Aemc instruments 400D-10, 400D-6, 4000D-24, 4000D-14 User Manual

DIGITAL FLEXPROBE
®
400D-6
400D-10 4000D-14 4000D-24
ENGLISH
User Manual
Statement of Compliance
Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments certifies that this instrument has been calibrated using standards and instruments traceable to international standards.
We guarantee that at the time of shipping your instrument has met its published specifications.
An NIST traceable certificate may be requested at the time of purchase, or obtained by returning the instrument to our repair and calibration facility, for a nominal charge.
The recommended calibration interval for this instrument is 12 months and begins on the date of receipt by the customer. For recalibration, please use our calibration services. Refer to our repair and calibration section at www.aemc.com.
Serial #: ________________________________
Catalog #: ______________________________
Model #: ______________________________
Please fill in the appropriate date as indicated:
Date Received: _________________________________
Date Calibration Due:
_______________________
Chauvin Arnoux®, Inc. d.b.a AEMC® Instruments
www.aemc.com
Table of Contents
1. INTRODUCTION ............................................................................... 4
1.1 International Electrical Symbols ................................................5
1.2 DenitionofMeasurementCategories .....................................5
1.3 ReceivingYourShipment ..........................................................6
1.4 OrderingInformation .................................................................6
1.4.1 AccessoriesandReplacementParts ............................6
2. PRODUCT FEATURES ...................................................................... 7
2.1 Description ................................................................................7
2.2 ControlFeatures .......................................................................8
3. OPERATION .................................................................................. 10
3.1 MeasurementPrinciple ...........................................................10
3.2 Use .........................................................................................10
3.2.1 Connection ..................................................................10
3.2.2 Measurement ............................................................. 11
3.2.3 FreezingtheMeasurement ......................................... 11
3.2.4 SearchforMaximum ..................................................12
3.2.5 AutoPowerOFF .........................................................12
3.2.6 LowBattery .................................................................12
3.2.7 Disconnecting .............................................................12
4. SPECIFICATIONS........................................................................... 13
4.1 ReferenceConditions .............................................................13
4.2 Electrical .................................................................................13
4.3 VariationsinRangeofUse .....................................................14
4.4 TypicalFrequencyResponseCurves .....................................15
4.5 PowerSupply ..........................................................................15
4.6 Environmental .........................................................................16
4.7 Mechanical ..............................................................................16
4.8 Safety ......................................................................................16
4.9 ElectromagneticCompatibility ................................................16
2
Digital Flexprobe® Models 400D & 4000D
5. MAINTENANCE ............................................................................. 17
5.1 Cleaning ..................................................................................17
5.2 ReplacingtheBatteries ...........................................................17
5.3 RepairandCalibration ............................................................18
5.4 TechnicalandSalesAssistance ..............................................18
5.5 Limited Warranty .....................................................................19
5.6 WarrantyRepairs ....................................................................19
Digital Flexprobe® Models 400D & 4000D
3
CHAPTER 1

INTRODUCTION

Thank you for purchasing an AEMC® Digital Flexbprobe.
For best results and for your safety, read the enclosed operating instructions carefully and comply with the precautions for use.
PRECAUTIONS BEFORE USE
This instrument is protected against voltages of not more than 1000V with respect to ground in measurement CAT III or 600V in CAT IV between the sensor and the conductor that measures the current.
The protection provided by the instrument may be impaired if the instrument is used other than as specified by the manufacturer.
Do not exceed the rated maximum voltage and current or the measurement category.
Observe the conditions of use; temperature, relative humidity, altitude, level of pollution, and location.
Before each use, check the integrity of the insulation on the sensor, cable and housing. Do not use the instrument if it is open, damaged, poorly assembled, or if its accessories appear damaged.
The sensor must not be applied to or removed from uninsulated conductors at dangerous voltages.
Use personal protection equipment systematically.
All troubleshooting and metrological checks must be
performed by competent and accredited personnel.
4
Digital Flexprobe® Models 400D & 4000D

1.1 International Electrical Symbols

Signifies that the instrument is protected by double or reinforced insulation.
CAUTION - Risk of Danger! Indicates a WARNING and that the operator must refer to the user manual for instructions before operating the instrument in all cases where this symbol is marked.
Must not be applied to or removed from bare conductors at dangerous voltages. Type B current sensor as per IEC 61010‑2‑032.
Important instructions to read and understand completely.
Important information to acknowledge.
Battery.
Compliance with the Low Voltage & Electromagnetic Compatibility European directives (73/23/CEE & 89/336/CEE).
In the European Union, this product is subject to a separate collection system for recycling electrical and electronic components In accordance with directive WEEE 2002/96/EC
1.2 Definition of Measurement Categories
CAT IV:
CAT III:
CAT II: For measurements performed on circuits directly connected to
For measurements performed at the primary electrical supply
(<1000V) such as on primary overcurrent protection devices, ripple control units, or meters.
For measurements performed in the building installation at the
distribution level such as on hardwired equipment in fixed instal­lation and circuit breakers.
the electrical distribution system. Examples are measurements on household appliances or portable tools.
1.3 Receiving Your Shipment
Upon receiving your shipment, make sure that the contents are consis­tent with the packing list. Notify your distributor of any missing items. If the equipment appears to be damaged, file a claim immediately with the carrier and notify your distributor at once, giving a detailed description of any damage. Save the damaged packing container to substantiate your claim.
Digital Flexprobe® Models 400D & 4000D
5

1.4 Ordering Information

Digital FlexProbe® (MiniFlex) Model 400D-6 w/6 ft Lead
(TRMS, 4AAC, 40AAC, 400AAC) ............................................Cat. #2153.30
®
Digital FlexProbe (TRMS, 4A
AC, 40AAC, 400AAC) ............................................Cat. #2153.31
Digital FlexProbe® (MiniFlex) Model 4000D-14 w/6 ft Lead
(TRMS, 40AAC, 400AAC, 4000AAC) ......................................Cat. #2153.32
Digital FlexProbe® (MiniFlex) Model 4000D-24 w/6 ft Lead
(TRMS, 40AAC, 400AAC, 4000AAC) ......................................Cat. #2153.35
All models include one Digital FlexProbe®, two AAA batteries and a product user manual.

1.4.1 Accessories

Multifix Multi-Position Magnetic Mounting Accessory ........Cat. #5000.44
Soft Carrying Case ..............................................................Cat. #2118.65
Small Classic Tool Bag........................................................Cat. #2133.72
(MiniFlex) Model 400D-10 w/6 ft Lead
Order Accessories and Replacement Parts Directly Online
Check our Storefront at www.aemc.com for availability
6
Digital Flexprobe® Models 400D & 4000D
Loading...