ADTRAN BR1 User Manual

BR1/10 2X MINI ISDN CHANNEL BANK
JOBAID
61150081L2-22A
0201
BR1/10 2X
CLEI: D4MEXZB02_ _
For a complete Installation and Maintenance Practice faxback: (877) 457-5007, Document # 662. Please have your fax number available.
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
COMMONS /OPTIONS
BR1/10 Common Unit required for each side of the 2X chassis H-LIU – Combination PAU/LIU P/N 1150179L1 CLEI: D4IMEG02AA
This unit replaces the individual PAU and LIU cards (shown).
PAU – Power/Alarm Unit P/N 1150078L2 CLEI: D4CIJ8Y2AA
This common unit has no options switches to set, verify the 1 AMP fuse is properly seated..
LIU - Line Interface Unit P/N 1150079L2 CLEI: D4CIPT02AA
The LIU has no option switches to set. The DB9 connector and rotary switches are used for testing only.
BCU- Bank Controller Unit P/N 1150080L1 CLEI: D4CIS7Z2AA
The BCU is the only common unit with option settings on the printed circuit board.
BCU Option Settings:
S1-1 through S1-3 DSX-1 Line Build Out: 0-133ft/133-266/266-399/399-533/533-655 S2-1 Line Code Format: B8ZS/AMI S2-2 Framing Format: ESF/SF S2-3 Remote Loopback Selection: PAYLOAD/LINE S2-4 and S2-5 Timing Mode:EXTERNAL/LOCAL/LOOP/CAU S2-6 Bank Mode: 8DSL/10DSL S2-7 through S2-9 Terminal Mode: D4/ D1D/SLC Mode 1D1D/SLC Mode 3 D4/ D1D
Mini U-BR1TE Switch Options
ON OFF
SW1 B1 SER. ON B1 SER. OFF SW2 B2 SER. ON B2 SER. OFF SW3 D SER. ON D SER. OFF SW4 SC ON S.C. OFF SW5 LULT LUNT SW6 LULT LUNT SW7 ZBS ON ZBS OFF
Faceplate LED on mini U-BR1TE Red- Indicates no sync to ISDN Switch/NT1 Green- Indicates sync to ISDN Switch/NT1
BCU MANUAL TESTING DIP SWITCHES
LB ON/OFF Enables and disables DS1 loopbacks for REMOTE/LOC
direction depending on switch setting below
REMOTE/LOC REMOTE in ESF will initiate a loopback to the far-end BR1/10
side when LB is switched to ON REMOTE in SF will initiate a loopback at the local BR1/10 side when LB is switched to ON LOC provides internal loopback at the T1 data stream at the local BR1/10 side when LB is switched to ON
DS0/DS1 When set towards DS1 controls the REMOTE/LOC loopback
directions and initiates loopback with LB ON/OFF switch When set towards DS0 controls the B1/B2 channel selection. The TEST recessed button initiates test selected on LIU rotary switches. This option is normally in the DS0 position once the BR1/10 side is in service
B1/B2 When the switch above is in the DS0 position, B1 and B2
selects the appropriate B-Channel to be tested
Mini U-BR1TE Compatible Access Cards
Mini BR1/10 ISDN U-BR1TE 1150077LX CLEI: D4C1A2T2AA (Shown) Mini BR1/10 TR ISDN UBR1TE 1152182LX CLEI: D4CIA9T2AA Mini BR1/10 TR DDS DP 1151061LX CLEI: D4D3M14DAA Mini BR1/10 DSO DP 1150103L1 CLEI: D4D3D3HDAA
BR1/10 Slot to Channel Bank Slot Cross-Reference Compatibility
BR1/10 12345678910
D4/DID, SLC Mode 3 1471013161922N/AN/A
SLC Mode 1 (Physical Slots) 1245781011N/AN/A
Digroup-A 1/2 3/4 7/8 9/10 13/14 15/16 19/20 21/22 N/A N/A
Digroup-B 25/26 27/28 31/32 33/34 37/38 39/40 43/44 45/46 N/A N/A
Digroup-C 49/50 51/52 55/56 57/58 61/62 63/64 67/68 69/70 N/A N/A
Digroup-D 73/74 75/76 79/80 81/82 85/86 87/88 91/92 93/94 N/A N/A
SLC Mode 3 (Physical Slots) 1471013161922N/AN/A
Digroup A/B 25/26 31/32 37/38 43/44 1/2 7/8 13/14 19/20 N/A N/A
Digroup C/D 73/74 79/80 85/86 91/92 49/50 55/56 61/62 67/68 N/A N/A
BCU LEDs
Indicator Color Description
AY Amber ON indicates a Yellow Alarm is being received from the T1 carrier facility AR Red ON indicates the BR1/10 side is in a Red Alarm condition TP Amber ON indicates Trunk Processing is active on all U-BRITEs (10) RCV Red ON indicates a loss of framing of T1 signal from the T1 carrier facility ESF Green ON indicates the T1 Extended SuperFrame format is selected SF Green ON indicates the T1 SuperFrame format is selected B8ZS Green ON indicates T1 B8ZS line coding is selected AMI Green ON indicates T1 AMI line coding is selected 10DSL Green ON indicates D Channel 4:1 TDM mode is selected to transport 10 BRIs 8DSL Green ON indicates TR-397 3-DS0 framing across the T1 facility to transport 8 BRIs EXT Green ON indicates External timing input is selected (BITS) LOC Green ON indicates BR1/10 side is using a locally generated clock source to time the
T1 network LOOP Green ON indicates BR1/10 clock is recovered clock from the T1 network CAU Green ON indicates clock is recovered from the DSL position #1 to time the T1 network DS1-LOC Green ON indicates the BR1/10 side is in a Local DS1 Loopback RMT Green ON indicates the unit has initiated remote DS1 loopback when set in ESF mode
FLASHING indicates it responded to remotely commanded loopback, or has
provided a loopback path for the T1 data-stream in SF mode LP-SYNC* Red ON indicates the U-interface is out of sync for the selected channel unit LP-CRC* Red In normal operation flashes upon receiving NEBEs from the loop. In Local PM
mode flashes 6-19 CRCs and is solid when >20 CRC errors are detected from the
loop CR-SYNC* Red ON indicates no TR-397 framing across the T1 carrier for the selected channel CR-CRC* Red In normal operation flashes upon receiving NEBEs from the T1 carrier. In Local
PM mode flashes 6-19 CRCs and is solid when >20 CRC errors are detected
from the T1 DS0-LB* Amber ON indicates the selected U-BRITE is in a 2B+D commanded eoc loopback.
Flashing once per second=B1 is looped, flashing twice per second=B2 is looped ACT* Green ON indicates the customer’s NT1 has successfully exchanged ACT bits with the
network for the selected channel
* Status is for the channel unit selected on the DSL 10-position rotary switch on the LIU of the the BR1/10 side
WARRANTY
Warranty for Carrier Networks products manufactured by ADTRAN and supplied under Buyer’s order for use in the U.S. is ten (10) years. For a complete faxback copy of ADTRAN’s U.S. and
Canada Carrier Networks Equipment Warranty, call (877) 457-5007, Document #414.
PRICING AND AVAILABILITY 800.827.0807
TECH SUPPORT 800.726.8663
RETURN FOR REPAIR 256.963.8722
www.adtran.com
61150081L2-22A
BR1/10 2X MINI ISDN CHANNEL BANK
LOOPBACK TEST (ADR6, NT1)
Loopbacks in the network to customer direction can be initiated from either the ISDN switch (eoc) or the BR1/10 LIU and BCU. The down-stream direction is automatically selected based on the channel unit position in the circuit. To initiate a loopback, perform the following steps:
1. Insert TX and RX bantam plugs of the DS0 digital test set (i.e. TPI 108/109) to the TEST jacks of the LIU
2. Connect test set clock interface to DB9 connector of the LIU and configure the test set for Near Logic and 64kb/s
3. Select the desired U-BRITE using the DSL rotary switch on the LIU( the selected U-BRITE LED flashes red and green for 3 seconds
4. Select the desired loopback address using the address rotary switch on the LIU (note: ADR1 is always the U-BRITE your test set is connected to
5. Select DS0 option and select the desired Bearer channel B1/B2 dip switches on the BCU
6. Press the recessed TEST push-button on the BCU to initiate the loopback test
7. The DS0 LB status LED on the BCU will illuminate if the loopback is successful and will not
illuminate if the loopback failed
8. Send and Receive 2047 to the established loopback and observe the DS0 digital test set for bit errors
9. It is not necessary to exit the test mode to select additional addresses (ADR2, NT1) or to change to B1/B2 channels
10. To terminate the loopback, press the TEST push-button and the amber DS0-LB LED will go out
BCU DIP Test Switch
Channel Selection
LIU
1150079L
T E S T
DB-9 Connector
Bantam Jacks
1
2
10
2
9
3
4
8
5
7
6
CRTX
LPBX
LPTX
AD
NT1
R6 AD
AD
R5
R1
ADR4
ADR2
ADR3
IN
M O N
O
U
T
REMOTE
LB ON
1 2 3 4
AY
OFF
AR
LOC
DS0
TP
RCV
DS1
B2
ESF
B1
SF
TEST
DS1-LOC
LP-SYNC
CR-SYNC
BCU
DSO-LB
B8ZS
AMI
10DSL
BDSL
EXT
LOC
LOOP
CAU
RMT
CRC
CRC
ACT
115
00
8
0
L
1
ON
5 6 7 8 9 10
4
1 2 3
Recessed Test Push Button
Loopback Address