Agilent Technologies 86100A, 86100B User Manual

Agilent 86100A/B Series Plug-in Modules Installation Guide
Installation Guide
Installation Instructions
Installation Instructions
This plug-in module is designed for use with the Infiniium DCA Agilent 86100A/B wide-bandwidth oscilloscope.
To install the module into the Infiniium DCA
1 Slide the module into an available front-panel slot.
You can remove or install a module while the instrument is in operation.
2 Finger tighten the two knurled screws on the module’s front panel.
Up to two modules can be inserted into the Infiniium DCA. All documentation (including specifications) for this plug-in module is located in the Infiniium DCA built-in information system (online help). To access the online help, touch or click Contents on the Help menu.
2
Installation Guide
Installation Instructions
Using an Agilent 86100A
The following modules require that firmware revision A.03.04 or later be installed in the Agilent 86100A/B:
83494A, Option 103 and Option 107 86102A 86103B 86105B 86107A 86111A 86111U 86113A 86115B 86116A 86116B 86117A 86117B 86118A
The firmware upgrade is enclosed in the module shipping container.
Agilent recommends that you use the latest version of firmware. To learn more about firmware upgrades, available modules, or the Infiniium DCA, please visit our website at http://www.agilent.com/comms/dca.
3
Installation Guide
General Safety Considerations
General Safety Considerations
This product has been designed and tested in accordance with IEC Publica­tion 1010, Safety Requirements for Electronic Measuring Apparatus, and has been supplied in a safe condition. The instruction documentation contains information and warnings which must be followed by the user to ensure safe operation and to maintain the product in a safe condition.
Install the plug-in module according to the enclosure protection provided. This instrument does not protect against the ingress of water. This instrument protects against finger access to hazardous parts within the enclosure.
WARNING If this product is not used as specified, the protection provided by the
equipment could be impaired. This product must be used in a normal condition (in which all means for protection are intact) only.
WARNING No operator serviceable parts inside. Refer servicing to qualified
service personnel. To prevent electrical shock do not remove covers.
WARNING To prevent electrical shock, disconnect the instrument from mains
before cleaning. Use a dry cloth or one slightly dampened with water to clean the external case parts. Do not attempt to clean internally.
CAUTION This product is designed for use in Installation Category II and Pollution
Degree 2 per IEC 1010 and 664 respectively.
4
Installation Guide
General Safety Considerations
CAUTION Electrical channel input circuits and the trigger input circuit can be damaged
by electrostatic discharge (ESD). Therefore, avoid applying static discharges to the front-panel input connectors. Prior to connecting any coaxial cable to the connectors, momentarily short the center and outer conductors of the cable together. Avoid touching the front-panel input connectors without first touching the frame of the instrument. Be sure that the instrument is properly earth-grounded to prevent buildup of static charge. Wear a wrist-strap or heel­strap.
CAUTION Optical channel fiber-optic connectors are easily damaged when connected to
dirty or damaged cables and accessories. When you use improper cleaning and handling techniques, you risk expensive instrument repairs, damaged cables, and compromised measurements. Before you connect any fiber-optic cable to the Infiniim DCA, Chapter 1 in the Infiniium DCA’s Quick Start Guide.
5
Installation Guide
Declaration of Conformity
Declaration of Conformity
6
Installation Guide
Regulatory Information
Regulatory Information
Radio-Frequency Electromagnetic Field Immunity - IEC 61000-4-3: 1995 passes criterion B
According to IEC 61000-4-3: 1995, degradation of system noise perfor­mance may be observed in some narrow frequency ranges when a 3 V/m radio-frequency electromagnetic field is applied to the 86100A,B mainframe with an 86102U, 86106B, or 86107A module installed.
Radio-Frequency Electromagnetic Field Immunity - IEC 61000-4-3: 1995 passes criterion C
According to IEC 61000-4-3: 1995, the degradation of normal performance within the specification limits may be observed in the 86100A,B mainframe with an 86107A module installed. The instrument software recognizes this temporary signal degradation and warns the user that the data is suspect. The warning prompts the user to press the Clear Display button. The user can then resume data acquisition. This required operator intervention results in a criterion C classification.
7
Notices
© Agilent Technologies, Inc. 2000-2002
No part of this manual may be repro­duced in any form or by any means (including electronic storage and retrieval or translation into a foreign lan­guage) without prior agreement and writ­ten consent from Agilent Technologies, Inc. as governed by United States and international copyright lays.
Manual Part Number
5969-5881
Edition
First edition, September 2002
Printed in USA
Agilent Technologies, Inc. Lightwave Division 3910 Brickway Boulevard Santa Rosa, CA 95403, USA
Warranty
The material contained in this document is provided as is, and is subject to being changed, without notice, in future edi­tions. Further, to the maximum extent permitted by applicable law, Agilent dis­claims all warranties, either express or implied, with regard to this manual and any information contained herein, includ­ing but not limited to the implied warran­ties of merchantability and fitness for a particular purpose. Agilent shall not be liable for errors or for incidental or conse­quential damages in connection with the furnishing, use, or performance of this document or of any information con­tained herein. Should Agilent and the user have a separate written agreement with warranty terms covering the mate­rial in this document that conflict with these terms, the warranty terms in the separate agreement shall control.
Technology Licenses
The hardware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license.
Safety Notices
CAUTION
Caution denotes a hazard. It calls attention to a procedure which, if not correctly per­formed or adhered to, could result in damage to or destruction of the product. Do not proceed beyond a caution sign until the indicated conditions are fully understood and met.
WARNING
Warning denotes a hazard. It calls attention to a procedure which, if not correctly per­formed or adhered to, could result in injury or loss of life. Do not proceed beyond a warning sign until the indicated conditions are fully understood and met.
Restricted Rights Legend
If software is for use in the performance of a U.S. Government prime contract or subcontract, Software is delivered and licensed as Commercial computer soft­ware as defined in DFAR 252.227-7014 (June 1995), or as a commercial item as defined in FAR 2.101(a) or as “Restricted computer software as defined in FAR
52.227-19 (June 1987) or any equivalent agency regulation or contract clause. Use, duplication or disclosure of Software is subject to Agilent Technologies standard commercial license terms, and non-DOD Departments and Agencies of the U.S. Government will receive no greater than Restricted Rights as defined in FAR
52.227-19(c)(1-2) (June 1987). U.S. Gov­ernment users will receive no greater than Limited Rights as defined in FAR
52.227-14 (June 1987) or DFAR 252.227­7015 (b)(2) (November 1995), as appli­cable in any technical data.