Ag Spray BASPOTSPRAYERK User Manual

Owner's Manual
Model: BASPOTSPRAYERK (5302060)
(Bolt-On Boomless Nozzle Assembly for Spot Sprayers with 'Top-Mounted' pumps)
Thank you for purchasing this product. The purpose of this manual is to assist you in operating and maintaining your boomless nozzle setup. Please read
Pump is shown but
not included in this assembly.
it carefully, as it furnishes information which will help you achieve years of trouble-free operation.
Warranty/Parts/Service
Products are warranted for one year from date of purchase against manufacturer or workmanship defects.
Commercial users have a 90 day warranty.
Your authorized dealer is the best source of replacement parts and service. To obtain prompt, efficient service, always remember to give the following information...
- Correct Part Description and/or part number.
Features/Benefits
Nozzle features a multi-patented round covered orifice
• design which improves spray pattern & distribution.
No small orifices or slots to get plugged up.
1/4" (MNPT) inlet threads (Male National Pipe Thread)
Nozzle produces a very even, large droplet spray
• pattern.
Superior wear & chemical resistance.
Eliminates cumbersome boom 'arms'.
Eliminate most 'normal' boom maintenance.
Spray easily around obstacles & over uneven terrain
All full pattern spray nozzles were tested at a height of
• 36 inches. (recommended operating height is between 18 & 48 inches.) These nozzles are designed to provide a full left-hand to right-hand spray pattern from a single centrally mounted nozzle.
Part descriptions and part numbers can be obtained from the illustrated parts list section(s) of this manual.
Whenever you need parts or repair service, contact your distributor/dealer first. For warranty work, always take your original sales slip, or other evidence of purchase date, to your distributor/dealer.
www.agspray.com
1100 New Industry Lane
Hopkinsville, KY 42240
P: 800-637-7172 F: 270-885-7392
Form No. 2002 [5008306 (11/10)] Printed in the U.S.A.
104 Eastman Street
Greenwood, MS 38930
P: 800-844-4524 F: 662-455-4442
1563 S. Oates Street
Dothan, AL 36301
P: 800-227-4098 F: 334-673-1974
Nozzle Height Adjustment
After Spraying
Nozzles can be used at various heights within the recommended range. However, this will affect the spray pattern width and the gallons per acre (GPA) applied.
Adverse Wind Conditions
With boomless spray nozzles, as with other spraying methods, high or gusty wind conditions can cause drifting or pattern movements, adversely affecting spray coverage. If this occurs, wait for more favorable conditions before continuing.
Plumbing Requirements
Make sure that all plumbing components and feed lines can properly supply the nozzle or nozzles at their rated GPM and PSI. The type of pump used as well as the size and length of the feed line will also affect how efficiently the volume is delivered to the nozzle or nozzles. Minimum hose size and plumbing requirements are:
Nozzle
Qty.
1 2 1 2 1 2
Nozzle Size
1/4" MNPT Nozzle
1/4" MNPT Nozzles
1/2" MNPT Nozzle
1/2" MNPT Nozzles
1" MNPT Nozzle
1" MNPT Nozzles
Hose Size
1/2" I.D. Hose 3/4" I.D. Hose
1" I.D. Hose
1" I.D. Hose 1-1/4" I.D. Hose 1-1/2" I.D. Hose
Proper Nozzle Operation
To insure proper nozzle operation all pressure readings must be taken directly before the nozzle or nozzles.
After use, fill your sprayer tank part way with water. Start your sprayer, and allow the clear water to be pumped through this plumbing system and out through the spray nozzle. Refill your tank about half full with plain water and use FIMCO Tank Neutralizer and Cleaner, and repeat cleaning instructions above. Flush your entire sprayer, including this boomless plumbing setup, with the neutralizing/cleaning agent, then flush out one more time with plain water. Follow the chemical manufacturer's disposal instructions of all wash or rinsing water. For the boomless nozzle, remove the tip and screen from the nozzle assembly. Wash these items out thoroughly. Blow the orifice clean and dry. If the orifice remains clogged, clean it with a fine bristle (NOT WIRE) brush, or with a toothpick. Do not damage the orifice. Water rinse and dry the tips before storing. The screen at the tip (Item 24) is between the elbow (Item 19) and the adaptor (Item 3).
Winter Storage
Drain all water out of your sprayer, paying special attention to your pump, handgun, and valve(s). These items are especially prone to damage from chemicals and freezing weather.
Your sprayer should be winterized before storage by pumping a solution of RV antifreeze through the entire plumbing system. This antifreeze solution should remain in the plumbing system during the winter months. When spring time comes and you are preparing your sprayer for the spray season, rinse the entire plumbing system out, clearing the lines of the antifreeze solution. Proper care and maintenance will prolong the life of your sprayer.
SPRAYING SAFETY:
ALWAYS WEAR PROTECTIVE CLOTHING WHEN SPRAYING AND/OR HANDLING ANY AND ALL CHEMICALS.
'BOOMINATOR' Boomless (Full) Spray Tip Model #1200PS
(1/4" MNPT)
Spraying Pressure
PSI
20 1.0
30 1.2
40 1.4
1/4" MNPT
Flow Rate
GPM
Tested Height = 24" Tested Height = 36"
Spray Distance Spray Distance
12 Ft.
12 Ft.
12 Ft.
'BOOMINATOR' Boomless (Full) Spray Nozzle (#1200PS)
14 Ft.
14 Ft.
14 Ft.
Speed (MPH)
1 2 3 4 5 6 7
Gallons Per Acre (GPA)
35 18 12 9 7 6 5
42 21 14 10 8 7 6
49.5
25
16.5
12 10 8 7
(Typical Spray Pattern)