sensor area emd the emera angle of view. (See
"ADJUSTMENTS" and "SETTINGS".)
• Check the wiring and wire correctly. (See "MOUNTING AND
CONNECTION".)
• When the temperatures inside and outside the product even out, the camera
window returns to normal.
•Either remove the fight source, adjust the angle so that the fight does not come
into the angle of view, or change the mounting location of the main unit. (See
"ADJUSTMENTS".)
• This is not a breakdown. Block out the fight from the fluorescent lamp.
WARRANTY
Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of
two years after delivery to the ultimate user and will repair free of charge or replace at no charge, should it become defective upon
which examination shall disclose to be defective and under warranty. Aiphone reserves unto itself the sole right to make the final
decision whether there is a defect in materials and/or workmanship; and whether or not the product is within the warranty. This
warranty shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, or to use in violation of
instructions furnished, nor extended to units which have been repaired or altered outside of the factory. This warranty does not
cover batteries or damage caused by batteries used in connection with the unit. This warranty covers bench repairs only, and any
repairs must be made at the shop or place designated in writing by Aiphone. Aiphone will not be responsible for any costs incurred
involving on site service calls.
®AIPHONE‘
AlPHONE CO., LTD., NAGOYA, JAPAN
AlPHONE CORPORATION, BELLEVUE, WA, USA
AlPHONE S.A., WISSOUS, CEDEX, FRANCE
MOUNTING AND CONNECTION
@
Remove the screw cover and loosen the cover mounting screw.
Pull the top of the two sides of the main unit cover toward you
and remove the main unit eover.
pA CAUTION--------------------------------------------
Do not pull the cover out more than is necessary.
It may result disconnection at cable.
Loosen the lock screw, pull the main unit bottom toward
you, and remove the main unit from the mounting plate.
♦ Wiring
Acaution----------------------------------
Always cut off the power switch before
wiring. Do not install with wet or damp
hands .Electric shock could result.
IWpI
External
sensor
^
--
I---1
Acaution----------------
Before turning on the
power, make sure wires
are not wrongly
connected or shorted.
Fire or electric
shock could result.
__
I—1
SETTINGS
► Speaker switching
Speaker
LED AND/OR
OFF ON
Internal sensor
I Internal sensor switching
Speaker
LED AND/OR
Internal sensor
Make sure the speaker select switch is
always on "OFF" side.
The internal sensor can be switched
ON/OFF by the main unit's internal
sensor select switch.
Use this when the internal sensor is
not necessary, for example when
using an external sensor.
The factory setting is "ON".
ON: The internal sensor
detects people.
OFF: The internal sensor does
not detect people.
B Operation indicator iight (LED) switching
The operation indicator light select switch can switch
the operation indicator lights ON/OFF. The normal
setting is "OFF". Switchmg OFF the operation indicator
light avoids making visitors aware that they are being
photographed by the camera.
The factory setting Is "OFF"
The LED lights up when
a person Is detected. It
lights up for approx. 2
sec. (Used for area
adjustment.)
OFF: The LED does not light
up. (This is the normal
position for use.)
I Sensor sensitivity switching
The sensor sensitivity select switch can switch the
sensitivity with which people are detected among three
levels. Set this switch to match the enviromnent.
The factory setting Is "M"
Sensor
M-
l/
18 This does not change the sensitivity of a sensor cotmected
directly to the external sensor input.
The sensor sensitivity varies with the temperature
and this can cause mistaken detection. Set the
sensitivity according to the season as follows.
A
Summer-> H (High) Spring, Autuum (Medium) Winter-> L (Low)
H (High): This raises the
sensitivity. (Set this If
detection is difficult.
M (Medium): Normally, use this
position.
' L (Low): This lowers the
sensitivity. (Set this If
the system is
frequently triggered by
mistake.)
When mounting on an outside wall with a large gap or on
an uneven surface, such as tiles, fill in the mounting surface
grooves and gaps with caulk.
pA CAUTION--------------------------------------------
If the waterproofing is incomplete, this can cause
equipment breakdown, fire, or electric shock.
Tear the wall sponge at the mounting plate wiring hole
section and pull the wires through from inside the wall.
Mount the mounting plate at the prescribed position.
18 Caulk around the wires before mounting the main unit.
Wire the master station with PE (polyethylene) insulated wire with PVC jacket.
Refer to the table below for wire diameters and permitted wiring distances.
Singie core wire 0 0.65 mm 0 0.9 mm
0 1.2 mm
Distance 50 meters max.100 meters max.100 meters max.
Peel approx. 7 mm of insulation off the ends of wires.
Approx. 7 mm
♦ When surface cable runs are necessary
I Master station switching
Speaker
'led and/or
You can switch the master station
version.
The factory setting Is "B".
B: JA series
Internal sensor
I Externai sensor input function
The external sensor input function coimects a separate sensor to this unit's external sensor input to widen the
detection range and improve the reliabihty of detection performance. For the external sensor unit, connect one
with N.C. type (normally closed) output.
The factory setting Is © set.
© OR mode
When a person enters the detection area of this unit or external sensor, the sensor detects this and their picture
is taken.
Since this mode is triggered by entry to either one of the detection areas, it can widen the detection area.
When not connecting an external sensor, set to this position.
Detection area for this unit®
I Mie. sensitivity
MIc. sensitivity
Low^*^HIgh
18 When connecting an external sensor, install it somewhere that the camera on this unit can photograph
anyone who enters that external sensor's detection area.
18When not connecting an external sensor, use "OR mode".
@ AND mode
If someone is detected by either this unit or the external sensor, then is detected by the other sensor within 30
sec., that person is detected and photographed.
(If someone passes through only one detection area, even if he/she then passes through the other detection area
more than 30 sec. later, he/she is not detected.)
Since the detectors do not detect if a person, a cat, or whatever passes through only one of the detection areas,
this is an effective measure against mistaken detection.
The internal mic. enables the user to hear outside
sounds from the master station. The volume can be
adjusted with the mic. sensitivity volume.
Mic. sensitivity
I WWlj- u
Low^fe^High
The factory setting Is "Medium"
High: Raises the volume.
Low: Lowers the volume.
Connect the necessary wires.
18 See the "Wiring diagram".
After that, fill in the gap at the wiring hole section.
ADJUSTMENTS
©Adjusting the camera direction:
The camera moves 50° to the left and to the right.
(It moves in 5° by a step.)
The camera moves 35° down.
(It moves in 5° by a step.)
©Adjusting the sensor direction:
The sensor moves 50° to the left and to the right.
(It moves in 10° by a step.)
The sensor moves 35° down.
(It moves in 5° by a step.)
ACaution:
Adjust the sensor direction with holding the
plastic knob on the top of the sensor, NOT with
touching the reflector plate or P.C. board of the
sensor. Touching the sensor with wet or damp
hands, could cause malfunction or breakdown.
Mount the unit onto the frame, then tighten down the lock
screws.
Next, adjust the ceimera and sensor.
For details, refer to "ADJUSTMENTS".
©When the camera and
sensor adjustments are
complete, put the main unit
cover on securely from the
front and tighten down the
main unit cover mounting
screws.
Mounting plate
Cut out the knockout at the bottom of the mounting plate and wire the
required wires to the main unit side.
♦Detection area and camera angle of view
Angle
adjustment
range
Camera
angle of view
Camera 50° (5° increments) 35° (5° increments)
Sensor 50° (10° increments) 35° (5° increments)
Horizontal angle of view Vertical angle of view
71.5° 53.4°
Left/right
Speaker
led and/or
Internal sensor
: The person is detected and photographed.
: The person is detected and photographed.
Plain diagram
(0° left-right swing)
Up/down
czz Sensor detection area
External sensor
detection area(g)
Side diagram
(up/down swing 0°)
CZ2 Sensor detection area
Side diagram
(downward swing 25°)
czz Sensor detection area
External sensor
Speaker
LED AND/OR
External sensor
Internal sensor
(a) and ® : The person Is detected and photographed,
only (i), or only ® : Does not detect.
Detection area for
♦installation precautions
Figure A
External sensor
detection area (E
Sometimes a person
approaching the detection
area from directly in front
of the camera is difficult
to detect. (Figure A)
Mount so that persons
cut across the detection
area. (Figure B)