For more detailed documentation, visit us online at www.adtran.com
Quick Start Guide
LINK/SPEED
ETWORK CONNECTION PINOUT
N
12 435687
ETHERNET SWITCH OPTION MODULE P/N 1200766L1
ETHERNET SWITCH
500 Series
NSTALLATION INSTRUCTIONS
I
1. Remove the cover plate from the appropriate option slot in the ATLAS
550 Base Unit.
2. Slide the Ethernet Switch Option Module into the option slot until the
module is firmly positioned against the front of the chassis.
3. Secure the thumbscrews at both edges of the module. Tighten with a
screwdriver.
4. Connect the cables to the associated device(s).
5. Complete installation of remaining modules and Base Unit as specified
in the Installation chapter of the ATLAS 550 System Manual.
PECIFICATIONS
S
Pin Name Description
1 TX1 Transmit Positive
2 TX2 Transmit Negative
3 RX1 Receive Positive
4, 5 UNUSED —
6 RX2 Receive Negative
7, 8 UNUSED —
Quick Start Guide, 61200766L1-13A, August 2002 Technical Support 1-888-4ADTRAN (1-888-423-8726) Copyright 2002 ADTRAN, All Rights Reserved
Interface Type: (8) 10BaseT/100BaseTX interfaces with auto MDI/MDIX
crossover on all interfaces
Flow Control: Back-pressure flow control on all half-duplex interfaces
Pause-frame flow control on full-duplex interfaces
Environmental
Specifications:
Compliance: FCC Part 15, Class A
Operating Temperature: 0°C to 45°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95% non-condensing
UL 60950, 3rd Edition
EN 60950
ETSI 300 386
Quick Start Guide
ENU TREE
M
Modules Alarm
ETHERNET SWITCH OPTION MODULE P/N 1200766L1
Part Number
Slt Info Serial Number
Type Assembly Revision
Menu (ENET-8)
Te st Port (1-8)
State Online Status
Rev Offline Link Status Link Up
Link Down
N/A
Speed 10 Mbps
100 Mbps
Quick Start Guide, 61200766L1-13A, August 2002 Technical Support 1-888-4ADTRAN (1-888-423-8726) Copyright 2002 ADTRAN, All Rights Reserved