ADTRAN 19 User Manual

JOBAID
61212082L1-22C
0101
TR ISDN
CLEI: DDRPLRC1_ _
STATUS LEDs
OFFICE I/F RED Indicates a loss of signal from or synchronization
with the 2B1Q BRI interface toward the switch
Block Error from the 2B1Q BRI interface toward the switch
TRI I/F RED Indicates a loss of signal from or synchronization
with the TRI-R (Total Reach ISDN Remote) unit
Block Error from the TRI-R unit
TEST YELLOW Indicates the TRI-C unit is in a network
commanded 2B+D loopback
FLASHING Indicates that the TRI-C is in a network commanded
loopback or that a downstream unit has been placed in loopback from the faceplate of the TRI-C. Once per second for B1 loopback, twice per second for B2 loopback
ACT GREEN Indicates the terminal equipment has exchanged
ACT bits with the ISDN switch
FLASHING Once per second indicates that the ACT bit is being
sent from only the terminal equipment (CPE)
MFT ADAPTER WIRING (where approved)
T400 MFT SIDE
TIP TRI-C pin 55 pin 14 TIP 1 side B
RING TRI-C pin 49 pin 13 RING 1 side B
TIP CO pin 41 pin 17 TIP side A
RING CO pin 47 pin 19 RING side A
–48 (supply) pin 35 pin 11 –48 V
–48 (return) pin 17 pin 18 Ground Frame GND pin 11 pin 1 Chassis Ground Frame GND pin 27
T400 EDGE CONNECTOR PIN ASSIGNMENTS
55 TIP, TR-Interface To Customer 49 RING, TR-Interface To Customer 47 RING, U-Interface From ISDN Switch 41 TIP, U-Interface From ISDN Switch 35 –VDC Supply 27 Frame Ground 17 –VDC Return 11 Frame Ground
Note: ISDN connections are not sensitive to TIP/RING reversals.
OPTIONS
S1-1 CTONE
ON Enables continuous periodic wake-up tones to the ISDN switch or LULT device.
Wake-up tones are repeated at 17-second intervals.
OFF Default and normal condition, in that the TRI-C sends one wake-up tone on power-up
only.
S1-2 TEST
ON Used for factory test only.
OFF Default and normal mode.
LOOPBACK TEST (ADR1 – ADR4, NT1)
Loopbacks in the network to customer direction can be initiated from either the ISDN switch (e.o.c.) or from the faceplate of the TRI-C. Loopbacks initiated from the faceplate are non-intrusive to the other B and D channels. To initiate a loopback, perform the following steps:
1. Connect the DS0 digital test set (e.g., TPI 108/109) to the 8-pin RJ-45 jack of the TRI-C and configure the set for Near Logic and 64 kb/s.
2. Rotate the 8-position rotary switch clockwise or counterclockwise for B1 or B2 selection respectively, to the desired address.
3. The TEST LED will illuminate if the loopback is successful and will not illuminate if the loopback fails.
4. Send and receive 2047 pseudo-random data to the established loopback and observe the DS0 digital test set bit error count.
5. It is not necessary to exit the test mode to select additional addresses or to change the B1/B2 channel (CW, CCW ).
6. To terminate the loopback, remove the 8-pin modular ring and return the rotary switch to the
unused position (between OFC TX and ADR4).
Note: The rotary switch is only intrusive if a DS0 test set is connected to the 8-pin modular interface of the TRI-C. If a test set is not connected, the rotary switch does not function. The 8-pin connector should be male with all 8 pins straight-through (no crossovers).
COMPATIBILITY
TOTAL REACH®ISDN
2ND GENERATION CENTRAL OFFICE UNIT
REMOTE
UNIT
CENTRAL
OFFICE UNIT
DDRPLKC1AA
DDRPMLC1AA
NANIDCBCAA (NID)
SYNCLOSS
NT1
CRC SYNCLOSS CRC MARGIN LOOPBACK
ACT
POWER
TR
1212083L1
TRTX
ADR1ADR3
NTI
B2
B1
ADR4
NTWKTX
ADR2
SYNCLOSS
NTWK
CRC SYNCLOSS CRC MARGIN LOOPBACK ACT POWER
TR
1st Generation
TRI-R
1st Generation
TRI-C
DDRPLRC1AA
DDRPMLP1AA
NDMMFHO1RA (NID)
1212083L1
TRTX
ADR1ADR3
NTI
B2
B1
ADR4
NTWKTX
ADR2
OFFICEI/F TRII/F TEST ACT
2nd Generation
TRI-R
2nd Generation
TRI-C
OFFICEI/F TRII/F TEST ACT
1212082L1
–190 VDC
–190 VDC
–130 VDC
C A U T I O N
SUBJECT TO ELECTROSTATIC DAMAGE
HANDLING PRECAUTIONS REQUIRED.
C A U T I O N
OR DECREASE IN RELIABILITY.
!
PRICING AND AVAILABILITY 800.827.0807
TECH SUPPORT 800.726.8663
RETURN FOR REPAIR 256.963.8722
www.adtran.com
61212082L1-22C
For complete Installation and Maintenance: (877) 457-5007, Document #374 (P/N1212082L1) and #338 (P/N 1212083). Please have your fax number available.
DEPLOYMENT GUIDELINES
All loops must be non loaded
Actual Measured Loss (AML) not to exceed 52 dB @ 20 kHz (135 termination) or 61 dB @ 40 kHz.
Loop length not to exceed 50 kft.
Maximum single bridged tap not to exceed 2 kft.
Maximum total bridged tap not to exceed 6 kft.
Maximum DC resistance not to exceed 2000 Ω.
WIRING CONNECTIONS
TURNUP
1. Set dip switches on both units according to circuit design and local practices.
2. Install both TRI-C and TRI-R using standard procedures. a) TRI-C inserts in T400 shelf, or MFT bay with MFT adapter. b) TRI-R inserts in standard non powered T200 or T400 NCTE mounting for indoor
installations, or mounts to a wall for outdoor NID installations.
3. When inserted in an active housing the two units go through a synchronization and activation
process during which all LEDs undergo an on/off sequence. Refer to STATUS LEDs on reverse side for LED descriptions.
4. After synchronization, which may take up to 90 seconds, the following LED indication will show: a) ACT LED – ON b) All other LEDs will be OFF until network occurrences cause illumination.
5. If LEDs in step 4 are as noted, proceed with loopback and BERT testing per specifications.
6. If LEDs in step 4 are in any other configuration, refer to
Troubleshooting.
7. The TRISDN system will be qualified at the 20 kHz frequency.
TOTAL REACH ISDN
REMOTE UNIT
Pair Terminal T400 Customer
Designations Pin # RJ-48
To/From Network TT, RR 41, 47 – To Customer T, R 55, 49 4, 5
TROUBLESHOOTING
No Power at the TRI-R
Ensure TRI-C is supplying voltage to power the TRI-R. Measure T-R voltage at the frame (Tip to
Ground = -7 to -9 Vdc, Tip to Ring = -127 to -133 Vdc, Ring to Ground = -134 to -142 Vdc).
Measure T-R voltage at the TRI-R.
If voltage not present at the TRI-R, check continuity of cable pair.
If voltage is present a faulty TRI-R is indicated.
The TRI-R does not place a measurable short between tip and ring. Cable resistance must be
taken towards a manually applied short.
Power, but no Synchronization on TRI I/F
Check cable for load coils.
Check for excessive bridged taps.
Verify other deployment guidelines adhered to.
Excessive Errors on Loop
Compare resistance of individual conductors. If these are different, high-resistance or
intermittent opens may be indicated.
Check for excessive bridged taps.
Verify other deployment guidelines adhered to.
WARRANTY
Warranty for Carrier Networks products manufactured by ADTRAN and supplied under Buyer’s order for use in the U.S. is ten (10) years. For a complete copy of ADTRAN’s U.S. and Canada
Carrier Networks Equipment Warranty
: (877) 457-5007, Document #414.
COMPLIANCE
Caution: Electric shock hazard. Span voltage is present on telecommunication leads (140 Vdc).
Loading...