Advanced Energy ARTESYN INTELLIGENT MP User Manual

ARTESYN INTELLIGENT MP SERIES
Up to 1500 Watts
Advanced Energy's Artesyn iMP1 series is an AC input to DC output configurable power system consisting of a microprocessor-controlled PFC front end providing seven slots that accept intelligent DC-DC converter modules with single, dual or triple outputs ranging from 2 V to 60 V. Single output modules come in four power ranges that can be mixed and matched and connected in parallel or series to obtain thousands of output combinations customized to any application.
SPECIAL FEATURES
Full medical EN60601 approval
Intelligent I
Voltage adjustment on all outputs (manual or I
Configurable input and output OK signals and indicators
Configurable inhibit/enable
Configurable output UP/DOWN sequencing
Configurable current limit (foldback or constant current)
High power density (8.8 W/cu-in)
Intelligent fan (speed control/fault status)
Downloadable GUI from website
Customer provided air option
uP controlled PFC input with active inrush protection
2
I
C monitor of voltage, current, and
temp
Programmable voltage, current limit, inhibit/enable through I
2
C control
2
C)
2
C
Optional extended hold-up module (SEMI F47 compliance)
Increased power density to 50% over standard MP
External switching frequency sync input
Optional conformal coating
Industrial temp range (-40 ºC to 70 ºC)
No preload required
Industrial shock/vibration (> 50G’s)
SAFETY
UL UL60950/UL2601**
CSA CSA22.2 No. 234 Level 5
TUV EN60950/EN60601-1**
BABT Compliance to EN60950/ EN60601 BS7002
CB Certificate and report
CE Mark to LVD
DATA SHEET
Total Power:
Up to 1500 W
Input Voltage:
85 - 264 Vac
# of Outputs:
Up to 21
©2020 Advanced Energy Industries, Inc.
IMP
ELECTRICAL SPECIFICATIONS
Input
Input ra nge 85 - 264 Vac; 120 - 300 Vdc
(limited to 300 Vdc in medical applications)
Frequency 47 - 63 Hz (iMP1 47 - 440 Hz)
Inrush current 40 A peak maximum (soft start)
Efficiency Up to 85% @ full case load
Power Factor 0.99 typ. meets EN61000-3-2 (n/a @ 440 Hz)
Turn-on time AC on 2.0 sec typ., inhibit/enable 150 ms typical
Programmable delay; 50 ms internal turn-on delay (Dual Output only)
EMI filter CISPR 22/EN55022 Level “B”**
Leakage current 300 µA max. @ 240 Vac; 47 - 63 Hz
Radiated EMI CISPR 22/EN55022 Level “B”**
Holdover storage 20 ms minimum (independent of input Vac) additional 34 ms holdover
storage with optional HUP module (SEMI F47 compatible). For iMP4 15 ms (low-line), 10 ms (high-line)
AC OK > 5 ms early warning min. before outputs lose regulation
Full cycle ride thru (50 Hz) (n/a on iMP4 > 750 W @ 90 Vac)
Harmonic distortion Meets EN61000-3-2
Isolation Meets EN60950 and EN60601
Input to output: 4000 Vac; input to ground: 1500 Vac; output to ground: 400 Vdc Meets 1 MOPP Primary to ground, 2 MOPP Primary to Secondary
Global inhibit / enable TTL, Logic “1” and Logic “0”; configurable
Input fuse (internal) iMP4: 16 A; iMP8: 20 A; iMP1: 25 A (both lines fused)
Warranty 2 years
2 advancedenergy.com
ELECTRICAL SPECIFICATIONS (CONTINUED)
Output
Adjustment range* ± 10% minimum all outputs (manual)
(full module adjustment range using I
Factory set point accuracy 1%
2
I
C output program accuracy ± 5%
Margining ± 4 - 6% nominal analog (single output module only)
Overall regulation 0.4% or 20 mV max. (1500 W modules 1% max.) (36 W modules 4% maximum)
Ripple RMS: 0.1% or 10 mV, whichever is greater Pk-Pk: 1.0% or 50 mV, whichever is greater Bandwidth limited to
20 MHz
Dynamic response < 2% or 100 mV, with 25% load step
Recovery time To within 1% in < 300 µsec
Overcurrent protection** Configurable through I
2
C (calibration required). Single output module and main output of the dual output module
105 - 120% of rated output current. Aux output of dual output module 105 - 140% of rated output current
Short-circuit protection Protected for continuous short-circuit.
Recovery is automatic upon removal of short
2
Overvoltage protection* Configurable through I
C
Single output module: 2 - 5.5 V 122 - 134%; 6 - 60 V 110 - 120%
Dual output module: 2 - 6 V 122 - 134%; 8 - 28 V 110 - 120%
Triple output module: 110 - 120% of highest voltage rating
Output (cont.)
Reverse voltage protection 100% of rated output current
Thermal protection* (OTP and OTW)
Configurable through I All outputs disabled when internal temp exceeds safe operating range. > 5 ms warning (AC OK signal) before
2
C
shutdown
Remote sense Up to 0.5 V total drop (not available on triple output module)
Single wire parallel Current share to within 2% of total rated current
DC OK* ± 5% of nominal. Configurable through I
Minimum load Not required
Housekeeping bias voltage 5 Vdc @ 1.0 A max. present whenever AC input is applied (Optional 2.0 A available)
Module inhibit* Configured and controlled through I
Switching frequency 250k Hz accepts external sync signal
Output/Output isolation > 1 Megohm, 500 V
External sync TTL clock input signal used to adjust switching frequency. Frequency 500 kHz
± 20%; Duty cycle 40 - 55%
* Can be c ontrol led via I2C ** Contro lled via I
2
C but requ ires loa d calibration
2
C)
2
C
2
C
IMP
INTERNAL PART NUMBER REFERENCE TABLE
Part # Where X = Description Module Code
73-580-0001i N/A iMP8 Case iMP8
73-690-0001i N/A iMP1 Case iMP1
73-540-0001i N/A iMP4 Case iMP4
advancedenergy.com 3
IMP
ENVIRONMENTAL SPECIFICATIONS
Operating temperature -40 ° to 70 °C ambient. Derate each output 2.5% per degree from 50 ° to 70 °C. (-20 °C start up)
Storage temperature -40 °C to +85 °C
Electromagnetic susceptibility Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3
Humidity Operating; non-condensing 10% to 95% RH
Vibratio IEC68-2-6 to the levels of IEC721-3-2
MTBF demonstrated > 550,000 hours at full load, 220 Vac and 25 °C ambient conditions
OUTPUT MODULE LINE-UP
Module Code 1 2 3 5 4
Module Type Single Single Single Single Dual Triple
Max output power 210 W 360 W 750 W 1500 W 144 W 36 W
Max output current 35 A 60 A 150 A 140 A 10 A 2 A
Output voltages available* 2 - 60 V 2 - 60 V 2 - 60 V 6 - 60 V 8 - 15*, 24 - 28; 8 - 15*, 8 - 15*;
8 - 15*, 2 - 6; 2 - 6, 2 - 6; 24 - 28,
24 - 28; 24 - 28, 2 - 6
Standard voltage increments 25 25 25 18 16 18
Remote sense Yes Yes Ye s Ye s Yes Yes No
Remote margin Yes Yes Yes Yes No No No
V-Program - I
Active Current Share Yes Yes Ye s Ye s Ye s No No
Module Inhibit - I
Module Inhibit - Analog Ye s Ye s Yes Yes Ye s No No
Overvoltage/Overcurrent protection
Minimum load required No No No No No No No
Slots occupied in any iVS case 1 2 3 4 1 1
* Note: Conta ct Factory for ex tende d range dow n to 6 V
2
C Control Yes Yes Yes Yes Yes Ye s No
2
C Control Ye s Ye s Ye s Yes Ye s Yes Yes
Yes Yes Yes Yes Yes Ye s Yes
8-15, 8-15, 2-6; 8-15, 8-15, 8-15;
8-15, 8-15, 18-28; 8-15, 18-28,
2-6
4 advancedenergy.com
OUTPUT MODULE VOLTAGE/CURRENT*
IMP
Voltage
Voltage
Code
Single Output Module Code Dual Output*** Triple Output
1 2 3 5 4 4 - - -
Adjustment
Ranges****
2 V A 35 A 60 A 150 A 300 A 10 A 10 A 2 A 1.8 - 2.2
2.2 V B 35 A 60 A 150 A 300 A 10 A 10 A 2 A 2.0 - 2.4
3 V C 35 A 60 A 150 A 300 A 10 A 10 A 2 A 2.7 - 3.3
3.3 V D 35 A 60 A 150 A 300 A 10 A 10 A 2 A 3.0 - 3.6
5 V E 35 A 60 A 150 A 300 A 10 A 10 A 2 A 4.5 - 5.5
5.2 V F 35 A 60 A 144 A 288 A 10 A 10 A 2 A 4.7 - 5.7
5.5 V G 34 A 58 A 136 A 273 A 10 A 10 A 2 A 5.0 - 6.1
6.0 V H 23 A 42 A 97.5 A 250 A 10 A* 10 A* 2 A 5.4 - 6.6
8.0 V I 20 A 36 A 84.4 A 187.5 A 10 A 4 A 1 A 1 A 1 A 7.2 - 8.8
10 V J 18 A 32 A 75 A 140 A 10 A 4 A 1 A 1 A 1 A 9.0 - 11.0
11 V K 17 A 31 A 68 A 136.3 A 10 A 4 A 1 A 1 A 1 A 9.9 - 12.1
12 V L 17 A 30 A 62.5 A 125 A 10 A 4 A 1 A 1 A 1 A 10.8 - 13.2
14 V M 14 A 21 A 53.5 A 107 A 9 A 4 A 1 A 1 A 1 A 12.6 - 15.4
15 V N 14 A 20 A 50 A 100 A 8 A 4 A 1 A 1 A 1 A 13.5 - 16.5
18 V O 11 A 19 A 41.6 A 83.3 A 0.5 A 0.5 A 16.2 - 19.8
20 V P 10.5 A 18 A 37.5 A 75 A 0.5 A 0.5 A 18.0 - 22.0
24 V Q 8.5 A 15 A 30 A 62.5 A 4 A 2 A 0.5 A 0.5 A 21.6 - 26.4
28 V R 6.7 A 11 A 26.8 A 53.5 A 3 A 2 A 0.5 A 0.5 A 25.2 - 30.8
30 V S 6.5 A 11 A 25 A 50 A 27.0 - 33.0
33 V T 6.2 A 10.9 A 22.7 A 35.8 A 29.7 - 36.3
36 V U 5.8 A 10 A 20.8 A 35.8 A 32.4 - 39.6
42 V V 4.2 A 7.5 A 16 A 35.7 A 37.8 - 46.2
48 V W 4.0 A 7.5 A 15.6 A 31.2 A 43.2 - 52.8
54 V X 3.7 A 6.0 A 13.9 A 27.7 A 48.6 - 59.4
60 V Y 3.5 A 6.0 A 12.5 A 25 A 54.0 - 66.0
Contact Factory
Special* Z 35 A 60 A 150 A 300 A 10 A 2.3 - 2.6
Special* Z 35 A 60 A 150 A 300 A 10 A 3.7 - 4.4
Special* Z 20 A 36 A 80 A 140 A 8 A 6.7 - 7.1
* Note: Co ntact F actor y for exte nded ran ge down to 6 V. ** Increments o f current not shown c an be achieved by paralleli ng modul es (add curre nts of each module s elect ed). *** Total o utput p ower on dua l model mu st not exce ed 144 W. *** * For sing le output modul es only. Green reference lines indicate physical module groupings
2
C
I
advancedenergy.com 5
Loading...
+ 10 hidden pages