AEG DK9390-M, DK9660-AD9, DK9660-M9, DK9160-M, DK9090-M User Manual

...
DK 9160-9190 DK 9360-9390 DK 9660-9690 DK 9960-9990 DK 9090-9060 HC 5690-3360
Dunstabzugshaube
Afzuigkap
Hotte
Cooker Hood
Montage- und Gebrauchsanweisung
Installatie- en gebruiksaanwijzing
Operating and Installation Instructions
Contents
Safety warnings .............................................................................. 67
For the user ...................................................................................... 67
For the installer ................................................................................. 68
Description of the Appliance ......................................................... 69
Description of the Appliance - For DK 9060-9090 only...................... 69
Extraction mode ................................................................................ 69
Recirculation mode ........................................................................... 70
Control Panel .................................................................................. 71
DK 9090 D - 9060 D .......................................................................... 71
DK 9160 D - 9190 D .......................................................................... 71
DK 9360 - DK 9390 - HC 3360 .......................................................... 72
DK 9660 - DK 9690 - HC 5690 .......................................................... 73
DK 9960 - DK 9990 ........................................................................... 74
Grease and charcoal filter maintenance indicator...................... 76
DK 9660 - DK 9690 - DK 9960 - DK 9990 - HC 5690 ......................... 76
Maintenance and Care................................................................... 77
Cleaning the hood ............................................................................. 77
Metal grease filter ............................................................................. 77
Removing the metal grease filter........................................................ 77
Charcoal filter .................................................................................... 78
Changing the light bulb ...................................................................... 79
What to do if ................................................................................... 80
Special accessories ........................................................................ 81
Technical assistance service ......................................................... 81
Technical Details ............................................................................ 83
Mounting accessories included ......................................................... 83
Electrical connection (not for UK) ................................................. 84
Wall unit mounting ............................................................................ 85
66
Safety warnings
For the user
 The cooker hood is designed to extract unpleasant odours from the
kitchen, it will not extract steam.
 Always cover lighted elements, to prevent excess heat from
damaging the appliance. In the case of oil, gas and coal fired cookers it is essential to avoid open flames.
 Also, when frying, keep the deep frying pan on the cooker top/cooker
under careful control.  The hot oil in the frying pan might ignite due to overheating.  The risk of self-ignition increases when the oil being used is dirty.  It is extremely important to note that overheating can cause a fire.  Never carry out any flambé cooking under the hood.Always disconnect the unit from the power supply before
carrying out any work on the hood, including replacing the
light bulb (take the cartridge fuse out of the fuse holder or switch off
the automatic circuit breaker).  It is very important to clean the hood and replace the filter at
the recommended intervals. Failure to do so could cause
grease deposits to build up, resulting in a fire hazard.
 The appliance is not intended for use by young children or infirm
persons without supervision.  Older children must be supervised if using the appliance.  Young children should be supervised to ensure that they do not play
with the appliance.  WARNING - Ensure that the appliance is switched off before
replacing the lamp to avoid the possibility of electric shock.
This appliance is marked according to the European directive 2002/96/ EC on Waste Electrical and Electronic Equipment (WEEE). By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product.
The symbol on the product, or on the documents accompanying the product, indicates that this appliance may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. Disposal must be carried out in accordance with local environmental regulations for waste disposal. For more detailed information about treatment, recovery and recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product.
67
For the installer
 When used as an extractor unit, the hood must be fitted with a
150mm diameter hose (For DK 9060-9090 only: Ø 120mm). Should there already be a pipe of diameter 125 or 120 mm that ducts to the outside through the walls, it is possible to use the 150/125­120 mm reduction flange provided. In this case the hood will be slightly noisier.
When installing the hood, make sure you observe the follow-
ing minimum distance from the top edge of the cooking hob/ ring surfaces: electric cookers 500 mm gas cookers 650 mm
If the instructions for installation for the gas hob specify a greater distance, this must be adhered to.
 The national Standard on fuel-burning systems specifies a maximum
depression of 0.04 mbar in such rooms.
 The air outlet must not be connected to chimney flues or combustion
gas ducts. The air outlet must under no circumstances be connected to ventilation ducts for rooms in which fuel-burning appliances are installed.
 The air outlet installation must comply with the regulations laid down
by the relevant local authorities.
 When the unit is used in extraction mode, a sufficiently large
ventilation hole must be provided, with dimensions that are approxi­mately the same as the outlet hole.
 National and regional building regulations impose a number of
restrictions on using hoods and fuel-burning appliances connected to a chimney, such as coal or oil room-heaters and gas fires, in the same room.
 Hoods can only be used safely with appliances connected to a
chimney if the room and/or flat (air/environment combination) is ventilated from outside using a suitable ventilation hole approximately 500-600 cm2 large to avoid the possibility of a depression being created during operation of the hood.
 If you have any doubts, contact the relevant controlling authority or
building inspectors office.
 Since the rule for rooms with fuel burning appliances is outlet hole of
the same size as the ventilation hole, a hole of 500-600 cm2, which is to say a larger hole, could reduce the performance of the extractor hood.
 If the hood is used in its recirculation mode, it will operate simply
and safely in the above conditions without the need for any of the aforementioned measures.
68
 When the hood is used in its extraction mode, the following rules
must be followed to obtain optimal operation:
- short and straight outlet hose
- keep bends in outlet hose to a minimum
- never install the hoses with an acute angle, they must always follow a gentle curve.
- keep the hose as large as possible (preferably the same diameter as the outlet hole).
- the length should be no more than:
3 metres with one 90° bend 2 metres with two 90° bends Bends of more than 90° will reduce the efficiency of the hood and
reduce the airflow.
 Failure to observe these basic instructions will drastically reduce the
performance and increase the noise levels of the extractor hood.
Description of the Appliance
The cooker hood is designed to extract unpleasant odours
from the kitchen, it will not extract steam.
 The hood is supplied as an extractor unit and can also be used with
a recirculation mode by fitting a charcoal filter.
 In some models the charcoal filter is supplied. The hood, therefore,
can be used immediately in the recirculation mode. We advise removing the charcoal filter to use the hood in the extraction mode.
 For DK 9060-9090 only: The hood is supplied as an extractor unit.
Please disconsider the instructions related to the recycling version, to the installation, use and maintenance of the charcoal filter and of the deflector. The hood is not supplied with an internal motor and must be connected with an exetrnal aspirating motor unit.
Extraction mode
 In this mode fumes are extracted to
the outside via a hose connected to the coupling ring A. Fig. 1.
 In order to obtain the best performan-
ce the hose should have a diameter equal to the outlet hole.
 Should there already be a pipe of
diameter 125 or 120 mm that ducts to the outside through the walls, it is possible to use the 150/125-120 mm Fig. 1
69
reduction flange provided. In this case the hood will be slightly noisier.
 For DK 9060-9090 only: The valve located
inside the discharge hole of the range hood A allows, anyhow, a minimum air exhaustion even when the electric valve switch is in OFF ( O ) position. This is a useful function, since it grants a continuous air exchange inside the kitchen. It is possible to use this function adjusting the valve opening properly. For this purpose it is necessary to change the position of the screws which lock the adjustable closings positioned on the valve surface. Fig 1a.
Fig. 1a
Recirculation mode
 The air is filtered through a charcoal filter and returned to the
kitchen.
 You will need an original charcoal filter for the recirculation mode.
(See Special Accessories).
 Fix the deflector using 2 screws Ø 2,9x13 mm. Fig. 2.  Optionally, the position of the chimney elements can be changed.
When using the hood in the recirculation mode the chimney must be fixed at the top, with the air outlet grill at the side.
70
Fig. 2
Control Panel
 Best results are obtained by using a low speed for normal conditions
and a high speed when odours are more concentrated. Turn the hood on a few minutes before you start cooking. The hood should be left on after cooking for about 15 minutes or until all the odours have disappeared. The control switches are located on the hoods front panel:
DK 9090 D - 9060 D
the light switch switches the hood lamp on and off  the Electr. valve switch serves to open (and close) the electrical
valve so to let air be extracted towards the outside.
Light switch
Electr. valve switch
DK 9160 D - 9190 D
the light switch switches the hood lamp on and off the motor switch switches the motor on and off, enabling you to
select one of the three different speeds.
Light switch
Motor switch
71
DK 9360 - DK 9390 - HC 3360
the light switch switches the hood lamp on and offthe motor switch switches the motor off  Speed 1: Speed 1 push-button  Speed 2: Speed 2 push-button  Speed 3: Speed 3 push-button
Light switch
Motor switch
Speed 1
Speed 3
Speed 2
72