QUAD USSI MODULE P/N 1200261L1
NSTALLATION INSTRUCTIONS
I
PECIFICATIONS
S
For more detailed documentation, visit us online at www.adtran.com
1. Remove the cover plate from the appropriate option slot in the ATLAS
800 Series rear panel.
2. Slide the Quad USSI Module into the option slot until the module is
firmly positioned against the front of the chassis.
3. Secure the thumbscrews at both edges of the module. Tighten with a
screwdriver.
4. Connect the cables to the associated device(s).
5. Complete installation of remaining modules and Base Unit as specified
in the Installation chapter of the ATLAS 800 Series System Manual.
Quick Start Guide, 61200261L1-13A, April 2001 Technical Support 1-888-4ADTRAN (1-888-423-8726) Copyright 2001 ADTRAN, All Rights Reserved
DTE Interface EIA-530, EIA-530A Synchronous
RS-449
RS-232 Synchronous
CCITT X.21 (V.11)
Rates 56 kbps to 2.048 Mbps in 56k or 64k steps
Tests Local Loopback (Bilateral)
Remote Loopback (V.54)
Self-Test
T est Pattern 511 with errored seconds display and error inject
capability
1s Density Protection Forces 1s to network after one second of
consecutive zeros from DTE
Connectors DB-78 with cables to convert to D sub female
connectors
QUAD USSI MODULE P/N 1200261L1
Flow Budget
DTR
DSR
Alarm Status Port PLL
TD Tx Frames
RD Rx Bytes
EC Tx Bytes
Rate RI Rx Frames
Data Rate Port DCD Port
Inband Stats Tx Accept
RXF Tx Reset
TXE Link Verify
PLL/Fifo RXE Rx Overflow
PLL/Fifo Port Lock Poll Skips
Prt TXF Remote Fail
Name Link Verify Ack
Clk +/- Normal Reset Stats
Inverted
Inverted
Data Normal
CTS Forced On
Normal Normal
DCD Forced On
Normal
DSR Forced On
Configuration Remote RTS
Connect on DTR
Remote DTR
DTR Ignore
Zero Inhibit On
Off
Off
Inband On
Off
Send Leads On
Port
Mode Persistent
Source ID
Number
Prt No Loopback
Loopback Local Loopback
Dial Dial One Time
Test LB Status Remote Loopback
Off Sync: Y
511 On
511 Result Sync: N
Auto
Inject *
Clr ES
EIA-530,
RS-449, V.36
X.21
RS-232
Prt V.11
Current DTE Type
DTE Interface DTE Ifce Mode EIA-530A
Module Alar ms (shortcut
to Alarms)
Slt Info Part Number
Type USSI Serial Number
Menu Board Revision SLIP
Alarm
State Online NO EXT CLK
Status Offline DTE Status Prt RTS PKT EP ALM
Rev DTE Status CTS
Modules Test Alarms ZERO
Te st Activity (shortcut to
Test)
Quick Start Guide, 61200261L1-13A, April 2001 Technical Support 1-888-4ADTRAN (1-888-423-8726) Copyright 2001 ADTRAN, All Rights Reserved