AEG EAW3220 User Manual

Type H20 / 60 821 2675 -51
T.D. 07/2003
English
miniCool
INSTRUCTION for USE
ABSORPTION-REFRIGERATOR
2
1.0 INTRODUCTION 3
2.0 FOR YOUR SAFETY 3
2.1 Warnings and Safety Advice 3
2.2 Coolants 3
3.0 WARRANTY AND 3 CUSTOMER SERVICE
4.0 INSTALLATION 4
4.1 The Purpose of this Manual 4
4.2 Tools/Materials Required 4
4.3 Unpacking 4
4.4 Cleaning 4
4.5 Installation 5
4.6 Securing 6
4.7 Connecting the Device to the 6
Electricity Supply
4.8 Changing the Sliding Hinge 7
4.9 Changing the Doorhang 8
5.0 INSTRUCTION FOR USE 9
5.1 Initial Operation 9
5.2 Temperature Control 9
5.3 Automatic Defrost Function 9
5.4 Leakage Detection 9
5.5 Automatic Door Control (ADC) 10
5.6 Interior Light 11
5.7 Environmental Advice 12
5.8 Disposal 12
5.9 Energy saving Tips 12
5.10 Declaration 12
5.11 Check List 13
5.12 Technical Data 14
TABLE OF CONTENTS
INTRODUCTION
You have made an excellent choice by choosing the Dometic miniCool. We are convinced that you will be satisfied with your new appliance in every way. Silent in operation, the miniCool fulfils high quality standards and
guarantees an efficient use of resources and energy during its entire working life, i.e. during manufacturing, use and disposal. Please study the installation and operating instructions carefully before attempting to operate the miniCool.
FOR YOUR SAFETY
Warnings and Safety Advice
In the interests of children's safety:
When disposing of the refrigerator, remove all doors and leave the shelves inside. This prevents children from being accidentally trapped or suffocated in the refrigerator.
Never open the cooling unit - it is under high pressure.
Never store explosive substances, such as lighter fuel, petrol, ether or
similar products in the miniCool.
The minibar is not suitable for the proper storage of medications.
The miniCool must be installed in such a way that accidental contact with
the cooling unit (which heats up when in use) is impossible.
The appliance has to be connected to a properly earthed socket in line
with the relevant valid country regulations.
Servicing must only be carried out by authorised service personnel.
Coolants
Ammonia is used as the coolant. This is a natural compound which is also present in common household cleaners (1 litre of salmiac cleaner contains up to 200g of ammonia - this is roughly double the amount contained in the cooling unit). If a leak occurs (which can be easily detected due to the unpleasant smell):
Switch the device off (pull mains plug, if applicable); Ventilate room thoroughly. Inform hotel personnel.
For the safety of hotel guests and personnel, it has been established by inspectors that the coolant poses no threat to health.
WARRANTY AND CUSTOMER SERVICE
Warranty arrangements are in accordance with EC Directive 44/1999/CE and the normal conditions applicable for the country concerned.
For warranty or service, please contact our customer services section. Spares can be obtained all over Europe from our relevant customer service points. When contacting customer service, please always state model, product and serial number! You can find this information on the model label inside the device.
3
11..00
22..00
2.1
33..00
2.2
e.g.
INSTALLATION
The Purpose of this Manual
The manual shows you how to:
install the miniCool correctly. operate the miniCool correctly. guarantee the miniCool´s correct maintenance and functioning. deal with faults by yourself.
Tools / Materials Required
You will need the following tools for initial operation:
Unpacking
Check during unpacking that the device is defect-free.
Report transport damage to the transport company within 48 hours. Check that the voltage noted on the model label corresponds to the
mains voltage.
Depending on the model, the following parts can be found in the miniCool :
Cleaning
Before operating the miniCool, we recommend you clean it both inside and outside.
Use a soft cloth, lukewarm water and a mild detergent. Following this, wash out the miniCool using clean water and dry
thoroughly.
At annual intervals, remove dust from fridge aggregate using a brush or
soft cloth.
WWAARRNNIINNGG::
To prevent material damage:
Do not use soap or detergents which are harsh, coarse or
which contain soda.
Keep the door seal free from oil and grease. The cylinder locks have been lubricated in the factory to be long-lasting.
4
4.1
4.2
4.4
44..00
4.3
mild detergent
Installation
5
4.5
1. The refrigerator must be level both directions
2. There sould be 20mm clearance to the wall
3. Ventilation must be provided as shown in alternatives A,B,C or D
4. The ventilation duct must at least measure 105mm x the wt
dth of the refrigerator
5. Only
the entire cooling unit must project into
the duct as shown
6 Air passing through the duct must not be
preheated by any source of heat
7. Ventilation grills, if used, must have openings of at least 200cm² each
Please follow the installation details below carefully. Guarantee is valid for products installed as described only.
IMPORTANT:
200 cm²
20 mm
Where a socket outlet is used for the mains connection lead, the outlet must be freely accessible.