ADTRAN BR1 User Manual

JOBAID
TECHNICAL SUPPORT 800.726.8663
61152182L1-22A
9904
TRI-C DP/
BR1/10
CLEI:D4CIA9T2
Channel Position Pin Lead
127R
2T
229R
4T
331R
6T
433R
8T
535R
10 T
637R
12 T
739R
14 T
841R
16 T
943R
18 T
10 45 R
20 T
STATUS LED
STATUS RED No synchronization on either or both Total
Reach and T1 interfaces
GREEN Synchronizatin on both Total Reach and T1
interfaces
HARDWARE SWITCH SW1
SW1-1: B1 - along with SW1-2 and SW1-3,selects the service level SW1-2: B2
SW1-3: D
Service Option SW1-1 SW1-2 SW1-3
(B1) (B2) (D) 2B+D On On On 2B On On Off B1+D On Off On B2+D Off On On B1 On Off Off B2 Off On Off D Off Off On
SW1-4: Zero Byte Substitution (ZBS)
Enables or disables ZBS
Note: ZBS must be set the same as the U-BR1TE terminating the T1 carrier facility. For AMI-provisioned carriers, ZBS should be enabled. Setting is optional for B8ZS-provisioned carriers.
JOBAID
FOR COMPLETE I&M PRACTICE 877.457.5007
DOCUMENT # 094
HAVE YOUR FAX NUMBER AVAILABLE
TR ISDN
CLEI:DDRPLRC1AA
DEPLOYMENT GUIDELINES
TOTAL REACH SC PAM SIDE
Maximum Loop Loss .......................46 dB @ 20 kHz using a 135 ohm termination
52 dB @ 28 kHz using a 135 ohm termination
Maximum Noise................................34 dBrn using a 135 ohm termination with a 50 kB filter
Maximum DC Resistance.................2000 ohms
Maximum Single Bridged Tap...........2 kft
Maximum Total Bridged Tap..............6 kft
Maximum # of Bridged Taps..............3
Nominal Voltage.................................-130 VDC from TIP (GND) to RING (-130 v)
Note:Bridged Tap length must be included as part of the total loop length.
U-INTERFACE SIDE
Maximum Loop Loss .......................42 dB @ 40 kHz using a 135 ohm termination
Maximum Noise................................33 dBrn using a 135 ohm termination with a 50 kB filter
Maximum DC Resistance.................1300 ohms
Maximum Single Bridged Tap...........3 kft
Maximum Total Bridged Tap..............6 kft
Maximum # of Bridged Taps..............3
Voltage.................................-48 VDC from TIP (GND) to RING (-48 v)
T400 EDGE CONNECTOR PIN ASSIGNMENTS
55 TIP, U-Interface 49 RING, U-Interface 47 RING, Total Reach Interface 41 TIP, Total Reach Interface 27 Frame GND 11 Frame GND
Note:ISDN connections are not polarity sensitive
STATUS LEDs
NT1 I/F ON Indicates a loss of signal from or synchronization
with the 2B1Q BRI interface towards customer’s NT1.
FLASHING Once per second indicates receipt of a Near End
Block Error from the 2B1Q BRI interface.
TRI I/F
ON Indicates a loss of signal or synchronization with
the TRI-C (Total Reach ISDN CO) unit
FLASHING Once per second indicates receipt of a Near End
Block Error from the TRI-C unit
LOOPBACK
ON Indicates the TRI-R unit is in a 2B+D loopback
FLASHING Oncer per second for B1 loopback, twice per second
for B2 loopback
ACT
ON Indicates the terminal equipment has exchanged
ACT bits with the ISDN switch
FLASHING Once per second indicates that the ACT bit is being
sent from only the terminal equipment (CPE)
OPTIONS
S1-1 SX
ON Default and normal condition. Provides between 4 to 10 mA of sealing
current toward the customer’s NT1/TA.
OFF Disables sealing current to the customer’s NT1/TA.
S1-2 TEST
ON Used for factory test only. OFF Default and operational mode.
COMPATIBILITY