ADTRAN DS3 User Manual

TOTAL ACCESS 4303 DS3 MODULE
DS3 MODULE
CLEI: SLPOCD0C_ _
1200333L1
ONLINE STATUS DS3
61200333L1-22B
0310
For a complete Installation and Maintenance Practice (P/N 61200333L1-5): 877-457-5007, Faxback Document 860. Please have your fax number ready.
C A U T I O N C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
FRONT PANEL LEDs
ONLINE Off Blown fuse or no power supplied to the shelf
Green Online
Flashing Green Offline
Amber Self-test in progress
Red Module failure
Flashing Red Self-test failure
STATUS Green Active DS3 Module
Flashing Green Standby DS3 - redundancy enabled
Flashing Red Standby DS3 - cannot automatically become the active
DS3 while the current active DS3 is installed
DS3 Off DS3/DS1 not configured for use
Green DS3/DS1 signal present and synchronized; channel is
configured for use
Amber DS3/DS1 test in progress (includes port self-test)
Red DS3/DS1 alarm present
Flashing Red DS3/DS1 error
NOTE: The Total Access 4303 DS3 Module requires SCU firmware of C.02 or greater.
INSTALLATION
Insert the module into the desired slot (1 through 4 only) (hot insertion permissible).
The module connects to connectors on the backplane. Connecting the BNC Module
(P/N 1200323L1) to the connectors provides two dual BNC connectors (see the BNC Module Job Aid, 61200323L1-22).
The Total Access
®
4303 SCU automatically detects the presence of the module. There
is no need to reboot.
Once installed, use the terminal menus to configure and control the module (see the
SCU Job Aid, 61200334L1-22).
Use the arrow keys on the VT100 terminal keyboard to move to the Modules menu;
press ENTER in the Menu column of the appropriate module.
JOBAID
#61200333L1-22B#
SPECIFICATIONS
Specifications
Framing M13 or C-Bit Parity Line Coding B3ZS (bipolar 3 zero substitution) Line Build Out 0 to 50 feet (Short)
51 to 450 feet (Long)
Tests Self-test
Local Line and Payload Loopbacks
Remote Line and Payload Loopbacks Line Rate 44.736 Mbps ± 895 bps Terminating Impedance 75 ohms ± 5%, unbalanced Power 12 watts Compliance FCC Part 15, UL 60950, NEBS Level 3 Temperature Operation: 0ºC to 50ºC
Storage: –40ºC to 70ºC Relative Humidity To 95% noncondensing
COMPLIANCE
The Total Access 4303 DS3 module is NRTL listed to the applicable UL standards. The Total Access DS3 is to be installed in a restricted access location and in a Type “B” or “E” enclosure only.
This device complies with Part 15 of the FCC rules. Operation is subject to the fol­lowing two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by ADTRAN could void the user’s authority to operate this equipment.
WARRANTY
ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service. Warranty information can be found at www.adtran.com/warranty. U.S. and Canada customer Faxback: 877-457-5007, Document 414.
Code Input Output
Power Code (PC) F C Telecommunication Code (TC) – Installation Code (IC) A
TOTAL ACCESS 4303 DS3 MODULE
PRICING AND AVAILABILITY 800.827.0807
TECHNICAL SUPPORT 800.726.8663
RETURN FOR REPAIR 256.963.8722
www.adtran.com
61200333L1-22B
MENU TREE FOR THE DS3 MODULE TERMINAL MENUS
Total Access 4303
G
Module Menu
DS3 Info
DS3 Configurations
DS3 Alarms
DS3 Perf Current DS3 Perf 15 Min DS3 Perf 24 Hr
DS3 Test
DS1 Configuration
G1
Part Number Serial Number CLEI Code Board Revision
[Prt] Port Name Frame Format
Clock Source
LBO [Prt]
Rx Alarms Far End Alarms CBIT Status (Rx Framing)
[Prt] Clear Results <+> Errored Seconds - line Severely Errored Seconds - line LOS Seconds - line Code Violation - path Errored Sec - path SEF/AIS Seconds - path Severely Errored Sec - path Unavailable Sec - path
[Prt]
LoopBack
Remote LB
Remote Status
[Prt] Port Name State
OSS Threshold IS Threshold
Frame Format
Auto TX Yellow Alarm Transmit PRMs
Loopback Accept
Remote Device
M13 CBIT Recovered Internal
Short Long
None Line
None DS3 Line DS1 #N Line (where N=1 to 28) DS1 All Line
Auto Auto BER IS IS AS OOS
None 2E-7
• • • 9E-7 1E-6
• • • 7E-6
D4 ESF
Off On
Accept Ignore
Disabled ADTRAN Type 1 Type 2
G1
DS1 Alarm & Status
DS1 Signal Status
DS1 Perf Current DS1 Perf 15 Min DS1 Perf 24 Hr
DS1 Test
DS0 Configuratiion DS0 Alarms
DS0 Map Status
Redundancy
[Prt] Alarms Status BER
[Prt] Rx Tx
[Prt] Clear Results <+> Errored Seconds Bursty Errored Seconds Severely Errored Seconds Severely Errored Frame Secs Loss of Frame Count Controlled Slip Seconds Unavailable Seconds Path Code Violations Degraded Minutes
[Prt] Local Loopback
Remote Loopback
Test Pattern
Test Status Pattern Status Clear <+> Pattern Error Inject <+>
[Prt] DS0 Config DS0 Not Used Count
Module Redundancy
Error Threshold
Minimum Switch Time Switch Count Clear Switch Count <+> Force Switchover <+>
None Line Payload
None ATT Inband ANSI FDL Line ANSI FDL Pyld NIU Inband
None All Ones All Zeros QRSS QRSS 56k DALY 3-IN-24 1-IN-8 2-IN-8
Disabled Enabled
Disabled 1E-03 1E-04 1E-05 1E-06