Main Operating Components 4
1Zero Point Adjustment 5
2Tare Adjustment 5
3Keypad Tare Entry 6
4Setting a Unit Price 7
5Storing a Unit Price in Memory 8
6Recalling a Unit Price from Memory 8
7Totaling Multiple Items with Unit Prices Stored in PLU Memory 8
8Clearing Totaling Memory 9
9Multiplier Function 9
10Calculating the Correct Change 10
11Clear Entry Function10
12Automatic Cancellation of a Unit Price11
13Setting “F” Functions11
14Connecting the Scale to the AD-8124 Label Printer 13
1
Thank You...
Thank you for purchasing our A&D SF/SG Series price computing scale. Before using your
price computing scale, please read the operating instructions.
Warning before connecting power plug:
–Do not place a load on the weighing pan before connecting the power supply.
–Check the power requirement label next to the power switch on the lower left side of the body
of the SF/SG scale to confirm that it corresponds to your local power requirements. Or when
appropriate, check the AC adapter.
AC ADAPTER
TB-162
91-45273
INPUT: AC100V
OUTPUT: DC7.5V 250mA
FUSE T 200mA
9V 70mA
•Unpacking and inspecting
–The SF/SG price computing scales are precision instruments. Please handle them with care.
–Please inspect your SF/SG scale when unpacking. Retain the shipping container in the event
that you need to transport the unit in the future.
–The following items should be included in your shipping container:
•SF/SG price computing scale.
•AC power adapter (except SF-A).
•Optional rechargeable battery (SF-C), if ordered.
•Optional RS-232C, if ordered.
•Instruction manual.
•Various models are capable of using rechargeable or 6 D size replaceable batteries. D size
replaceable batteries are not shipped with the unit and must be purchased locally:
Model Capacity Display Type AC Type Battery Lookup Options
Type Capability
SF- 6KA 6 kg x 2 g VFDTowerAC hardwired None 30 RS-232C
SF-15KA 15 kg x 5 g VFDTowerAC hardwired None 30 RS-232C
SF-30KA 30 kg x 10 g VFDTowerAC hardwired None 30 RS-232C
SF- 6KB 6 kg x 2 g LCDTowerAC adapter6 D size 30 RS-232C
SF-15KB 15 kg x 5 g LCDTowerAC adapter6 D size 30 RS-232C
SF-30KB 30 kg x 10 g LCDTowerAC adapter6 D size 30 RS-232C
SF- 6KC 6 kg x 2 g VFDTowerAC adapterRechargeable* 30 RS-232C
SF-15KC 15 kg x 5 g VFDTowerAC adapterRechargeable* 30 RS-232C
SF-30KC 30 kg x 10 g VFDTowerAC adapterRechargeable* 30 RS-232C
SG- 6KA 6 kg x 2 g LCDTable top AC adapter6 D size 12 RS-232C
SG-15KA 15 kg x 5 g LCDTable top AC adapter6 D size 12 RS-232C
SG-30KA 30 kg x 10 g LCDTable top AC adapter6 D size 12 RS-232C
*Note:
1. Rechargeable batteries are sold as an option.
2. D size batteries are not included with the unit and must be purchased locally.
Numerical Digits
Display:LCD TypeVFD Type
Weight Display:55
Price Display:77
Unit Price Display:66
Resolution:1/3000
Sensor:Strain gauged load cell
Character Size:
Weight Display: 18 mm 13 mm
Price Display: 20 mm 13 mm
Unit Price Display: 18 mm 13 mm
Weighing Pan Size:
300 mm x 280 mm
Physical Weight of the Scale:
SF SeriesApproximately 5.5 kg
SG SeriesApproximately 4.5 kg
Operating Temperature:
-10°C to 40°C / 14°F to 104°F; RH less than 85%
3
SF/SG Series Main Operating Components
Power Switchturns the power to
the unit on and off.
Power Switchturns the
power to the unit on and off.
WEIGHT kg UNIT PRICE $/kg
NET
ZERO
88888
9
5
1
2
1-12
10
11
6
7
8
3
4
888888
CHANGE
12
4
1
7
8
9
5
6
2
3
C
SG Model
0
Change
PRICE $
8888888
(
(
CE
MEM
O
O
O
*
X
M+
Price Lookup
(PLU) keys:
Memory storage locations
TTL
M+
T
O
Multiple displays
• Weight of product
•Zero & Tare
• Price of product
•Memory & total sale
• Unit price of product ($/kg )
•Payment received
•Change required
WEIGHT
88888
Net Zero
PRICE
8888888
Total M+
UNIT PRICE
888888
Change
SF-15KA
Max. 15kg Min 0.1kg e=0.005kg
kg
$
$/
kg
1-30
Price Lookup
(PLU) keys:
Memory storage locations
STANDBY/OPERATE:
Turns the displays on and off
(does not control power).
1-0
Numerical keypad:
Ten numerical keys to enter price
and weight values.
C
CANCEL:
Cancels key input, Unit Price, and
Total Price entries
1
CHANGE
CHANGE:
Calculates the change due to the
customer after payment.
PRINT key
*
M+
MEMORY:
Stores each entry made during a
customer’s purchase, allowing
calculation for totals & change.
24
25
26
16
17
8
9
1
2
27
28
18
19
10
11
12
3
4
29
20
13
5
30
21
14
6
7
22
15
7
8
23
4
1
2
0
(
9
(
X
5
6
3
.
C
.
.
Change
T
CE
MEM
O
M+
*
SF Model
CLEAR FROM MEMORY:
CE
Clears prices entered using the M+
key.
MEMORY RECALL:
Allows access to product prices
MEM
stored in memory.
ZERO:
0
ZERO
(
MODE
(
Zero’s the weight display when no
load is on the weighing pan, to
provide accurate calculations.
MODE:
Acts as a TOTAL key to calculate
the total price at the end of a sales
transaction.
MULTIPLIER:
X
Calculates the total value of more
than one of the same item.
T
TARE
TARE:
Subtracts unwanted weight, such as
the weight of a container, from price
calculations.
4
SF/SG Series Operating Instructions
1. Zero Point Adjustment
The zero point is automatically adjusted when power is turned on. If the display shows a positive or
negative weight, the scale must be re-zeroed.
How to re-zero:
Step 1: Assure that nothing is on the weighing pan.
Step 2: Press .
Step 3: The WEIGHT display should read:
NET
ZERO
0
ZERO
SG seriesSF series
0.000
0.000
NET ZERO
2. Tare Adjustment
When weighing with a container, it is necessary to TARE out the weight of the container in order to
get an accurate price/weight reading.
How to operate TARE:
Step 1: Place an empty container (e.g., 100 g) on the weighing pan. The display reads “ 100 ”.
Step 2: Press .
Step 3: The WEIGHT display should read:
T
TARE
SG series
NET
ZERO
Step 4: When removing the container from the pan, the display reads“ -100 ”.
0.000
SF series
0.000
NET ZERO
Note:
When a TARE weight has been set, it is not possible to set a new TARE weight of
a lower value by the procedures above. It is necessary to delete the previous TARE
first, before entering a TARE of lower value.
5