ADTRAN TRACER 1280050L1 User Manual

For more detailed documentation, visit us online at www.adtran.com
Quick Start Guide
TRACER ETHERNET SWITCH MODULE P/N 1280050L1
INSTALLATION INSTRUCTIONS
The TRACER Ethernet Switch Module is not hot-swappable. Remove power from the TRACER system before installing or removing the module.
1. Remove the cover plate from the appropriate option slot in the TRACER rear panel.
2. Slide the TRACER Ethernet Switch Module into the option slot until the module is firmly positioned in the chassis.
3. Secure the thumbscrews at both edges of the module. Tighten with a screwdriver.
4. Connect the cables to the associated device(s).
5. Complete installation of remaining modules and system as specified in the TRACER 6000 Series System Manual.
NETWORK CONNECTION PINOUT
Pin Name Source Description
1 RX1 Attached Equipment Receive Positive 2 RX2 Attached Equipment Receive Negative 3 TX1 Module Transmit Positive 4, 5 UNUSED N/A — 6 TX2 Module Transmit Negative 7, 8 UNUSED N/A
Quick Start Guide, 61280050L1-13A, January 2005 Technical Support 1-888-4ADTRAN (1-888-423-8726) Copyright © 2005 ADTRAN, All Rights Reserved
SPECIFICATIONS
Interface Type: (4) 10BaseT/100BaseTX interfaces with auto MDI/MDIX
crossover on all interfaces
Flow Control: Back-pressure flow control on all half-duplex interfaces
Environmental Specifications:
Compliance: FCC Part 15, Class A
Operating Temperature: -25°C to 65°C Storage Temperature: -20°C to 70°C Relative Humidity: Up to 95% non-condensing