![](/html/3a/3a10/3a10173a5f64254d5e64b0dc132651b1dd03d695b95a77c54cf97c5d359fc776/bg1.png)
Identification of Product:
Manufacturer/Supplier:
Aeroflex USA, Inc.
Telephone:
Toll Free 866-AEROCEL (237-6235)
Fax Number:
(423)351-7368
Email Address: sales@aeroflexusa.com
Ingestion
3. COMPOSITION/INFORMATION ON INGREDIENTS
Carbon Black CAS No. 1333-86-4
Not required under normal use. If irritation persists, remove from exposure area
No required under normal use. Flush with water until all traces of the material are done.
Seek medical attention if irritation persists
If illness or adverse symptoms develop, obtain medical attention
Not required under normal use
1. PRODUCT AND COMPANY IDENTIFICATION
Closed Cell Elastomeric Thermal Insulation
No significant signs of any adverse health hazard are expected to occur as a result of inhalation exposure
Aerocel AC, CG, Continuous Tube, Non-Continuous Tube, Aerofit Fitting
Covers
Aerocel AC, CG, Continuous Tube
Non-Continious Tube, Aerofit Fitting Covers
No significant signs of any adverse health hazards are expected to occur as a result of eye contact
No Significant signs of any adverse health hazards are expected to occur as a result of skin contact
This product is an expanded, closed cell, sulfurcured rubber type compound. It contains synthetic polymer,
fillers, plasticizers and rubber chemicals.
Following are the main ingredients in this product:
Synthetic rubber (EPDM: Ethylene-Propylene-Therpolymer Rubber) CAS No. 25038-36-2
Aluminum Trihydrate CAS No. 21645-51-2
![](/html/3a/3a10/3a10173a5f64254d5e64b0dc132651b1dd03d695b95a77c54cf97c5d359fc776/bg2.png)
5. FIRE-FIGHTING MEASURES
Extinguishing Media
Carbon Dioxide, ABC dry chemical, Water spray and foam
Specific Hazards with regard to Fire-Fighting measures
Hazardous Combustion Products
6. ACCIDENTAL RELEASE MEASURES
If materials released/Spill
Collect spilled material and place it in an appropriate container for reuse or disposal
Water Spill:
Neutralizing Agent:
Handling Condition: No special precaution required
Storage Condition: Keep in dry normal storage
8. EXPOSURE CONTROL/PERSONAL PROTECTION
Engineering Controls: General ventilation
Personal Protection Negligible
9. PHYSICAL AND CHEMICAL PROPERTIES
Appearance:
Specific Gravity: 0.04-0.08
Service Temperature
.-57 to +1250C (-70 to 2570F)
0.036 at Mean temp 240C max
Water Absoration 5% by weight max
0.1 Perm-inch (0.15x1012kg/Pa s m) max
Flammability Self-extinguishing
Non-Continious Tube, Aerofit Fitting Covers
Product is insoluble. Collect spilled material and place in an appropriate container for reuse or
disposal
Approach from upwind side. Avoid breathing smoke, fumes or vapors on downwind side. Firefighters wear
protective clothing, especially eye protection, and self contained breathing apparatus
Material is stable under normal conditions. In the event of a prolonged fire, may generate Carbon Monoxide,
Carbon Dioxide, Low molecular weight alcohol/aldehydes and acid
Aerocel AC, CG, Continuous Tube