Appendix 1- “Certicate of acceptance and sale”
Appendix 2- “Warranty card”
TOPLiner 3x360
1. CAUTIONS
Laser level ADA TOPLiner 3x360 is an up-to-date functional and multi-prism device designed for indoor and
outdoor performance. The device emits:
one horizontal laser line (beam scan angle of 360°)
two vertical laser lines (beam scan angle of 360°)
Do not look at the laser beam!
Do not install the device on the eye level!
Before using the device, do read this operating manual!
2. TECHNICAL REQUIREMENTS
2.1. FUNCTIONAL DESCRIPTION
Emitting a horizontal and two vertical laser line.
Quick self-leveling: when line accuracy is out of the range the laser line
ashes and the warning sound is produced. Compensator locking system
for safe transportation. Intermediate compensator locking system for slope operation.
Indoor and outdoor performance function.
Ceiling Cross
360 e
Vercal Line
Cross
360 eHorizontal Line
Down Cross
360 e
Vercal Line
3
4
TOPLiner 3x360
2.2. FEATURES
1. Keypad
2. Jack for charger
3. Battery compartment
4. Rotating base
5. Lock switch
(ON/X/OFF)
6. Vertical laser window
7. Horizontal laser window
7
1
2
3
6
5
4
Button panel
Tilt LED (1)
Indicator lights up in the intermediate position of the
compensator lock.
Detector LED (2)
Indicator lights up when press Detector button.
Power LED (3)
Indicator lights up when power is on.
Indicator blinks when power is low.
Horizontal switch (H) (4)
Detector switch (5)
Vertical switch(V) (6
TOPLiner 3x360
5
2
3
4
1
6
5
6
TOPLiner 3x360
2.3. SPECIFICATIONS
Laser 2V1H (360° laser)
Light sources 635~670nm
Laser safety class Class 2, <1mW
Accuracy ±1 mm/5 m
Self-leveling range ±4.5°
Operating range with/without receiver radius 40~50m (with detector)
Rotation/Fine adjustment 360 °/ ±10° (with Rotation base)
Power source Li battery set
Operation time Approx. 5-8 hours, if everything is on
Tripod thread 1/4 ″ and 5/8 ″
Operating temperature -10°C +40°C
Weight 0.9 kg (with Rotation base)
Size 130mm ×60mm ×160 mm (with Rotation base )
TOPLiner 3x360
3. SAFETY REQUIREMENTS AND CARE
Follow safety requirements! Don’t face and stare at laser beam!
Laser level is an accurate Instrument, which should be stored and used with care.
Avoid shaking and vibrations! Store the Instrument and It’s accessories only In the carrying case.
In case of high humidity and low temperature, dry out the Instrument and clean It after the usage.
Do not store the Instrument at a temperature below -20°C and above 50°C, otherwise the Instrument can be
out of action.
Don’t put the Instrument Into the carrying case If the Instrument or case are wet. To avoid moisture condensation Inside the Instrument- dry out the case and laser Instrument!
Check regularly Instrument adjustment!
Keep the lens clean and dry. To clean the Instrument use a soft cotton napkin!
Do not aim laser beam at persons or animals.
Do not open instrument housing. Repairs should be carried out by authorized workshops only.
Do not remove warning labels or safety instructions.
Keep instrument away from children.
Do not use instrument in explosive environment.
7
8
TOPLiner 3x360
4. ORDER WORKING
Assemblage of the rotating base
Remove the instrument from the base (Picture 1).
Place the instrument on the base (Picture 2).
Picture 2Picture 1
Insert the battery (Picture 3)
Use standard Li-battery only.
Pay attention to the polarity.
Insert the battery.
Cover the battery cover.
Li-battery
Battery cover
TOPLiner 3x360
Picture 3
9
10
TOPLiner 3x360
Mounting thread
It is possible to place the instrument on the tripod or wall mount during operation. For attachement use
thread 1/4” (pic.4) at the bottom part of the instrument or thread 5/8” (pic. 5) at the bootom part of the
rotating base.
Picture 5Picture 4
Lock Switch
Lock switch has tree positions:
TOPLiner 3x360
11
OFF mode (Pic.6)
Power is OFF. Pendulum is locked. Button panel can
not be used.
Tilt mode (Pic.7)
Power is ON. Pendulum is locked. Button panel can be used.
Vertical lines and horizontal line can be switched on/off.
ON mode (Pic.8)
Power is on. Pendulum is unlocked. Self-leveling.
Button panel can be used. Vertical lines and horizontal line can be
switched on/off. Detector mode.
Рic. 6
Рic. 7
Рic. 8
12
TOPLiner 3x360
Power warning (Picture 9)
Power LED ashes when the power is full.
Maximum operating time with all laser beams is about 30
min. All laser beams and LED will be shut off when the power
is very low. Please use the standard charger to charge the
instrument.
Charger LED (10)
The LED of the charger will be yellow when it’s charging.
When power is full, the indicator changes into green light.
The Charger should be 5V 1A . The instrument can be used
while charging.
Picture 9
Picture 10
TOPLiner 3x360
Tilt mode warning
The instrument can work in the tilt mode (intermediate position of lock switch).
Tilt LED ashes (Pic.11). Pendulum is locked. Laser lines are projected at any
angle. For example, when making stairs.
Detector mode (рic. 12)
Use the detector mode in bright light when laser beam is not visible. Press button
to switch on the dector mode. Upper LED ashes. Place the detector to
the the place of beam location. Follow the instruction of detector usage when
searching the beam.
Out of leveling warning
All the laser beams will be shut off when the instrument is out of leveling range.
The buzzer will alarm at the same time.
Transportation
Please turn the lock switch in OFF mode.
Please put the instrument on the correct position in soft bag or case.
Dot not drop it during transportation.
13
Picture 11
14
TOPLiner 3x360
Picture 12Picture 13
Usage of rotating base
360 °rotating (Picture 12)
Part A can rotate around part B by 360°.
±10° ne adjustment (Picture 13)
In leveling mode, by using adjusting
knob , the instrument can rotate
around the down dot by ± 10°.
To check the accuracy of line laser level
To check the accuracy of line laser level
(slope of plane)
Place laser level on the tripod 5m away from the
wall so the horizontal laser line will be directed
to the wall.
Switch on the power. The instrument starts to
self-level. Mark point A on the wall to show the contact of laser beam with the wall. Turn the instrument
by 90° and mark points В, С, D on the wall. Measure
distance “h” between the highest and lowest points
(these are A and D points in the picture).
If “h”is ≤ 6 mm, the measurement accuracy is
good. If “h” exceeds 6 mm, apply service center.
TOPLiner 3x360
15
Loading...