Adtran NV402E1 User Manual

NetVanta 1000 Series and
NetVanta 1000R Series
Hardware Installation Guide
1200500E1/L1 NetVanta 1224 1200504E1/L1 NetVanta 1224ST 1200510L1 NetVanta 1224STR (AC) 1200520E1/L1 NetVanta 1224R 1200530L1 NetVanta 1224R PoE 1200560E2/L2 NetVanta 1524ST 1200570L1 NetVanta 1224STR PoE 1200580L1 NetVanta 1224 PoE 1200584L1 NetVanta 1224ST PoE 1200590L1 NetVanta 1224STR (DC) 1700515E2 NetVanta 1335 1700515E12 NetVanta 1335 WiFi 1700525E2 NetVanta 1335 PoE 1700525E12 NetVanta 1335 WiFi PoE 4200368L1 Enhanced Feature Pack (Hardware and Software) for IPSec VPN Upgrade for
NetVanta 1224STR (AC/DC), 1224R, 1224R PoE, and 1224STR PoE 1200861L1 NetVanta 56K/64K Network Interface Module 1200862L2#NEBS NetVanta T1/FT1 NEBS Network Interface Module 1202862L1 NetVanta T1/FT1 Network Interface Module 1202863L1 NetVanta T1/FT1 + DSX-1 Network Interface Module 1200872L1 NetVanta Dual T1 Network Interface Module 1200868E1/L1 NetVanta E1/FE1 Network Interface Module 1200878E1/L1 NetVanta E1/FE1 + G.703 Drop Network Interface Module 1200866E1/L1 NetVanta Serial Network Interface Module 1200867L1 NetVanta SHDSL Network Interface Module 1200869E1/L1 NetVanta ADSL Network Interface Module, Annex A 1200889E1/L1 NetVanta ADSL Network Interface Module, Annex B 1200864L1 NetVanta Analog Modem Dial Backup Interface Module 1200865L1 NetVanta ISDN BRI Dial Backup Interface Module 1200875L1 NetVanta ISDN S/T Dial Backup Interface Module 1200886L1 NetVanta Serial Dial Backup Interface Module 1200480L1 1000BaseSX Multi-Mode SFP Module 1200481L1 1000BaseLX Single-Mode SFP Module 1200816E1, 817E1, 818E1, 819E1
CompactFlash
®
, 128, 256, 512, and 1024 MB, respectively (NetVanta 1335 only)
61200500L1-34L March 2007
Trademarks NetVanta 1000/1000R Series Hardware Installation Guide
Trademarks
Any brand names and product names included in this manual are trademarks, registered trademarks, or trade names of their respective holders.
To the Holder of the Manual
The contents of this manual are current as of th e date of publication. ADTRAN reserves the right to change the contents without prior notice.
In no event will ADTRAN be liable for any special, incidental, or consequential damages or for commercial losses even if ADTRAN has been advised thereof as a result of issue of this publication.
Software Licensing Agreement
Each ADTRAN product contains a single license for ADTRAN supplied software. Pursuant to the Licensing Agreement, you may: (a) use the software on the purchased ADTRAN device only and (b) keep a copy of the software for backup purposes. This Agreement covers all software installed on the system as well as any software available on the ADTRAN website. In addition, certain ADTRAN systems may contain additional conditions for obtaining software upgrades.
Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
901 Explorer Boulevard
P.O. Box 140000
Huntsville, AL 35814-4000
Phone: (256) 963-8000
Copyright © 2007 ADTRAN, Inc.
All Rights Reserved.
Printed in U.S.A.
2 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L
NetVanta 1000/1000R Series Hardware Installation Guide Conventions
Conventions
Notes provide additional useful information.
Cautions signify information that could prevent service interruption or damage to the equipment.
Warnings provide information that could prevent injury or endangerment to human life.
61200500L1-34L Copyright © 2007 ADTRAN, Inc. 3
Safety Instructions NetVanta 1000/1000R Series Hardware Installation Guide
Safety Instructions
When using your telephone equipment, please follow these basic safety precautions to reduce the risk of fire, electrical shock, or personal injury:
1. Do not use this product near water, such as a bathtub, wash bowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool.
2. Avoid using a telephone (other than a cordless-type) during an electrical storm. There is a remote risk of shock from lightning.
3. Do not use the telephone to report a gas leak in the vicinity of the leak.
4. Use only the power cord, power supply, and/or batteries indicated in the manual. Do not dispose of batteries in a fire. They may explode. Check with local codes for special disposal instructions.
5. The socket-outlet shall be installed near the equipment and shall be easily accessible.
This equipment incorporates double pole/neutral fusing. If the neutral fuse opens and the line fuse does not open, voltage could still be present in the unit.
Additional safety guidelines, such as Waste Electrical And Electronic Equipment (WEEE) are given in the NetVanta Safety and Regulatory Information document on the ADTRAN OS System Documentation CD .
Save These Important Safety Instructions
4 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L
NetVanta 1000/1000R Series Hardware Installation Guide FCC-Required Information
FCC-Required Information
FCC regulations require that the following information be provided in this manual:
1. This equipment complies with Part 68 of FCC rules and requirements adopted by ACTA. Each registered interface has a label that contains, among other information, a product identifier in the format US:AAAEQ##TXXXX. If requested, provide this information to the telephone company.
2. If this equipment causes harm to the telephone network, the telephone company may temporarily discontinue service. If possible, advance notification is given; otherwise, notification is given as soon as possible. The telephone company will advise the customer of the right to file a complaint with the FCC.
3. The telephone company may make changes in its facilities, equipment, operations, or procedures that could effect the proper operation of this equipment. Advance notification and the opportunity to maintain uninterrupted service are given.
4. If experiencing difficulty with this equipment, please contact ADTRAN for repair and warranty information. The telephone company may require this equipment to be disconnected from the network until the problem is corrected or it is certain the equipment is not malfunctioning.
5. This unit contains no user-serviceable parts.
6. This equipment is designed to connect to the telephone network or premises wiring using an FCC-compatible modular jack, which is compliant with Part 68 and requirements adopted by ACTA.
7. The following information may be required when applying to the local telephone company for leased line facilities:
Registration
Part Number
1200861L1 US:HDCDENAN1200861L1 1202862L1
1202863L1 1200872L1 US: HDCDENAN1200872L1
1200864L1 US: HDCMM04A1200864L1 Analog Loop Start 0.4A/9.0Y 02LS2 RJ-11C 1200865L1 US: HDCDENAN1200865L1 Basic Rate ISDN 6.0F 02LS5 RJ-49C 1200869E1 US: HDCDL01A1200869L1 ADSL Modem 0.1A Metallic RJ-11C
US: HDCDENAN1202863L1
Number Service Type REN/SOC FIC USOC
56 Kbps Digital Interface 64 Kbps Digital Interface
1.544 Mbps - SF
1.544 Mbps - SF and B8ZS
1.544 Mbps - ESF
1.544 Mbps - ESF and B8ZS
6.0F
6.0N
04DU5-56 04DU5-64
04DU9-BN
04DU9-DN 04DU9-1KN 04DU9-1SN
RJ-48S
RJ-48C
8. The REN is useful in determining the quantity of devices you may connect to your telephone line and still have all of those devices ring when your number is called. In most areas, the sum of the RENs of all devices should not exceed five. To be certain of the number of devices you may connect to your line as determined by the REN, call your telephone company to determine the maximum REN for your calling area.
9. This equipment may not be used on coin service provided by the telephone company. Connection to party lines is subject to state tariffs. Contact your state public utility commission or corporation commission for information.
61200500L1-34L Copyright © 2007 ADTRAN, Inc. 5
FCC Radio Frequency Interference Statement NetVanta 1000/1000R Series Hardware Installation Guide
FCC Radio Frequency Interference Statement
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio frequencies. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Electromagnetic Compatibility (EMC) Table
NetVanta Module P/N and Name NetVanta 1224STR (AC) / 1200861L1 56K/64K NIM FCC Part 15, Class A 1200862L2#NEBS T1/FT1 NEBS NIM N/A FCC Part 15, Class A,
1202862L1 1202863L1 1200872L1
1200868E1/L1 1200878E1/L1
1200866E1/L1 Serial NIM FCC Part 15, Class A
1200867L1 SHDSL NIM FCC Part 15, Class A
1200869E1 1200889E1
1200864L1 1200865L1 1200875L1 1200886L1
1202368L1 VPN Accelerator Card
T1/FT1 NIM T1/FT1 + DSX-1 NIM Dual T1 NIM
E1/FE1 NIM E1/FE1 + G.703 Drop
ADSL NIM, Annex A ADSL NIM, Annex B
Analog Modem DIM ISDN BRI DIM ISDN S/T DIM Serial DIM
(included in P/N 4200368L1)
1224R EN 55022 Class A
FCC Part 15, Class A EN 55022 Class A
FCC Part 15, Class A EN 55022 Class A EN 55024 EN 61000-3-2 EN 61000-3-3
EN 55022 Class A EN 55024 EN 61000-3-2 EN 61000-3-3
EN 55022 Class A EN 55024 EN 61000-3-2 EN 61000-3-3
FCC Part 15, Class A EN 55022 Class A EN 55024 EN 61000-3-2 EN 61000-3-3
FCC Part 15, Class A EN 55022 Class A EN 55024 EN 61000-3-2 EN 61000-3-3
FCC Part 15, Class A EN 55022 Class A EN 55024 EN 61000-3-2 EN 61000-3-3
NetVanta 1224STR (DC) NetVanta 1335 N/A FCC Part 15, Class A
EN 55022 Class A GR-1089-CORE, Sections 2 and 3
N/A FCC Part 15, Class A
N/A FCC Part 15, Class A
N/A FCC Part 15, Class A
N/A FCC Part 15, Class A
N/A FCC Part 15, Class A
N/A FCC Part 15, Class A
N/A FCC Part 15, Class A
EN 55022 Class A N/A
EN 55022 Class A
EN 55022 Class A EN 55024 EN 61000-3-2 EN 61000-3-3
EN 55022 Class A EN 55024 EN 61000-3-2 EN 61000-3-3
EN 55022 Class A EN 55024 EN 61000-3-2 EN 61000-3-3
EN 55022 Class A EN 55024 EN 61000-3-2 EN 61000-3-3
EN 55022 Class A EN 55024 EN 61000-3-2 EN 61000-3-3
EN 55022 Class A EN 55024 EN 61000-3-2 EN 61000-3-3
6 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L
NetVanta 1000/1000R Series Hardware Installation Guide Wireless Radio Channel Ranges
Wireless Radio Channel Ranges
The following table lists by country the channels support by the ADTRAN WiFi products (NetVanta 1335 WiFi and NetVanta 1335 WiFi PoE only).
Country
Asia 149, 153, 157, 161 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13 Australia 36, 40, 44, 48, 52, 56, 60, 64, 149, 153, 157, 161, 165 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13 Canada 36, 40, 44, 48, 52, 56, 60, 64, 149, 153, 157, 161, 165 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11
Denmark Europe 34, 38, 42, 46 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13 Finland France 34, 38, 42, 46 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13 Germany
Ireland
Italy Japan 34, 38, 42, 46 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13
Mexico 36, 40, 44, 48, 149, 153, 157, 161, 165 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11 Netherlands New Zealand 36, 40, 44, 48, 52, 56, 60, 64, 149, 153, 157, 161, 165 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13 Norway Puerto Rico 36, 40, 44, 48, 149, 153, 157, 161, 165 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11
South America 802.11a not supported 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13 Spain
Sweden Switzerland 34, 38, 42, 46 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13 United Kingdom United States 36, 40, 44, 48, 149, 153, 157, 161, 165 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11
36, 40, 44, 48, 52, 56, 60, 64, 100, 104, 108, 112, 116, 120, 124, 128, 132, 136, 140
36, 40, 44, 48, 52, 56, 60, 64, 100, 104, 108, 112, 116, 120, 124, 128, 132, 136, 140
36, 40, 44, 48, 52, 56, 60, 64, 100, 104, 108, 112, 116, 120, 124, 128, 132, 136, 140
36, 40, 44, 48, 52, 56, 60, 64, 100, 104, 108, 112, 116, 120, 124, 128, 132, 136, 140
36, 40, 44, 48, 52, 56, 60, 64, 100, 104, 108, 112, 116, 120, 124, 128, 132, 136, 140
36, 40, 44, 48, 52, 56, 60, 64, 100, 104, 108, 112, 116, 120, 124, 128, 132, 136, 140
36, 40, 44, 48, 52, 56, 60, 64, 100, 104, 108, 112, 116, 120, 124, 128, 132, 136, 140
36, 40, 44, 48, 52, 56, 60, 64, 100, 104, 108, 112, 116, 120, 124, 128, 132, 136, 140
36, 40, 44, 48, 52, 56, 60, 64, 100, 104, 108, 112, 116, 120, 124, 128, 132, 136, 140
36, 40, 44, 48, 52, 56, 60, 64, 100, 104, 108, 112, 116, 120, 124, 128, 132, 136, 140
802.11a (5 GHz)
Wireless Radios Channels
1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13
1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13
1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13
1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13
1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13
1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13
1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13
1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13
1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13
1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13
802.11bg (2.4 GHz)
Wireless Radios Channels
61200500L1-34L Copyright © 2007 ADTRAN, Inc. 7
Industry Canada Compliance Information NetVanta 1000/1000R Series Hardware Installation Guide
Industry Canada Compliance Information
Notice: The Industry Canada label applied to the product (identified by the Industry Canada logo or the “IC:” in front of the certification/registration number) signifies that the Industry Canada technical specifications were met.
Notice: The Ringer Equivalence Number (REN) for this terminal equipment is supplied in the documentation or on the product labeling/markings. The REN assigned to each terminal device indicates the maximum number of terminals that can be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the RENs of all the devices should not exceed five (5).
Canadian Emissions Requirements
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the interference-causing equipment standard entitled “Digital Apparatus,” ICES-003 of the Department of Communications.
Cet appareil numérique respecte les limites de bruits radioelectriques applicables aux appareils numériques de Class A prescrites dans la norme sur le materiel brouilleur: “Appareils Numériques,” NMB-003 edictee par le ministre des Communications.
Service and Warranty
For information on the service and warranty of ADTRAN products, visit the ADTRAN website at
http://www.adtran.com/support
.
8 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L

Table of Contents

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Power over Ethernet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Wireless Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
SFP Module Slots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Physical Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
NetVanta 1224 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
NetVanta 1224ST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
NetVanta 1224R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
NetVanta 1224STR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
NetVanta 1335 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
NetVanta 1524ST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Product Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Option Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Network Interface Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Dial Backup Interface Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Unit Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Tools Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Mounting Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Supplying Power to the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Installing Dial Backup and Network Interface Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Installing the NetVanta VPN Accelerator Card (included in P/N 4200368L1) . . . . . . . . . . . . . . . . . . 57
Installing a CompactFlash Card (NetVanta 1335 Series only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Installing Wireless Access Antennas (NetVanta 1335 WiFi and NetVanta 1335 WiFi PoE only) . . . 59
Appendix A. Connector Pin Definitions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
61200500L1-34L Copyright © 2007 ADTRAN, Inc. 9
Table of Contents NetVanta 1000/1000R Series Hardware Installation Guide
10 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L

List of Figures

Figure 1. NetVanta 1224 Front Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Figure 2. NetVanta 1224 PoE Front Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Figure 3. NetVanta 1224 and NetVanta 1224 PoE Rear Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . 17
Figure 4. NetVanta 1224ST Front Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Figure 5. NetVanta 1224ST PoE Front Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Figure 6. NetVanta 1224ST and NetVanta 1224ST PoE Rear Panel Layout . . . . . . . . . . . . . . . . . . . . 19
Figure 7. NetVanta 1224R Front Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Figure 8. NetVanta 1224R PoE Front Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Figure 9. NetVanta 1224R and NetVanta 1224R PoE Rear Panel Layout . . . . . . . . . . . . . . . . . . . . . . 22
Figure 10. NetVanta 1224STR Front Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Figure 11. NetVanta 1224STR PoE Front Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Figure 12. NetVanta 1224STR (AC) and NetVanta 1224STR PoE Rear Panel Layout . . . . . . . . . . . . . 25
Figure 13. NetVanta 1224STR (DC) Rear Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Figure 14. NetVanta 1335 Front Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Figure 15. NetVanta 1335 PoE Front Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Figure 16. NetVanta 1335 WiFi Front Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Figure 17. NetVanta 1335 WiFi PoE Front Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Figure 18. NetVanta 1335 and NetVanta 1335 PoE Rear Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . 28
Figure 19. NetVanta 1335 WiFi and NetVanta 1335 WiFi PoE Rear Panel Layout . . . . . . . . . . . . . . . . 28
Figure 20. NetVanta 1524ST Front Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Figure 21. NetVanta 1524ST Rear Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Figure 22. NetVanta 56K/64K NIM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Figure 23. NetVanta T1/FT1 NIM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Figure 24. NetVanta T1/FT1 NEBS NIM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Figure 25. NetVanta T1/FT1 + DSX-1 NIM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Figure 26. NetVanta Dual T1 NIM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Figure 27. NetVanta E1/FE1 NIM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Figure 28. NetVanta E1/FE1 + G.703 Drop NIM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Figure 29. NetVanta Serial NIM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Figure 30. NetVanta SHDSL NIM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Figure 31. NetVanta ADSL NIM, Annex A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Figure 32. NetVanta ADSL NIM, Annex B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Figure 33. Wallmount Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Figure 34. Grounding the NetVanta 1224STR (DC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Figure 35. Installing DIMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Figure 36. NIM and DIM Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Figure 37. NetVanta VPN Card Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Figure 38. CompactFlash Card Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
61200500L1-34L Copyright © 2007 ADTRAN, Inc. 11
List of Figures NetVanta 1000/1000R Series Hardware Installation Guide
12 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L

List of Tables

Table 1. Front Panel LED Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Table A-1. CONSOLE Port Pinouts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Table A-2. SFP Slot Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Table A-3. 10/100BaseT Ethernet Port Pinouts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Table A-4. 1000BaseT Gigabit-Ethernet Port Pinouts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Table A-5. WAN-DDS Connector Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Table A-6. WAN-T1 Connector Pinouts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Table A-7. WAN-E1 Connector Pinouts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Table A-8. DSX-1 Connector Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Table A-9. G.703 Connector Pinouts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Table A-10. WAN-SHDSL Connector Pinouts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Table A-11. WAN-ADSL Connector Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Table A-12. Serial to Cable Connector Pinouts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Table A-13. Analog Station (FXS) and Analog Trunk (FXO) Port Pinouts. . . . . . . . . . . . . . . . . . . . . . . . . 65
Table A-14. Analog Modem and ISDN BRI DBU Connector Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Table A-15. ISDN S/T DBU Connector Pinouts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Table A-16. Serial DBU Connector Pinouts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
61200500L1-34L Copyright © 2007 ADTRAN, Inc. 13
List of Tables NetVanta 1000/1000R Series Hardware Installation Guide
14 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L

1. INTRODUCTION

The NetVanta 1000 Series includes the NetVanta 1224, NetVanta 1224 PoE, NetVanta 1224ST, NetVanta 1224ST PoE, NetVanta 1335, NetVanta 1335 PoE, NetVanta 1335 WiFi, NetVanta 1335 WiFi PoE, and the NetVanta 1524ST. The NetVanta 1000R Series includes the NetVanta 1224R, NetVanta 1224R PoE, NetVanta 1224STR (AC), NetVanta 1224STR (DC), and NetVanta 1224STR PoE.
This hardware installation guide lists the NetVanta 1000 and 1000R Series units’ specifications, describes the physical characteristics of the units, introduces basic functionality, and provides installation instructions. All NetVanta 1000 and 1000R Series units run the ADTRAN Operating System (AOS) and are managed through an EIA-232

Power over Ethernet

The NetVanta 1000 and 1000R Series Power over Ethernet (PoE) devices provide the same basic functionality as the NetVanta 1000 Series products. Power over Ethernet provides the ability to detect attached powered devices (PD) and deliver 48 VDC to the PD via existing CAT5 cabling. The PoE devices are fully compliant with the IEEE 802.3af power over Ethernet standard. By default, the PoE switches discover and provide power to IEEE-compliant PDs.

Wireless Access

The NetVanta 1335 Wireless Fidelity (WiFi) Series provides a single access point for connection with IEEE
802.11a/b/g wireless networ ks. A dual radio design with two dual-band external antenn as is used to support concurrent 802.11a and 802.1 1b/g connections.
CONSOLE port (DB-9) located on the rear panel.

SFP Module Slots

The NetVanta 1224ST, NetVanta 1224STR PoE, NetVanta 1335, and NetVanta 1335 PoE support two SFP slots; the NetVanta 1224STR, NetVan ta 1335 W i Fi, and NetVanta 1335 WiFi PoE have one; and the NetVanta 1524ST has four. All accept a number of industry-standard SFP modules. The SFP modules provide Gigabit Ethernet connectivity over fiber for high-speed uplinks or switch stacking. The following modules are available for purchase (both of these modules require fiber optic cable with LC connectors):
1200480L1 1000BaseSX Multi-Mode SFP Module
1200481L1 1000BaseLX Single-Mode SFP Module
In this document, the term “NetVanta” means all NetVanta 1000 and NetV anta 1000R Seri es products. If a statement only applies to one particular unit, the text refers to the unit individually. Additionally, unless otherwise specified, descriptions for a NetVanta 1000 or 1000R Series device also applies to the Power over Ethernet (PoE) and WiFi versions of that device.
61200500L1-34L Copyright © 2007 ADTRAN, Inc. 15
Physical Descriptions NetVanta 1000/1000R Series Hardware Installation Guide

2. PHYSICAL DESCRIPTIONS

NetV anta 1224

The NetVanta 1224 is a managed switch housed in a 1U-high rack-mountable metal enclosure that includes a universal AC power supply . The front panel contains 24 10/100BaseT Ethernet interfaces (RJ-45). The NetVanta 1224 PoE version provides the ability to detect attached powered devices (PDs) and deliver 48 VDC to the PDs via existing CAT5 cabling.
This section includes a list of features, a list of shipping contents, and a description of the unit’s front and rear panel designs. For additional information, refer to the following sections:
Product Specifications on page 33
Mounting Options on page 51
Supplying Power to the Unit on page 53 For information on switch configuration for a specific application, refer to the quick configuration documents
provided on the ADTRAN OS System Documentation CD shipped with your base unit. For details on the command line interface, refer to the Command Reference Guide (also included on your CD).

NetVanta 1224 Shipping Contents

Each NetVanta 1224 unit is shipped in its own cardboard shipping carton. Open each carton carefully , and avoid deep penetration into the carton with sharp objects.
After unpacking the unit, inspect it for possible shipping damage. If the equipment has been d amaged in transit, immediately file a claim with the carrier and contact ADTRAN Customer Service (refer to the Repair and Replacement section of the Support page on the ADTRAN website at http://www .adtran.com/support).
Domestic shipments of the NetVanta 1224 include the following items:
NetVanta 1224 base unit
ADTRAN OS System Documentation CD
A detachable po wer cable with a grounded, three-prong plug
Quick Start Guide
Warranty card International shipments of the NetVanta 1224 include the following items:
NetVanta 1224 base unit
ADTRAN OS System Documentation CD
All necessary power cords
Quick Start Guide
Warranty card

NetVanta 1224 Front Panel Design

The NetVanta 1224 and NetVanta 1224 PoE front pan els are shown below. Table 1 on page 32 describes all of the LEDs, and Appendix A on page 61 shows the pinouts for the connectors.
16 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L
NetVanta 1000/1000R Series Hardware Installation Guide Physical Descriptions
NetVanta 1224 Front Panel Features 10/100BaseT Ethernet Interfaces
The NetVanta 1224s contain 24 10/100BaseT Ethernet interfaces (RJ-45). These interfaces are consecutively numbered 1 through 24, from left to right, with the numbers screened directly above each port. Status LEDs for each of these interfaces are located directly over these numbers.
The NetVanta 1224 PoE also has green and red PoE status LEDs located in the upper left and upper right corners (respectively) of each Ethernet connector.
Status LED
The STAT LED, which indicates the unit’s status, is located to the lower left of RJ-45 port 1.
Figure 1. NetVanta 1224 Front Panel Layout
Figure 2. NetVanta 1224 PoE Front Panel Layout
NetVanta 1224 Rear Panel Design
The NetVanta 1224 and NetVanta 1224 PoE re ar panel is shown below. Refer to Appendix A on page 61 for pinouts.
Figure 3. NetVanta 1224 and NetVanta 1224 PoE Rear Panel Layout
NetVanta 1224 Rear Panel Interfaces CONSOLE Interface
The CONSOLE interface is an EIA-232 serial port (DCE) which provides for local management and configuration (via a DB-9 female connector).
Connection directly to an external modem requires a cross-over cable.
Power Connection
The rear panel has a power input to the AC universal power supply. Please refer to Supplying Power to the Unit on page 53 for connection details.
61200500L1-34L Copyright © 2007 ADTRAN, Inc. 17
Physical Descriptions NetVanta 1000/1000R Series Hardware Installation Guide

NetV anta 1224ST

The NetVanta 1224ST and NetVanta 1224ST PoE are managed switches housed in a 1U-high rack-mountable metal enclosure that includes a universal AC power supply . The front panel contains 24 10/100BaseT Ethernet interfaces (RJ-45). The NetVanta 1224ST front panel contains two Gigabit Ethernet interfaces that provide two fixed RJ-45 connectors and two standard small form-factor pluggable (SFP) slots for connectivity over fiber. The NetVanta 1224ST PoE version provides the ability to detect attached powered devices (PDs) and deliver 48 VDC to the PDs via existing CAT5 cabling.
This section includes a list of features, a list of shipping contents, and a description of the unit’s front and rear panel designs. For additional information, refer to the following sections:
Product Specifications on page 33
Mounting Options on page 51
Supplying Power to the Unit on page 53 For information on switch configuration for a specific application, refer to the quick configuration documents
provided on the ADTRAN OS System Documentation CD shipped with your base unit. For details on the command line interface, refer to the Command Reference Guide (also included on your CD).

NetVanta 1224ST Shipping Contents

Each NetVanta 1224ST unit is shipped in its own cardboard shipping carton. Open each carton carefully, and avoid deep penetration into the carton with sharp objects.
After unpacking the unit, inspect it for possible shipping damage. If the equipment has been damag ed in transit, immediately file a claim with the carrier and contact ADTRAN Customer Service (refer to the Repair and Replacement section of the Support page on the ADTRAN website at http://www .adtran.com/support).
Domestic shipments of the NetVanta 1224ST include the following items:
NetVanta 1224ST base unit
ADTRAN OS System Documentation CD
A detachable po wer cable with a grounded, three-prong plug
Quick Start Guide
Warranty card International shipments of the NetVanta 1224ST include the following items:
NetVanta 1224ST base unit
ADTRAN OS System Documentation CD
All necessary power cords
Quick Start Guide
Warranty card

NetVanta 1224ST Front Panel Design

The NetVanta 1224ST and the NetV anta 1224ST PoE front panels are shown below. Table 1 on page 32 describes all of these LEDs, and Appendix A on page 61 shows the pinouts for the connectors.
18 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L
NetVanta 1000/1000R Series Hardware Installation Guide Physical Descriptions
NetVanta 1224ST Front Panel Features 10/100BaseT Ethernet Interfaces
The NetVanta 1224STs contain 24 10/100BaseT Ethernet interfaces (RJ-45). These interfaces are consecutively numbered 1 through 24, from left to right, with the numbers screened directly above each port. Status LEDs for each of these interfaces are located directly over these numbers.
The NetVanta 1224ST PoE also has green and red PoE status LEDs located in the upper left and upper right corners (respectively) of each Ethernet connector.
Gigabit Ethernet Interfaces/SFP Slots
The NetVanta 1224STs also contain two Gigabit Ethernet interfaces that provide two fixed RJ-45 connectors and two standard small form-factor pluggable (SFP) slots for connectivity over fiber. (Use either the RJ-45 connectors or the SFP slots. The fiber slots have precedence.) These interfaces are labeled 1, above the
Status LED
G1 and G2, and their status LEDs (also labeled G1 and G2) are located to the left of RJ-45 port
STAT LED.
The STAT LED, which indicates the unit’s status, is located to the lower left of RJ-45 port 1.
Figure 4. NetVanta 1224ST Front Panel Layout
Figure 5. NetVanta 1224ST PoE Front Panel Layout

NetVanta 1224ST Rear Panel Design

The NetVanta 1224ST and NetV anta 1224ST PoE rear panel is shown below. Refer to Appendix A on page 61 for pinouts.
Figure 6. NetVanta 1224ST and NetVanta 1224ST PoE Rear Panel Layout
61200500L1-34L Copyright © 2007 ADTRAN, Inc. 19
Physical Descriptions NetVanta 1000/1000R Series Hardware Installation Guide
NetVanta 1224ST Rear Panel Interfaces CONSOLE Interface
The CONSOLE interface is an EIA-232 serial port (DCE) which provides for local management and configuration (via a DB-9 female connector).
Connection directly to an external modem requires a cross-over cable.
Power Connection
The rear panel has a power input to the AC universal power supply. Please refer to Supplying Power to the Unit on page 53 for connection details.

NetV anta 1224R

The NetVanta 1224R and NetV anta 1224R PoE are managed switches housed in a 1U-high rack -mountable metal enclosure that includes a universal AC power supply . The front panel contains 24 10/100BaseT Ethernet interfaces (RJ-45). The NetVanta 1224R PoE version provides the ability to detect attached powered devices (PDs) and deliver 48 VDC to the PDs via existing CA T5 cabling. Both units contain a single Network Interface Module (NIM) slot on the rear panel to support the following modules:
1200861L1 56K/64K NIM
1202862L1 T1/FT1 NIM
1202863L1 T1/FT1 + DSX-1 NIM
1200872L1 Dual T1 NIM
1200868E1/L1 E1/FE1 NIM
1200878E1/L1 E1/FE1 + G.703 Drop NIM
1200866E1/L1 Serial Interface Module
1200867L1 SHDSL NIM
1200869E1/L1 ADSL NIM, Annex A
1200889E1/L1 ADSL NIM, Annex B
1200864L1 Analog Modem DIM
1200865L1 ISDN BRI DIM
1200875L1 ISDN S/T DIM
1200886L1 Serial DIM This section includes a list of features, a list of shipping contents, and a description of the unit’s front and rear
panel designs. For additional information, refer to the following sections:
Product Specifications on page 33
Mounting Options on page 51
Supplying Power to the Unit on page 53 For information on router configuration for a specific application, refer to the quick configuration documents
provided on the ADTRAN OS System Documentation CD shipped with your base unit. For details on the command line interface, refer to the Command Reference Guide (also included on your CD).
20 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L
NetVanta 1000/1000R Series Hardware Installation Guide Physical Descriptions

NetVanta 1224R Shipping Contents

Each NetV anta 1224R and NetVanta 1224R PoE unit is shipped in its own cardboard shipping carton. Open each carton carefully , and avoid deep penetration into the carton with sharp objects.
After unpacking the unit, inspect it for possible shipping damage. If the equipment has been d amaged in transit, immediately file a claim with the carrier and contact ADTRAN Customer Service (refer to the Repair and Replacement section of the Support page on the ADTRAN website at http://www .adtran.com/support).
Domestic shipments of the NetVanta 1224R include the following items:
NetVanta 1224ST base unit
ADTRAN OS System Documentation CD
A detachable po wer cable with a grounded, three-prong plug
Quick Start Guide
Warranty card International shipments of the NetVanta 1224R include the following items:
NetVanta 1224ST base unit
ADTRAN OS System Documentation CD
All necessary power cords
Quick Start Guide
Warranty card

NetVanta 1224R Front Panel Design

The NetVanta 1224R and the NetV anta 1224R PoE front panels are shown below. Table 1 on page 32 describes all of these LEDs, and Appendix A on page 61 shows the pinouts for the connectors.
NetVanta 1224ST Front Panel Features 10/100BaseT Ethernet Interfaces
The NetV anta 1224R and the NetV anta 1224R PoE contain 24 10/100BaseT Ethernet interfaces (RJ-45). These interfaces are consecutively numbered 1 through 24, from left to right, with the numbers screened directly above each port. Status LEDs for each of these interfaces are located directly over these numbers.
The NetVanta 1224R PoE also has green and red PoE status LEDs located in the upper left and upper right corners (respectively) of each of the Ethernet connectors.
61200500L1-34L Copyright © 2007 ADTRAN, Inc. 21
Physical Descriptions NetVanta 1000/1000R Series Hardware Installation Guide
Status LEDs
The status LEDs are located to the lower left of RJ-45 port 1. The WAN LED reflects the status of an installed NIM. The
DBU LED reflects the status of an installed DIM. The STAT LED indicates the
unit’s status.
Figure 7. NetVanta 1224R Front Panel Layout
Figure 8. NetVanta 1224R PoE Front Panel Layout
NetVanta 1224R Rear Panel Design
The NetVanta 1224R and NetV anta 1224R PoE rear panel is shown below. Refer to Appendix A on page 61 for pinouts.
Figure 9. NetVanta 1224R and NetVanta 1224R PoE Rear Panel Layout
NetVanta 1224R Rear Panel Interfaces NIM Option Slot
The NIM option slot accepts a variety of NIM option modules (refer to Option Modules on page 34).
CONSOLE Interface
The CONSOLE interface is an EIA-232 serial port (DCE) which provides for local management and configuration (via a DB-9 female connector).
Connection directly to an external modem requires a cross-over cable.
Power Connection
The rear panel has a power input to the AC universal power supply. Please refer to Supplying Power to the Unit on page 53 for connection details.
22 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L
NetVanta 1000/1000R Series Hardware Installation Guide Physical Descriptions

NetV anta 1224STR

The NetVanta 1224STR (AC and DC versions) and NetV anta 1224STR PoE are managed switches housed in a 1U-high rack-mountable metal enclosure that includes a either a universal AC or a DC power supply. The NetVanta 1224STR PoE version provides the ability to detect attached powered devices (PDs) and deliver 48 VDC to the PDs via existing CA T5 cabling. Both fr ont panels contain 24 10/100BaseT Ethernet interfaces (RJ-45). The NetVanta 1224STR front panel contains one Gigabit Ethernet interface which provides a fixed RJ-45 connector and one standard small form-factor pluggable (SFP) slot for connectivity over fiber . The NetV anta 12 24STR PoE front panel contains two Gigabit Ethernet interfaces and two standard small form-factor pluggable (SFP) slots. Both units contain a single Network Interface Module (NIM) slot on the rear panel to support the following modules:
1200861L1 56K/64K NIM
1202862L1 T1/FT1 NIM
1200862L2#NEBS T1/FT1 NEBS NIM (NetVanta 1224STR PoE only)
1202863L1 T1/FT1 + DSX-1 NIM
1200872L1 Dual T1 NIM
1200868E1/L1 E1/FE1 NIM
1200878E1/L1 E1/FE1 + G.703 Drop NIM
1200866E1/L1 Serial Interface Module
1200867L1 SHDSL NIM
1200869E1/L1 ADSL NIM, Annex A
1200889E1/L1 ADSL NIM, Annex B
1200864L1 Analog Modem DIM
1200865L1 ISDN BRI DIM
1200875L1 ISDN S/T DIM
1200886L1 Serial DIM This section includes a list of features, a list of shipping contents, and a description of the unit’s front and rear
panel designs. For additional information, refer to the following sections:
Product Specifications on page 33
Mounting Options on page 51
Supplying Power to the Unit on page 53 For information on router configuration for a specific application, refer to the quick configuration documents
provided on the ADTRAN OS System Documentation CD shipped with your base unit. For details on the command line interface, refer to the Command Reference Guide (also included on your CD).

NetVanta 1224STR Shipping Contents

Each NetVanta 1224STR and NetV anta 1224STR PoE units are shipped in their own cardboard shipping cartons. Open each carton carefully, and avoid deep penetration into the carton with sharp objects.
After unpacking the unit, inspect it for possible shipping damage. If the equipment has been d amaged in transit, immediately file a claim with the carrier and contact ADTRAN Customer Service (refer to the Repair and Replacement section of the Support page on the ADTRAN website at http://www .adtran.com/support).
61200500L1-34L Copyright © 2007 ADTRAN, Inc. 23
Physical Descriptions NetVanta 1000/1000R Series Hardware Installation Guide
Domestic shipments of the NetVanta 1224STR include the following items:
NetVanta 1224STR base unit
ADTRAN OS System Documentation CD
A detachable po wer cable with a grounded, three-prong plug
Quick Start Guide
Warranty card International shipments of the NetVanta 1224STR include the following items:
NetVanta 1224STR base unit
ADTRAN OS System Documentation CD
All necessary power cords
Quick Start Guide
Warranty card

NetVanta 1224STR Front Panel Design

The NetVanta 1224STR and the NetV anta 1224STR PoE front panels are shown below. Table 1 on page 32 describes all of the LEDs, and Appendix A on page 61 shows the pinouts for the connectors.
NetVanta 1224STR Front Panel Features 10/100BaseT Ethernet Interfaces
The NetVanta 1224STRs contain 24 10/100BaseT Ethernet interfaces (RJ-45). These interfaces are consecutively numbered 1 through 24, from left to right, with the numbers screened directly above each port. Status LEDs for each of these interfaces are located directly over these numbers.
The NetVanta 1224STR PoE also has green and red PoE status LEDs located in the upper left and upper right corners (respectively) of each Ethernet connector.
Gigabit Ethernet Interfaces/SFP Slots
The NetVanta 1224STR front panel contains one Gigabit Ethernet interface that provides one fixed RJ-45 connector and one standard small form-factor pluggable (SFP) slots for connectivity over fiber. (Use either the RJ-45 connectors or the SFP slots. The fiber slots have precedence.) This interfaces is labeled
G1 and the status LED is located to the left of RJ-45 port 1, above the STAT LED.
The NetVanta 1224STR PoE front panel contains two Gigabit Ethernet interfaces and two standard small form-factor pluggable (SFP) slots. (Use either the RJ-45 connectors or the SFP slots. The fiber slots have precedence.) These interfaces are labeled
G1 and G2 and the status LEDs are located above
the SFP slots.
24 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L
NetVanta 1000/1000R Series Hardware Installation Guide Physical Descriptions
Status LEDs
The status LEDs are located to the lower left of RJ-45 port 1. The WAN LED reflects the status of an installed NIM. The
DBU LED reflects the status of an installed DIM. The STAT LED indicates the
unit’s status.
Figure 10. NetVanta 1224STR Front Panel Layout
Figure 11. NetVanta 1224STR PoE Front Panel Layout

NetVanta 1224STR Rear Panel Design

The NetV anta 1224STR and NetVanta 1224STR PoE rear panels are shown below. Refer to Appendix A on page 61 for pinouts.
Figure 12. NetVanta 1224STR (AC) and NetVanta 1224STR PoE Rear Panel Layout
USE COPPER
CONDUCTORS ONLY
-48V....., 1.2A
+24V....., 2.5A
Figure 13. NetVanta 1224STR (DC) Rear Panel Layout
NetVanta 1224STR Rear Panel Interfaces NIM Option Slot
The NIM option slot accepts a variety of NIM option modules (refer to Option Modules on page 34).
CONSOLE Interface
The CONSOLE interface is an EIA-232 serial port (DCE) which provides for local management and configuration (via a DB-9 female connector).
Connection directly to an external modem requires a cross-over cable.
61200500L1-34L Copyright © 2007 ADTRAN, Inc. 25
Physical Descriptions NetVanta 1000/1000R Series Hardware Installation Guide
Power Connection
The rear panel of the NetVanta 1224STR (AC) and NetVanta 1224STR PoE have a power input for connection to an AC universal power supply. The NetVanta 1224STR (DC) connects to a centralized DC power source via a four-position power connector. Please refer to Supplying Power to the Unit on page 53 for connection details.

NetV anta 1335

All NetVanta 1335 Series units are managed switches plus multiservice routers housed in a 1U-high rack-mountable metal enclosure that includes a universal AC power supply . The NetVanta 1335 PoE and NetVanta 1335 WiFi PoE provide the ability to detect attached powered devices (PDs) and deliver 48 VDC to the PDs via existing CAT5 cabling. The NetVanta 1335 WiFi Series units operate as wireless bridges for local area networks (LANs). A dual radio design with two dual-band external antennas is used to support concurrent
802.11a and 802.11b/g connections. The NetVanta 1335 Series front panels contain 24 10/100BaseT Ethernet interfaces and two Gigabit Ethernet interfaces accessed via a fixed RJ-45 connector or SFP slots for fiber connectivity . The NetVanta 1335 WiFi Series front panels contain 24 10/100BaseT Ethernet interfaces and one Gigabit Ethernet interface accessed via a fixed RJ-45 connector or SFP slot. All NetVanta 1335 Series units
include IPSec VPN support (without further software upgrades) and expandable memory via CompactFlash and SODIMM slots. NetVanta 1335 Series units also contain one NIM slot on the rear panel to support the following modules in data applications:
®
1200861L1 56K/64K NIM
1202862L1 T1/FT1 NIM
1202863L1 T1/FT1 + DSX-1 NIM
1200872L1 Dual T1 NIM
1200868E1/L1 E1/FE1 NIM
1200878E1/L1 E1/FE1 + G.703 Drop NIM
1200866E1/L1 Serial Interface Module
1200867L1 SHDSL NIM
1200869E1/L1 ADSL NIM, Annex A
1200889E1/L1 ADSL NIM, Annex B
1200864L1 Analog Modem DIM
1200865L1 ISDN BRI DIM
1200875L1 ISDN S/T DIM This section includes a list of features, a list of shipping contents, and a description of the front and rear panel
designs. For additional information, refer to the following sections:
Product Specifications on page 33
Mounting Options on page 51
Supplying Power to the Unit on page 53 For information on router configuration for a specific application, refer to the quick configuration documents
provided on the ADTRAN OS System Documentation CD shipped with your base unit. For details on the command line interface, refer to the Command Reference Guide (also included on your CD).

NetVanta 1335 Shipping Contents

Each NetVanta 1335 unit is shipped in its own cardboard shipping carton. Open each carton carefully , and avoid deep penetration into the carton with sharp objects.
26 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L
NetVanta 1000/1000R Series Hardware Installation Guide Physical Descriptions
After unpacking the unit, inspect it for possible shipping damage. If the equipment has been d amaged in transit, immediately file a claim with the carrier and contact ADTRAN Customer Service (refer to the Repair and Replacement section of the Support page on the ADTRAN website at http://www .adtran.com/support).
Domestic shipments of the NetVanta 1335 include the following items:
NetVanta 1335 base unit
ADTRAN OS System Documentation CD
Two dual-band RP-SMA detachable antennas (NetVanta 1335 WiFi and NetVanta 1335 WiFi PoE only)
A detachable po wer cable with a grounded, three-prong plug
Quick Start Guide
Warranty card International shipments of the NetVanta 1335 include the following items:
NetVanta 1335 base unit
ADTRAN OS System Documentation CD
Two dual-band RP-SMA detachable antennas (NetVanta 1335 WiFi and NetVanta 1335 WiFi PoE only)
All necessary power cords
Quick Start Guide
Warranty card

NetVanta 1335 Front Panel Design

The NetVanta 1335 Series front panels are shown on page 28. Table 1 on page 32 descri bes all of the LEDs, and Appendix A on page 61 shows the pinouts for the connectors.
NetVanta 1335 Front Panel Features 10/100BaseT Ethernet Interfaces
The NetVanta 1335 Series units contain 24 10/100BaseT Ethernet interfaces (RJ-45). These interfaces are consecutively numbered 1 through 24, from left to right, with the numbers screened directly above each port. Status LEDs for each of these interfaces are located directly over these numbers.
Gigabit Ethernet Interfaces/SFP Slots
The NetVanta 1335 and NetVanta 1335 PoE contain two Gigabit Ethernet interfaces that pr ovide two fixed RJ-45 connectors and two standard small form-factor pluggable (SFP) slots for connectivity over fiber. These interfaces are labeled
G1 and G2, and the status LEDs are located above the SFP slots. The
NetVanta 1335 WiFi and NetVanta 1335 W iFi PoE contain one Gigabit Ethernet interface that provides a fixed RJ-45 connector and one standard small form-factor pluggable (SFP) slot for connectivity over fiber. This interface is labeled
G1, and the status LED is located above the SFP slot. (Use either the
RJ-45 connectors or the SFP slots. The fiber slots have precedence.)
61200500L1-34L Copyright © 2007 ADTRAN, Inc. 27
Physical Descriptions NetVanta 1000/1000R Series Hardware Installation Guide
Status LEDs
The status LEDs are located to the lower left of RJ-45 port 1. The WLAN LED (NetVanta 1335 WiFi Series only) reflects the status of the wireless network. The NIM. The
DBU LED reflects the status of an installed DIM. The STAT LED indicates the unit’s status.
Figure 14. NetVanta 1335 Front Panel Layout
Figure 15. NetVanta 1335 PoE Front Panel Layout
WAN LED reflects the status of an installed
NetVanta 1335
Figure 16. NetVanta 1335 WiFi Front Panel Layout
Figure 17. NetVanta 1335 WiFi PoE Front Panel Layout

NetVanta 1335 Rear Panel Design

The NetVanta 1335 Series rear panels are shown below. Refer to Appendix A on page 61 for pinouts.
Figure 18. NetVanta 1335 and NetVanta 1335 PoE Rear Panel Layout
Figure 19. NetVanta 1335 WiFi and NetVanta 1335 WiFi PoE Rear Panel Layout
28 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L
NetVanta 1000/1000R Series Hardware Installation Guide Physical Descriptions
NetVanta 1335 Rear Panel Interfaces NIM Option Slot
The NIM option slot accepts a variety of NIM option modules (refer to Option Modules on page 34).
CompactFlash
The CompactFlash® slot supplies nonvolatile configuration and compressed code storage. The NetVanta 1335 supports only ADTRAN-provided CompactFlash (16 MB to 1 GB) (refer to the part
number on the front cover of this manual).
CONSOLE Interface
The CONSOLE interface is an EIA-232 serial port (DCE) which provides for local management and configuration (via a DB-9 female connector).
Connection directly to an external modem requires a cross-over cable.
Antenna Connectors
The ANT 1 and ANT 2 ports (NetVanta 1335 WiFi and NetVanta 1335 WiFi PoE only) support two dual-band antennas for concurrent 802.11a and 802.11b/g connections.
Power Connection
The rear panel has a power input to the AC universal power supply. Please refer to Supplying Power to the Unit on page 53 for connection details.
NetV anta 1524ST
The NetVanta 1524ST is a Layer 2 managed switch housed in a 1U-high rack-mountable metal enclosure that includes a universal AC power supply . The front panel contains 24 10/100/1000BaseT Ethernet interfaces that are accessed via standard RJ-45 connectors. Four of these twenty-four interfaces can be used in either copper or fiber mode. Four industry-standard SFP slots (supporting industry-standard SFP modules) are available for high-speed uplink or stacking requirements. The switch is managed through an EIA-232 (DB-9).
This section includes a list of features, a list of shipping contents, and a description of the unit’s front and rear panel designs. For additional information, refer to the following sections:
Product Specifications on page 33
Mounting Options on page 51
Supplying Power to the Unit on page 53 For information on switch configuration for a specific application, refer to the quick configuration documents
provided on the ADTRAN OS System Documentation CD shipped with your base unit. For details on the command line interface, refer to the Command Reference Guide (also included on your CD).
CONSOLE port
61200500L1-34L Copyright © 2007 ADTRAN, Inc. 29
Physical Descriptions NetVanta 1000/1000R Series Hardware Installation Guide

NetVanta 1524ST Shipping Contents

Each NetVanta 1524ST unit is shipped in its own cardboard shipping carton. Open each carton carefully, and avoid deep penetration into the carton with sharp objects.
After unpacking the unit, inspect it for possible shipping damage. If the equipment has been damag ed in transit, immediately file a claim with the carrier and contact ADTRAN Customer Service (refer to the Repair and Replacement section of the Support page on the ADTRAN website at http://www .adtran.com/support).
Domestic shipments of the NetVanta 1524ST include the following items:
NetVanta 1524ST base unit
ADTRAN OS System Documentation CD
A detachable po wer cable with a grounded, three-prong plug
Quick Start Guide
Warranty card International shipments of the NetVanta 1524ST include the following items:
NetVanta 1524ST base unit
ADTRAN OS System Documentation CD
All necessary power cords
Quick Start Guide
Warranty card

NetVanta 1524ST Front Panel Design

The NetVanta 1524ST front panel is shown below. Table 1 on page 32 describes all of the LEDs, and Appendix A on page 61 shows the pinouts for the connectors.
NetVanta 1524ST Front Panel Features 10/100/1000BaseT Ethernet Interfaces
The NetVanta 1524ST front panel contains 24 10/100/1000BaseT Ethernet interfaces (RJ-45). These interfaces are consecutively numbered 1 through 24, from left to right, with the numbers screened directly above each port. Status LEDs for each of these interfaces are located directly over these numbers.
SFP Slots
The NetVanta 1524ST front panel contains four standard small form-factor pluggable (SFP) slots for connectivity over fiber. These interfaces are numbered 21 through 24. Status LEDs for each of these slots are located directly over these numbers.
Status LEDs
The status LEDs are located to the lower left of RJ-45 port 1. The STK LED indicates whether the unit is a member of a stack. The
STAT LED indicates the unit’s status.
Figure 20. NetVanta 1524ST Front Panel Layout
30 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L
NetVanta 1000/1000R Series Hardware Installation Guide Physical Descriptions

NetVanta 1524ST Rear Panel Design

The NetVanta 1524ST rear panel is shown below. Refer to Appendix A on page 61 for pinouts.
Figure 21. NetVanta 1524ST Rear Panel Layout
NetVanta 1524ST Rear Panel Interfaces 10/100BaseT Ethernet Interface
The Ethernet port (ETH 0/0) is an RJ-45 connector. The Ethernet port provides the following:
• 10BaseT or 100BaseT with a single connector
• Auto-negotiation
• CSMA/CD
• IEEE 802.3 compatibility
CONSOLE Interface
The CONSOLE interface is an EIA-232 serial port (DCE) which provides for local management and configuration (via a DB-9 female connector).
Connection directly to an external modem requires a cross-over cable.
Power Connection
The rear panel has a power input to the AC universal power supply. Please refer to Supplying Power to the Unit on page 53 for connection details.
61200500L1-34L Copyright © 2007 ADTRAN, Inc. 31
Physical Descriptions NetVanta 1000/1000R Series Hardware Installation Guide
Table 1. Front Panel LED Descriptions
LED Color Indication
STAT
Off Unit is not receiving power. Green (solid) Power is on and self-test passed. Green (flashing) On power-up the STAT LED flashes rapidly for five
seconds, during which time the user may escape to boot mode from the CONSOLE port.
Red (solid) Power is on, but the self-test failed or the boot code could
not be booted.
STK (1524ST only)
Off Unit is not a member of a stack. Green (solid) Unit is a member of a stack.
Port LEDs (i.e., 1 through 24, G1, G2, etc.)
Off Port is administratively disabled or does not have a
connection. Green (solid) Port is enabled and has a connection. Amber (flashing) Port has activity (transmit or receive).
DBU
(1224R, 1224STR, and 1335 only)
Off No DIM is installed. Green (solid) DIM is ready. For the ISDN BRI DIM, green solid indicates
that the negotiation with the switch is complete. Green (flashing) Unit is in dial backup. Amber (solid) Unit is in test. Red (solid) Alarm condition is occurring on the DBU interface, or there
is a self-test failure.
WAN
(1224R, 1224STR, and 1335 only)
Off No NIM is installed, or interface is administratively down. Green (solid) NIM is up and everything is operational. Green (flashing) Port has activity (transmit or receive). Amber (solid) Unit is in test Red (solid) Alarm condition is occurring on the WAN inter face, or ther e
is a self-test failure.
Power over Ethernet Status LEDs
(PoE units only)
WLAN
(1335 WiFi and 1335 WiFi PoE)
Green (solid) Power is being ap plie d (4 8 V) to the int er fa ce . Red (solid) Fault is detected on the interface.
Off WLAN is inactive or disabled. Green (solid) WLAN card is enabled and active. Amber (flashing) Activity (transmit or receive) is detected on the WLAN.
32 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L
NetVanta 1000/1000R Series Hardware Installation Guide Product Specifications

3. PRODUCT SPECIFICATIONS

1224
1224ST
1224STR (AC)
1224STR (DC)
Physical Interfaces
10/100BaseT Ethernet interfaces on the front panel 24 24 24 24 24 24 24 24 0 1000BaseT Gigabit Ethernet interfaces on the front panel
(SFP slots for connectivity over fiber / RJ-45 connectors for copper connectivity)
Integrated DB-9, EIA-232 console port (DCE) on the rear panel
Modular network interface on the rear panel N/A N/A 1 1 1 1 1 1 N/A
Stacking Spanning Tree Support (802.1D and 802.1w) Link Aggregation (802.3ad) VLAN Support (802.1Q), up to 255 active VLANs Priority QoS (802.1p) Management
Console Telnet CLI SSH CLI SNMP V2 Port mirroring
Power
AC Power: 100 to 250 VAC, 50/60 Hz DC Power: 24 to 48 VDC
Mechanical Specifications
Housing: 1U-high metal enclosure (1.72-inch H x 17.22-inch W x 7.8-inch D) (The 1224STR PoE and 1335 PoE Series are 12.8-inches deep.)
10/100BaseT Ethernet: 24 ganged RJ-45 jacks 10/100/1000BaseT Ethernet: SFP slots/standard RJ-45
jacks Console Port: DB-9, female
Dual-band Antenna Connections 000000020 CompactFlash
Environmental Specifications
AC Input Power: 100 to 250 VAC DC Input Power: 24 to 48 VDC at 2.5 A Storage Temperature: -20°C to 70°C Operating Temperature: 0°C to 50°C Relative Humidity: Up to 95 percent, noncondensing
0211202124
111111111
DDDDDDDDD
DDDDDDDDD
DDDDDDDDD
DDDDDDDDD
DDDDDDDDD
DDDDDDDDD
DDDDDDDDD
DDDDDDDDD
DDDDDDDDD
DDDDDDDDD
DDD DDDDD
D
DDDDDDDDD
DDDDDDDD
0211102124
DDDDDDDDD
DDD DDDDD
D
DDDDDDDDD
DDDDDDDDD
DDDDDDDDD
1224STR PoE
1224R
DD
1335, 1335 PoE
1524ST
1335 WiFi Series
61200500L1-34L Copyright © 2007 ADTRAN, Inc. 33
Option Modules NetVanta 1000/1000R Series Hardware Installation Guide

4. OPTION MODULES

The NetVanta 1224STR, 1224R, and 1335 support several option modules designed to meet a variety of networking requirements. The option modules include plug-in network interface modules (NIMs) and plug-on dial backup interface modules (DIMs).
NIMs are cards which plug directly into the option module slot located on the rear of the base unit. These cards provide the following types of interfaces:
NetVanta 56K/64K NIM (P/N 1200861L1) on page 35
NetVanta T1/FT1 NIM (P/N 1202862L1) on page 36
NetVanta T1/FT1 NEBS NIM (P/N 1200862L2#NEBS) on page 37
NetVanta T1/FT1 + DSX-1 NIM (P/N 1202863L1) on page 38
NetVanta Dual T1 NIM (P/N 1200872L1) on page 39
NetVanta E1/FE1 NIM (P/N 1200868E1/L1) on page 40
NetVanta E1/FE1 + G.703 Drop NIM (P/N 1200878E1/L1) on page 41
NetVanta Serial NIM (P/N 1200866E1/L1) on page 42
NetVanta SHDSL NIM (P/N 1200867L1) on page 43
NetVanta ADSL NIM, Annex A (P/N 1200869E1) on page 44
NetVanta ADSL NIM, Annex B (P/N 1200889E1) on page 45 DIMs are plug-on cards which plug directly on to the NIM prior to installation into the base unit. A DIM must
be plugged on to a NIM in order for the interfaces on the NIM to be active. The NetVanta supports the following DIMs:
NetVanta Analog Modem DIM (P/N 1200864L1) on page 46
NetVanta ISDN BRI DIM (P/N 1200865L1) on page 47
NetVanta ISDN S/T DIM (P/N 1200875L1) on page 48
NetVanta Serial DIM (P/N 1200886L1) on page 49 This section describes each module, providing individual card specifications and features. Refer to Connector
Pin Definitions on page 61 for pinout information. Installing Dial Backup and Network Interface Modules on page 54 provides information on card installation.
34 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L
NetVanta 1000/1000R Series Hardware Installation Guide Option Modules
Network Interface Modules

NetVanta 56K/64K NIM (P/N 1200861L1)

The 56K/64K NIM (shown in Figure 22) provides a DDS WAN interface for the NetVanta. This module provides a single 56K or 64K DDS network interface. Refer to Table A-5 on page 63 for the WAN-DDS connector pinouts, and Table A-14 on page 66 for the DBU connector pinouts. An optional DIM is required for dial backup applications.
Figure 22. NetVanta 56K/64K NIM
Features and Specifications
Operating Modes
Dedicated DDS (leased line)
DDS Interface
Supported Standards: AT&T TR 62310
4-wire, full-duplex
Receiver Sensitivity: -45 dB, all rates
Data Rates: 56K, 64K, and auto
Connector: RJ-48S
Clock Source
•Network
•Internal
Diagnostics
CSU and DSU Loopbacks
Compliance
EMC - see Electromagnetic Compatibility (EMC) Table on page 6.
ACTA/FCC Part 68
IC CS-03
UL/CUL 60950
Environmental
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95 percent, noncondensing
Physical
Dimensions: 2.75-inch W x 4. 25-inch D
61200500L1-34L Copyright © 2007 ADTRAN, Inc. 35
Option Modules NetVanta 1000/1000R Series Hardware Installation Guide

NetVanta T1/FT1 NIM (P/N 1202862L1)

The T1/FT1 NIM (shown in Figure 23) provides a T1 WAN interface for the NetVanta. This module provides a full T1 or fractional T1 network interface. Refer to Table A-6 on page 63 for the WAN-T1 connector pinouts and Table A-14 on page 66 for the DBU connector pinouts. An optional DIM is required for dial backup applications.
WAN-T1 DBU
Figure 23. NetVanta T1/FT1 NIM
Features and Specifications
Operating Modes
Frame Relay, Multilink Frame Relay
PPP, Multilink PPP
HDLC
T1/FT1 Interface
Supported Standards: AT&T TR 62411, AT&T TR 65016, ANSI T1.403, Bellcore TR 194
Line Rate: 1.544 Mbps +
75 bps
Line Code: AMI or B8ZS
Framing: D4 (SF) or ESF
FT1 Line Rate: DS0 channelized (multiples of 64 kbps)
Input Signal: 0 to -36 dB (DS1)
Line Build-Out: 0, -7.5, -15, -22.5 dB (long), 0 to 655 ft (short)
DS0 Assignment: Programmable
Connector: RJ-48C
Clock Source
•Network
•Internal
Diagnostics
Test Pattern Generation and Detection: 511, QRSS, all ones, all zeros
Network loopbacks (local and remote); responds to both inband and FDL loop codes
Alarm generation and detection
Network and user sets of performance data (15 minutes and 24 hours)
Compliance
EMC - see Electromagnetic Compatibility (EMC) Table on page 6.
ACTA/FCC Part 68
IC CS-03
UL/CUL 60950
Environmental
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95 percent, noncondensing
Physical
Dimensions: 2.75-inch W x 4. 25-inch D
36 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L
NetVanta 1000/1000R Series Hardware Installation Guide Option Modules

NetVanta T1/FT1 NEBS NIM (P/N 1200862L2#NEBS)

The T1/FT1 NEBS NIM (see Figure 24) T1 W AN interface for the NetVanta 1224STR DC. The T1 NEBS NIM is NEBS Level 3 compliant, and provides a full T1 or fractional T1 network interface. See Table A-6 on page 63 for the WAN-T1 connector pinouts.
Although the T1/FT1 NEBS NIM is compliant with NEBS Level 3, the NetVanta 1224STR DC unit supports only NEBS Level 1.
WAN-T1
Figure 24. NetVanta T1/FT1 NEBS NIM
Features and Specifications
Operating Modes
Frame Relay, Multilink Frame Relay
PPP, Multilink PPP
HDLC
T1/FT1 Interface
Supported Standards: AT&T TR 62411, AT&T TR 65016, ANSI T1.403, Bellcore TR 194
Line Rate: 1.544 Mbps +
75 bps
Line Code: AMI or B8ZS
Framing: D4 (SF) or ESF
FT1 Line Rate: DS0 channelized (multiples of 64 kbps)
Input Signal: 0 to -36 dB (DS1)
Line Build-Out: 0, -7.5, -15, -22.5 dB (long), 0 to 655 ft (short)
DS0 Assignment: Programm able
Connector: RJ-48C
Clock Source
•Network
•Internal
Diagnostics
Test Pattern Generation and Detection: QRSS, 511, 2
15
- 1, 2
20
- 1, all ones,
all zeros
Network loopbacks (local and remote); responds to inband and FDL loop codes
Alarm generation and detection
Network and user sets of performance data (15 minutes and 24 hours)
Compliance
EMC - see Electromagnetic Compatibility (EMC) Table on page 6.
NEBS Level 3
•GR-63-CORE
GR-1089-CORE
UL/CUL 60950
Environmental
Operating Temperature: 0°C to 50°C
Storage Temperature : -20°C to 70°C
Relative Humidity: Up to 95 percent noncondensing
Physical
Dimensions: 2.75-inch W x 4.25-inch D
61200500L1-34L Copyright © 2007 ADTRAN, Inc. 37
Option Modules NetVanta 1000/1000R Series Hardware Installation Guide

NetVanta T1/FT1 + DSX-1 NIM (P/N 1202863L1)

The T1/FT1 + DSX-1 NIM (see Figure 25) provides a T1 WAN interface for the NetVanta, a full or fractional T1 network interface, and a DSX-1 interface. See the pinouts in Table A-6 on page 63 for the WAN-T1 connector, Table A-8 on page 64 for the DSX-1 connector, and Table A-14 on page 66 for the DBU connector pinouts. An optional DIM is required for dial backup applications.
WAN-T1 DSX-1 DBU
Figure 25. NetVanta T1/FT1 + DSX-1 NIM
Features and Specifications
Operating Modes
Frame Relay, Multilink Frame Relay
PPP, Multilink PPP
HDLC
T1/FT1 Interface
Supported Standards: AT&T TR 62411, AT&T TR 65016, ANSI T1.403, Bellcore TR 194
Line Rate: 1.544 Mbps +
75 bps
Line Code: AMI or B8ZS
Framing: D4 (SF) or ESF
FT1 Line Rate: DS0 channelized (multiples of 56/64 kbps)
Input Signal: 0 to -36 dB (DS1)
Line Build-Out: 0, -7.5, -15, -22.5 dB (long), 0 to 655 ft (short)
DS0 Assignment: Programmable
Connector: RJ-48C
DSX-1 Interface
Line Interface: DSX-1 per ANSI T1.102
DSX Receiver Input Range: -10 dB dsx to +6 dBdsx
Line Rate: 1.544 Mbps
Capacity: 1 to 24 DS0s
Line Codes: AMI, B8ZS
DSX-1 Interface to PBX
Framing: D4 (SF) or ESF
Line Length: 0 to 655 feet and -7.5 dB
Connector: RJ-48C
Clock Source
•Network
•Internal
Through
Diagnostics
Test Pattern Generation and Detection: 511, QRSS, all ones, all zeros
Network loopbacks (local and remote); responds to inband and FDL loop codes (T1 interface only)
Alarm generation and detection
Network and user sets of performance data (15 minutes and 24 hours)
Compliance
EMC - see Electromagnetic Compatibility (EMC) Table on page 6.
ACTA/FCC Part 68
IC CS-03
UL/CUL 60950
Environmental
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95 percent, noncondensing
Physical
Dimensions: 2.75-inch W x 4. 25-inch D
38 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L
NetVanta 1000/1000R Series Hardware Installation Guide Option Modules

NetVanta Dual T1 NIM (P/N 1200872L1)

The NetVanta Dual T1 NIM (see Figure 26) provides two WAN T1 interfaces for the NetVanta. Refer to Table A-6 on page 63 for the pinouts. Refer to Table A-14 on page 66 for the DBU connector pinouts. An optional
DIM is required for dial backup applications.
Figure 26. NetVanta Dual T1 NIM
Features and Specifications
Operating Modes
Frame Relay, Multilink Frame Relay
PPP, Multilink PPP
HDLC
T1 Interface
Supported Standards: AT&T TR 62411, AT&T TR 65016, ANSI T1.403, Bellcore TR 194
Line Rate: 1.544 Mbps +
75 bps
Line Code: AMI or B8ZS
Framing: D4 (SF) or ESF
FT1 Line Rate: DS0 channelized (multiples of 64 kbps)
Input Signal: 0 to -36 dB (DS1)
Line Build-Out: 0, -7.5, -15, -22.5 dB (long), 0 to 655 ft (short)
DS0 Assignment: Programm able
Connector: RJ-48C
Clock Source
•Network
•Internal
Through
Diagnostics
Test Pattern Generation and Detection: QRSS, 511, 2
15
- 1, 2
20
- 1, all ones,
all zeros
Network loopbacks (local and remote); responds to both inband and FDL loop codes
Alarm generation detection
Network performance data (15 minutes and 24 hours)
Compliance
EMC - see Electromagnetic Compatibility (EMC) Table on page 6.
ACTA/FCC Part 68
IC CS-03
UL/CUL 60950
Environmental
Operating temperature: 0°C to 50°C
Storage Temperature: -20 °C to 70°C
Relative Humidity: Up to 95 percent, noncondensing
Physical
Dimensions: 2.75-inch W x 4.25-inch D
61200500L1-34L Copyright © 2007 ADTRAN, Inc. 39
Option Modules NetVanta 1000/1000R Series Hardware Installation Guide

NetVanta E1/FE1 NIM (P/N 1200868E1/L1)

The NetVanta E1/FE1 module (see Figure 27) provides a W AN-E1 interface for the NetVanta meeting the requirements of ITU-T G.703/G .704. The module provides a single 2.048 Mbps network interface. Refer to T able A-7 on page 63 for the pinouts. Refer to Table A-14 on page 66 for the DBU connector pinouts. An optional DIM is required for dial backup applications.
WAN-E1 DBU
Figure 27. NetVanta E1/FE1 NIM
Features and Specifications
Operating Modes
Frame Relay, Multilink Frame Relay
PPP, Multilink PPP
HDLC
WAN-E1 Interface
Supported Standards : ITU G.703 , ITU-T G.704 (CRC-4), ITU-T G.823, ITU-T G.797
Line Rate: 2.048 Mbps +
50 PPM
Line Code: AMI or HDB3
Framing: FAS with optional CRC-4
FE1 Line Rate: Channelized timeslot (in multiples of 64 kbps)
Receiver Sensitivity: -30 dB
Connector: RJ-48C
Clock Source
•Network
•Internal
Diagnostics
Test Pattern Generation and Detection: QRSS, 511, all ones, all zeros
Network loopbacks
Network performance data (15 minutes and 24 hours)
Alarm generation and detection
Compliance
EMC - see Electromagnetic Compatibility (EMC) Table on page 6.
•AS/ACIF S016
ETSI TBR 12/TBR 13
EN 60950
IEC 60950
AS/NZS 60950
RoHS Compliant (Telecommu nications exemption)
Environmental
Operating temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95 percent, noncondensing
Physical
Dimensions: 2.75-inch W x 4.25-inch D
40 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L
NetVanta 1000/1000R Series Hardware Installation Guide Option Modules

NetVanta E1/FE1 + G.703 Drop NIM (P/N 1200878E1/L1)

The NetVanta E1/FE1 + G .703 Drop NIM (see Figure 28) provides a single WAN-E1 interface (2.043 Mbps) with user-selectable TS0 assignment and a G.703 drop port which may be used to drop and insert traffic to an E1 PBX. See Table A-7 on page 63 for the WAN-E1 pinouts. See Table A-9 on page 64 for the G.703 pinouts. See Table A-14 on page 66 for the DBU connector pinouts. An optional DIM is required for dial backup applications.
WAN-E1 G.703 DBU
Figure 28. NetVanta E1/FE1 + G.703 Drop NIM
Features and Specifications
Operating Modes
Frame Relay, Multilink Frame Relay
PPP, Multilink PPP
HDLC
WAN-E1 Interface
Supported Standards: ITU G.703 , ITU-T G.704 (CRC-4), ITU-T G.823, ITU-T G.797
Line Rate: 2. 048 Mbps +
50 PPM
Line Code: AMI or HDB3
Framing: FAS with optional CRC-4
FE1 Line Rate: Channelized timeslot (in multiples of 64 kbps)
Receiver Sensitivity: -30 dB
Connector: RJ-48C
G.703 Interface
Receiver Sensitivity: -30 dB
Line Rate: 2. 048 Mbps +
50 PPM
Line Code: AMI or HDB3
Framing: FAS with optional CRC-4
Capacity: 1 to 31 timeslots
Connector: RJ-48C
Diagnostics
Test Pattern Generation and Detection: QRSS, 511, all ones, all zeros
Network loopbacks
Network performance data (15 minutes and 24 hours)
Alarm generation and detection
Compliance
EMC - see Electromagnetic Compatibility (EMC) Table on page 6.
AS/ACIF S016
ETSI TBR 12/TBR 13
EN 60950
IEC 60950
AS/NZS 60950
RoHS Compliant (Telecommunications exemption)
Environmental
Operating temperature: 0°C to 50°C
Storage Temperature : -20°C to 70°C
Relative Humidity: Up to 95 percent, noncondensing
Clock Source
•Network
Physical
Dimensions: 2.75-inch W x 4.25-inch D
•Internal
Through
61200500L1-34L Copyright © 2007 ADTRAN, Inc. 41
Option Modules NetVanta 1000/1000R Series Hardware Installation Guide

NetVanta Serial NIM (P/N 1200866E1/L1)

The NetV anta Serial NIM (shown in Figure 29) can be configured by the user as a V.35, X.21 (V.11), or EIA 530 interface. This module supports rates up to a maximum of 10 Mbps. An additional V.35 (ADTRAN P/N 1200873L1), X.21 (ADTRAN P/N 1200874L1), or EIA 530 (ADTRAN P/N 1200883L1) cable is required (refer to Caution, below). See T able A-12 on page 65 for the serial connector pinouts, and Table A-14 on page 66 for the DBU connector pinouts. An optional DIM is required for dial backup applications.
Cable length for the Serial NIM should not exceed 25 feet.
SERIAL DBU
Figure 29. NetVanta Serial NIM
Features and Specifications
Operating Mode
DTE only
Serial Interface
Supported Standards: ISO 4903 (X.21), CCITT V.35 Synchronous (V.35), EIA 530 Synchronous
Provides V.35, X.21 (V.11), or EIA 530 electrical interface
Connector: 26-pin smart serial (DTE)
Compliance
EMC - see Electromagnetic Compatibility (EMC) Table on page 6.
ETSI TBR1
ETSI TBR2
EN 60950
IEC 60950
UL/CUL 60950
AS/NZS 60950
RoHS Compliant (Telecommunications exemption)
Environmental
Operating Temperature: 0°C to 50°C
Storage Temperature : -20°C to 70°C
Relative Humidity: Up to 95 percent, noncondensing
Physical
Dimensions: 2.75-inch W x 4.25-inch D
42 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L
NetVanta 1000/1000R Series Hardware Installation Guide Option Modules

NetVanta SHDSL NIM (P/N 1200867L1)

The NetVanta SHDSL NIM (shown in Figure 30) provides a W AN SH DSL interface for the NetVanta. See Table A-10 on page 64 for the SHDSL connector pinouts. See Table A-14 on page 66 for the DBU connector pinouts. An optional DIM is required for dial backup applications.
WAN-SHDSL
Figure 30. NetVanta SHDSL NIM
Features and Specifications
Operating Mode
Line termination (CO)
Network termination (CPE)
SHDSL Interface
Supported Standards: ITU-T G.991.2 SHDSL
Line Rate: 200 to 2312 kbps in 64k increments
Line Code: TC-PAM
Connector: RJ-45
Clock Source
CPE Operating Mode: Network
CO Operating Mode: Internal
DBU
Compliance
EMC - see Electromagnetic Compatibility (EMC) Table on page 6.
•AS/ACIF S043
EN 60950
AS/NZS 60950
Environmental
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95 percent, noncondensing
Physical
Dimensions: 2.75-inch W x 4.25-inch D
Diagnostics
Test Pattern Generation and Detection:
15
2
- 1
Network loopbacks (local and remote)
Alarm generation and detection
Programmable alarm threshold setting for loop attenuation and signal-to-noise ratio
61200500L1-34L Copyright © 2007 ADTRAN, Inc. 43
Option Modules NetVanta 1000/1000R Series Hardware Installation Guide

NetVanta ADSL NIM, Annex A (P/N 1200869E1)

The NetVanta ADSL NIM, Annex A (see Figure 31) adds ADSL capability to the NetVanta. The module provides a single ADSL, ADSL2, or ADSL2+ network interface to support rates up to 25 Mbps. See T able A-11 on page 64 for the pinouts. The ADSL NIM supports an optional DIM for dial backup applications. See Table A-14 on page 66 for the DBU connector pinouts.
WAN-ADSL
Figure 31. NetVanta ADSL NIM, Annex A
Features and Specifications
ADSL Interface
ADSL over POTS, Annex A
Supported Standards: – ITU G.992.1 (G.dmt)
ITU G.992.2 (G.lite) – ITU G.992.3 ADSL2 (G.dmt.bis) – ITU G.992.5 ADSL2+ – ANSI T1.413 Issue 2 – Reach Extended ADSL (READSL2)
Connector: RJ-11C (6-pin jack, inner pair)
ATM
Multiple Protocol over AAL5 (RFC2684)
PPP over ATM (RFC2364)
PPP over Ethernet (RFC2516)
ATM Forum UNI 3.1/4.0 PVC
ATM Class of Service (UBR)
ATM F5 OAM
Up to 16 Virtual Circuits
DBU
Compliance
EMC - see Electromagnetic Compatibility (EMC) Table on page 6
ACTA/FCC Part 68
AS/ACIF S043
AS/ACIF S002
IC CS-03
EN 60950
IEC 60950
UL/CUL 60950
AS/NZS 60950
RoHS Compliant (Telecommunications exemption)
Environmental
Operating temperature: 0°C to 50°C
Storage Temperature : -20°C to 70°C
Relative Humidity: Up to 95 percent, noncondensing
Physical
Dimensions: 2.75-inch W x 4.25-inch D
44 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L
NetVanta 1000/1000R Series Hardware Installation Guide Option Modules

NetVanta ADSL NIM, Annex B (P/N 1200889E1)

The NetVanta ADSL NIM, Annex B (see Figure 32) adds ADSL capability to the NetVanta. See Table A-1 1 on page 64 for the pinouts. The ADSL NIM supports an optional DIM for dial backup applications. See Table A-14 on page 66 for the DBU connector pinouts.
WAN-ADSL
Figure 32. NetVanta ADSL NIM, Annex B
Features and Specifications
ADSL Interface
ADSL over ISDN, Annex B
Supported Standards: ITU G.992 .1 (G.dmt)
Connector: RJ-11C (6-pin jack, inner pair)
ATM
Multiple Protocol over AAL5 (RFC2684)
PPP over ATM (RFC2364)
PPP over Ethernet (RFC2516)
ATM Forum UNI 3.1/4.0 PVC
ATM Class of Service (UBR)
ATM F5 OAM
Up to 16 virtual circuits
DBU
Compliance
EMC - see Electromagnetic Compatibility (EMC) Table on page 6
AS/ACIF S043
EN 60950
IEC 60950
AS/NZS 60950
RoHS Compliant (Telecommunications exemption)
Environmental
Operating temperature: 0°C to 50°C
Storage Temperature : -20°C to 70°C
Relative Humidity: Up to 95 percent, noncondensing
Physical
Dimensions: 2.75-inch W x 4.25-inch D
61200500L1-34L Copyright © 2007 ADTRAN, Inc. 45
Option Modules NetVanta 1000/1000R Series Hardware Installation Guide
Dial Backup Interface Modules

NetVanta Analog Modem DIM (P/N 1200864L1)

The Analog Modem DIM provides a modem with data rates up to 33.6 kbps for the NetVanta. This DIM is a plug-on card that connects to the NIM. For installation instructions, refer to Installing Dial Backup and Network Interface Modules on page 54.

Features and Specifications

Features
Supported Standards: ITU V.90
•Async
Compliance
EMC - see Electromagnetic Compatibility (EMC) Table on page 6.
ACTA/FCC Part 68
IC CS-03
UL/CUL 60950
Environmental
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95 percent, noncondensing
Physical
Dimensions: 2.5-inch W x 3.75-inch D
The Analog Modem DIM can be used in two different modes:
1. Backup interface for a primary connection.
2. CONSOLE port for remote dial-in access.
46 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L
NetVanta 1000/1000R Series Hardware Installation Guide Option Modules

NetVanta ISDN BRI DIM (P/N 1200865L1)

The NetVanta ISDN BRI DIM provides dial backup access to the public switched telephone network (PSTN) via Basic Rate ISDN for the NetVanta. This DIM is a plug-on module that connects to the NIM. For installation instructions, refer to Installing Dial Backup and Network Interface Modules on page 54.

Features and Specifications

Features
Clear Channel and bond ing mode 1 call protocols
Network support for 64 kbps (1 B-channel) or 128 kbps (2 B-channels)
D-channel switch compatibility with AT&T 5ESS, Northern Telecom DMS-100, and National ISDN-1
V.54 network loopback support
Compliance
EMC - see Electromagnetic Compatibility (EMC) Table on page 6.
ACTA/FCC Part 68
IC CS-03
UL/CUL 60950
Environmental
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95 percent, noncondensing
Physical
Dimensions: 2.5-inch W x 3.75-inch D
61200500L1-34L Copyright © 2007 ADTRAN, Inc. 47
Option Modules NetVanta 1000/1000R Series Hardware Installation Guide

NetVanta ISDN S/T DIM (P/N 1200875L1)

The NetVanta ISDN S/T DIM provides dial backup access to the public switched telephone network (PSTN) via Basic Rate ISDN for the NetVanta. This DIM is a plug-on module that connects to the NIM. For installation instructions, see Installing Dial Backup and Network Interface Modules on page 54.

Features and Specifications

Features
Clear channel and bonding mode 1 call protocols
Network support for 64 kbps (1 B-channel) or 128 kbps (2 B-channels)
D-channel switch compatibility with AT&T 5ESS, Northern Telecom DMS-100, National ISDN-1, and Euro-ISDN
V.54 network loopback support
Compliance
EMC - see Electromagnetic Compatibility (EMC) Table on page 6.
AS/ACIF S031
ETSI TBR 3
EN 60950
IEC 60950
AS/NZS 60950
Environmental
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95 percent, noncondensing
Physical
Dimensions: 2.5-inch W x 3.75-inch D
48 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L
NetVanta 1000/1000R Series Hardware Installation Guide Option Modules

NetVanta Serial DIM (P/N 1200886L1)

The NetVanta Serial DIM provides NetVanta products with the ability to interface with external devices (e.g., Code Division Multiple Access (CDMA) devices and wireless modems), allowing for dial backup access to the public switched telephone network (PSTN). This DIM is a plug-on module that connects to the NIM. For installation instructions, see Installing Dial Backup and Network Interface Modules on page 54.
An RJ-45 to DB-9 adapter cable (P/N 1200887L1) is required to connect to the external modem.

Features and Specifications

Features
5-pin RS-232 interface vial host RJ-45 DBU connector
Modem flow control support via CTS
Communications with external model via AT commands
Compliance
EMC - see Electromagnetic Compatibility (EMC) Table on page 6.
IEC 60950
EN 60950
UL/CL 60950
AS/NZS 60950
Environmental
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95 percent, noncondensing
Physical
Dimensions: 2.3-inch W x 2.75-inch D
61200500L1-34L Copyright © 2007 ADTRAN, Inc. 49
Unit Installation NetVanta 1000/1000R Series Hardware Installation Guide

5. UNIT INSTALLATION

The instructions and guidelines provided in this section cover hardware installation topics such as mounting options, supplying power to the unit, and installing option cards. These instructions are presented as follows:
Mounting Options on page 51
Supplying Power to the Unit on page 53
Installing Dial Backup and Network Interface Modules on page 54
Installing the NetVanta VPN Accelerator Card (included in P/N 4200368L1) on page 57 For information on configuring a specific application, refer to the quick configuration documents provided on
the ADTRAN OS System Documentation CD or the Command Line Reference Guide (also included on your CD).
To prevent electrical shock, do not install equipment in a wet location or during a lightning storm.
Electronic modu les can be damaged by static electrical discharge. Before handling modules, put on an antistatic discharge wrist strap to prevent damage to electrical components. Place modules in antistatic packing material when transp orting or storing. When working on modules, always place them on an approved antistatic mat that is electrically grounded.

Tools Required

The customer-provided tools required for the hardware installation of the NetVanta are:
Ethernet cables
Network cables (module dependent)
DSX-1 cable (T1/FT1 + DSX-1 module only)
DBU cable (dial backup functions require an optional DIM)
Phillips-head screwdriver (rack-mounted applications only)
To access the command line interface (CLI) of the NetVanta, you will also need a VT100 terminal or PC with terminal emulation softwar e a nd a console port cable. Instructi ons on how to access the CLI are given in the Command Reference Guide (provided on the ADTRAN OS System Documentation CD).
50 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L
NetVanta 1000/1000R Series Hardware Installation Guide Unit Installation
Mounting Options
The unit may be installed in rackmount, wallmount, or tabletop configurations. The following sections provide step-by-step instructions for rack mounting and wall mounting.
If you have purchased the VPN Accelerator Card for your NetVanta 1224STR, install it first (refer to Installing the NetVanta VPN Accelerator Card (included in P/N 4200368L1) on page 57).

Rack Mounting the NetVanta

The NetVanta is a 1U-high, rack-mountable unit which can be installed into a 19-inch equipment rack. The following steps guide you in mounting the NetVanta into a rack.
Instructions for Rack Mounting the NetVanta
Step Action
1 To allow proper grounding, scrape the paint from the rack around the mounting holes where the
NetVanta will be positioned. 2 Position th e Net Vanta in a stationary equipment rack. This unit occupies 1U of space. 3 Have an assistant hold the unit in position as you install two mounting bolts through the unit’s
brackets and into the equipment rack using a #2 phillips-head screwdriver. 4 Apply powe r to the unit (r efe r to Supplying Power to the Unit on page 53).
Be careful not to compromise the stability of the equipment mounting rack when installing this product.
61200500L1-34L Copyright © 2007 ADTRAN, Inc. 51
Unit Installation NetVanta 1000/1000R Series Hardware Installation Guide

Wall Mounting the NetVanta

By following these instructions exactly , the NetVanta can be safely mounted to the wall.
Instructions for Wall Mounting the NetVanta
Step Action
1 Remove the mounting ears. Rotate them 90 degr ees so that the portion of the bracket with the
mounting holes is flush with the bottom of the chassis. Reattach the mounting ears to the chassis (see Figure 33).
2 Decide on a location for the NetVanta. All NetVanta 1000 and 1000R Series units are mounted
with the front panel facing down (see Figure 33). Keep in mind that the unit needs to be mounted at or below eye-level so that the LEDs are viewable.
3 Prepare the mounting surface by att aching a bo ard (typically plywood, 3/ 4-inch to 1-inch thick)
to a wall stud.
Important! Mounting to a stud ensures stability. Using sheetrock anchors may not provide sufficient long-term stability.
4 Have an assistant hold the unit in position as you inst a ll two #6 to #10 (1 1/ 2 inches or greater
in length) wood screws through the unit’s brackets and into the mounted board (see Figure 33) .
5 Proceed to the steps given in Supplying Power to the Unit on page 53.
To avoid damaging the unit, use only the screws included in the shipment when attaching mounting ears to the chassis.
50-60Hz
100-250 VAC
CONSOLE
SLOT 1 NIM/VIM
Figure 33. Wallmount Installation
52 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L
NetVanta 1000/1000R Series Hardware Installation Guide Unit Installation

Supplying Power to the Unit

NetVanta 1000 and 1000R Series AC-Powered Units

The AC-powered NetVanta 1000 and 1000R Series units come equipped with an auto-sensing 100 to 250 VAC, 50/60 Hz power supply for connecting to a properly grounded power receptacle. (A detachable power cable with a grounded, three-prong plug comes with the shipment.) T o power these units, connect the power cable to an appropriate AC power source.

NetVanta 1224STR (DC)

The DC-powered NetVanta 1224STR connects to a centralized DC power source via the four-position power connector on the rear of the chassis (see Figure 34 on page 54). Power and ground connections require copp er conductors and a ring lug.
Instructions for Connecting DC Power Source to the NetVanta 1224STR
Step Action
1 With the power disconnected, connect the primary power source to input A of the power
connector.
2 Connect a ground wire (fitted with a loop terminal end) to the grounding point using the screw
provided. Connect the other end of the ground wire to a protective earth groun d. See Figur e 34 on page 54.
3 If using a backup power source, connect it to input B of the power connector.
Power to the NetVanta 1224STR DC System must be from a reliably grounded 24 or 48 VDC.
Use only copper conductors when making power connections.
Install unit in accordance with the requirements of NEC NFPA 70.
The branch circuit overcurrent protection shall be a fuse or circuit breaker rated minimum 48 VDC, maximum 10 A.
A readily accessible disconnect device, that is suitably approved and rated, shall be incorporated in the field wiring.
Maximum recommended ambient operating temperature is 50
°C.
The 10/100BaseT and Gigabit-Ethernet interfaces MUST NOT be metallically connected to interfaces which connect to the Outside Plant or its wiring. These interfaces are designed for use as intra-building interfaces only. The addition of primary protectors is not sufficient protection in order to connect this interface metallically to OSP wiring.
61200500L1-34L Copyright © 2007 ADTRAN, Inc. 53
Unit Installation NetVanta 1000/1000R Series Hardware Installation Guide
To comply with GR-1089-CORE, Issue 3, this equipment MUST only be installed in a DC-C (common) bonding and grounding environment. It may not be utilized in a DC-I (isolated) bonding and grounding environment.
Figure 34. Grounding the NetVanta 1224STR (DC)
Installing Dial Backup and Network Interface Modules
The DIM plugs on to the NIM. The NIM is then installed into the rear panel option module slot. The following tables list the installation steps. Also see Figure 35 on page 55 and Figure 36 on page 56.
For NetVanta modules with outside plant connections, ensure that all cables are removed from the module before installing or removing it from the NetVanta chassis.
Always remove power from the unit prior to removing or installing a module.
Improper installation may result in damage to the modules.
54 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L
NetVanta 1000/1000R Series Hardware Installation Guide Unit Installation
Instructions for Installing the DIMs
Step Action
1 Remove power from the unit. 2 If the NIM is already in the NetVanta chassis, remove all cables, release the pins at both edges
of the NIM front panel and slide the module out of the chassis.
3 Carefully align the P1 connector on the NIM with the J1 connector on the DIM. Using only fingertip
pressure so that neither circuit board bends or flexes, ensure that the connectors are firmly seated. Secure the DIM to the NIM using the screws and standoff posts supplied. See Figure 35.
4 Slide the NIM with the DIM attached into the NetVanta chassis, continuing with the normal NIM
installation (refer to Instructions for Installing the NIMs on page56).
Figure 35. Installing DIMs
61200500L1-34L Copyright © 2007 ADTRAN, Inc. 55
Unit Installation NetVanta 1000/1000R Series Hardware Installation Guide
Instructions for Installing the NIMs
Step Action
1 Remove power from the unit. 2 Slide the option module into the option slot until the module is firmly seated against the chassis. 3 Secure the pins at both edges of the module. 4 Connect the cables to the associated device(s). 5 Restore power to the unit.
Figure 36. NIM and DIM Installation
56 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L
NetVanta 1000/1000R Series Hardware Installation Guide Unit Installation
Installing the NetVanta VPN Accelerator Card (included in P/N 4200368L1)
The optional VPN Accelerato r card plugs into a 32-bit PCI slot an d is designed to be used in the NetVanta 1224STR to provide encryption/decryption and security acceleration services. The card provides the following security services to the host processor: DES, triple-DES (3DES), AES, SHA-1, MD5, and random number generation. Performance metrics include 528 Mbps (DES), 176 Mbps (3DES), and 422 Mbps (AES). The power consumption of the card does not exceed 2 watts.
The AOS Enhanced Feature Pack software is required to take advantage of the VPN acceleration features of this card.
The NetVanta VPN accelerator card is intended to be serviced/installed by qualified service personnel only.
Instructions for Installing the NetVanta VPN Accelerator Card
Step Action
1 Remove power from the unit. 2 Remove the nine screws and, if necessary, two mountin g brackets (see Figure 37). 3 Using a 3/16-inch hex driver, remove the two jack screws located on either side of the DB-9 port. 4 Carefully lift and remove the unit’s cover to expose the circuit board. 5 Gently slide the accelerator card into the PCI slot as shown. The card is keyed to fit into the slot
only one way. To avoid damaging the card pins, do not use excessive force. 6 Replace the unit cover, screws, and mounting brackets. 7 Restore power to the unit.
Figure 37. NetVanta VPN Card Installation
61200500L1-34L Copyright © 2007 ADTRAN, Inc. 57
Unit Installation NetVanta 1000/1000R Series Hardware Installation Guide
Installing a CompactFlash Card (NetVanta 1335 Series only)
The CompactFlash slot on the NetVanta 1335 Series supports CompactFlash
®
cards (16 MB to 1 GB).
ADTRAN supports only ADTRAN-provided Com pactFlash (16 MB to 1 GB) (refer to the list of part numbers on the front cover). Follow these instructions when installing a card.
The CompactFlash card is hot-swappable and can be inserted or removed while power is applied to the unit.
Instructions for Installing a CompactFlash Card
Step Action
1 Slide the module into the CompactFlash slot until the card is firmly seated against the chassis. 2 The CompactFlash options will now be available in the GUI and the AOS CLI.
CompactFlash
512 MB
Figure 38. CompactFlash Card Installation
58 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L
NetVanta 1000/1000R Series Hardware Installation Guide Unit Installation
Installing Wireless Access Antennas (NetVanta 1335 WiFi and NetVanta 1335 WiFi PoE only)
The NetVanta 1335 WiFi Series units ship with two dual-band RP-SMA detachable antennas. These must be installed before operating the unit.
Instructions for Inst alling Antennas
Step Action
1 Place either of the two antennas directly onto the antenna port labeled ANT 1 on the rear panel.
See Figure 19 on page 28 for port locations.
2 Twist the antenna onto the threads until it is secure. 3 Repeat step 2 with the second antenna, attaching it to the ANT 2 port.
Your NetVanta is now ready to be configured and connected to the network. For more information on configuration for a specific application, refer to the quick configuration documents provided on the ADTRAN
OS System Documentation CD. For details on the command line interface, refer to the Command Reference Guide (also included on your CD).
61200500L1-34L Copyright © 2007 ADTRAN, Inc. 59
Unit Installation NetVanta 1000/1000R Series Hardware Installation Guide
60 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L

APPENDIX A. CONNECTOR PIN DEFINITIONS

The following tables provide the pin assignments for the base unit, network interface modules (NIMs), and dial backup interface modules (DIMs).
Base Unit Pinouts
Table A-1. CONSOLE Port Pinouts
Pin Name Description
1 DCD Data Carrier Detect (output) 2 RD Receive Data (output) 3 TD Transmit Data (input) 4 DTR Data Terminal Ready (input) 5 SG Signal Ground 6 DSR Data Set Ready Tied to pin 1 (output) 7 Unused 8 CTS Clear to Send Tied to pin 1 (output) 9 Unused
Table A-2. SFP Slot Pinouts
Pin Name Pin Name
1RX_LOS11RGND 2RGND12RX_DAT­3RGND13RX_DAT+ 4MOD_DEF(0)14 RGND 5 MOD_DEF(1) 15 VddR 6MOD_DEF(2)16 VddT 7 TX_DISABLE 17 TGND 8TGND18TX_DAT+ 9TGND19TX_DAT-
10 TX_FAULT 20 TGND
61200500L1-34L Copyright © 2007 ADTRAN, Inc. 61
Appendix A. Connector Pin Definitions NetVanta 1000/1000R Series Hardware Installation Guide
Table A-3. 10/100BaseT Ethernet Port Pinouts
Pin Name Description
1 TX1 Transmit Positive 2 TX2 Transmit Negative 3 RX1 Receive Positive
4, 5 Unused
6 RX2 Receive Negative
7, 8 Unused
Table A-4. 1000BaseT Gigabit-Ethernet Port Pinouts
Pin Name Description
1 TRD0+ Transmit/Receive Positive 2 T RD0- Transmit/Rec eiv e Neg a tive 3 TRD1+ Transmit/Receive Positive 4 TRD2+ Transmit/Receive Positive 5 T RD2- Transmit/Rec eiv e Neg a tive 6 T RD1- Transmit/Rec eiv e Neg a tive 7 TRD3+ Transmit/Receive Positive 8 T RD3- Transmit/Rec eiv e Neg a tive
62 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L
NetVanta 1000/1000R Series Hardware Installation Guide Appendix A. Connector Pin Definitions
Network Interface Module Pinouts
Table A-5. WAN-DDS Connector Pinouts
Pin Name Description
1 R1 Transmit data to the network–Ring 1 2 T1 Transmit data to the network–Tip 1
3-6 Unused
7 T Receive data from the network–Tip 8 R Receive data from the network–Ring
Table A-6. WAN-T1 Connector Pinouts
Pin Name Description
1 R1 Receive data from the network–Ring 1 2 T1 Receive data from the network–Tip 1 3 Unused 4 R Transmit data toward the network–Ring 5 T Transmit data toward the network–Tip
6-8 Unused
Table A-7. WAN-E1 Connector Pinouts
Pin Name Description
1 R1 Receive data from the network–Ring 1 2 T1 Receive data from the network–Tip 1 3 Unused 4 R Transmit data toward the network–Ring 5 T Transmit data toward the network–Tip
6-8 Unused
61200500L1-34L Copyright © 2007 ADTRAN, Inc. 63
Appendix A. Connector Pin Definitions NetVanta 1000/1000R Series Hardware Installation Guide
Table A-8. DSX-1 Connector Pinouts
Pin Name Description
1 R Transmit data toward the DTE–Ring 2 T Transmit data toward the DTE–Tip 3 Unused 4 R1 Receive data from the DTE–Ring 1 5 T1 Receive data from the DTE–Tip 1
6-8 Unused
Table A-9. G.703 Connector Pinouts
Pin Name Description
1 R Transmit data toward the DTE–Ring 2 T Transmit data toward the DTE–Tip 3 Unused 4 R1 Receive data from the DTE–Ring 1 5 T1 Receive data from the DTE–Tip 1
6-8 Unused
Table A-10. WAN-SHDSL Connector Pinouts
Pin Name Description
1-3 Unused
4 T Transmit data toward the network–Tip 5 R Transmit data toward the network–Ring
6-8 Unused
Table A-11. WAN-ADSL Connector Pinouts
Pin Name Description
1, 2 Unused
3 R ADSL Ring 4 T ADSL Tip
5, 6 Unused
64 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L
NetVanta 1000/1000R Series Hardware Installation Guide Appendix A. Connector Pin Definitions
Table A-12. Serial to Cable Connector Pinouts
Serial
Pin
V.35
Pin
X.21
Pin
EIA 530
Pin Name
1P22 TD_A 2UN/A24 ETC_A 3 Y N/A 15 TCLK_A 4 V 6 17 RCLK_A 5 R 4 3 RD_A 6 F N/A 8 DCD_A 7HN/A20 DTR_A 8C34 RTS_A 9 N/A 10 19 RTS_B (V.11 only)
10 N/A 12 13 CTS_B (V.11 only)
11 D 5 5 CTS_A 12 E N/A 6 DSR_A 13 K N/A 25 TM_A 14 S 9 14 TD_B 15 W N/A 11 ETC_B 16 AA N/A 12 TCLK_B 17 X 13 9 RCLK_B 18 T 11 16 RD_B
19-26 N/A N/A N/A Unused
26 B 8 7 Ground
Table A-13. Analog Station (FXS) and Analog Trunk (FXO) Port Pinouts
Pin Name Description
1, 2 Unused
3 Ring Ring lead of the 2-wire interface 4 Tip Tip lead of the 2-wire interface
5, 6 Unused
61200500L1-34L Copyright © 2007 ADTRAN, Inc. 65
Appendix A. Connector Pin Definitions NetVanta 1000/1000R Series Hardware Installation Guide
Dial Backup Interface Module Pinouts (DBU Connector)
An optional DIM is required for dial backup applications.
Table A-14. Analog Modem and ISDN BRI DBU Connector Pinouts
Pin Name Description
1-3 Unused
4 R Network–Ring 5 T Network–Tip
6-8 Unused
Table A-15. ISDN S/T DBU Connector Pinouts
Pin Name Description
1, 2 Unused
3 R1 Network Receive–Ring 1 4 R Network Transmit–Ring 5 T Network Transmit–Tip 6 T1 Network Transmit–Tip 1
7, 8 Unused
Table A-16. Serial DBU Connector Pinouts
Pin Description
1, 2 Unused
3CTS 4TXD 5RXD 6GND 7 DCD 8Unused
66 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L

Index

Numerics

1000BaseLX single-mode SFP module 15 1000BaseSX multi-mode SFP module 15 56K/64K NIM
35
A
ADSL, Annex A module 44 ADSL, Annex B module 45 ADTRAN operating system antenna connectors 29 antennas 15, 26
15
C
command line interface 50 CompactFlash
installing a CompactFlash card
console port description
26, 29
58
15
D
DBU LED 32 Dial Backup Interface Modules
Analog Modem ISDN BRI 47 ISDN S/T Serial 49
DIMs, installing 54 dual T1 NIM
46
48
39
E
E1/FE1 + G.703 drop module 41 E1/FE1 module 40 EMC table
6
F
front panel
32
LEDs
G
grounding NetVanta 1224STR (DC) 53
I
installation
rack mounting instructions 51 wall mounting instructions
installing a CompactFlash card installing DIMs 54 installing NIMs installing the unit installing VPN accelerator card installing wireless access antennas
56
50
52
58
57
59
L
LEDs, description of 32
M
mounting options 51
N
NetVanta 1224
brief description front panel 16 rear panel 17 shipping contents
NetVanta 1224R
brief description 20 front panel rear panel 22 shipping contents 21
NetVanta 1224ST
brief description front panel rear panel shipping contents 18
NetVanta 1224STR
brief description front panel 24 rear panel shipping contents 23
NetVanta 1335
brief description front panel 27 rear panel 28 shipping contents
NetVanta 1524ST
brief description 29 front panel rear panel 31 shipping contents 30
Network Interface Modules
56K/64K ADSL, Annex A ADSL, Annex B Dual T1 39
40
E1/FE1 E1/FE1 + G.703
42
serial SHDSL 43
36
T1/FT1 T1/FT1 + DSX-1 T1/FT1 NEBS 37
NIMs, installing
16
16
21
18
18
19
23
25
26
26
30
35
44 45
41
38
56
O
option modules discussion 34
P
pinouts
10/100BaseT ports 1000BaseT ports 62
62
61200500L1-34L Copyright © 2007 ADTRAN, Inc. 67
Index NetVanta 1000/1000R Series Hardware Installation Guide
ADSL connector 64 console port 61 DBU connector 66 DDS connector DSX-1 connector 64 E1 connector 63 FXS and FXO G.703 connector 64 serial to cable connector SFP slots 61 SHDSL connector 64 T1 connector
port LEDs 32 power
NetVanta AC-powered units NetVanta DC-powered unit 53 supplying to unit 53
power over Ethernet product registration 8 product specifications 33
physical interfaces
63
65
63
15
33
R
rack mounting instructions 51 radio channels 7
S
safety instructions 4 serial module 42 SFP module descriptions 15 SHDSL interface
43
63
53
SHDSL module shipping contents
NetVanta 1224 16 NetVanta 1224R NetVanta 1224ST 18 NetVanta 1224STR 23 NetVanta 1335 NetVanta 1524ST 30
specifications STAT LED 32 STK LED 32
43
21
26
33
T
T1, dual module 39 T1/FT1 + DSX-1 module 38 T1/FT1 module 36 T1/FT1 NEBS module tools required for installation 50
37
V
VPN accelerator card 57
W
wall mounting instructions 52 WAN LED 32 warranty 8
15
WiFi wireless access 15
antennas 59
wireless radio channel ranges
7
68 Copyright © 2007 ADTRAN, Inc. 61200500L1-34L
Loading...