Thank you for purchasing the Omron®BP760 IntelliSense®Automatic
Blood Pressure Monitor with ComFit
TM
Cuff.
Fill in for future reference.
DATE PURCHASED: __________________
SERIAL NUMBER: ____________________
• Staple your purchase receipt here
• Register your product on-line at
www.register-omron.com
Your new digital blood pressure monitor uses the oscillometric method
of blood pressure measurement. This means the monitor detects your
blood’s movement through your brachial artery and converts the
movements into a digital reading. An oscillometric monitor does not
need a stethoscope so the monitor is simple to use.
The BP760 comes with the following components:
• Monitor• ComFitTMCuff• AC Adapter
• Storage Case
• Instruction Manual printed in English and Spanish
• Quick Start Guide
The BP760 IntelliSense®Automatic Blood Pressure Monitor is intended
for home use.
SAVE THESE INSTRUCTIONS
4
SAFETY INFORMATION
To assure the correct use of the product basic safety measures should
always be followed including the warnings and cautions listed in this
instruction manual.
SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL
Indicates a potentially hazardous situation
WARNING
CAUTION
OPERATING THE DEVICE
Contact your physician for specific information about your blood
pressure. Self-diagnosis and treatment using measured results may
be dangerous. Follow the instructions of your physician or licensed
healthcare provider.
DO NOT adjust medication based on measurement results from this
blood pressure monitor. Take medication as prescribed by your
physician. Only a physician is qualified to diagnose and treat High
Blood Pressure.
The monitor is not intended to be a diagnostic device.
If battery fluid should get in your eyes, immediately rinse with
plenty of clean water. Contact a physician immediately.
Read all of the information in the instruction manual and any other
literature in the box before operating the unit.
which, if not avoided, could result in death or
serious injury.
Indicates a potentially hazardous situation
which, if not avoided, may result in minor or
moderate injury to the user or patient or
damage to the equipment or other property.
5
SAFETY INFORMATION
OPERATING THE DEVICE (continued)
This device is intended for use in measuring blood pressure and
pulse rate in the adult population. Do not use this device on infants
or persons who cannot express their intentions.
Read the Special Conditions section (page 30) of the instruction
manual if your systolic pressure is known to be more than 220
mmHg. Inflating to a higher pressure than necessary may result in
bruising where the cuff is applied.
Operate the device only as intended. Do not use the device for any
other purpose.
Dispose of the device, components and optional accessories
according to applicable local regulations. Unlawful disposal may
cause environmental pollution.
Do not use a cellular phone near the device. It may result in an
operational failure.
Use only Omron authorized parts and accessories. Parts and
accessories not approved for use with the device may damage the
unit.
Use only 1.5V alkaline batteries with this device.
Do not use other types of batteries. This may damage the unit.
6
SAFETY INFORMATION
RISK OF ELECTRICAL SHOCK
Do not plug or unplug the power cord into the electrical outlet with
wet hands.
Do not overload power outlets. Plug the device into the appropriate
voltage outlet.
CARE AND MAINTENANCE
Do not subject the monitor to strong shocks, such as dropping the
unit on the floor.
Do not submerge the device or any of the components in water.
Store the device and the components in a clean, safe location.
Changes or modification not approved by Omron Healthcare will
void the user warranty. Do not disassemble or attempt to repair the
unit or components.
7
BEFORE TAKING A MEASUREMENT
To ensure a reliable reading follow these recommendations:
1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for
30 minutes prior to taking a measurement. Rest for at least 15
minutes prior to taking the measurement.
5. Sit on a chair with your feet flat on the floor. Rest your arm on
a table so that the cuff is at the same level as your heart.
6. Remain still and do not talk during the measurement.
7. Wait 2-3 minutes between measurements. The wait time allows the
arteries to return to the condition prior to taking the blood pressure
measurement. You may need to increase the wait time depending on
your individual physiological characteristics.
8. Keep a record of your blood pressure and pulse readings for your
physician. A single measurement may not provide an accurate
indication of your true blood pressure. You need to take and record
several readings over a period of time. Try to measure your blood
pressure at about the same time each day for consistency.
8
Operating Instructions
KNOW YOUR UNIT
Main Unit:
SET Button
Up/Down
(
/
Display
Morning/Evening Average
() Button
Memory ( ) Button
Start/Stop Button
) Buttons
Battery Compartment
Air Jack
AC Adapter Jack
9
KNOW YOUR UNIT
7 series
Blood Pressure Monitor
with ComFitTMCuff
ModelBP760
INSTRUCTION MANUAL
ESPAÑOL
ENGLISH
Components:
Air Plug
(Connects to Air Jack)
Arm Cuff
Storage Case
Quick Start Guide
Housing
Air Tube
Cord
AC Adapter
Instruction Manual
10
UNIT DISPLAY
Date/Time Display
Morning Average Symbol
Evening Average Symbol
Irregular Heartbeat Symbol
Week Display
Systolic Blood Pressure
Diastolic Blood Pressure
Heartbeat Symbol
Low Battery Indicator
Average Value Symbol
Memory Symbol
Morning Hypertension Symbol
Movement Symbol
Blood Pressure Level Indicator
Deflation Symbol
Cuff Wrap Guide
Pulse Display / Memory Number
11
DISPLAY SYMBOLS
IRREGULAR HEARTBEAT SYMBOL ()
When the monitor detects an irregular rhythm two or more times during
the measurement, the Irregular Heartbeat Symbol () will appear on the
display with the measurement values.
Pulse
Blood
pressure
Pulse
Blood
pressure
Normal Heartbeat
Irregular Heartbeat
Short Long
An irregular heartbeat rhythm is defined as
a rhythm that varies by less than 25% from
the average rhythm or 25% more than the
average rhythm detected while the monitor
is measuring the systolic and diastolic blood
pressure.
If the irregular heartbeat symbol ()
displays with your measurement results, we
recommend you consult your physician.
Follow the directions of your doctor.
MOVEMENT ERROR SYMBOL ()
The Movement Error Symbol is displayed if you move your body during
the measurement. Please remove the arm cuff, and wait 2-3 minutes.
Take another measurement, remain still during inflation.
12
DISPLAY SYMBOLS
The American Heart Association1recommends the following guideline
for upper limit of normal for home blood pressure readings:
AHA Home Guideline for Upper Limit of Normal BP
Systolic Blood Pressure 135 mmHg
Diastolic Blood Pressure 85 mmHg
This is a general guideline because blood pressure depends on
age and morbidity. The AHA recommends a lower home blood
pressure goal for certain patients, including diabetic patients,
pregnant women, and patients with renal failure
The monitor is not intended to be a diagnostic device.
MORNING HYPERTENSION SYMBOL ()
The Morning Hypertension Symbol is displayed if the morning average
reading for a week is above 135 for the Systolic Blood Pressure value
and/or 85 for the Diastolic Blood Pressure value when viewing the
Morning Averages and the Evening Averages in the memory.
Omron Healthcare recommends you contact your physician if the
MORNING HYPERTENSION SYMBOL and/or the HEARTBEAT
SYMBOL appear on the display with your measurement values.
1
American Heart Association Scientific Statement 2004
1
.
13
DISPLAY SYMBOLS
HEARTBEAT SYMBOL ()
TAKING A MEASUREMENT
The Heartbeat Symbol flashes on the display during the
measurement. The Heartbeat Symbol flashes at every heartbeat.
AVERAGE VALUE SYMBOL ()
The Average Value Symbol is displayed when you press the memory
button. The most recent average reading appears on the display screen.
MORNING AVERAGE SYMBOL ()
The Morning Average symbol is displayed when viewing Morning
Averages using the Memory Function.
EVENING AVERAGE SYMBOL ()
The Evening Average symbol is displayed when viewing Evening
Averages using the Memory Function.
CUFF WRAP GUIDE SYMBOL(/)
When the cuff is applied correctly, () is displayed while taking a
measurement or using the memory function. If the cuff is not applied
correctly, () is displayed.
14