ADTRAN Atlas 830 User Manual

For more detailed documentation, visit us online at www.adtran.com
Quick Start Guide
Reviewing the Front Panel
ATLAS 830 P/N 1200780L1 (AC)/1200781L1 (DC)
Network Ports LEDs
Controller LEDs
NE TW O RK
1
OK
TEST
ERROR
ALARM
2
OK
TEST
ERROR
ALARM
STATUS
ONLINE
TEST
ACO Switch
POWER
SYSTEM
ETHERNET
REMOTE
ACO
CRAFT
Craft Interface
Connecting to the ATLAS 830
Connecting a VT100 terminal (or VT100 terminal emulator) to the C interface (on the front panel of the unit) or the A
interface (on the rear panel
DMIN
of the unit) allows access to the terminal menus and management features of the ATLAS 830.
Perform Steps Below in the Order Listed:
1. Configure a VT100 terminal (or terminal emulation software) with the following settings:
Data Rate: 9600 baud Stop Bits: 1 Data Bits: 8 Flow Control: None Parity Bits: None
If the terminal has a parallel setting, disable it and use serial.
2. Connect the DB-9 male end of the data cable into the ATLAS 830 C
port. Make the connection to the VT100 terminal as appropriate for
DMIN
A
your connection.
RAFT
RAFT
or
Option Module LEDs
1
MODULES
3
5
2
4
7
6
8
ATLAS 830
Craft Pinout
PIN NAME DESCRIPTION
1, 4, 6-9 N/A Not Connected
2 RD Receive Data (output) 3 TD Transmit Data (input) 5 SG Signal Ground
System Status LEDs
The System Status LEDs display the status of the power supply, controller, and other system parameters for the ATLAS 830. For a more detailed discussion of the front panel LEDs, refer to Section 2, Engineering Guidelines, of the ATLAS 830 System Manual.
LED Description
Power Indicates the status of the power supply
System Indicates the status of the unit controller and other system parameters.
Ethernet Indicates the status of the ethernet port.
Remote Indicates whether a user (Telnet or VT100) is logged in to the unit.
3. Initiate a terminal session and the L
screen displays. The default
OGIN
password is password. (Passwords in the ATLAS 830 are case sensitive.)
Quick Start Guide, 61200780L1-13A, August 2002 Technical Support 1-888-4ADTRAN (1-888-423-8726) Copyright 2002 ADTRAN, All Rights Reserved
For more detailed documentation, visit us online at www.adtran.com
Quick Start Guide
ATLAS 830 P/N 1200780L1 (AC)/1200781L1 (DC)
Reviewing the Rear Panel Design
Alarm Relay Connection
Admin Interface
Admin Pinout
PIN NAME DESCRIPTION
1 DCD Data Carrier Detect (output) 2 RD Receive Data (output) 3 TD Transmit Data (input) 4 DTR Data Terminal Ready (input) 5 SG Signal Ground 6 DSR Data Set Ready (output) -- not connected 7 RTS Request to Send (input) 8 CTS Clear to Send (output) 9 RI Ring Indicate (output) -- not connected
10/100BaseT Ethernet Pinout
PIN NAME DESCRIPTION
1 TX1 Transmit Positive 2 TX2 Transmit Negative 3 RX1 Receive Positive
4,5 Unused
6 RX2 Receive Negative
7, 8 Unused
T1/PRI Monitor Jacks
Option Module Slots
Network T1/PRI Ports
Optional DC Power Supply P/N 1200229L1
CAUTION: FOR CONTINUED PROTECTION
AGAINST RISK OF FIRE, REPLACE
ONLY WITH SAME TYPE AND RATING
OF FUSE.
ON
OFF
12A/125V
-
+
48 VDC, 6A
USE COPPER
CONDUCTORS ONLY
SEE MANUAL BEFORE
REMOVING POWER SUPPLY
Power Supply Slot
Alarm Relay Connection Pinout
PIN NAME DESCRIPTION
1 Normaly Closed (NC) Opens when a selected alarm condition is present. 2 Normally Open (NO) Closes when a selected alarm condition is present. 3 Common (COM) Common connection between external circuitry
and NC or NO terminal.
4 Chassis Ground (GND)
DC Power Supply Connection (Optional P/N 1200229L1)
PIN NAME DESCRIPTION
1 + Ground (GND) 2--48VDC
Quick Start Guide, 61200780L1-13A, August 2002 Technical Support 1-888-4ADTRAN (1-888-423-8726) Copyright 2002 ADTRAN, All Rights Reserved
Loading...