Operating manual
Material moisture meter
Model: ZFM 100
Manufacturer
Address: WWW. ADAINSTRUMENTS.COM

Table of contents
1. Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2. Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3. Functionality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4. Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
5. Specications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
6. Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
7. Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
8. Instrument check. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
9. Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
10. Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
11. Exceptions from responsibility. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
12. Appendix 1- “Certicate of acceptance and sale”
13. Appendix 2- “Warranty card”

ZFM 100
Kit
ZFM 100, battery, nylon bag, operating manual.
Description
ZFM 100 is an electronic dampness indicator with a measuring process working on the principle of high frequency measurement. The instrument is used for non-destructively tracing dampness in building materials of all kinds as well as for
detecting damp distribution in walls, ceilings and oors. It is particularly suitable for pretesting the readiness of building
materials for covering prior to CM measurement.
Functionality
Depth of penetration about 20-40 mm
•
Low battery indication
•
Auto Power Off
•
MAX/MIN Function
•
Measure and HOLD Function
•
Backlight
•
3
MEASUREMENT FOUNDATION

MEASUREMENT FOUNDATION
ZFM 100
Features
Metal ball
1.
LCD display
2.
Power On/Off button
3.
MAX/MIN button. When taking measurements, press MAX/MIN button, the “MAX” icon will appear on LCD display
4.
and the meter will begin keeping track of MAX value. Press the button again, “MIN” icon will appear on LCD display
and the meter will begin keeping track of MIN value. Press MAX/MIN button for two seconds to exit this mode.
Backlight
5.
4

MEAS button. Press MEAS button, the instrument will start measuring. Release this button. “HOLD”
6.
will appear on the LCD indicating that the current reading is being held.
Battery cover
7.
Specications
Sensor type electrical resistance
Measuring range 0-100 digits
Resolution 1 digit
Measuring depth 20-40 mm
Battery 9V battery
Dimensions, mm 198 x 48 x 35
Weight, gr. 180
ZFM 100
5
MEASUREMENT FOUNDATION

MEASUREMENT FOUNDATION
ZFM 100
Adjustment
The instrument is calibrated fully electronically and readjustment is not necessary.
Precautions
This is a risk of injury if the metal ball comes into a contact with live parts.
•
Use the instrument only for measuring the dampness in hardened building materials by bringing the ball into a
•
contact with the surface.
Do not take measurements on metallic linings.
•
Take measurements at distance 8-10 cm from the edge/recess.
•
Instrument check
Hold the instrument as near to the back as possible. Press the MEAS button and hold the instrument with the ball in
the air. The displayed value must be between -5 and +5.
Operation
Hold the instrument as near to the back as possible. Press the MEAS button and use the ball to scan the surface under
investigation. The ball must be in rm contact with the material. To obtain the best results, the instrument should be
held at angle of 90° to the surface to be measured.
If the icon appears on the LCD display, it indicates that the battery should be replaced. Open the battery case
and replace the battery with the new one.
-
+
6

ZFM 100
Evaluation of results
The measuring results are for orientation and pre-evaluation only; it is not a qualied dampness measurement or
relevant to specialist regulations.
The raw density of the material being measured has a noticeable inuence. Basically, the value displayed with dry and
damp building materials increases correspondingly with increasing raw density.
If the surface to be measured is dirty this will have an inuence on
the measuring result. Please remove any dirt from the surface.
Do not take measurements on metallic linings! In corners or recessed areas a distance of ca.8-10 cm form the edge/
recess must be maintained.
If the measured surface is of rough structure measured values will be higher.
Measured values can be taken from 20 mm up to 40 mm depth.
Underlying layers cannot be measured.
If the material measured has a thickness of less than 20 mm other material layers can inuence the measured value.
Construction material
Gypsum 0 - 35 dry
36 - 60 humid
61.100 wet
Cement 0 - 25 dry
26 - 50 humid
51 - 75 wet
over 75 all wet
Wood 0…50 dry
50…80 humid
80…100 wet
7
MEASUREMENT FOUNDATION

MEASUREMENT FOUNDATION
ZFM 100
WARRANTY
This product is warranted by the manufacturer to the original purchaser to be free from defects in material and workmanship under normal use for a period of two (2) years from the date of purchase.
During the warranty period, and upon proof of purchase, the product will be repaired or replaced (with the same or similar model at manufactures option), without charge for either parts of labour.
In case of a defect please contact the dealer where you originally purchased this product. The warranty will not apply to
this product if it has been misused, abused or altered. Withiut limiting the foregoing, leakage of the battery, bending or
dropping the unit are presumed to be defects resulting from misuse or abuse.
EXCEPTIONS FROM RESPONSIBILITY
The user of this product is expected to follow the instructions given in operators’ manual.
Although all instruments left our warehouse in perfect condition and adjustment the user is expected to carry out periodic
checks of the product’s accuracy and general performance.
The manufacturer, or its representatives, assumes no responsibility of results of a faulty or intentional usage or misuse
including any direct, indirect, consequential damage, and loss of prots.
The manufacturer, or its representatives, assumes no responsibility for consequential damage, and loss of prots by any
disaster (earthquake, storm, ood ...), re, accident, or an act of a third party and/or a usage in other than usual condi-
tions.
The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of prots due to a change
of data, loss of data and interruption of business etc., caused by using the product or an unusable product.
The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of prots caused by usage
other thsn explained in the users’ manual.
The manufacturer, or its representatives, assumes no responsibility for damage caused by wrong movement or action
due to connecting with other products.
8