There is a tab for every channel of control with Control Valve Congurations and related settings.
Valve Response 1
fast speed of valve, decrease to slow response time
default = 40%
Servo Valve
Strip Till Control
Channel 1
Control Valve Conguration
Channel 2Channel 3 Auxiliary
Servo
Valve
Response 1
40 %
Valve
Response 2
8 %
Response
Threshold
15
Allowable
Error
2 %
Shaft Speed
Calibration
180 pls/rev
Max Metering
Speed
100 rpm
Valve Response 2
slow speed of valve, decrease to slow response time
default = 8%
Response Threshold
point where system switches between using
Response 1 and Response 2, increase to slow
response time, default = 15
Allowable Error
error allowed before making rate control adjustments
Shaft Speed Calibration
pulses/revolution of metering shaft
Max Metering Speed
maximum allowable RPM of metering system
Quick Reference Guide
PN ?????? Rev A
AL: 2006315 - ENG Rev B
PN 2006313 Rev A
1
1
PWM Valve
Strip Till Control
Channel 1
Control Valve Conguration
Channel 2Channel 3
PWM
PWM Frequency
PWM Gain
Zero Flow Offset
DirectCommand
TM
Strip Till / Air Cart
PWM Frequency
frequency valve is pulsed at, settings come from
manufacturer, typical range: 100-125 Hz
PWM Gain
Auxiliary
Allowable
Error
100
100
30
2 %
Shaft Speed
Calibration
180 pls/rev
Max Metering
Speed
100 rpm
decrease to slow response time
Zero Flow Offset
duty cycle used to start rotating meter shaft, metering
system will not turn off if setting is too high,
default = 30
Allowable Error
error allowed before making rate control adjustments
Linear Actuator/
Clutch Settings
Strip Till Control
Channel 1
Control Valve Conguration
Channel 2Channel 3
Single Bin Actuator
Servo
PWM
Single Bin Actuator
Multiple Bin Actuator, Main Only
Multiple Bin Actuator, Main + Channel
Auxiliary
Allowable
Error
2 %
Shaft Speed
Calibration
180 pls/rev
Max Metering
Speed
100 rpm
Shaft Speed Calibration
pulses/revolution of metering shaft
Max Metering Speed
maximum allowable RPM of metering system
Single Bin Actuator
one actuator controlling product
Multiple Bin Actuator, Main only
up to 3 actuators plus one main drive clutch controlling
product
Multiple Bin Actuator, Main + Channel
up to 3 actuators, one main drive clutch, and maximum
of 3 meter clutches controlling product
IMPORTANT: When using linear actuator, all channels must be set to the same control valve
conguration regardless if channels are not in use.
Note: Additional information on Actuator/Clutch Logic can be found in the display user manual.
Quick Reference Guide
PN ?????? Rev A
AL: 2006315 - ENG Rev B
PN 2006313 Rev A
2
2
DirectCommand
TM
Strip Till / Air Cart
NOTE: Settings and control characteristics are the same for all three types of Linear Actuator
Control Valve Congurations.
Actuator Response 1
fast speed of actuator, decrease to slow response
time, default = 90%
Actuator
Channel 1
Control Valve Conguration
Channel 2
Single Bin Actuator
Actuator
Response 1
Actuator
Response 2
18 %
Strip Till Control
Channel 3
Auxiliary
Response
Threshold
4
Allowable
Error
2 %90 %
Shaft Speed
Calibration
180 pls/rev
Max Metering
Speed
100 rpm
Actuator Response 2
slow speed of actuator, decrease to slow response
time, default = 18%
Response Threshold
point where system switches between using Actuator
Response 1 and Actuator Response 2, increase to
slow response time, default = 4
Allowable Error
error allowed before making rate control adjustments
Shaft Speed Cal
pulses/revolution of metering shaft
Max Conveyor Speed
maximum allowable RPM of metering system
Auxiliary tab
Strip Till Control
Channel 1
Fan
Fan Speed Cal
Min Speed
Max Speed
Channel 2
4 pls/rev
80 rpm
4000 rpm
Low Fan Speed
Shutoff
Channel 3
Rate Not Responding Threshold
Rate Threshold
Auxiliary
30 %
Fan Speed Calibration
pulses/revolution of blower fan
Min Speed
user entered minimum allowable fan RPM
Max Speed
user entered maximum allowable fan RPM
Low Fan Speed Shutoff
application is suspended if fan RPM drops below
minimum speed setting, when selected
Rate Threshold
percent difference between actual and target rate
Quick Reference Guide
PN ?????? Rev A
AL: 2006315 - ENG Rev B
PN 2006313 Rev A
3
3
DirectCommand
Strip Till / Air Cart
To start the Field Operation Wizard and load a conguration:
Conguration
Start Field Operation
To view run screen:
Product Control Toolbox
To change values shown on Product Tab and in Product Control
DAP
Potash
Sulfur
200
200
250
250
20
20
1
200
2
150
Flow:
Container:
3.6 lb/min
50 ft
Toolbox go to the next page where the Rate Control Settings
screen is explained.
Target Rate
the desired amount of product to apply
Actual Rate
3
actual rate of product being applied as determined
by the ow sensor
TM
60 ft 0 in
1
200
2
150
Product in Bin
Target Rate #1 & #2
preset application rates that allow a quick change between rates
Manual Valve Control
allows operator manual control of valve
Prescription
allows rates to be determined by a loaded prescription
Up and Down Arrows
allow rates to be adjusted manually
Settings button
opens Rate Control Settings screen (explained on next page)
Quick Reference Guide
PN ?????? Rev A
AL: 2006315 - ENG Rev B
PN 2006313 Rev A
4
4
Application Conguration
DirectCommand
TM
Strip Till / Air Cart
Rate Control
DAP (lb)
Rate 1
Potash (lb)
Rate 1Rate 2
Sulfur (lb)
Rate 1Rate 2
Containers
200
250
20
To access the Rate
Control Settings window:
Rate Control Settings
Rate 2
1501
3001
301
Increment
Increment
Increment
DAP
Minimum Flow
0.00 lb/min
Minimum Flow
0.00 lb/min
Minimum Flow
0.00 lb/min
250
250
Rate 1 and Rate 2
Rx
allows operator to set
desired target rates
Increment
Rx
values used when using
up and down arrows in the
Product Control Toolbox
Rx
Rx
press to load a map-based
prescription le
Rate Control
Containers
Bin 2 - DAP
Full:
Current:100 ft
Bin 2 - Potash
Full:
Current:100 ft
Bin 3 - Sulfur
Full:
Current:15 ft
100 ft
100 ft
15 ft
Rate Control Settings
3
3
3
3
3
3
3
10 ft
10 %
3
10 ft
10 %
3
1.5 ft
10 %
Quick Reference Guide
PN ?????? Rev A
AL: 2006315 - ENG Rev B
PN 2006313 Rev A
Bin Full
press to ll
container
Bin Partially Filled
press to specify
container amount
Bin Empty
press to empty
container
3
1.5 ft
10 %
Tank Alarm
Setting
can set % remaining or amount
remaining for low
container alarm
5
5
Seeding Conguration
DirectCommand
TM
Strip Till / Air Cart
Rate Control
Wheat (lb)
Rate 1
DAP (lb)
Rate 1Rate 2
Potash (lb)
Rate 1Rate 2
Containers
0.00
0.00
0.00
To access the Rate
Control Settings window:
Rate Control Settings
Rate 2
0.000.00
0.000.00
0.000.00
Increment
Increment
Increment
Wheat
Minimum Flow
0.00 lb/min
Minimum Flow
0.00 lb/min
Minimum Flow
0.00 lb/min
0.00
0.00
Rate 1 and Rate 2
Rx
allows operator to set
desired target rates
Increment
Rx
values used when using
up and down arrows in the
Product Control Toolbox
Rx
Rx
press to load a map-based
prescription le
Rate Control
Containers
Full:
Current:
Bin 2 - DAP
Full:
Current:50 bu
Bin 3 - Potash
Full:
Current:30 bu
50 bu
30 bu
Rate Control Settings
Quick Reference Guide
Disabled
5 bu
10 %
3 bu
10 %
PN ?????? Rev A
AL: 2006315 - ENG Rev B
PN 2006313 Rev A
Bin Full
press to ll
container
Bin Partially Filled
press to specify
container amount
Bin Empty
press to empty
container
3 bu
10 %
Tank Alarm
Setting
can set % remaining or amount
remaining for low
container alarm
6
6
DirectCommand
TM
Strip Till / Air Cart
Rate
124 +
104 - 124
84 - 104
64 - 84
44 - 64
0 - 44
70.6 ac
Wheat
Channel 1
Wheat
Channel 2
700
Strip Till Control
Channel 3
Product
Density
Conveyor 1
Rate
12
20
0
RPM
0
58 lb/ft
0.64 ft3/rev
Wheat
DAP
Potash
3
025
3
0.00
0.00
0.00
0.00
0.00
0.00
bu/ac
bu/ac
bu/ac
9.0 mph
1
0.00
2
0.00
Flow:0.00 bu/min
80 ft 0 in100%
1 2 3
Start
Prime
1
2
3
252570025
RPM
Strip Till Control button
- on/off state of control channel
- shaft speed RPM
- fan speed RPM
Press button to display Strip Till Control window.
Product Density
value (lb/ft3), is stored with each product, use
numeric keypad to edit
Conveyor Rate
volume of product dispensed (ft3/rev) by one
revolution of the meter drive shaft
Static
Calibration
In-Field
Calibration
Prime
Channel 1
Revolutions
0.25
Channel 2
Revolutions
0.25
Channel 3
Revolutions
0.25
Air Cart Prime
Start
Prime
Static
Calibration
performs automated routine to
calibrate each metering circuit while
machine is stationary
In-Field
Calibration
performs automated routine to adjust
the calibration number for the selected
metering circuit if there is a difference
between the amount of product logged
compared to what was actually applied
Press the Prime button to access the Air Cart
Prime window.
User dened revolutions necessary to prime
meter shafts.
Independent settings for each metering circuit.
Quick Reference Guide