Admiral AAW-12CM1FHUE, AAW-22CR1FHUE, AAW-10CR1FHUE, AAW-22CM1FHUE, AAW-12CR1FHUE User Manual

...
ROOM AIR CONDITIONER
Use and Care Manual
AIRE ACONDICIONADO PARA HABITACIONES Manual de Uso y Mantenimiento
Thank you for purchasing an Admiral®room air conditioner. Please read this “Use and Care Manual” carefully before installing and using this appliance. Keep this manual for future reference.
®
. Lea atentamente el “Manual de Uso y
Mantenimiento” antes de instalar y utilizar este producto. Conserve este manual para consultarlo en el futuro.
For Service Call 1 877 465 3566
Para obtener servicio técnico, llame al 1 877 465 3566
WAC 8-24 USER MAN FINAL 3/2/05 12:13 PM Page 1
WAC 8-24 USER MAN FINAL 3/2/05 12:13 PM Page 2
1
TABLE OF CONTENTS
Page
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Parts Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Air Conditioner Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Tips Before Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-12
Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-16
Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Trouble Shooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
I´NDICE
Page
Introducción . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Identificación de las Piezas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-21
Especificaciones Eléctricas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Consejos Antes dela Instalación . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Instrucciones de Instalación . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24-28
Instrucciones de Operación . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29-32
Cuidado y Mantenimiento . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Guía para la Solución de Problemas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Garantía . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
WAC 8-24 USER MAN FINAL 3/2/05 12:13 PM Page 3
INTRODUCTION
2
PART IDENTIFICATION
WAC 8-24 USER MAN FINAL 3/2/05 12:13 PM Page 4
Thank you for choosing this room air conditioner to cool your home. This USE AND CARE MANUAL provides information necessary for the proper care and maintenance of your new room air conditioner. If properly maintained, your air conditioner will give you many years of trouble free operation. To avoid installation difficulties, read instructions completely before starting. This manual contains information for the installation and operation of your room air conditioner.
Part Identification
Mechanical control model
Front Panel
Air Filter
Interior Air Inlet Grille
Cabinet
Fresh Air Ven t Leve r
Air Outlet
5
7
3
1
O O
C
Control Knob
O F
F H IG
H F A N
H IG
H CO O
L
M E D
9
F AN
R
M
3
E
D
E
C
OO
L
L
L O W F A N
L O W
1
C O
O L
Exterior Air Inlet
Power Cord
Note: The figures in this manual are based on the external view of a standard model. Consequently, the shape may differ from that of the air conditioner you have selected.
INTRODUCTION
3
PART IDENTIFICATION
WAC 8-24 USER MAN FINAL 3/2/05 12:13 PM Page 5
Part Identification
Remote control model
Front Panel
Air Filter
Interior Air Inlet Grille
Cabinet
Fresh Air Vent Lever
Control Panel
Air Outlet
Speed
Control Panel
Exterior Air Inlet
Power Cord
Remote Control
Airconditioner
Timer
Fan Speed
Mode
Mode
Saver
Timer
High
Mid
Low
Auto
Note: The figures in this manual are based on the external view of a standard model. Consequently, the shape may differ from that of the air conditioner you have selected.
4
AIR CONDITIONER SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the SAFETY ALERT SYMBOL.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.” These words mean:
You can be killed or seriously inured if you don’t immediately
follow instructions.
You can be killed or seriously inured if you don’t follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: To reduce the risk of fire, electrical shock, or injury when using your air conditioner, follow these basic precautions:
• Plug into a grounded 3-prong outlet. • Do not use an extension cord.
• Do not remove ground prong. • Unplug air conditioning before servicing.
• Do not use an adapter. • Use two or more people to move and install air conditioner.
—SAVE THESE INSTRUCTIONS —
WAC 8-24 USER MAN FINAL 3/2/05 12:13 PM Page 6
5
INSTALLATION REQUIREMENTS
INSTALLATION INSTRUCTIONS
Electrical Requirements
ELECTRIC SHOCK HAZARD
• Plug into a grounded 3-prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can
result in death, fire, or electrical shock.
Power Supply Cord
NOTE: Your unit’s device may differ from the one shown.
Unpack the Air Conditioner
EXCESSIVE WEIGHT HAZARD
Use two or more people to move and install air conditioner.
Failure to do so can result in back or
other injury.
Remove packaging materials
• Remove and properly dispose of packaging materials. Remove tape and glue residue from surfaces before turning on the air conditioner. Rub a small amount of liquid dish soap over the adhesive with your fingers. Wipe with warm water and dry.
• Do not use sharp instruments, rubbing alcohol, flammable fluids, or abrasive cleaners to remove tape or glue. These products can damage the surface of your air conditioner.
• Handle air conditioner with care.
• The air conditioner should be connected to the appropriate electrical receptacle as shown in the chart on Page 6 (Receptacle and Fuse Types).
• The use of a time-delay fuse or time-delay circuit breaker is recommended.
• All wiring must comply with local and national electrical codes and be installed by a qualified electrician. If you have any questions, contact a qualified electrician.
A Reset Button B Test Button
This room air conditioner is equipped with a power supply cord required by UL. This power supply cord contains state-of-the-art electronics that sense leakage current. If the cord is crushed, the electronics detect leakage current and power will be disconnected in a fraction of a second.
To test your power supply cord:
1. Plug power supply cord into a grounded 3-prong outlet.
2. Press RESET.
3. Press TEST (listen for click; Reset button will trip and pop out).
4. Press and release RESET (listen for click; Reset button will latch and remain in).The power supply cord is ready for operation.
NOTES:
The Reset button must be pushed in for proper operation.
The power supply cord must be replaced if it fails to trip when the
test button is pressed or fails to rest.
Do not use the power supply cord as as an off/on switch. The
power supply cord is designed as a protective device.
A damaged power supply cord must be replaced with a new power
supply cord obtained from the product manufacturer and must not be repaired.
The power supply cord contains no use serviceable parts. Opening
the tamper-resistant case voids all warranty and performance claims.
WAC 8-24 USER MAN FINAL 3/2/05 12:13 PM Page 7
6
ELECTRICAL SPECIFICATIONS
WAC 8-24 USER MAN FINAL 3/2/05 12:13 PM Page 8
1. All wiring must comply with local and national electrical codes and must be installed by a licensed electrician. If you have any questions regarding the following instructions, contact a licensed electrician.
2. Check available power supply and resolve any wiring problems BEFORE installing and operating this unit.
3. For your safety and protection, this unit is grounded through the power cord when plugged into a matching wall outlet. If you are
not sure whether your wall outlet is properly grounded, please consult a licensed electrician.
4. The wall outlet (3-pin) must match the plug (3-pin) on the power cord supplied with the unit. DO NOT use plug adapters or extension cords. See (Table 1) for receptacle and fuse information.
5. The rating plate on the unit contains electrical and other technical data. The rating plate is located on the front of the base pan. Make sure to use the correct power supply according to the rating plate of your air conditioner.
Electric Shock Hazard
!
If the air conditioner has a serial plate rating of 115 volts and up to and including 7.5 amps, the unit maybe on a fuse or circuit breaker with other devices. However, the maximum amps on all devices for that fuse or circuit breaker can not exceed the amps of the fuse for the circuit breaker.
If the air conditioner has a serial plate rating of 115 volts and greater than 7.5 amps it must have its own fuse or circuit breaker, and no other device or unit should be operated on the fuse or circuit breaker.
If the air conditioner has a serial plate rating of 230 volts, it must have its own fuse or circuit breaker, and no other device or unit should be operated on the fuse or circuit breaker.
To avoid the possibility of personal injury, disconnect power to the unit before installing or servicing.
RECEPTACLE AND FUSE TYPES
COOLING CAPACITY
RATED VOLTS
AMPS
WALL OUTLET
FUSE SIZE
Note:8K-15K including
AAW-08CM1FHUE
AAW-10CM1FHUE AAW-12CM1FHUE AAW-15CM1FHUE
18K
22K-24K
including including AAW-22CR3FHUE
AAW-18CR3FHUE AAW-18CM3FHUE
8K-15K
125
15
15
AAW-08CR1FHUE AAW-10CR1FHUE AAW-12CR1FHUE AAW-15CR1FHUE
AAW-22CM3FHUE
AAW-24CR3FHUE AAW-24CM3FHUE
18K
250
15
15
22K-24K
250
20
20
Table 1
7
TIPS BEFORE INSTALLATION
WAC 8-24 USER MAN FINAL 3/2/05 12:13 PM Page 9
Your Room Air Conditioner unit is designed to be highly efficient and save energy. Follow these recommendations for greater efficiency.
1. Select thermostat setting that suits your comfort needs and leave the thermostat at that chosen setting.
2. The air filter is very efficient in removing airborne particles. Keep the air filter clean. Typically, the filter should be cleaned once a month. More frequent cleaning may be necessary depending on outdoor and indoor air quality.
3. Use drapes, curtains, or shades to keep direct sunlight from heating your room, but DO NOT obstruct the air conditioner. Allow air to circulate around the unit without obstructions.
4. Start your air conditioner before outdoor air becomes hot/cold and uncomfortable. This avoids an initial period of discomfort while the unit is cooling or heating off the room.
5. When outdoor temperature is cool enough, use HIGH or LOW FAN only. This circulates indoor air, providing some cooling comfort, and utilizes less electricity than when operating on a cooling setting.
Your Room Air Conditioner was designed for easy installation in a single or double-hung window. NOTE: This unit is NOT designed for vertical (slider type) windows.
! !
CAUTION
To avoid installation/operating difficulties, read the instructions thoroughly.
NOTE: Save the shipping carton and packing
materials for future storage or transport of the unit. Please check the contents of the hardware kit against the corresponding model check list, prior to installation of the unit.
See lists below.(Fig.A)
Fig. 1A Installation Hardware Model 463AAC008BA
Fig. A Installation Hardware
3/4 Screws (10)
1/4 Screws (23)
Top Channel(1)
Top Channel(1)
Bottom Channel(1) (For 8K to 12K models)
Bottom Channel(1)
or 15K to 24K models)
(F (Factory-installed)
Lock Washers(4)
Lock Washers(4)
1-1/2 x1/4 Bolts(4)
1/4 Nuts(4)
Shutter Clamp(2)
Shutter Clamp(2)
Gasket(10)
Side Curtain RH(1)
Side Curtain RH(1) Side Curtain LH(1)
Side Curtain LH(1)
Seal(1)
Foam (1)
Mounting
Mounting Brackets(2)
Brackets(2) Angle
Angle Brackets(2)
Brackets(2)
End Cap & Leveling Legs(2)
NOTE: Surplus screw(s) for spare use.
Tools Needed for Window Installation Screw drivers: Both Philips and flat head Power drill: 1/8 inch diameter drill bit Pencil Measuring tape Scissors Carpenters level
Double Adhering Seal(1)
8
INSTALLATION INSTRUCTIONS
WAC 8-24 USER MAN FINAL 3/2/05 12:13 PM Page 10
! !
Because the compressor is located on the controls side of the unit (right side), this side will be heavier and more awkward to manipulate. Inadequate support on control side of the unit can result in personal injury and damage to your unit and property. Therefore, it is recommended to have someone assist you during the installation of this unit.
1. Select the Best Location
A. Your room air conditioner was designed to fit easily into a single or double hung window. However, since window designs vary, it may be necessary to make some modifications for safe and proper installation.
B. Make sure window and frame is structurally sound and free from dry and rotted wood.
C. For maximum efficiency, install the air conditioner on side of the house or building which favors more shade than sunlight. If the unit is in direct sunlight, it is advisable to provide an awning over the unit.
D. Provide sufficient clearance around the cabinet to allow for ample air circulation through the unit. See (Fig.B). The rear of the unit should be outdoors and not in a garage nor inside of a building. Keep unit as far away as possible from obstacles and obstructions and at least 30" above the floor or ground. Curtains and other objects within a room should be prevented from blocking the air flow.
CAUTION
E. Be certain the proper electrical outlet is within reach of the installation. Use only a single outlet circuit rated at proper current (see table 1 on page 4). All wiring should be in accordance with local and national electrical codes.
F. Your unit was designed to evaporate condensation under normal conditions. However, under extreme humidity conditions, excess condensation may cause the basepan to overflow to the outside. The unit should be installed where condensation run-off cannot drip on pedestrians or neighboring properties.
Awning
20" Min.
12" Min.
20" Min.
Fence, wall, or other obstacle.
Fig.B
Side obstruction
30" Min.
Ground
Window opening requirements
(see table below)
Size
Model
Cabinet size (W*H*D) Min. Window opening Max. Window opening
8K-10K
20.5" *14.8" *23.1"
"
24
38"
12K
22.8" *15.7" *24.1"
27"
41"
26.5" *18.5" *26.9"
15-24K
30"
44"
9
INSTALLATION INSTRUCTIONS
WAC 8-24 USER MAN FINAL 3/2/05 12:13 PM Page 11
2. Preparation to Remove the Air Conditioner Slide-Out Chassis
A. Remove total of (4) Philips screws securing the chassis to the cabinet. There are (2) screws on each side. The set of screws closest to the front of the unit secure the front panel to the cabinet. The set of screw closest to the rear of the unit secure the cabinet to the chassis.
See (Fig. 1).
B. Remove the front panel assembly from the cabinet by gently pulling it.
Coil
A irc
o n d
it ion e
r
T I M
E R
F
F AN
H R
M O D
E S P E
O
E
N
D
/
O F F
WA
IT
TH R
E E M
I N U T E
S B E FOR
E R
E S T
A
R
T
I
NG
Right side Philips screws
Fig. 1
C. Grasp the pull handle at the front of the slide-out chassis and carefully slide the air conditioner out of the cabinet. See (Fig. 2).
Please seek assistance for this procedure.
Note: Screws must be reinstalled upon completion of the window installation to secure slide-out chassis.
3. Assembly of the upper & lower channels to the cabinet
A. " L" Shaped Top Channel: Stick the double adhering seal to the " L" shaped top channel, and then Install the "L" shaped top channel to the cabinet as shown in (Fig. 3) using (5) 1/4" screws. B. "n" Shaped Bottom Channel installed as shown in (Fig. 3)using (4) 1/4" screws.
NOTE: For 15K to 24K models, the bottom channel has been factory- installed, and their shapes may differ from the others,but their functions are similar.
Chassis
Pull Handle
For 8K to 12K models
Fig. 2
Double Adhering seal
1/4" Screw
Channel
For 15K to 24K models (Factory-installed).
Fig. 3
4. Assembly of the side shutters (curtains) to the cabinet.
Slide the shutters into the top and bottom channels as shown in (Fig. 4). The shutters are identified (on each frame) as "left" & "right". Attach the shutters to the cabinet using (4) 1/4" screws on each side.
Shutter Frame
1/4" screw
Right Shutter
Fig. 4
10
INSTALLATION INSTRUCTIONS
WAC 8-24 USER MAN FINAL 3/2/05 12:13 PM Page 12
5. Installation of Mounting Brackets and First Sealing Strip
NOTE: Windows come in a variety of different
styles. Therefore, it may be necessary to modify or improve your particular installation.
A. Attach the bracket assembly to 90 angle support brackets (Fig. 5) using (2) 1 1/2" bolts Two bolts per bracket. Secure with the (2) 1/4" lock washers and (2) 1/4"nuts. DO NOT immediately tighten these bolts as it may be necessary to adjust the depth of the bracket assembly, depending on the depth of your window sill. See (Fig. 7).Install the two leveling screws into the 90 support brackets. Test the bracket assembly in the window before cabinet installation. If the leveling screws are distanced too far away from the wall to provide stability, it may be necessary for you to fill this area with a solid piece of wood. See (Fig. 8).
B. Measure the inside window sill width and find the center as shown in (Fig. 6). Align the V-slot in each bracket on these marks and mount the brackets to the sill using 3/4" screws provided. Brackets should be perpendicular to the inside window sill. See (Fig. 6).
V-slot
Leveling Screw
Bracket Assembly
Bracket Bolts
(TOP VIEW)
Fig. 5
V-slot
Center
7.5"
7.5"
12.6"
Measurement for Model 8K = 7.5" Measurement for Model 10K =9 .6" Measurement for Model 12K = 10.3" Measurement for Model 15K to 24K = 12.6"
12.6"
Fig. 6
(2) 3/4" screws per bracket
Leveling Screw
Outer Wall Construction
90 Angle Support Brackets
Window sill
3/16" Maximum
Bracket Assembly
C. For proper condensation run-off it will be necessary to adjust the angle/pitch of the window brackets. This is accomplished by adjusting the distance of the leveling screw on the outer wall. The maximum angle/pitch should not exceed more than 3/16". See (Fig.7).
D. Cut the seal strip to fit the underside of the bottom window sash. Remove the peel-off backing on the seal and attach it to this sash. See (Fig. 9).
! !
CAUTION
Use a solid piece of wood to provide stability. This will be required when sills are extra deep. See (Fig. 8).
Window Sash
Window Sash Sealing Strip
Fig. 7
Fig. 8
Fig. 9
Solid Piece Wood (If required)
Loading...
+ 28 hidden pages