Ag Leader Versa DirectCommand Sprayer Reference Guides

Create Conguration
DirectCommand
TM
Sprayer
Enter Settings
Calibrate Pressure
Controller
Settings
Application
Conguration Product
Start of Conguration Wizard
Calibrate
Application
Press to Highlight Conguration
4930rx
Pressure
Controller
Settings
Flow Meter Calibration
pulses/gallon found on ow meter
(for Raven divide by 10)
Flow Control Delay
used to eliminate unwanted ow corrections at the start of pass, typical setting = 1 –2 sec
Flow Meter Calibration
120 pls/gal
Flow Control Delay
0 s
Control Valve
Settings
Controller Settings
Rate Off
Flow Control Valve
Hold
Auxiliary Valve 1
Close
Auxiliary Valve 2
Close
Rate Error Alarm
Threshold
30 %
Timeout
5 s
Control Valve Settings
opens Control Valve Settings screen (discussed on next page)
Rate Off: Flow Control Valve
Close: closes control valve when all booms are off Hold: maintains control valve position when all booms
are off
Rate Off: Auxiliary Valve 1 & 2
when boom sections are off, closes or opens an auxiliary valve Settings for up to 2 valves
Allowable Error
error allowed before ow rate changes
Threshhold and Timeout - duration and error
allowed before “Rate Not Responding” alarm
Quick Reference Guide
PN ?????? Rev A
AL: 2006310 - ENG Rev B
PN 2006313 Rev A
1
1
DirectCommand
Inline Servo / Bypass Servo /
Pump Servo / Calibrated Reow /
Ramsey Valve
Control Valve Settings
Control Valve
Valve
Response 1
100
Response Threshold
Inline Servo
Valve
Response 2
24 2 %
3
Allowable
Error
TM
Sprayer
Valve Response 1
fast speed of the valve, decrease to slow response time, default = 100%
Valve Response 2
slow speed of the valve, decrease to slow response time, default = 24%
Response Threshhold
point where system switches between using Valve Response 1 and Valve Response 2, increase to slow response time, default = 3 units/min
PWM 12 volt / PWM ground
Control Valve Settings
PWM 12 voltControl Valve
PWM Frequency
PWM Gain
PWM Standby
Zero Flow Offset
800
50
30
Allowable
Error100
2 %
Allowable Error
error allowed before making rate control adjustments
PWM Frequency
frequency valve is pulsed at, settings are from valve manufacturer, typical settings = 100-125 Hz
PWM Gain
decrease to slow response time
PWM Standby
duty cycle when booms are all off, setting must be greater than Zero Flow Offset, current PWM Duty Cycle can be viewed on Liquid Diagnostics screen while spraying
Zero Flow Offset
duty cycle used to start rotating the pump, if setting is too high pump will not turn off, default = 30%
Quick Reference Guide
PN ?????? Rev A
AL: 2006310 - ENG Rev B
PN 2006313 Rev A
2
2
Loading...
+ 2 hidden pages