Aiphone GH User Manual

- 1 -
1105 A
GH SERIES
Apartment Intercom System
INSTALLATION &OPERATION MANUAL
- 2 -
General Prohibitions
General Precautions
Prohibition to Dismantle the Unit
WARNING
(Negligence could result in death or serious injury to people)
1. The unit must be installed and wired by a qualified technician.
2. Do not dismantle or alter the unit. Fire or electric shock could result.
3. Do not connect any non-specified power source to the +, - terminals, and do not install two power supplies in parallel to a single input. Fire, damage to the unit, or system malfunction could result.
4. Keep the unit away from water or any other liquid. Fire or electric shock could result.
5. Do not plug or unplug with wet hands. Electric shock could result.
6. Do not put any metal or paper into the unit through the openings. Fire or electric shock could result.
7. Do not put high pressure on the video-monitor surface. If fractured, injury could result.
8. High voltage is present internally. Do not open the case. Electric shock could result.
CAUTION
(Negligence could result in injury to people or damage to property)
1. Make sure wires are connected properly before plugging the power supply into an electrical outlet.
2. Do not manually hold down hook switch while testing and verifying chime or call tone volume. The chime tone is very loud in earpiece,and could cause hearing damage.
3. Do not install or make any wire terminations while power supply is plugged in. It can cause electrical shock or damage to the unit.
4. Do not install the unit in a location subject to constant vibration or impact. If dropped, injury or unit damage could result.
5. When mounting the unit on wall, install the unit in a convenient location, but not where it could be jarred or bumped. Injury could result.
6. Do not alter or change wall-mounting of the unit. If dropped, it can cause injury.
7. Before turning on power, make sure wires are not crossed or shorted. Fire or electric shock could result.
8. If LCD is punctured, do not allow contact with the liquid crystal inside. Inflammation could result. If necessary, gargle your mouth and clean your eyes or skin with clear water for at least 15 minutes, and consult your doctor.
9. When cleaning outer surface with high-pressure water, be sure that the entrance station will not be subjected to direct water pressure. Damage to the unit could result.
10. To avoid system malfunction, do not install the unit in places;
1. high or extreme cold temperature,
2. subject to moisture or humidity extremes,
3. environmental conditions: dust, oil, chemicals, salt, etc.,
4. constant vibration or impact, and 5. steam or smoke.
11. Do not put anything on or cover the unit with cloth, etc. Fire or unit trouble could result.
12. For DC powered systems, use Aiphone power supply model specified with system. If non-specified product is used, fire or malfunction could result.
GENERAL PRECAUTIONS
1. All the units, except for entrance station, is designed for indoor use only. Do not use outdoors.
2. The unit will be inoperative during a power outage.
3. In areas where broadcasting station antennas are close by, the intercom system may be affected by radio frequency interference.
4. Keep the intercom wires more than 12 inches (30 cm) away from AC 100~240V wiring. AC induced noise and/or unit malfunction could result.
5. Keep the unit more than 1 m away from Radio or TV set.
6. When strong light comes in on the unit's screen, the image looks white or silhouetted. But this is not a unit trouble.
PRECAUTIONS
- 3 -
1 SYSTEM CONFIGURATIONS
Standard System Configuration Diagram 6 Expanded System Configuration Diagram 8 Wiring Distance 9
2 UNIT
Unit (Entrance Station) 10 Combination Example for Entrance Station , Unit (Bus Control Unit and Others) 11 Residential Station , Security Guard Station 12
3 MOUNTING
Mounting the Entrance Station (1) 13 Mounting the Entrance Station (2) , (3) 14 Bus Control Unit and Power Supply Adapter 15 Residential Station , Optional Handset 16 Security Guard Station (Desk-top Mounting Using the GFW-S Stand) , (Mounted on Wall) 17
4 WIRING
Standard System (1) 18 Standard System (2) Station-to-Station Wiring 19 Standard System (2) Homerun Wiring 20 Expanded System 22 External Relay Connection 23
5 NAMES (ENTRANCE STATION)
Entrance Station (GH-VA, GH-DA, GH-NS, GH-10K), (GH-DA, GH-SW) 24
6 NAMES (RESIDENTIAL STATION)
Residential station (GH-1AD, GH-1KD) 24 Residential station (GH-1MD) 25
7 NAMES (SECURITY GUARD STATION)
Security Guard Station (GH-MK) 25
8 SETTING UP (ENTRANCE STATION)
Adjusting the Camera Angle , Entering Names and Addresses 26 Making Adjustments with the Mounting Gauge 27 Setting up the System 28 Programming (GH-NS) 29 Program Mode (GH-NS) 30
9 SETTING UP (SECURITY GUARD STATION)
Programming (GH-MK) 32 Program Mode (GH-MK) 34
10 OPERATIONS (ENTRANCE STATION)
Calling a Residential Station 36 Calling the Security Guard Station , Door Release 37
11 OPERATIONS (RESIDENTIAL STATION)
Responding to a Call , Call from the Doorbell Button (Individual Entrance Door) 38 Door Release , Turning on the Entrance Light 39 Calling the Security Guard Station , Automatic Entry (Doctor Call) Option 40 Emergency Alarm , Entrance Monitoring 41
12 OPERATIONS (SECURITY GUARD STATION)
Responding to a Call from an Entrance Station , Responding to a Call from a Residential Station 42 Calling a Entrance Station , Calling a Residential Station 43 Calling Another Security Guard Station , Emergency Call 44 Call Transfer Function , Call from the Doorbell Button , Callback Function 45
13 TECHNICAL PRECAUTIONS 46 14 SPECIFICATIONS 46
- 4 -
Cable: 1P x 2, 2-conductor cable solid copper & non-braided, polyethylene insulation
1P
Entrance
No. 2 to 5
Trunk line
No. 3 to 6
Door release
Entrance station
Security guard station
1P(Audio) 1P(Video) 1P
GH-BC
GH-MK
GH-VBC
1Px2
Trunk line No.1
1Px2
1P 1P
1Px2
1Px2
1Px2
1Px2
1Px2
PS24 PS24
PS24
PS24
Distribution
point
R1 R2
GH-4Z
GH-4Z
1Px2
1Px2
1Px2
Doorbell Doorbell Doorbell
1Px2
1Px2
1P 1P
1Px2
1Px2
1Px2
1Px2
Doorbell
Doorbell
GH-1MD
GH-1KD GH-1AD GH-1AD GH-1KDGH-1KD
GH-1KD
GH-1KD
Divided cabling with GH-4Z
Monitor to monitor cabling
Trunk line No.2
Light control
Timer
Light
AC
GH-RY
Standard system
Doorbell
On the same trunk line, do not have two wiring methods mixed, Monitor to monitor & Divided cabling with GH-4Z
GH-1MD, unlike GH-1KD, is only available to connect on a trunk line with GH-4Z used
Max. 4 apartment stations can be linked per Residence (including max. 2 monitor stations)
Capacity 5 Entrance stations 2 Security guard stations 48 Residential stations
Cabling
- 5 -
Light
Orange
Orange
White
Blue
GH-4Z
B1 B2 R1 R2
B1 B2R1 R2
B1 B2R1 R2
B1 B2R1 R2
B1 B2 R1 R2
OUT 3 OUT 4
B1 B2 R1 R2
B1 B2 R1 R2
OUT 1
LINE OUT
LINE IN
OUT 2
BA
GH-4Z
BA
BA
1Px2 1Px2
1Px2 1Px2
1Px2
Doorbell
Doorbell
Divided cabling with GH-4Z
Trunk line No.1
Terminate the last GH-4Z
Monitor to monitor cabling
Trunk line No.2
1Px2
1Px2
1Px2
1P
R1 R2
B1 B2
C
CE
C
CE
B1 B2
B1 B2
OUT
IN
R1 R2
R1 R2
OUT
IN
GH-1MD
GH-1KD
GH-1KD
OUT
OUT
IN
IN
OUT
IN
C
CE
B1 B2
B1 B2
R1 R2
R1 R2
BA
GH-1KD
GH-1ADGH-1AD
OUT
IN
OUT
IN
C
CE
B1 B2
B1 B2
R1 R2
R1 R2
BA
GH-1KD
OUT
IN
OUT
IN
C
CE
B1 B2
B1 B2
R1 R2
R1 R2
BA
R1 R2
R1 R2
C
CE
OUT
IN
R1 R2
R1 R2
C
CE
Trunk line
No. 3 to 6
1Px2
1Px2
B1 B2B1 B2
A1 A2
B1 B2B1 B2 B1 B2B1 B2
OUT1
IN1
A1 A2
IN2
A1 A2
IN3
A1 A2
IN4
A1 A2
IN5
OUT2 OUT3 OUT4 OUT5 OUT6
+
R1 R2
+
-
Power supply
Power supply
Power supply
AC
GH-BC
+
-
AC
+
-
AC
+
Video Entrance station No. 2 to 5
Doorbell
GH-1KD
OUT
IN
OUT
IN
C
CE
B1 B2
B1 B2
R1 R2
R1 R2
BA
R1 R2
ELB ELC ELM+RY RY-A1 A2CN2
CN1
GH-DA
GH-RY
GH-NS
GH-10K
GH-VA
2nd
GH-MK
GH-MK
Power supply
+
-
CN3
CN100
C
CE
+
-
R1 R2
R1 R2
C
CE
R1 R2
R1 R2
Doorbell
Distribution point
SW4
SW4
IN
IN
--
STDEXP
Light control
Timer
Entrance station
CN1 CN3
Door bell
Door bell
+
-
AC
Wiring
- 6 -
1
SYSTEM CONFIGURATIONS
GH-DA + GH-SW
GH-DA + GH-NS, GH-10K
GH-VA + GH-DA + GH-SW
GH-VA + GH-DA + GH-NS, GH-10K
GH-BC
GH-VBC
2
B
A
C
1
3
E
D
F
5
K
J
L
4
H
G
I
6
N
M
O
8
U
T
V
7
R
Q
P
S
Y
X
W
Z
9
0
GH-MK
Max. 5 (3 per trunk)
Max. 2
GH-1KD
GH-1KD
GH-1KD
GH-VA
GH-DA
GH-4Z
GH-1KD
GH-1KD
GH-1KD
GH-1KD
a b
c d
e
1-1
GH-1KD + GH-HSGH-1MDGH-1AD
GH-VA GH-1KD / GH-4Z
GH-VBC GH-VBC GH-VBC
SW
SW
STD EXP
SW
STD EXP
SW
STD EXP
Max. 6
Max. 48
Max. 25 / Trunk
Max. 48
Max. 25 / Trunk
[1]
[2]
[3]
[4]
GH-VBC
b
a
e
c d
(1) (2) (3)
:A :V :P
()
[5]
[5]
[6]
[7]
[9]
[10]
[10]
[10]
[10]
[10]
[10]
[10]
[11] [12] [13]
[14]
DP
[8]
PS PS PS
150 m 150 m 150 m
PS
PS
PS-2410LC
PS-2410LD
PS-2410DIN
AC AC
AC
PS
[5]
PS
[5]
PS
[5]
PS
GH-4Z
GH-1KD
GH-1KD
GH-1KD
GH-1KD
Max. 6
[9]
[10]
[10]
[10]
[10]
1
2
2
1
1
2
1
1
2
Trunk
#6 ~ #2
Trunk
#1
- 7 -
1-1
Standard System Configuration Diagram
(1) Audio signal line (2) Video signal line (3) Power supply line a. Entrance station (For details, see 2-1 and 2-2) [1] Video/audio + digital name scrolling type
GH-VA + GH-DA + GH-NS, GH-10K
[2] Video/audio + direct selection type
GH-VA + GH-DA + GH-SW
[3] Audio + digital name scrolling type
GH-DA + GH-NS, GH-10K
[4] Audio + direct selection type
GH-DA + GH-SW b. Bus control units [5] Power supply adapter PS-2410LC, PS-2410LD, PS-2410DIN [6] Video bus control unit GH-VBC GH-VBC can be used as an extension adapter as well. To do so,
set the setting switch to "EXP." (2 units per trunk line) [7] Bus control unit GH-BC [8] Distribution terminal (junction): sold separately c. Residential station (For details, see 2-4):
Station-to-station wiring
d. Residential station (For details, see 2-4): Homerun wiring
Do not mix station-to-station wiring and homerun wiring. [9] 4-way video junction unit GH-4Z [10] Color video residential station GH-1KD [11] Audio residential station GH-1AD [12] Black &White video residential station GH-1MD [13]
Color video residential station +handset (option) GH-1KD + GH-HS e. Security Guard Station [14] Security guard station GH-MK
Capacity
Entrance Station Maximum 5 stations
(up to 3 stations per trunk)
Residential Station Maximum 48 stations
(up to 25 stations per trunk)
Security Guard Station Maximum 2 stations Residential stations
in the same residence
Maximum 4 stations (up to 2 monitor stations)
4-way video junction unit Maximum 6 units per trunk
- 8 -
GH-VA + GH-DA +
GH-NS, GH-10K
GH-MK
Max. 8 (3 per trunk)
Max. 2
GH-VA
GH-VA
GH-1KD / GH-4Z
a
e
1-2
#2
#3 #4
#2
#3
#4
(1) (2) (3)
:A :V :P
12
#1
#2
#1
#2
#3
#4
[1]
a
e
a
e
f
GH-BC
GH-BC
2
B
A
C
1
3
E
D
F
5
K
J
L
4
H
G
I
6
N
M
O
8
U
T
V
7
R
Q
P
S
Y
X
W
Z
9
0
GH-DA
GH-DA
GH-BC
GH-VBC
b
GH-VBX
GH-BCX
[2]
#1
#1
f
#2
#4
#3
DP
GH-VA + GH-DA +
GH-NS, GH-10K
GH-MK
Max. 8 (3 per trunk)
Max. 2
a
e
2
B
A
C
1
3
E
D
F
5
K
J
L
4
H
G
I
6
N
M
O
8
U
T
V
7
R
Q
P
S
Y
X
W
Z
9
0
#2
[3]
DP
[3]
DP
[3]
DP
[3]
PS-2410LC
PS-2410LD
PS-2410DIN
AC AC
AC
PS
PS
PS
PS
PS
PS
PS
PS
PS
Max. 125
Max. 25 / Trunk
c d
()
PS
[4]
[4]
[4]
[4]
[4]
[4]
[4]
[4]
[4]
b c d
()
b
c d
()
b
c d
()
b c d
()
- 9 -
1-2
Expanded System Configuration Diagram
1. Common trunk line #1, 2
2. Sub trunk line #1 - 4
Sub trunk line #2 - #4 are the same as #1. Maximum 125 units per sub trunk line. (1) Audio signal line (2) Video signal line
(3) Power supply line a. Entrance station (For details, see 2-1 and 2-2) b. Bus control unit c. Residential station (For details, see 2-4):
Station-to-station wiring (For details, see 1-1) d. Residential station (For details, see 2-4):
Homerun wiring (For details, see 1-1)
Do not mix station-to-station wiring and homerun wiring. e. Security Guard Station f. Expanded bus control unit [1] Expanded video bus control unit GH-VBX [2] Expanded bus control unit GH-BCX [3] Distribution terminal (junction): sold separately [4] Power supply adapter PS-2410LC, PS-2410LD, PS-2410DIN
1-3
Wiring Distance
DP = Distribution Point
Capacity
Entrance Station Maximum 16 stations
(up to 3 stations per trunk)
Residential stations per sub trunk line
Maximum 125 stations (up to 25 stations per trunk)
Residential Station Maximum 500 stations Security Guard Station Maximum 4 stations
Residential stations in the same residence
Maximum 4 stations (up to 2 monitor stations)
Diameter of wires
0.65 mm
(22 AWG)
0.8 mm
(20 AWG)
1.0 mm
(18 AWG)
GH-BC - DP
DP - GH-DA
GH-VBC - GH-VA
GH-MK - DP
DP - farthest residential station (R1-R2) (Includes system with GH-4Z)
GH-VBC - farthest residential station (1 monitor units/residence) (Includes system with GH-4Z)
GH-VBC - farthest residential station (2 monitor units/residence) (Includes system with GH-4Z)
GH-VBC (SW: STD)
- GH-VBC (SW: EXP) GH-BC - power supply
GH-VBC - power supply
GH-NS - power supply
GH-MK - power supply
5 m
(16')
5 m
(16')
5 m
(16')
300 m
(980')
300 m
(980')
300 m
(980')
300 m
(980')
300 m
(980')
300 m
(980')
5 m
(16')
5 m
(16')
300 m
(980')
300 m
(980')
150 m
(500')
150 m
(500')
100 m
(330')
-
-
-
-
150 m (490')
-
-
-
-
100 m (330')
100 m (330')
50 m
(165')
-
-
-
-
-
2500 m
(8200')
--
2500 m
(8200')
--
5 m
(16')
--
150 m
(500')
--
300 m
(980')
--
300 m
(980')
--
300 m
(980')
150 m (500')
-
-
-
150 m
(500')
100 m (330')
-
150 m
(500')
100 m
(330')
50 m
(165')
150 m
(500')
Common trunk line (Maximum 2 trunk lines) total wiring length per trunk line
Sub trunk line (Maximum 4 trunk lines) total wiring length per trunk line
GH-BC - GH-BCX
GH-VBC -GH-VBX
GH-DA - GH-BCX
GH-VA - GH-VBX
GH-BCX - farthest residential station (R1-R2) (Includes system with GH-4Z)
GH-VBX - farthest residential station (1 monitor units/residence) (Includes system with GH-4Z)
GH-VBX - farthest residential station (2 monitor units/residence) (Includes system with GH-4Z)
- 10 -
2
UNIT
2-1
Unit (Entrance Station)
[1] Speech module panel GH-DP [2] Speech module GH-DA [3] Camera module panel GF-VP [4] Camera module GH-VA [5] 1-call button panel GF-1P [6] 2-call button panel GF-2P [7] 3-call button panel GF-3P [8] 4-call button panel GF-4P [9] Call switch module GH-SW [10] Digital name scroll module panel GF-NSP [11] Digital name scroll module GH-NS [12] RS-232C cable (enclosed with GH-NS) [13] Digital keypad module panel GF-10KP [14] Digital keypad module GH-10K [15] Address module panel GF-AP [16] Blank panel GF-BP [17] Address module GH-AD [18] 3-module front frame GF-3F [19] 2-module front frame GF-2F [20] Mounting bracket (enclosed with GF-3F and GF-2F) [21] 3-module back box GF-3B [22] 2-module back box GF-2B [23] Joint pipe (enclosed with GF-3B and GF-2B) [24] Mounting gauge (enclosed with GF-3B and GF-2B) [25] Rain hood GF-nH (option) [26] Surface-mount box GF-202B (option) [27] Hooded surface-mount box GF-nHB (option) [28] 80 cm (32") connection cable GF-C (option)
[1] [2] [3] [4]
[5] [6] [7] [8] [9]
[10] [11] [12] [13]
[15] [16] [17]
[18] [20] [19] [20]
[21] [22] [23] [24]
[25] [26] [27] [28]
[14]
- 11 -
2-2
2-3
Combination Example for Entrance Station
1. Audio only. Direct selection (8 stations).
2. Video/audio. Direct selection (8 stations).
3. Audio only. Digital name scrolling.
4. Video/audio. Digital name scrolling.
Unit (Bus Control Unit and Others)
[1] Bus control unit GH-BC [2] Special screwdriver (enclosed with GH-BC) [3] CD (contains operation manual and setup tool)
(enclosed with GH-BC) [4] Video bus control unit GH-VBC [5] 4-way video junction unit GH-4Z [6] Expanded bus control unit GH-BCX [7] Expanded video bus control unit GH-VBX [8] External relay GH-RY [9] Mounting screws (enclosed with GH-RY) [10] Power supply adapter PS-2410LC [11] Power supply adapter PS-2410LD (N/A in N.America) [12] Power supply adapter PS-2410DIN (N/A in N.America)
AIPHONE
AIPHONE
AIPHONE
AIPHONE
12
34
[1] [2] [3]
[4]
[6]
[5]
[8]
[10] [11] [12]
[7]
[9]
- 12 -
2-5
Security Guard Station
[1] Security guard station GH-MK [2] Mounting screws (enclosed with GH-MK) [3] RS-232C cable (enclosed with GH-MK)
2-4
Residential Station
[1] Audio residential station GH-1AD [2] Color monitor residential station GH-1KD [3] Mounting screws (enclosed with GH-1AD and GH-1KD) [4] Black-and-white monitor residential station GH-1MD [5] Mounting screws (enclosed with GH-1MD) [6] Optional handset GH-HS
GH-HS can be installed only for the color monitor residential station GH-1KD.
[1] [2]
2
B
A
C
1
3
E
D
F
5
K
J
L
4
H
G
I
6
N
M
O
8
U
T
V
7
R
Q
P
S
Y
X
W
Z
9
0
[3]
[1] [2] [3]
[4] [5] [6]
- 13 -
Mounting the Entrance Station (1)
[1] Back box [2] Joint pipe [3] Back box assembly dimensions [4] Special screwdriver (enclosed with GH-BC)
1. Mounting the back box
• Make a hole for the cable.
• Use the joint pipe to assemble the back box.
• Make sure the back box is mounted level.
• Mount the camera and GH-NS module at eye-level for the
average height of an adult.
Do not mount the back box on a surface that is recessed by 15 mm (1/2") or more from the external surface of the wall.
2. Set up the modules.
• For information on what modules can be used, see 2-1 and 2-2.
6 GH-SW modules can be used. If you would like to connect 7 modules or more, please contact Aiphone.
3. Mount each module panel to the front frame.
• Mount the panels from behind the front frame.
Insert the notch into the slots on both sides and slide it downward.
4. Mount each module to the mounting bracket.
Set the modules in the mounting bracket until they click in place.
5. Options a. Rain hood GF-H b. Surface-mount box GF-202B c. Hooded surface-mount box GF-HB d. 80 cm (32") connection cable GF-C
3-1
3
MOUNTING
1
2
3
4
5
a
b
295mm (11-5/8")
W
44mm (1-3/4")
25mm (1")
25mm (1")
25mm (1")
W
200mm (7-7/8")
44mm
(1-3/4") 15mm (1/2")
x 1 x 2 x 3 x 4 x 5 x 6 x 7 x 8 x 9
110 245 380 515 650 785
920 1055 1190
W (mm)
4-5/16" 4-5/8" 15" 20-1/4" 25-9/16" 30-7/8" 36-1/4" 41-9/16" 46-1/8"
W (inch)GF-2B/3B
15mm (1/2")
[4]
[2]
[3]
[1]
[2]
c
d
[1]
[1]
- 14 -
3-2 3-3
Mounting the Entrance Station (3)
1. Example of interconnection of modules.
2. Use GF-C to connect to the name scrolling module.
3. To position the speech module in the center row, run GF-C through the joint pipe in advance.
Mounting the Entrance Station (2)
1. Remove the terminal cover.
2. From the speech module to the next module, insert the attached connector into the socket. Make sure to run the cable under the terminal cover for protection.
3. Connect the connectors between the modules with cables.
4. Run the connection cable through the joint pipe (which you should have made open in advance) and connect CN1 of GH­SW to the next row.
5. Put back the terminal cover.
1
23
CN3
CN1
GH-VA
GH-DA
CN1
CN3
CN100
CN2
CN1
CN2
GH-DA
GH-AD
GH-NS
GH-10K
GF-C
GH-DA
GH-AD
GF-BP
GF-3B GF-3B
GH-10K
GH-VA GH-NS
GF-C
GH-DA
GF-3B GF-3B GF-3B
1
2
3
4
5
1
0
3
O
N
1
2
3
4
C
N
2
C
N
1
GH-DA
1
0
3
ON
1
2
3
4
C
N
2
C
N
1
GH-DA
1
0
3
O
N
1
2
3
4
O
N
O
N
1
2
1
0
3
O
N
1
2
3
4
O
N
CN1
GH-DA
CN2
GH-SW
CN2
CN1 CN2
CN1 CN2
CN1
CN2
CN1
CN2
CN1
- 15 -
3-4
Bus Control Unit and Power Supply Adapter
[1] Din rail (W-DIN11) [2] Screw hole [3] POWER switch [4] Power On LED (green) [5] Lock release lever [6] Wall mounting screws (x2)
1. Mount GH-BC and GH-VBC to the Din rail. Click unit into place.
To remove GH-BC and GH-VBC, pull the lock release lever
down.
If there is a problem with the system, check the power supply
wiring. Turn off the GH-BC and GH-VBC power switch and then turn the switch back on after four seconds. This will reset the entire system.
2. Mount GH-BC and GH-VBC directly to the wall surface.
3. Mount GH-4Z to the Din rail.
To remove GH-4Z, pull the lock release lever down.
4. Mount GH-4Z directly to the wall surface.
5. Mount GH-BCX and GH-VBX to the Din rail. To remove GH­BCX and GH-VBX, pull the lock release lever down.
GH-BCX and GH-VBX cannot be mounted directly to the wall surface.
6. Power supply adapter PS-2410LC, PS-2410LD, PS-2410DIN Red: + Black: -
GH-BC
GH-VBC
GH-4Z
GH-BC
GH-VBC
GH-4Z
GH-BCX GH-VBX
ON
OFF
[1]
[6]
[1]
[1]
[1]
[2]
[5]
[4]
[2]
[3]
[5]
[5]
[1]
[1]
[2]
[2]
[6]
12
3
5
6
4
+
+
+–
PS-2410LDPS-2410LC
PS-2410DIN
[1]
Loading...
+ 32 hidden pages