Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments
certifies that this instrument has been calibrated
using standards and instruments traceable to
international standards.
We guarantee that at the time of shipping your
instrument has met its published specifications.
An NIST traceable certificate may be
requested at the time of purchase, or obtained
by returning the instrument to our repair and
calibration facility, for a nominal charge.
The recommended calibration interval for this
instrument is 12 months and begins on the date of
receipt by the customer.
Serial #:
Catalog #:
Model #:
Please fill in the appropriate date as indicated:
Date Received:
Date Calibration Due:
________________________________
2150.20 / 2150.21
OX5022-CK / OX5042-CK
_________________________________
_______________________
www.GlobalTestSupply.com
Shipping Contents:
PRODUCT PACKAGING
Handscope Oscilloscope Model OX5022-CK
Handscope Oscilloscope Model OX5042-CK
(1) BNC Adapter
Cat. #5000.49
(1) US Adapter for
the power supply
Cat. #5000.51
(1) of the following:
Cat. #2150.20 / 2150.21
(1) USB Cable + Driver
Cat. #5000.52
(1) Soft Hand-held Carrying Case
Cat. #5000.48
(2) Probe 10:1 600V/BNC-M
Cat. #5000.50
(1) Set of two, color-coded leads,
test probes and clips
Cat. #2152.03
(1) Power Supply 15W, 10-240V, 12V
Also Included:
(1) Test Report
(1) Battery Information Sheet
(6) 1.2V NiMH rechargeable batteries 2700mA/h
Cat. #5000.53
(2) CD-ROMs (software and manual)
CD-ROM CONTENTS: The SX-METRO software and the Handscope’s complete user
manual can be found on the CD-ROMs included with the shipping contents.
www.GlobalTestSupply.com
Precautions Before Use
The operator and/or the responsible authority must carefully read and completely understand the
precautions before use.
If you use this instrument in an unspecified manner, the protection it ensures can be compromised,
thus putting you in danger.
• This instrument is designed for use:
- indoors
- in a level 2 pollution environment
- at an altitude below 2000 m
- at a temperature between 0° C and 40° C
- with a relative humidity of less than 80% up to 35° C.
• The safety of all systems, including the instrument, is the responsibility of the operator.
• It can be used for measurements on 600V CAT III circuits, relative to the ground/earth.
• Before each use, check the condition of the insulation on the cables, boxes, sensors and
accessories. Any element on which the insulation is damaged (even partially) must be taken out
of service for repair or disposal.
• Respect the environmental and storage conditions.
• The external power supply must be connected to the instrument and to the network
(98 to 264 VAC).
• The power supply to the instrument is fitted with an automatically resettable electrical protection
after disappearance of the fault.
• As a safety measure, only use factory supplied parts and accessories.
• It is advised to use individual safety protection whenever the environmental situations in which
the instrument is used require it.
• When handling the sensors or test probes, do not place your fingers beyond the physical guard.
• If the battery housing cover is absent, damaged or incorrectly positioned, the instrument must
not be used other than to adjust the sensors.
Definition of Measurement Categories (CAT)
CAT IV Measurement category IV corresponds to measurements taken at the source of low-voltage
installations.
Example: power feeders, counters and protection devices.
CAT III Measurement category III corresponds to measurements on building installations.
Example: distribution panel, circuit-breakers, machines or fixed industrial devices.
CAT II Measurement category II corresponds to measurements taken on circuits directly connected to
low-voltage installations.
Example: power supply to domestic electrical appliances and portable tools.
Symbols Used
CAUTION! Risk of electric shock. The voltage at the
parts marked with this symbol may be dangerous.
Warning: Risk of danger. Refer to the operating manual to find out the nature of the
potential hazards and the action necessary to avoid such hazards.
Earth/Ground
Dual insulation
The trash can with a line through it means that in the European Union, the product
must undergo selective disposal for the recycling of electric and electronic material, in
compliance with Directive WEEE 2002/96/EC.
The CE marking guarantees conformity with European directives and with regulations
covering EMC.
Application or withdrawal not authorized for non-insulated conductors carrying dangerous voltage levels
www.GlobalTestSupply.com
Power Supply
The oscilloscope is supplied with one external power supply and set of 6 x 1.2V NiMH rechargeable
batteries 2700mA/h.
When the supplied power cord is connected from the instrument to an external power source, battery
power is not needed. The batteries are only used when there is no external power supply available.
Before the first use, start by fully charging the battery.
NOTE: The batteries automatically begin recharging when the Oscilloscope is powered off, but
connected to an external power supply.
When the batteries are recharging, the Battery Charge LED on the front panel will turn on steady.
The LED will blink in the following situations:
• pre-charge of very low batteries
• temperature is too low or too high
• batteries are damaged
When the charge is complete, the LED will turn off.
If the batteries need to be replaced, they must be replaced with NiMH rechargeable batteries. Battery
charge life is guaranteed for same-capacity batteries (in mAh) as those shipped with the oscilloscope.
To remove the battery cover, use a coin to turn the slot on the back of the unit counter-clockwise.
Description
The Handscope Oscilloscope Models OX5022-CK and OX5042-CK combine three instruments into one:
• 20MHz or 40MHz oscilloscope
• Independent 8000-count multimeter with power measurements
• Built-in harmonic analyzer out to the 31st harmonic (fundamental between 40 and 450Hz)
The instrument operates at a constant acquisition depth of 2500 points.
An LCD TFT screen is used to view the applied signals along with all the setting parameters.
The main command functions are accessible using the buttons on the front panel.
A graphic interface is used to:
- adjust the parameters related to the selected button
- navigate using a horizontal main menu showing the current settings and vertical sub-menus
Channel Insulation
The two oscilloscope input channels are insulated from each other and from the ground/earth and the
main power supply block. This insulation is double or reinforced in compliance with the safety standards
IEC 61010-1 and IEC 61010-2-030.
This makes it possible to make measurements on installations or systems connected to the electricity
supply network for voltages of up to 600V in CAT III. The common mode authorized between the two
channels is 600V in CAT III. Thus the operator, the test systems and the environment are completely
protected at all times.
Any voltage (even dangerous) on one channel will not be present on the other channel. The low points
of the inputs are completely insulated, so there is no possibility of the low points looping (which can be
dangerous and highly destructive).
NOTE: The use of accessories with a voltage and/or category lower than 600V CAT III reduces
the operating range to the lower voltages and/or categories.
The oscilloscope is rated 600V CAT III; at least 600V CAT III accessories must be used.
www.GlobalTestSupply.com
Control Features
1
10
2
3
4
5
Measurement Terminals
9
8
7
6
www.GlobalTestSupply.com
ITEMBUTTONDESCRIPTION
OPERATING MODE BUTTONS
1
2
3
4
5
Press these buttons to select the desired operating mode:
- Oscilloscope
- Multimeter
- Harmonic analyzer
NAVIGATION BUTTONS
Use these navigation buttons to move around the menus and dialog boxes:
VERTICAL
- Vertical movement and automatic selection in the secondary menus
- Adjustment of values in the main menus
- Vertical movement in a dialog box
HORIZONTAL
- Horizontal movement through the main menus
- Adjustment of values in the secondary menus
- Horizontal movement in a dialog box
ENTER
- Opens a dialog box from a main menu or a secondary menu
- Validation of the items in a dialog box
3 CHANNEL A, B
- A single press selects channel A (or B) and shows the corresponding menu.
- Pressing twice deselects the channel.
MATH/MEMORY BUTTONS
- A single press selects channel M (Math) and shows the corresponding
menu.
- Pressing twice deselects the channel.
NOTE: For the M (memory) channel, pressing twice invalidates the channel.
Pressing once again selects the Math channel, the memory is lost and must be
reloaded.
ON/OFF BUTTON
- The instrument is turned ON by a short press on this button. It is turned
OFF by a long press (a shutdown message appears and a beep sounds).
FUNCTION BUTTONS
- Auto Set: Performs an automatic adjustment on channels A and B. The
success of each vertical autoset conditions the activation of the channel.
- Run Hold: Starts or stops an acquisition.
6
CHARGE STATUS
- Battery Charge LED
OPTICAL COMMUNICATOR
- Provides the communication between the oscilloscope and a PC.
7
TIME BASE BUTTONS
- increases the time base for acquisition up to 200 s.
8
- decreases the time base for acquisition down to 25 ns.
www.GlobalTestSupply.com
ITEMBUTTONDESCRIPTION
SENSITIVITY BUTTONS
- decreases the vertical sensitivity of the last selected channel down to 5mV.
9
10
- increases the vertical sensitivity of the last selected channel up to 200V.
NOTE: For the M channel, the “sensitivity” buttons vary the amplitude factor
but only if a math channel is validated.
MENU BUTTONS
- displays the main “Trigger” menu
- displays the main “Tools” menu
- displays the main “Acquisition” menu
- displays the main “Memory” menu
- displays the main “Measurement/Cursor” menu
- displays the “Help” window
Use of the Sensors
Distribution of stray capacitors:
Considering the stray capacitances, it is imperative to correctly connect the reference conductors for
each sensor. The conductors should preferably be connected to the cold points to avoid the transmission of noise by the stray capacitance between modes.
The noise of the digital ground (earth) is sent to the analog input by the stray capacitance.
NOTE: In order to prevent electric shocks or possible fires, never use accessories on which the
casing is accessible if it has a voltage of > 30Vrms compared to the ground.
www.GlobalTestSupply.com
Sensor Calibration
To obtain optimum response, the sensor’s low frequency compensation must be adjusted.
NOTE: To carry out this adjustment, the two channels of your oscilloscope must be
disconnected from the measured circuits before opening the battery housing cover.
The calibration output (3Vpp, 1kHz) for the sensors is underneath the battery cover.
To remove the battery cover, use a coin to turn the slot on the back of the unit counter-clockwise.
Connect the sensor to be adjusted
to the calibration output under the
battery housing cover, as shown.
• Select the DC coupling for the channel to which the sensor is connected and run an Autoset
to carry out pre-setting.
• Adjust the sensitivity and the vertical offset of the channel so that the signal fills the screen, and
adjust the time base to 200µs to view a signal period on the screen.
• Turn the BNC base of the sensor in order to access the sensor adjustment screw:
In this example, the sensor is over-compensated:
an overshoot occurs.
Turn the screw in either direction until the signal is
horizontal and looks like the screen shown opposite.
Your sensor is now calibrated.
Turn the BNC base again to close access to the adjustment screw and replace the battery cover.
Remote Programming
The oscilloscope can be programmed remotely from a computer by using the SX-METRO software,
which is located on the CD-ROM supplied with your instrument. This software is used to:
• Configure the instrument
• Perform measurements and retrieve the results
• Transfer files (traces, configuration, screenshots, etc.)
To communicate between the instrument and the computer:
• Connect the USB end of the cable to one of the PC’s USB ports (if necessary install the driver
shipped with the cable).
• Connect the optical connector to the oscilloscope, after first powering it up.
• Open SX-METRO; select USB communications and wait for communication to be established (in
the event of a problem, refer to the SX-METRO instructions).
www.GlobalTestSupply.com
www.GlobalTestSupply.com
Limited Warranty
The Model OX5022 & OX5042 are warranted to the owner for a period of one year from
the date of original purchase against defects in manufacture. This limited warranty is given
by AEMC® Instruments, not by the distributor from whom it was purchased. This warranty
is void if the unit has been tampered with, abused or if the defect is related to service not
performed by AEMC
Full warranty coverage and registration is available on our website:
www.aemc.com/warranty.html.
Please print the online Warranty Coverage Information for your records.
What AEMC® Instruments will do:
If a malfunction occurs within the one-year period, you may return the instrument to us
for repair, provided we have your warranty registration information on file or a proof of
purchase. AEMC
®
Instruments.
®
Instruments will, at its option, repair or replace the faulty material.
Warranty Repairs
What you must do to return an Instrument for Warranty Repair:
First, request a Customer Service Authorization Number (CSA#) by phone or by fax from our
Service Department (see address below), then return the instrument along with the signed
CSA Form. Please write the CSA# on the outside of the shipping container. Return the instrument, postage or shipment pre-paid to:
Ship To:Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments15 Faraday Drive
Dover, NH 03820 USA
Phone: (800) 945-2362 (Ext. 360)
(603) 749-6434 (Ext. 360)
Fax: (603) 742-2346 or (603) 749-6309
E-mail: repair@aemc.com
Caution: To protect yourself against in-transit loss, we recommend you insure your returned
material.
You must obtain a CSA# before returning any instrument.
www.GlobalTestSupply.com
10/13
99-MAN 100382 v2
Chauvin Arnoux
®
, Inc. d.b.a. AEMC® Instruments
15
www.GlobalTestSupply.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.