ADA INSTRUMENTS Wheel 50 Digital User Manual [ru]

Operating manual
Measuring wheel
Model: WHEEL 50 DIGITAL
Manufacturer: ADAINSTRUMENTS Address: WWW.ADAINSTRUMENTS.COM
WHEEL 50 DIGITAL
MEASUREMENT FOUNDATION
2
Table of contents
1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2. Appearance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3. Buttons and display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
4. Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
5. Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
6. Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
7. Exceptions From Responsibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
WHEEL 50 DIGITAL
INTRODUCTION
Thank you for your choice of our products. This instrument is easy to use, accurate and reliable. You can shift between metric and inch systems, store data. Measuring wheel has touch buttons, adjustable handle. The wheel is covered with rubber to avoid slipping which ensures accuracy of measurement.
APPEARANCE
Battery compartment
Spring
Stand
Buttons
3
LCD display
Handle Handle lock
Measuring wheel
MEASUREMENT FOUNDATION
WHEEL 50 DIGITAL
MEASUREMENT FOUNDATION
4
BUTTONS AND DISPLAY
Buttons
1. Shift between metric/inch
2. Memory recall
3. LCD display
4. ON/OFF
5. Clear
6. Store data
Display
1
2
3
6
4
5
Low battery indicator
1. Memory indicator
2. Metric
3. Inch
4. Display data
5.
1 2
3 4
5
Before storage After storage Memory full
WHEEL 50 DIGITAL
FUNCTIONS
1. ON/OF — Switch
2. М/ft – shift between metrical and imperial size. When one system is selected, the relevant sign is displayed
at the right side of the display. M means metric, ft means imperial.
3. SM – memory. Push this button to store measured data. It will show M1, 2, 3 .......respectively.
4. RM- recall data. When the data is stored you can read the memory from M1 to M5. E.g. if you store 5M in M1, 10M in M2, while the current measured data is 120.7M. When you press the RM button once, it will show the data of M1 and also “R” sign at the right corner. A few seconds later the display will be back to show the current measured data again. If you press the RM button twice, it shows the stored data of M2. “R” sign is at the right corner. In several seconds the display will be back to show the current measured data again.
5. CLR –clear the current measured data. Press this button twice to clear the current measured data.
5
MEASUREMENT FOUNDATION
WHEEL 50 DIGITAL
MEASUREMENT FOUNDATION
6
TECHNICAL DATA
Max measuring range 99999.9 m Accuracy 0.5% Resolution 0.1m
Power supply 3V (2хААА/1.5V battery)
Operating temperature -10°С ….+45°С Diameter of the wheel 159 mm
WHEEL 50 DIGITAL
WARRANTY
This product is warranted by the manufacturer to the original purchaser to be free from defects in material and workmanship
under normal use for a period of two (2) years from the date of purchase.
During the warranty period, and upon proof of purchase, the product will be repaired or replaced (with the same or similar
model at manufactures option), without charge for either parts of labour.
In case of a defect please contact the dealer where you originally purchased this product. The warranty will not apply to this product if it has been misused, abused or altered. Withiut limiting the foregoing, leakage of the battery, bending or dropping the unit are presumed to be defects resulting from misuse or abuse.
EXCEPTIONS FROM RESPONSIBILITY
The user of this product is expected to follow the instructions given in operators’ manual. Although all instruments left our warehouse in perfect condition and adjustment the user is expected to carry out periodic checks of the product’s accuracy and general performance. The manufacturer, or its representatives, assumes no responsibility of results of a faulty or intentional usage or misuse including any direct, indirect, consequential damage, and loss of profits. The manufacturer, or its representatives, assumes no responsibility for consequential damage, and loss of profits by any
disaster (earthquake, storm, flood ...), fire, accident, or an act of a third party and/or a usage in other than usual conditions.
The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of profits due to a change of data, loss of data and interruption of business etc., caused by using the product or an unusable product. The manufacturer, or its representatives, assumes no responsibility for any damage, and loss of profits caused by usage other thsn explained in the users’ manual. The manufacturer, or its representatives, assumes no responsibility for damage caused by wrong movement or action due to connecting with other products.
7
MEASUREMENT FOUNDATION
Loading...
+ 15 hidden pages