Package Contents
1. Display unit with tabletop stand
2. Power adapter
3. Instruction Manual
This product requires an AcuRite 5-in-1 Weather Sensor to be operational.
IMPORTANT
PRODUCT REGISTRATION
Register online
to receive 1 year
warranty protection
www.AcuRite.com
Questions? Contact Customer Support at
PRODUCT MUST BE REGISTERED
TO RECEIVE WARRANTY SERVICE
Archived Products
Register a Product
►
(877) 221-1252 or visit www.AcuRite.com.
SAVE THIS MANUAL FOR FUTURE REFERENCE.
1. Peak Wind Speed
Highest speed from past 60 minutes.
2. Average Wind Speed
of all speeds from past 2 minutes.
3. Learning Mode Icon
Disappears after weather forecast
self-calibration is complete.
4. Weather Select
Heat index, dew point, wind chill,
indoor temperature / humidity,
rainfall rate (rain per hour)
5. 12 to 24 Hour Weather Forecast
Self-Calibrating Forecasting pulls
data from the outdoor sensor to
generate your personal forecast.
6. Weather Select Button
Press to change the Weather Select
category data being displayed.
7. 5-in-1 Sensor Signal Strength
8. Alarm On/Off Indicator
for Selectable Category (#31).
9. Programmable Alarm Settings
10. icon
Indicates active Weather Ticker
message.
)(
11. icon
Indicates deactivated Weather
Ticker message.
12. ALARM On/Off Button
Activates alarm; press and hold to
adjust alarm values.
)(remove
13. Button
Deactivates Weather Ticker Message.
14. / Buttons
For category selection & setup
preferences.
15. SET Button
For setup preferences.
16. Button
For manually cycling Weather
Ticker messages.
17. HISTORY MODE Button
Press for all-time low and date
recorded for current category
selected on display (#31). Press
twice for all-time high and date
recorded.
addv-"
18. Button
Activates Weather Ticker message.
19. Current Outdoor Temperature
Arrow icon indicates direction
temperature is trending.
20. Outdoor Temperature Alarm On
Indicator
21. Current Outdoor Humidity
Arrow icon indicates direction
humidity is trending.
22. Outdoor Humidity Alarm On
Indicator
23. Storm Alert Alarm On Indicator
24. Current Rainfall
Accumulates data during rainfall.
25. Rain Alarm On Indicator
26. Current Barometric Pressure
27. All-Time Total Rainfall
28. Current Month Total Rainfall
29. Date
30. Clock
31. Selectable Category
32. Record Highs
Shown for current category selected
on the display (#31).
33. Record Lows
Shown for current category selected
on the display (#31).
34. Weather Ticker™
35. Current Wind Direction
36. Previous 2 Wind Directions
37. Touch Activated Backlight
Momentary during battery power,
always on/off for power adapter.
38. Current Wind Speed
39. Wind Speed Alarm On Indicator
3
Back of Display Unit
3
4
5
6
1 2
7
BACK OF DISPLAY UNIT
1. Integrated Hang Hole
for easy wall mounting
2. Plugin for Power Adapter
3. A-B-C Switch
ID code that must match 5-in-1
sensor’s A-B-C switch to ensure
units synchronize
4. CLEAR TODAY Button
Clears data recorded since
12:00am
8
5. CLEAR ALL Button
Clears all recorded data without
having to reset time and date
6. RESET Button
Full reset to factory defaults
7. Battery Compartment
8. Power Adapter
9. Battery Compartment Cover
(not shown)
4
Display Unit Setup
The display unit operates with batteries and/or power adapter. Regardless
of the power source, it is recommended that batteries always be installed to
ensure continuous operation (and retain records) in case of a power outage.
Set the A-B-C Switch Install or Replace Batteries
1
The A-B-C switch is located inside Insert 6 x AA alkaline batteries
• •
the battery compartment. It can into the battery compartment,
be set to A, B or C. However, as shown. Follow the polarity
you must select the same letter (+/-) diagram in the battery
choices for both the sensor and compartment.
the display unit in order for the
units to synchronize.
A B C
A-B-C Switch
1
set to match
sensor
2
Plug Power Adapter into
3
Electric Outlet (optional)
•
2
Install Batteries
6 AA Batteries
Momentary
backlight during
battery power.
LIGHT
used for an extended period of time. Follow the polarity (+/-) diagram in the battery compartment. Promptly remove dead batteries from the device. Dispose of used
batteries properly. Only batteries of the same or equivalent type as recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose of batteries in fire,
as batteries may explode or leak. DO NOT mix old and new batteries or types of batteries (alkaline/standard). DO NOT use rechargeable batteries. DO NOT recharge
non-rechargeable batteries. DO NOT short-circuit the supply terminals.
Backlight can always
remain on (or off)
when power adapter
is plugged in.
PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE
WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.
BATTERY SAFETY: Clean the battery contacts and also those of the device prior to battery installation. Remove batteries from equipment which is not to be
5
Plug in Power
3
Adapter
(optional)