ADTRAN DDM + H2TU-C User Manual

JOBAID
61222003L2-22A
0104
DDM+ H2TU-C
CLEI: T1L3X5BA_ _
STATUS LEDs
STAT US RED Alarm on the H2TU-C loop, H2R loop, DSX or DS1 interface.
FLASHING Signal Quality of 0 or No Sync on the loop.
GREEN Functioning properly.FLASHING ES, SES, or BPV detected at either DSX or DS1 interface.
RS-232 DB-9 CONNECTOR
Used to access the HDSL2 utilities menu tree via VT100 emulation software such as
Terminal, Hyper Terminal – Private Edition, and ProComm Plus.
There are two types of terminal emulation modes, Manual and Real-Time. To toggle
between the two modes, type “CTRL” and “T.” To update the screens while in Manual Mode, press the space bar 3 times. Real-Time Update Mode is the default.
Provision terminal port as follows:
Data Rate — 1.2 kbps to 19.2 kbps Asynchronous Data Format — eight data bits, no parity (none), one stop bit, and no
flow control.
Hardware Flow Control – disabled.
When using a PC with terminal software, be sure to disable any power saving programs.
COMPLIANCE CODES
This product is intended to be installed in an enclosure with an Installation Code (IC) of “B” or “E” and in Restricted Access Locations only.
WARRANTY
Warranty for Carrier Networks products manufactured by ADTRAN and supplied under Buyer’s order for use in the U.S. is ten (10) years. For a complete faxback copy of ADTRAN’s U.S. and Canada Carrier Networks Equipment Warranty: (877) 457-5007, Document #414.
CIRCUIT BOARD 6-POSITION DIP SWITCH – SW1
Provisions the unit. (Default settings are in bold.)
SW1-1
Selects line coding to AMI or B8ZS
SW1-2
Selects T1-framing to FRAMED or UNFRAMED
1
SW1-3
Selects T1-framing to SF or ESF
SW1-4
ENABLES or DISABLES the NIU loopback
SW1-5
ENABLES or DISABLES the loopback timeout
2
SW1-6
ENABLES or DISABLES the shelf alarm
1
UNFRAMED operation ignores the setting of SW1-3
2
Default timeout setting is 20 minutes when loopback timeout is ENABLED
CIRCUIT BOARD 5-POSITION ROTARY SWITCH – SW2
Sets the DSX-1 Line Build Out (LBO). (Default settings are in bold.)
0 — 0-133 feet of LBO
133 — 133-266 feet of LBO
266 — 266-399 feet of LBO
399 — 399-533 feet of LBO
533 — 533-655 feet of LBO
DDM+ H2TU-C
Code Input Output
Installation Code (IC) A — Telecommunication Code (TC) X Power Code (PC) F C
C A U T I O N
For a complete Installation and Maintenance faxback document: (877) 457-5007, Document #695. Please have your fax number available.
DSX-1 LBO
SW2
7
6
5
0
0
133
1
2
266
3
4
C A U T I O N
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
!
533
399
INDICATIONS AND PROBABLE CAUSES
Front Panel or Circuit Parameters Indicate Abnormal Operation
Connect a terminal or PC to the RS-232 (DB-9) craft interface located on the faceplate. The terminal must be VT100 or compatible and set for 1.2 to 19.2 kbps, 8 data bits, no parity, 1 stop bit, and no flow control. Select “3” from the ADTRAN HDSL2 Main Menu Screen and “2” from the Span Status Screen:
Is signal quality fluctuating (this would occur when real-time mode is active)?
Is ATTEN (pulse attenuation) > 30 dB?
Are there any errors counting on the ES, SES, or UAS registers?
If the above conditions do not exist, the circuit should provide quality service; however, if any of the above conditions exist, a cable problem or excessive loss situation is probable and more detailed cable testing should be done to verify all HDSL2 Loop Specifications are met. These conditions may also reflect intermittent cable faults or excessive noise impairments. If intermittent faults or noise impairments are suspected, select “5” from the HDSL2 Main Menu and review the Performance History Screen.
F
ront Panel Indications Under Normal Operation
STATUS Green
Circuit Parameters Under Normal Operation
LOSS < 30 dB
Good signal quality with no fluctuation
All HDSL2 Deployment Guidelines are met
HDSL2 DEPLOYMENT GUIDELINES
Cable pairs must be non-loaded
Total bridged tap < 2.5 kft
No single bridged tap >2 kft
196 kHz insertion loss 35 dB
Pulse attenuation (loss on HDSL2 Span Status Screen) 30 dB
Maximum loop resistance is 900
Impulse noises < 50 dBrn as measured using a 50 kb filter
Wideband noise 31 dBrn as measured using a 50 kb filter
For further information regarding deployment guidelines and applications, reference ADTRAN’s Supplemental Deployment Information for HDSL/HDSL2 document, P/N 61221HDSLL1-10.
HDSL2 TROUBLESHOOTING GUIDE
PRICING AND AVAILABILITY 800.827.0807
TECH SUPPORT 800.726.8663
RETURN FOR REPAIR 256.963.8722
www.adtran.com
61222003L2-22A
HDSL2 Loopback Control Codes
Name Code Comments
Arming (In-band) 11000 Signal sent in-band or over ESF data link. HDSL2 elements in disarmed Arming (ESF) 0001 0010 1111 1111 state make transition to armed state. Detection of either code results in
(12 FF Hex) Smartjack loop up, if NIU loopback is enabled. Activation 1101 0011 1101 0011 Signal sent in-band. HDSL2 elements in armed state make transition to (H2TU-C) (D3D3 Hex) loop up state. Loop up state timeout is programmable from the H2TU-C.
Activation 1100 0111 0100 0010 (H2TU-R) (C742 Hex) Deactivation 1001 0011 1001 0011 Signal sent in-band. HDSL2 element loop-up state makes transition to
(9393 Hex) armed state.
Disarming (In-band) 11100 Signal sent in-band or over ESF data link. HDSL2 elements in any state Disarming (ESF) 0010 0100 1111 1111 make transition to disarmed state.
(24FF Hex) Arming Timeout N/A 2 Hours
Loop-up Timeout N/A HDSL2 element in loop up makes transition to armed state.
Programmable from H2TU-C: None, 20, 60, or 120 minutes. Loopback Timeout 1101 0101 1101 0110 Signal sent in-band. Sets Loopback Timeout to NONE. Timeout will Override (D5D6 Hex) return to previous value when pattern is removed. Arming pattern
(11000) must precede this pattern. Span Power 0110 0111 0110 0111 Signal sent in-band. Disables span powering of remotes. Span power Disable (6767 Hex) will return when pattern is removed. Arming pattern (11000) must
precede this pattern.
Loading...