■ Measurement Resolution of 1 µV, 10 fA (SMU220-2), 100 pA (SMU62-20)
■ Source Range ±220 V, ±2 A (SMU220-2, 2.4 W)/±62 V, ±20 A (SMU62-20, 140 W)
■ Minimum Pulse Width 100 µs, Minimum Step 700 µs
R6245/6246
DC Voltage/Current Sources/Monitors
The R6245/6246 Series are DC voltage/current sources and
monitors having source measurement units (SMUs) with 2
isolated channels. The series covers wide source and measurement ranges. It is ideal for measurement of DC characteristics
of items ranging from separate semiconductors such as bipolar
transistors, MOSFETs and GaAsFETs, to ICs and power devices. Further, due to the increased measuring speed and
synchronized 2-channel measurement function, device I/O
characteristics can be measured with precise timing at high
speed which previously difficult to accomplish.
Due to features such as the trigger link function and the
sequence programming function which automatically performs a series of evaluation tests automatically, the new R6245/
6246 enable much more efficient evaluation tests.
(Photo is R6245)
■ High Measurement Accuracy of ±620000 Columns,
0.02%
High Measurement Resolution of 1 mV, 10 fA
■ High source Accuracy of ±62000 Columns, 0.03%
Wide source Range of ±220 V, ±20 A
■ High Throughput, 0.8 V/µs (At Current
Measurement Range of 6 mA or more)
■ Wide Variety of Measurement Functions
• 4 Phenomenon Output (Source/Sink)
• Up to 5 V Remote Sense
• Minimum Step 700 µs Sweep Measurement
(Generation, Measurement, Data Storage)
• Range Switching without Discontinuous Output
• Pulse Measurement with Minimum Pulse Width of
100 µs
• Synchronized 2-Channel Measurement Function
• Search measurement function
Unit Configuration
Model nameChannel AChannel B
R6245SMU220-2SMU220-2
R6246SMU62-20SMU220-2
SMU220-2: 24.2 W max. ±220 V/±2A
SMU62-20: 200 W max. ±62 V/±20A
246
Page 2
DC Voltage/Current Generators/Calibrators
Specifications
All accuracy values are for 23˚C ±5˚C, RH 75% max., guaranteed for 6
months. One-day stability is guaranteed for 23˚C ±5˚C, RH 75% max.
Measurement accuracy, one-day stability and temperature coefficient
are guaranteed with auto zero on, reset time from 1 to 20 PLC.
Maximum output current:
SMU220-2SMU62-20
±2 A up to 12 V±20 A up to 7 V
±0.62 A up to 40 V±10 A up to 20 V
±0.11 A up to 220 V±2.2 A up to 62 V
Maximum output voltage, maximum follow-up voltage:
SMU220-2SMU62-20
±220 V up to 0.11 A±62 V up to 2.2 A
±40 V up to 0.62 A±20 V up to 10 A
±12 V up to 2 A±7 V up to 20 A
Voltage source/measurement range:
Current source/measurement range:
Unit name
SMU62-20
SMU220-2
SMU220-2
SMU62-20
SMU62-20
RangeSource range
600 mV0 to ±620.00 mV10 µV0 to ±620.000 mV1 µV
6 V0 to ±6.2000 V100 µV0 to ±6.20000 V10 µV
60 V0 to ±62.000 V1 mV0 to ±62.0000 V100 µV
200 V0 to ±220.00 V10 mV0 to ±220.000 V1 mV
6 nA0 to ±6.2000 nA100 fA0 to ±6.20000 nA10 fA
60 nA0 to ±62.000 nA1 pA0 to ±62.0000 nA100 fA
600 nA0 to ±620.00 nA10 pA0 to ±620.000 nA1 pA
6 µA0 to ±6.2000 µA100 pA0 to ±6.20000 µA10 pA
60 µA0 to ±62.000 µA1 nA0 to ±62.000 µA100 pA
600 µA0 to ±620.00 µA10 nA0 to ±620.000 µA1 nA
6 mA0 to ±6.2000 mA100 nA0 to ±6.20000 mA10 nA
60 mA0 to ±62.000 mA1 µA0 to ±62.0000 mA100 nA
600 mA0 to ±620.00 mA10 µA0 to ±620.000 mA1 µA
2 A0 to ±2.0000 A100 µA0 to ±2.00000 A10 µA
6 A0 to ±6.2000 A100 µA0 to ±6.20000 A10 µA
20 A0 to ±20.000 A1 mA0 to ±20.0000 A100 µA
SettingMeasurement
resolutionrangeresolution
However, the measurement resolution at a reset time of 100 µs to
500 µs is as follows:
Vo: Follow-up voltage (0 V to ±220 V)
However, for current ranges, ±0.65 pA/˚C is added to the above values
for temperature coefficients of 28˚C to 40˚C.
Integration time: Measurement accuracy of 10 ms to 100 µs, the
following full-scale error is added to one day stability,
Voltage source250 mV + 20 nA x R150 mV
Current source250 mV/R1 + 20 nA100 µA
Voltage source150 mV50 mV
Current source250 mV/R1 + 20 nA50 µA
Voltage measurement150 mV50 mV
Current measurement250 mV/R150 µA
Voltage source150 mV50 mV
Current source50 mV/R1 + 1 nA50 µA
Voltage source200 mV50 mV
Current source80 mV/R1 + 20 nA50 µA
Maximum value (p-p)Typical value (p-p)
0.6 V0.6 V
R1 indicates load resistance (Ω)
Typical values obtained at voltage range 6 V or less, current range 6
mA to 20 A, R1 = 1 kΩ
Settling time: When the current range is 6 mA to 20 A, the time
required to reach ±0.03% of the final value when the output is
changed from zero to full-scale.
For simple resistance load, load capacity 2.5 pF max., compliance
settings at full-scale
ItemFASTSLOW
Voltage generation300 µs2.5 ms
Current generation500 µs5.5 ms
Line regulation: ±0.0017% of range, at AC 100 V ± 10%
Load regulation:
Voltage generation: ±0.0017% of range or less, with 4-wire
connection at maximum load
Current generation: ±5 ppm x Vo/1V or less, Vo: follow-up voltage
(0 V to ± 220 V)
Output resistance: With 2-wire connection, excluding output
cable
Maximum capacity load: Maximum non-oscillating capacity load
when voltage generation or voltage compliance is operating
Current rangeMaximum load capacity
6 nA1 kΩ3.22 E + 13 Ω0.01 µF
60 nA100 Ω3.22 E + 12 Ω0.01 µF
600 nA10 Ω3.22 E + 11 Ω0.01 µF
6 µA1 Ω3.22 E + 10 Ω0.01 µF
60 µA200 mΩ3.22 E + 9 Ω0.1 µF
600 µA100 mΩ3.22 E + 8 Ω1 µF
6 mA100 mΩ3.22 E + 7 Ω10 µF
60 mA100 mΩ3.22 E + 6 Ω100 µF
600 mA100 mΩ3.22 E + 5 Ω1000 µF
2 A, 6 A100 mΩ1 E + 5 Ω1000 µF
20 A100 mΩ1 E + 4 Ω1000 µF
Output resistance
Voltage sourceCurrent source
Standard accessory cable (A01010) resistance: 0.2 Ω max.
Maximum inductive load: Maximum non-oscillating inductive load
when voltage generation or voltage compliance is operating
Current source/compliance rangeMaximum inductive load
6 nA to 60 µA50 µH
600 µA300 µH
6 mA500 µH
60 mA to 20 A1000 µH
CMRR: With 1 kΩ unbalanced impedance between LO and GUARD
terminals, DC and AC 50/60 Hz ± 0.09%
Item
Voltage measurement60 dB120 dB
Current measurement0.01%/1 V1 ppm/1 V
100 µs to 10 ms1 PLC to 20 PLC
Reset time
NMRR: At AC 50/60 Hz ± 0.09%
Item
Voltage measurement0 dB60 dB
Current measurement0 dB60 dB
100 µs to 10 ms1 PLC to 20 PLC
Reset time
External measurement input: When the current range is measuring
an applied voltage at the MEASURE INPUT terminal, the
measured voltage is displayed in the set current range
Voltage measurement accuracy ±(0.02% of reading + 120 µV)*1
Current display accuracy ±(0.375% of reading + 7.6 µA)*2
Maximum allowable applied voltage ±250 V peak max.
External analog input: When an external analog signal is added
from the ANALOG INPUT terminal, the output added to the
generation value of the set generation range can be obtained. 2
types of gain can be selected. Input and output ranges are decided
by the source range.
Voltage source accuracy ±(0.16% of setting + 3.8 mV)*1
Current source accuracy ±(0.5% of setting + 10 µA)*2
Maximum input frequency FAST: 10 kHz, SLOW: 1 kHz, at ±6 V
output voltage, 6 mA to 6 A current range, full-scale
Maximum allowable applied voltage ±10 V peak max.
Input resistance Approx. 10 M Ω
V monitor: Voltage between the HI SENSE and LO SENSE terminals
divided at ±6.2 V full-scale is output at V MONITOR terminal
channel A and B generation and measurement of DC, pulse and sweep
Search Measurement :Binary search measurement. Linear search
measurement.
Programming functions : Sequence programming function.
All the above functions can be programmed.
Max. programs: 128 characters × 100 programs
High-speed sequence programming function.
Up to 20 items of DC measurement, pulse measurement, binary/
linear search measurement, time parameter, 16-bit digital output
data, and conditional jumps can be programmed.
Results (Lo, Go, Hi, etc.) are output from the handler interface.
* Search measurement and programming set via GPIB only.
Generation data memory capacity: 2,048 data items/channel (when
random or random pulse is used)
Measurement data memory capacity: 2,048 data items/channel
Trigger methods: Measurement or generation can be done with
autotrigger (free-run) and external trigger
Output methods: Bipolar, floating & guarded
Output terminals: Tri-axial/binding post *1
Output types: HI OUTPUT, HI SENSE, LO OUTPUT, LO SENSE,
DRIVING GUARD (DG), GUARD
Maximum applied voltage between terminals:
Between HI and LO; 225 Vp-p max. (SMU220-2)/65 Vp-p max. (SMU62-20)
Between LO and GUARD; 50 Vp-p max.
Between GUARD and outer casing; 500 Vp-p max.
Maximum remote sensing voltage: ±5 V max. *2
Voltage measurement input resistance: 3.22 × 1013 Ω min.
(SMU220-2)/3.22 × 109 Ω min. (SMU62-20)
Voltage input leakage current: ±5 pA/±1 nA max. *3
Guard offset voltage: ±3 mV max.
Maximum allowable card capacity: 1000 PF max. *4
Maximum allowable shield capacity: 5000 PF max. *5
*1: SMU220-2/SMU62-20
*2:
Voltage between the HI OUTPUT and HI SENSE terminals, between the
LO OUTPUT and LO SENSE terminals and between the HI SENSE and
LO SENSE terminals are within the range of the maximum output voltage.
Includes voltage drop due to cable resistance.
*3:
When doing ISVM measurement at current generation range of 6 nA/60 µA
*4: Between HI (OUTPUT or SENSE) and DG terminals
*5: Between DG and LO (OUTPUT or SENSE) terminals
GPIB interface: IEEE standard, conforms with 488-1978
SH1, AH1, T6, L4, SR1, RL1, PP0, DC1, DT1, C0, E2
Digital output: Internal status or 16 bit setting output
5 V pull-up with 10 kΩ resistance at O/C
Trigger link: Used for synchronizing 2 units of the R6245/6246
Series for generation or measurement. TTL level I/O.
Scanner control: For use in scanner control with ADVANTEST
R7210 or other models. TTL level output.
Trigger input: Used at measurement start, sweep step up, pulse
output trigger. TTL negative pulse 10 ms min.
Trigger output: Used at measurement end, sweep end. Output TTL
negative pulse approx. 15 ms
Interlock input: Used when outputting by interlocking with a fixture
Setting Times
Hold time setting range:
Setting rangeResolutionSetting accuracy
100 ms to 65.5350 s100 µs± (2% + 40 µs)
Measure delay time setting range:
Setting rangeResolutionSetting accuracy
100 µs to 65.53500 s10 µs±(2% + 40 µs)
Pulse width, pulse period setting range:
Pulse period (Tp)Pulse width (Tw)*Resolution
700 µs to 655.35 ms100 µs to 655.35 ms10 µs
655.4 ms to 6.5535 s100 µs to 6.5535 s100 µs
6.554 s to 65.535 s1 ms to 65.535 s1 ms
* The pulse width resolution is always the same as the pulse period, so the possible setting
range for the pulse width is decided by the pulse period setting.
R6245/6246 Fluorescent display CRT and LED display
R6245A LED display only (POWER, ON, FAILED, CH COMMON
SHORT, OPERATE, 4 WIRE, LO-G SHORT)
Setting method:
R6245/6246 By keys, GPIB remote
R6245A By GPIB remote only
Preheating time: 30 minutes or more until specified accuracy is
attained
Operating conditions: 0˚C to 40˚C, 85% RH
Storage conditions: -25˚C to +70˚C
Power requirements: Specify at time of ordering
Option no.StandardOption 32Option 42Option 44
Power voltage90 V to 110 V108 V to 132 V198 V to 242 V216 V to 250 V
Power frequency: 48 Hz to 66 Hz
Power consumption: 350 VA (R6245/6245A)/850 VA max. (R6246)
Dimensions: Approx. 424 (W) × 177 (H) × 500 (R6245/
6245A)/550 (R6246) (D) mm
Mass: 25 kg max. (R6245/6245A)/33 kg max. (R6246)
Accessories:
ItemModelStock no.R6245/6245AR6246
Power Cable
Input/Output CableA01010DCB-FM1645 × 0121
A01402DCB-DD2428 × 0110
A01437DCB-DD5641 × 0101
Accessories (Sold Separately)
PR624501-FJ Semiconductor Parameter Auto Measurement
Software
R12701Test Fixture
A01009-050Input/Output Cable (0.5 m)
A01009-100Input/Output Cable (1 m)
A01009-150Input/Output Cable (1.5 m)
A01009-200Input/Output Cable (2 m)
A01010Input Cable (1 m)
A01038Input/Output Cable (for R6246 channel A)
A02710Rack Mount Set A (EIA standard, with front handle)
A02711Rack Mount Set A (JIS standard, with front handle)
A02720Rack Mount Set B (EIA standard, without front
handle)
A02721Rack Mount Set B (JIS standard, without front
handle)
A02703Front Handle Set
A02730Rack Flange Set A (EIA standard)
A02731Rack Flange Set A (JIS standard)
A02615Slide Rail Set
249
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.