Aeroflex 1200S Data Sheet

RF Solutions
Designed for land mobile professionals
with demanding RF testing requirements,
the 1200 Super S has a sensitive 2 µV
triple conversion receiver capable of monitoring AM, FM and SSB carriers within the low band, VHF, UHF and high band ranges.
Depending on your specific needs, the 1200 Super S also gives you the choice of receiving straight “off the air” or through a direct connection to a T/R port.
Recognized for its versatility, the 1200 Super S supports DCS, DTMF and pulsed audio signaling formats.
The 1200 Super S also meets RF measurement needs for:
- RF frequency error
- RF power
- Audio frequency error
- CTCSS frequency
- CTCSS modulation
In duplex mode the 1200 Super S is capable of simultaneously generating and
receiving frequency offsets in 2.5 kHz steps. The duplex feature can be con­figured to operate in three modes:
- Testing using separate transmit and receive ports
- Testing using one common transmit/receive port
- “Off-the-air” duplex testing
With standard features like a 1000 MHz spectrum analyzer and built-in 1 MHz oscilloscope, the 1200 Super S virtually eliminates the need for costly additional equipment purchases. An optional tracking generator makes cable testing simple.
Paging Solutions
The versatility of the 1200 Super S also allows comprehensive testing of the most popular paging protocols, including encode/decode or 2-tone sequential, 5/6 Tone testing..
For those involved with advanced paging protocol systems, the AC510 option supports the following paging standards:
- Flex
- POCSAG
- Golay Sequential Code (GSC)
- NEC D3
Trunking Solutions
With the CLEARCHANNEL LTR
trunking option, the 1200 Super S is an ideal platform for testing LTR mobiles, portables and repeaters. For basic repeater testing, the 1200 Super S allows you to perform extensive receiver and transmitter tests. For more in-depth analysis, the LTR test option emulates the repeater system and
allows testing of home repeater access and next repeater access, including Handshake and Hand-off operation.
In addition, with 760 trunking channels, an internal tracking generator and user friendly LTR programming screens, the 1200 Super S is designed to give you the greatest control and flexibility possible.
Complex Functionality That’s Simple to Use
From the user interface to functions and displays, the 1200 Super S allows technicians of any skill level to fully utilize its vast testing resources.
- Intuitive user interface makes complex testing simple and efficient.
- CTCSS encode/decode feature makes it easy to work with sub-audible tones.
- A standard RS-232 port allows remote testing.
- Internal memory allows storage of up to 99 RF frequencies.
From programming automatic test sequences to executing standard measurements, the operating system of the 1200 Super S provides a high level of testing. Yet the 1200 Super S is so user­friendly, you’ll spend less time setting up tests and more time testing.
1200 Super S
Communications Service Monitor
A cost effective alternative for analog cellular, SSB, paging and mobile radio testing
Wireless- Radio Test Sets
Analog meter and VFD (Vacuum Fluorescent Display) offer high visibility in all lighting conditions
Convenient service analyzer with duplex and simplex connectors
Standard internal spectrum analyzer to 1 GHz
Built-in 1 MHz oscilloscope Comprehensive testing of analog
and advanced digital paging with the AC510 option
1200 Super S
1
http://www.ifrinternational.com
Specification
Frequency Range
250 kHz to 999.9999 MHz
Resolution
100 Hz
Accuracy
Same as Master Oscillator
Range
-127 to -20 dBm
Resolution
10 dB steps with 11 dB vernier
Accuracy
2.5 dB
3.0 dB @ -20 dB attenuator setting
Spectral Purity Harmonics
-30 dBc
Spectral Purity Nonharmonics
-55 dBc
IF Image
-35 dB
Residual FM
< 100 Hz (RMS, 0.3 to 3 kHz BW)
Input Protection
150 W
Frequency Range
0 to ±49.9975 MHz from receive frequency
Resolution
2.5 kHz
Accuracy
See Master Oscillator
Duplex Output Level
-40 dBm (Low), -15 dBm (High) into 50
Input Protection
0.25 W
T/R Port
-85 dBm ±10 dB fixed level
Internal Frequency Modulation Range
0 to 50 kHz (1 kHz tone)
FM Rate
10 Hz to 30 kHz (Internal) 2 Hz to 30 kHz (External) (DC when in variable generate)
FM Accuracy
±5% of reading, ±3% of full scale (1 kHz tone)
FM Distortion
< 1 % (to 20 kHz deviation)
EXT MOD Sensitivity
0.1 VRMS/kHz (- 0% + 30%)
Amplitude Modulation Range
0 to 90%
AM Rate
10 Hz to 10 kHz (30% maximum modulation above 5 kHz)
AM Accuracy
±5% of reading, ±3% of full scale (1 kHz tone)
AM Distortion
< 10% (to 60% modulation)
EXT MOD sensitivity
0.01 VRMS (0% to +30%)
Generator #1 Frequency Range
1 kHz
#1 Accuracy
Same as Master Oscillator
#1 Output Range
0 to 2.5 V (RMS, into 150 Ω)
#1 Distortion
<0.5%
#1 Waveshape
Sine
Audio Generator #2 Frequency Range:
10 Hz to 30 kHz
#2 Resolution
0.1 Hz
#2 Accuracy
±0.01%
#2 Output Range
0 to 2.5 V (RMS, into 150 Ω)
#2 Distortion (at 2.5 VRMS)
<2% (10 Hz to 100 Hz) < 0.7% (100 Hz to 30 kHz)
#2 Waveshapes
Sine, Square, Ramp, Triangle, TTL
Frequency Range
100 kHz to 999.9999 MHz
Resolution
100 Hz
Sensitivity
2 µV typical (1 MHz to 1000 MHz, FM narrow)
Antenna Input Protection
0.25 W
Selectivity
Mode Rx BW AF BW
FM WIDE 200 kHz 80 kHz FM MID 200 kHz 8 kHz FM NAR 15 kHz 8 kHz SSB 6 kHz 8 kHz AM NAR 6 kHz 8 kHz AM NORM 15 kHz 8 kHz
Adjacent Channel Rejection
Rx BW BW >40 dB Down
200 kHz ±300 kHz 15 kHz ±27 kHz 6 kHz ±12 kHz
Demodulation Output
AM Output Level
5 mV RMS/%
FM Output Level
60 mV RMS/1 kHz
Impedance
600
Meter Range
± 30 Hz to ± 10 kHz (full scale, 1-3-10 sequence)
Meter Accuracy
± Master Oscillator, +3% of full scale
Frequency Range
10 Hz to 12 kHz
Meter Range
±3 Hz to ±300 Hz (full scale, decade sequence)
Meter Accuracy
±0.01%, ±3% of full scale
Meter Range
2 kHz to 60 kHz (full scale, 2-6-20 sequence)
Meter Accuracy
±5% of reading, ±3% of full scale (1 kHz tone)
Meter Range
60% and 200% full scale
Meter Accuracy
±5% of reading, ±3% of full scale (1 kHz tone)
Input Level Ranges
0 to 15 W and 0 to 150 W (peak or average responding)
Accuracy
±7% of reading, ±3% of full scale (1 to 600 MHz) ±20% of reading, ±3% of full scale (600 to 1000 MHz)
Operating Conditions
50 W continuous >50 W to 150 W (1 min ON, 5 min OFF)
Range
0 to 20 % at 1 kHz
Accuracy
± 1 % (at 10% distortion)
Signal Frequency
1 kHz
Input Level
0.25 to 2 VRMS
Input Impedance
10 knominal
Range
3 to 20 dB at 1 kHz
Accuracy
± 1 dB (at 12 dB SINAD)
Signal Frequency
1 kHz
Input Level
0.25 to 2 VRMS
Input Impedance
10 knominal
Level Display
10 dB/div
Dynamic Range
70 dB
Log Linearity
±2 dB (-90 to -30 dBm)
Frequency Span Modes
Scan Width RBW
1 MHz/div 30 kHz 500 kHz/div 30 kHz 200 kHz/div 30 kHz 100 kHz/ div 30 kHz 50 kHz/div 30 kHz 20 kHz/div 3 kHz 10 kHz/div 3 kHz 5 kHz/div 3 kHz 2 kHz/div 300 Hz 1 kHz/div 300 Hz
Bandwidth (3 dB)
DC to 1 MHz
Input Ranges
10 mV/div to 10 V/div (decade sequence)
Horizontal Sweep Rate
10 msec/div to 10 µsec/div (decade sequence)
Oscilloscope
Spectrum Analyzer
SINAD Meter
Distortion Meter
RF Power Meter
AM Modulation Meter
FM Deviation Meter
AF Frequency Error Meter
RF Frequency Error Meter
Receiver
Audio Generators
Modulation
Duplex Generator
Output (T/R)
RF Signal Generator
1200 Super S
1200 Super S
2
http://www.ifrinternational.com
1200 Super S
AC VOLTS
Voltage Range
0 to 100 VRMS
Accuracy
10% ± 2 counts
Frequency Range
45 Hz to 10 kHz
DC VOLTS
Voltage Range
0 to 100 V
Accuracy
10% ± 2 counts
TCXO
Temperature Stability
±0.2 ppm (O to 50°C)
Ageing
±0.5 ppm/year
Line Voltage
105 to 130 VAC 210 to 260 VAC
Frequency
50 to 400 Hz
Power Consumption
60 W typical
DC Input
12 to 30 VDC
Dimensions
332 mm (13.06 in) wide, 185 mm (7.3 in) high, 445 mm (17.5 in) deep
Weight
17.2 kg (38 lbs) without options
Stability
0.05 ppm/year (0 to 50°C)
Gain
30 dB (±2 dB) typical, 250 kHz to 1000 kHz
Test Set Output with Analyzer Installed
Variable to +10 dBm, FM and CW Variable to +4 dBm, AM
Frequency Range
1 to 999.9999 MHz
Output Level
Track High -5 dBm (+3/-5 dB) Track Mid -15 dBm (±7 dB) Track Low -40 dBm (+5/-10 dB)
Flatness
±1 dB over center 30% of display ±5 dB over remaining display
Tracking Span
10 kHz to 10 MHz
Output Impedance
50 (nominal)
Spurious
Harmonic and non harmonic are <5 dBc, <10 dB typical Image (RF + 180 MHz) 0 dB typical
Dynamic Range
70 dB
Tracking Range
200 Hz to 1.0 kHz
When ordering please quote the full order number information
Ordering Numbers Versions
1200SS-110 1200 Super S, 110 VAC 1200SS-110-C 1200 Super S, 110 VAC with Certificate of
Calibration 1200SS-220 1200 Super S, 220 VAC operation 1200SS-220-C 1200 Super S, 220 VAC with Certificate of
Calibration 1200SSH-110 1200 Super S Hi Stability (0.05 ppm
OCXO time base, tracking generator) 110
VAC operaation 1200SSH-110-C 1200 Super S Hi Stability, 110 VAC, Cert.
Cal 1200SSH-220 1200 Super S Hi Stability, 220 VAC
operation 1200SSH-220-C 1200 Super S Hi Stability, 220 VAC with
Certificate of Calibration
Accessories
AC0002 Soft padded carrying case AC0488 IEEE-488 (in lieu of RS-232) (not avail.
with 1200SSP or AC0450) AC0489 CLEAR CHANNEL LTR AC510 Paging encoder AC1201 Telescopic antenna AC1205 Microphone AC2200 Maintenance manual AC2201 Rack mounting kit AC4101 Return loss bridge 5 MHz to 1 GHz (req.
1200 Super S Premium) AC5249 Generate Amplifier +30 dBm
Versions and Accessories
Tracking Generator (Premium)
Generate Amplifier (Premium)
0.05 ppm OCXO (Premium)
General Characteristics
Power Requirements
Master Oscillator
Digital Voltmeter
1200 Super S
Wireless - Radio Test Sets
1200 Super S
3
http://www.ifrinternational.com
1200 Super S
Part no. 46891-023
Issue 1
1200 Super S
4
http://www.ifrinternational.com
IFR Americas, Inc., 10200 West York Street, Wichita, Kansas
IFR Americas, Inc., 10200 West York Street, Wichita, Kansas 67215-8999, USA. E-mail: info@ifrsys.com
67215-8999, USA. E-mail: info@ifrsys.com Tel: +1 316 522 4981 Toll Free USA: 1 800 835 2352 Fax: +1 316 522 1360
Tel: +1 316 522 4981 Toll Free USA: 1 800 835 2352 Fax: +1 316 522 1360
As we are always seeking to improve our products, the information in this document gives only a general indication of the product capacity, performance and suitability, none of which shall form part of any
As we are always seeking to improve our products, the information in this document gives only a general indication of the product capacity, performance and suitability, none of which shall form part of any
contract. We reserve the right to make design changes without notice. All trademarks are acknowledged. Parent Company IFR Systems, Inc. © IFR Ltd. 1999.
contract. We reserve the right to make design changes without notice. All trademarks are acknowledged. Parent Company IFR Systems, Inc. © IFR Ltd. 1999.
Tel: +44 (0) 1438 742200 Freephone UK: 0800 282 388 Fax: +44 (0) 1438 727601
Tel: +44 (0) 1438 742200 Freephone UK: 0800 282 388 Fax: +44 (0) 1438 727601
IFR Ltd, Longacres House, Norton Green Road, Stevenage, Herts
IFR Ltd, Longacres House, Norton Green Road, Stevenage, Herts
SG1 2BA, United Kingdom. E-mail: info@ifrinternational.co.uk
SG1 2BA, United Kingdom. E-mail: info@ifrinternational.co.uk
Loading...