H2TU-C for Litespan® Using Narrowband/Wideband Pairs
61221002L1-22D
0607
HDSL2
H2TU-C
P/N: 1221002L1
CLEI: SLL6211D_ _
H TUC
1221002L1 NB/WB
DSL
STAT
RLOS
HLOS
HCRC
ARM
LBK
B8ZS
AHDSL2
*61221002L1-22D*
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
©2006 ADTRAN, Inc.
All Rights Reserved.
FRONT PANEL LED INDICATORS
DSL z Green............... HDSL2 SNR quality is optimum (6 dB or higher)
z Yellow ............. HDSL2 SNR quality is marginal (1-5 dB)
z Red .................. HDSL2 SNR quality is poor (0 dB)
2 Flashing .......... HDSL2 Pulse Attenuation is >30 dB
STAT { Off ................... Indicates loss of power to the H2TU-R
z Green............... Normal operation; HDSL2 synchronized with H2TU-R
2 Flashing Green Acquiring HDSL2 synchronization with H2TU-R
z Red .................. Failure indication; unable to start/load firmware
RLOS { Off ................... DS1 signal from CPE is present at H2TU-R
z Red ................... DS1 signal from CPE is absent at H2TU-R or framing
does not match
HLOS { Off ................... HDSL2 synchronization achieved
z Red .................. HDSL2 loss of synchronization
2 Flashing Red ... DC continuity fault detected on HDSL2 loop
HCRC { Off ................... No HDSL2 CRC errors within last 30 minutes
z Yellow ............. Four or more HDSL2 CRC errors in last 30 minutes
z Red .................. HDSL2 CRC errors are being detected
ARM/LBK{ Off ................... No loopback active
z Green............... Loopback is active on this module
z Yellow ............. Module is armed but loopback is not active
B8ZS { Off................... AMI line code
z Green............... B8ZS line code
CARD EDGE PINOUT
ADTRAN® uses negative ground-referenced span powering voltage (–190 VDC) on
the HDSL2 loop. H2TU-R span powering can be disabled to allow locally powered
H2TU-R applications, if desired.
H2TU-C for Litespan plugs directly into a Litespan channel bank assembly channel
unit slot. Litespan system software must be version 11.0.0 or higher. The tip and ring
connections from the H2TU-C to the shelf are made through card edge pins:
♦ Narrowband Tip - Pin A3
♦ Narrowband Ring - Pin A4
NOTE: If the Litespan AHDSL2 is used in applications where narrowband and
wideband copper service wire pairs are connected simultaneously, only one
service pair can have terminating equipment connected to the H2TU-C.
Also, copper service wire pairs not in use are considered as bridge taps to
the HDSL2 loop in service and should be entered into the deployment
calculations listed in Section 4 of this practice. If the bridged taps presented
by the unused loop violates the CSA guidelines, the unused pair should be
disconnected.
CAUTION: Do not deploy a Litespan AHDSL2 into any Litespan Channel Bank
Assembly slot that has ADSL Power Distribution Fuse and Alarm
(PDFA) connections to Wideband pairs of the Channel Bank Assembly.
Litespan is a Registered trademark of Alcatel, Inc., Paris, France.
For more information, refer to the Installation and Maintenance Practice (P/N 61221002L1-5) available online at www.adtran.com.
♦ Wideband Tip - Pin C7
♦ Wideband Ring - Pin C8
INSTALLATION
After unpacking the unit, inspect it for damage. If damage is noted, file a claim with
the carrier and then contact ADTRAN. Refer to Warranty.
To install the H2TU-C for Litespan, perform the following steps:
1. If present, remove the Access Module Blank from the appropriate access module
slot of the chassis.
2. Pull the ejector latch, located on the lower right-hand side of the H2TU-C for
Litespan front panel, from its closed position.
3. Hold the H2TU-C for Litespan by the front panel while supporting the bottom
edge of the module with the ejector latch opened to engage the chassis edge.
Align the module edges to fit in the lower and upper guide grooves for the access
module slot.
4. Slide the module into the access module slot. Simultaneous thumb pressure at the
top and at the bottom of the module ensures that the module is firmly positioned
against the backplane of the chassis. Secure the module in place by pushing up
and in on the ejector latch.
When installed, the H2TU-C for Litespan runs a series of self-tests. Once the selftests are complete, the status LEDs reflect the true state of the hardware.
TROUBLESHOOTING GUIDE
Condition Solution
At power up, all
front panel
indicators are
off
The STAT LED
remains Red.
The STAT LED
is off, but the
HLOS LED
remains Red
The STAT LED
is off, but the
RLOS LED
remains Red.
1. Verify that the channel bank or ONU BPS power LEDs are on.
2. Make sure that unit is fully and correctly inserted into the channel bank or ONU.
3. If step 1 fails, contact Alcatel customer service (800-848-0333). If step 1 passes,
but step 2 fails, replace the H2TU-C.
1. Verify that the channel bank or ONU BPS power LEDs are on.
2. Verify that the equipment type for the Litespan H2TU-C slot is AHDSL2. Using
TL1, equipment type is shown with the command rtrv-eqpt::AID, where AID is
the access identifier (i.e., cot-1-15).
3. If step 1 fails, contact Alcatel customer service. If step 1 and step 2 pass, replace
the H2TU-C. If step 1 passes but step 2 fails, delete the equipment record (i.e., dlteqpt::cot-1-15 with TL1) and reinsert the card, or equip the slot with the currently
reserved equipment type.
1. Confirm that the HDSL2 loop is not open.
2. Confirm that the HDSL2 loop is not shorted.
3. Verify the loop conforms to CSA guidelines and is not too long. Loop loss at 196
kHz should be less than 35 dB.
4. Verify that the HDSL2 loop has acceptable noise limits.
5. Verify that tip and ring of each HDSL2 loop belongs to the same twisted pair.
6. If steps 1 through 5 pass, but the
7. If step 6 fails, replace the H2TU-R.
1. Check that framing line coding are set appropriately for T1 data at the H2TU-R.
2. Check that the
3. If step 1 fails, change the appropriate framing and line coding. If step 1 passes, but
step 2 fails, a problem may exist at the H2TU-R T1 interface. If the problem does
not exist at the T1 interface, replace the H2TU-C.
RLOS LED at the H2TU-R is off.
HLOS LED remains red, replace the H2TU-C.
Compliance
Code Input Output
Power Code (PC) F C
Telecommunication Code (TC) – X
Installation Code (IC) A –
H2TU-C for Litespan Using Narrowband/Wideband Pairs
PRICING AND AVAILABILITY 800.827.0807
TECH SUPPORT 800.726.8663
RETURN FOR REPAIR 256.963.8722
www.adtran.com
61221002L1-22D
PROVISIONING OPTIONS / LOOPBACK FUNCTIONS
Upon initial insertion of the Litespan H2TU-C into the Litespan system, the H2TU-C is provisioned
with the configuration data stored in the shelf controller. The H2TU-C should be pre-provisioned as
indicated under “Pre-Configuration Value” in the table below. The loopback function codes are shown
at right.
H2TU-C
Options
Line Code LINECDE AMI
1
Framing
NIU Loopback NIDLPBK Disabled
Loopback
1
Timeout
DS1 TX Level AT 0
New England
Loopback
Latching
Loopback
Span Power LP Disabled
Customer Loss
Indicator
PRM Setting LPBKACTC None
Network Keep
Alive
1. Some settings may not be available at the H2TU-R.
2. This option is only available if the H2TU-R P/N 1221026L1, 1222026L1, 1223026L1 is used in the circuit.
3. This option is not available if the H2TU-R P/N 1221026L1, 1222026L1, 1223026L1 is used in the circuit.
Corresponding
Litespan Parameter
FMT SF
LBKTMO 0
LPBKACTR Disabled
1,2
FT1MODE T1
LPBKDEACTCDE AIS
3
NTWKKPALV Disabled
H2TU-C
Available Setting
B8ZS
ESF
Unframed
Auto
Enabled
20 Minutes
60 Minutes
120 Minutes
–7.5 dB
–15 dB
Enabled
FT1
Enabled
AIS/CI
Loopback
SPRM
NPRM
Auto (Both)
Enabled
Corresponding
Litespan Setting
AMI
B8ZS
SF
ESF
UNFR
AUTO
NO
YES
0
20
60
120
0.0
–7.5
–15
0000000000000000
0000000000000001
NO
YES
SINK
SOURCE
0000000000000000
0000000000000001
0000000000000010
0000000000000000
0000000000000001
0000000000000010
0000000000000011
NO
YES
Pre-Configurable
Value
B8ZS
AUTO
YES
120
0.0
0000000000000000
NO
SOURCE
0000000000000001
0000000000000001
NO
Function/Code Response
(1)
1 in 3
(100)
(1, 2)
(2)
(1, 2, 4)
(1)
(1)
(1)
(1)
(known
(1)
(1, 2, 4)
1 in 6 (100000)
4 in 7 (1111000) Loops back data from network toward network in the H2TU-C
6 in 7 (1111110) Loops back data from customer toward customer in H2TU-C
1111 1111 0001 1110 Loops back data from network toward network at H2TU-C (FF1E HEX)
0011 1111 0001 1110 Loopback data from customer toward customer at H2TU-C (3F1E HEX)
Arm/ 11000 (known as
2-in-5 pattern)
Arm/ FF48
(1111 1111 0100 1000)
Disarm/ 11100
as 3-in-5 pattern)
Disarm/ FF24
(1111 1111 0010 0100)
H2TU-C Network Loop up
/ D3D3
(1101 0011 1101 0011)
H2TU-R Address 20 for
extended demarc / C754
(1)
(1100 0111 0101 0100)
Loop down / 9393
(1001 0011 1001 0011)
Query Loopback / D5D5
(1, 2)
(1101 0101 1101 0101)
Query Loop Parameters/
DBDB
(1101 1011 1101 1011)
Loopback Time Out Override / D5D6
(1101 0101 1101 0110)
Span Power Disable /
6767
(0110 0111 0110 0111)
Note: All codes listed above must be sent for a minimum of 5 seconds in order for them to be detected and acted upon.
1. The H2TU-C and H2TU-R individually detect and act upon in-band loopback control codes. Depending on which list
number of H2TU-R is used with the Litespan H2TU-C, some of these control codes may not cause action (such as loop
up, error injection, etc.) at the H2TU-R. Refer to the H2TU-R documentation for supported control codes.
2. Modules must be armed with 11000b or FF48h for this code to function.
3. In order to behave like a NIU, the H2TU-R can not loop down from the network side with 9393h.
4. This code can be detected only if the modules are armed OR if any loopbacks are active.
5. If NIU is enabled, then the H2TU-R can be in network loopback when the H2TU-C or H2R loop up codes are sent.
Loop down everything
If armed, Loops back at the H2TU-R toward the network.
Loops the H2TU-R toward the network and arms the H2TU-C. No AIS or errors are sent. When
sent from the customer, this code arms all modules.
This pattern is sent on ESF FDL. When sent from network, all modules are armed and the
H2TU-R is looped back toward network. This code has no functionality when sent from the
customer.
All modules are removed from the armed state and looped down when the 11100 pattern is
received. The LBK LEDs turn off on all modules.
This pattern is sent on ESF facility data link, and disarms and/or loops down all modules.
If the modules have been armed and no modules are in loopback
toward the network, 2 seconds of AIS (all 1s) are sent, 5 seconds of data pass, and then 231 bit
errors are injected into the DSX-1 signal. As long as the pattern continues to be sent, 231
errors are injected every 20 seconds. When the pattern is removed, the module remains in
loopback. If the pattern is reinstated, the injection of 231 bit errors resumes at 20-second
intervals.
When sent from the network, an H2TU-R network loopback is activated and a 200-bit error
confirmation is sent. 2 seconds of AIS (all 1s) is sent, 5 seconds of data pass, and then 200 bit
errors are injected into the DSX-1 signal. As long as the pattern continues to be sent, 200
errors are injected every 20 seconds. The HDSL2 office unit does not block transmission of farend NIU loopback from the customer premise (H2TU-R).
(1, 3)
All modules currently in loopback loop down, but remain in the armed state.
If the modules are armed and the H2TU-C or H2TU-R are in network loopback, errors are
injected into the DSX-1 signal upon detection of the query loopback pattern. As long as the
pattern continues to be sent, errors are injected again every 20 seconds. The number of errors
injected each time depends on which unit is in loopback. 231 errors are injected if the H2TU-C
is in network loopback and 20 at a time if the H2TU-R is in network loopback.
If the units are armed and the H2TU-C is in network loopback, errors are injected into the
DSX-1 signal upon detection of the query loop parameters pattern. As long as a pattern continues to be sent, errors are injected again every 20 seconds. The number of errors injected each
time depends on the current status of signal quality and pulse attenuation parameters on each
loop.
111 errors are injected if all HDSL2 receiver points (H2TU-C, and H2TU-R) indicate pulse
attenuation is 30 dB or lower and signal quality (margin) is 6 dB or higher.
11 errors at a time are injected if any of the receiver points indicate pulse attenuation is greater
than 30 dB and/or signal quality (margin) is less than 6 dB.
If the units are armed and this pattern is sent, the loopback time out is disabled. The time out
option is updated to NONE on the PROVISIONING menu of the H2TU-R screens (viewable
through the RS-232 port). As long as the units remain armed, the time out remains disabled.
When the units are disarmed, the loopback time out returns to the value it had before the
D5D6 code was sent.
If the units are armed and this pattern is sent, the H2TU-C deactivate the span power supply,
removing power to the H2TU-R. As long as the pattern continues to be sent, the span power
supply remains disabled. When the pattern is discontinued, the H2TU-C reactivates its span
power supply, returning power to the remote unit. All units retrain and return to the disarmed
and unlooped state.
(5)
, the H2TU-C loops up
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service.
Warranty information can be found online at www.adtran.com/warranty
.